Remote Physiological Measurement

Recent momentum

emerging

4 papers in the last 28 days · 0.1% of indexed attention

Twelve weeks of publication activity for this topic as it is defined today.

Weekly history

Recent digests

What was published in this topic, kept on the site without email delivery.

Period ending 2026-09-21

1 new paper

A weekly snapshot of new work published in Remote Physiological Measurement.

Period ending 2026-09-07

1 new paper

A weekly snapshot of new work published in Remote Physiological Measurement.

27 papers

Latest in Remote Physiological Measurement

Sep 15, 2026cs.LG

SOTER: A Generative Time-Series Foundation Model for Wearable Human Physiological Signals

Time-series foundation models have demonstrated strong cross-domain transfer, yet their common architectural assumptions remain poorly aligned with wearable physiological signals, which are multichannel, irregularly sampled, noisy, and governed by coupled continuous-time dynamics spanning distinct spectral scales. We present SOTER, a generative foundation model for wearable physiological time series that unifies cross-channel coupling, spectrum-guided expert specialization, and continuous-time latent evolution within a single pre-training framework. SOTER combines a spatial feature-aware backbone that models inter-signal dependencies, a power spectral density (PSD)-guided mixture-of-experts layer that routes representations to experts associated with fixed spectral bands through an inspectable, non-learned rule, and a neural controlled differential equation decoder that supports prediction and imputation at arbitrary timestamps. We pre-train SOTER on 226 billion time points from five public physiological datasets and evaluate the same pre-trained model across out-of-distribution zero-shot forecasting, frozen-encoder linear-probe classification, and continuous-time imputation on wearable benchmarks. SOTER achieves the best RMSE on 4 of 6 datasets and the best MAE on 5 of 6 in zero-shot forecasting, the highest average Macro-AUROC in classification, and the lowest imputation error on all six datasets at 75% missingness. It further remains robust to additive acquisition noise, matching or surpassing baselines evaluated on clean inputs even under the strongest corruption. These results indicate that domain-specialized foundation models for wearable physiology benefit from jointly modeling channel structure, spectral scale, and continuous-time dynamics.
Fangke Chen, Sirry Chen, Wei Chen +1
Sep 3, 2026cs.RO

Establishing a Dynamic Multimodal HRI Dataset for Engagement Analysis with a Humanoid Robot

This paper presents an experimental design for constructing a multimodal dataset to analyze user engagement in human-robot interaction (HRI). Prior studies have mainly relied on observable behavioral cues, with limited frameworks integrating physiological signals. We therefore propose a structured data-collection protocol to build a multimodal dataset that includes wearable physiological signals, behavioral data, and self-report measures under different levels of task complexity defined in this experiment.
Buwan Kim, Wonse Jo
Aug 31, 2026cs.CR

NeuroPriv: Adversarial Representation Learning for Privacy in Wearable EEG Systems

Wearable EEG systems may expose sensitive information beyond their intended health function, creating substantial risks to neuroprivacy. In this work, we show that commonly used EEG features can reveal participant identity and demographic attributes in addition to supporting the intended cognitive task. Wearable EEG is increasingly being explored for cognitive monitoring, neurological assessment, and longitudinal digital-health applications, yet many systems assume that transmitting compact spectral or spatial features instead of raw EEG provides sufficient privacy protection. Using EEGMAT as a motivating case study, we find that compact EEG features achieve a balanced accuracy of 0.788 for cognitive-state classification while enabling gender, age, and subject-identity inference with balanced accuracies of 0.858, 0.789, and 0.692, respectively. We further show that privacy-aware representation learning preserves task performance at 0.781 while reducing these inference accuracies to 0.563, 0.467, and 0.206. These findings motivate purpose-limited representations and explicit privacy auditing in wearable neurohealth systems.
Sarmistha Sarna Gomasta, Bhawana Chhaglani, Prashant Shenoy
Aug 30, 2026cs.CV

PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement

Remote photoplethysmography (rPPG) enables contactless physiological measurement from facial videos, yet its subtle pulse-related variations are easily affected by illumination variation, head motion, facial blur, and region-of-interest instability. Existing methods mainly suppress interference during feature learning, while whether the learned temporal features remain affected by interference and how to further suppress such interference before rPPG estimation are rarely examined. To address this limitation, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for rPPG estimation. Specifically, a physiological backbone produces global temporal features and a coarse rPPG prediction, from which signal-derived physiological reliability evidence is constructed from local temporal characteristics. In parallel, a frozen vision-language model processes sampled facial frames under an interference-oriented prompt, and an evidence head extracts visual interference evidence from the VLM output. Temporal cross-attention integrates the physiological and visual evidence with the global temporal features to construct interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress different interference through adaptive routing. The refined temporal features are then used for final rPPG estimation. Extensive experiments on five public benchmarks demonstrate that PhysVR consistently outperforms representative methods under both intra-dataset and cross-dataset evaluation protocols.
Zixu Li, Jianjun Qian, Hang Shao +3
Aug 6, 2026q-bio.QM

A Low-Power Wearable Respiratory Sensor for Non-Invasive Stress Monitoring

Respiration provides a continuously available window into physiological state and behavior. However, monitoring it outside controlled settings remains challenging because a wearable system must capture small body deformations while remaining comfortable, low power, and robust to changes in posture and motion. We present a compact non-invasive respiratory sensing system based on a force-sensitive resistor (FSR) embedded in an abdominal belt and integrated with a custom Bluetooth Low Energy acquisition board. The system combines a simple piezoresistive readout with a mechanical holder designed to transfer abdominal expansion to the sensor without analog amplification. We evaluate the complete sensing pipeline across multiple breathing patterns and body positions. In stationary settings, the recorded signals exhibit consistent amplitude changes and recurring peak-to-peak timing across breathing maneuvers; under light movement, these variations remain visible despite motion-induced baseline shifts. We further design a five-phase stress-induction protocol and collect respiratory recordings from 12 participants. Using interpretable time-domain features and standard classifiers, we examine whether the acquired signals distinguish relaxation from stress-induction phases. In this preliminary experiment, the best-performing model achieves 88.0% test accuracy, indicating that the extracted respiratory features distinguish stress-induced phases from relaxation phases in this dataset. Overall, our results show that the proposed platform enables real-time respiratory monitoring across diverse daily-life scenarios and captures respiratory changes that distinguish stress-induction from relaxation phases, supporting its potential for affective-computing applications.
Mohammad Hosseini, Hamed Khatounabadi, Mohammad Fakharzadeh
Aug 4, 2026cs.HC

From Wearable Data to Personalized and Actionable Health Insights

Commercial wearable devices continuously capture rich physiological data (e.g., heart rate, respiration), opening new possibilities for monitoring health conditions, notably around stress. Despite their promise, turning raw wearable physiological data streams into visualizations that surface stress-related insights in daily activities, and that ultimately foster reflection, awareness, and better stress management, remains a significant challenge. The data are noisy and context-dependent: the same spike in heart rate can come from sprinting, a tense presentation, or laughing with friends. To address these challenges, we propose a framework that combines user annotations with wearable data to support better stress management. We introduce a web framework offering interactive visualizations that layer daily activities, stress events, and interventions onto raw physiological streams, enabling users to reflect and identify trends. In a four-week pilot with seven university graduate and undergraduate student participants who logged 269 events, our tool revealed patterns between different types of interventions and stress: social interaction reduced average heart rate by 4.35 to 5.0 beats per minute, deliberate rest reduced average Garmin stress scores by 10.03 to 13.83 points, and mindfulness activities decreased average HRV by 6.61 to 13.22 milliseconds.
Esther Brown, Karis Moon, Victoria Dean +1
Jul 23, 2026cs.AI

HiMe: Real-Time Self-Hosted Personal Agent Platform for Health Insights with Wearable Devices

Traditional approaches to wearable health signal analysis, such as smartwatches, are constrained by rigid analytical frameworks and limited personalisation. The emergence of LLM agents creates a new opportunity for Personal Health Agentic Analysis, where health insights can be generated adaptively and in context. However, currently there is no open-source locally deployable platform capable of processing personal health data in real time while preserving privacy. We present HiMe, a locally deployable, privacy-first agent platform that is fully compatible with real-time health data ecosystems across a wide range of wearable devices. HiMe is guided by three design principles. The database is treated as a first-class component. Effectiveness and efficiency are jointly optimised to achieve a low-cost Pareto-optimal balance. Data are processed in real time while the user is modelled over the long term. Together, these principles make it practical for individuals to harness Personal Health Agents for continuous, personalised health monitoring for better wellbeing.
Wei Liu, Siya Qi, Linhai Zhang +2
Jul 6, 2026cs.LG

KinEMbed: Decoding Kinematics from Electromyography via Cross-Modal Contrastive Learning

Decoding hand kinematics from surface electromyography (EMG) is a core challenge in wearable biosignal processing with clinical relevance for prosthetic control and motor rehabilitation. Most representation learning approaches for EMG focus on discrete gesture classification, and few focus on continuous regression. We present KinEMbed, a cross-modal contrastive learning framework for hand kinematics regression that jointly trains dual encoders -- one for windowed EMG features and one for kinematic (joint angle) targets. The resulting embeddings inherit the geometric structure of the kinematic space without requiring kinematic signals at inference time. Evaluating on the NinaPro DB8 dataset that includes both able-bodied users and subjects with limb difference (N=11), KinEMbed outperforms PCA, PLS, autoencoder and contrastive (CEBRA) baselines on held-out sessions, with largest gains on the most challenging thumb degrees of articulation. We position this work as a first step toward contrastive representation learning for regression of hand kinematics from structured wearable biosignals.
Sofia Gilardini, Chenfei Ma, Kianoush Nazarpour
Jun 26, 2026cs.CV

RPM-Distill: Physiology-guided Adaptive Cross-modal Distillation for Robust Remote Physiological Measurement

Video-based remote physiological measurement (RPM) is highly accessible but remains fragile under varying illumination, skin tones, and motion. Radio frequency (RF) radar is largely invariant to illumination and appearance, providing complementary cardio-respiratory micro-motion cues; however, requiring radar at inference is often impractical due to its limited ubiquity and deployment overhead. We propose RPM-Distill, a physiology-guided cross-modal distillation framework that leverages synchronized radar only during training while retaining video-only inference. Our key observation is that although RGB and RF waveforms differ in sensing physics and time-domain morphology, they share similar latent periodic rhythm in the frequency domain. We thus distill physiology-structured spectral evidence to improve robustness, via losses that (i) anchor the fundamental peak, (ii) match the off-peak background distribution, and (iii) preserve spectral morphology and sharpness. To avoid negative transfer under sample-level teacher quality and alignment uncertainty, a spectral policy network predicts sample-level distillation gates and component weights from the student--teacher spectral relation map, learned with a meta bilevel objective on a small labeled validation split. Through extensive experiments in challenging conditions and cross-dataset settings, RPM-Distill brings 81% MAE and 21% correlation improvement over unimodal baselines. Code is at https://github.com/WJULYW/RPM-Distill.
Jiyao Wang, Qingyong Hu, Duoxun Tang +3
Jun 11, 2026stat.AP

Event-Aligned Analysis of Multi-Rater Pain Assessments Using Continuous Wearable Physiology

Pain is assessed differently by patients, nurses, and clinicians, yet most computational approaches assume a single ground-truth label - effectively ignoring who is doing the rating. We introduce a rater-aware, event-aligned framework that converts sparse, rater-specific pain ratings into discrete pain-change events and aligns continuous wearable physiological signals to these events, preserving rater identity throughout. Applied to multimodal wearable data collected during spine-related pain procedures, the framework identifies substantial disagreement across rater groups and provides preliminary, exploratory evidence of rater-dependent physiological differences preceding reported pain increases. These findings suggest that pain-physiology relationships may not be rater-invariant, and that aggregating assessments across raters may mask meaningful physiological patterns. A rater-aware, event-aligned perspective is therefore a promising direction for interpreting wearable data in real-world clinical pain assessment.
Saba A. Farahani, Elahe Khatibi, Thomas D. Hughes +3
May 28, 2026cs.AI

VitalAgent: A Tool-Augmented Agent for Reactive and Proactive Physiological Monitoring over Wearable Health Data

Wearable devices enable continuous monitoring of physiological signals such as ECG and PPG, but existing mHealth systems are largely limited to task-specific prediction pipelines or reactive question answering over static summaries. They lack the ability to support temporal reasoning, persistent physiological context, and proactive monitoring over long-term signal streams. We propose VitalAgent, a tool-augmented agentic framework for ECG/PPG-based mHealth that supports both reactive question answering and proactive monitoring. VitalAgent is built on a longitudinal physiological memory and a tool-augmented reasoning interface that enables dynamic computation over raw signals. We further introduce VitalBench, a longitudinal physiological monitoring benchmark dataset comprising 1,862 QA pairs for reactive question answering and 90.2 hours of continuous ECG/PPG recordings for proactive monitoring, covering cardiac, physical activity, and stress-related tasks. Experiments demonstrate that VitalAgent achieves over 25% improvement over prompt-based and ReAct baselines in reactive evaluation and supports proactive alert monitoring over long-term physiological signals, highlighting the importance of dynamic tool use and long-term physiological monitoring.
Di Zhu, Yu Yvonne Wu, Hong Jia +3
May 23, 2026cs.LG

Synheart Capacity: A Theory-Driven Physiological Representation of Cognitive Capacity Dynamics from Wearable Signals

Human cognitive performance is constrained by limited mental resources, yet continuous computational estimation of cognitive capacity dynamics remains an open challenge. We propose a theory-driven multimodal learning framework that models capacity-related cognitive state as a two-dimensional physiological representation defined by voluntary resource allocation (mental effort) and overload-related strain (stress). The proposed architecture combines dual-stream encoding of cardiac (IBI/HRV) and electrodermal (EDA) signals with late fusion and task-specific output heads that independently estimate probabilistic effort and stress states. Evaluation on the SWELL-KW dataset using strict leave-one-subject-out cross-validation demonstrates cross-individual generalization (stress: 70.0% balanced accuracy; effort: 72.2%), with significant gains from multimodal integration and theory-guided supervision. Rather than collapsing physiological dynamics into a single workload label, the proposed effort--stress state-space enables structured differentiation between distinct cognitive regimes, including productive engagement and overload-related strain. Predicted state trajectories exhibit significant demand-sensitive shifts under controlled workload manipulations, with effort and stress responding differentially across interruption and time-pressure conditions. These results suggest that physiologically grounded multidimensional state representations may provide a foundation for adaptive systems capable of continuous capacity-aware monitoring and human-centered interaction.
Yisak Debele, Henok Ademtew, Israel Goytom
May 22, 2026cs.CV

LQ-rPPG: A Label-Quantized Coarse-to-Fine Learning Framework for Remote Physiological Measurement

Remote photoplethysmography (rPPG) enables non-contact measurement of physiological signals from facial videos, offering strong potential for remote healthcare and daily health monitoring. Driven by this potential, various deep learning-based rPPG methods have been proposed to improve rPPG estimation. However, previous deep learning-based rPPG methods have paid little attention to the quality of training labels and their impact on model learning. Contact-based PPG signals used as training labels often contain noise and variability caused by motion artifacts, inconsistent sensor contact, and morphological distortions. Such label inconsistency can lead models to overfit to the label noise and variability and consequently degrade generalization performance. To address this issue, we propose LQ-rPPG, a label-quantized coarse-to-fine learning framework for robust rPPG estimation. LQ-rPPG consists of a label quantization module and a coarse-to-fine rPPG estimation model. The label quantization module transforms continuous PPG signals into multi-bit quantized pseudo labels with reduced noise and variability. The coarse-to-fine estimation model progressively refines rPPG signals under hierarchical supervision guided by the multi-bit pseudo labels. This design alleviates overfitting to label-specific variations and enables the model to learn structured and consistent representations. As a result, LQ-rPPG achieves robust and generalizable rPPG estimation even under challenging conditions. Experiments on multiple benchmark datasets demonstrate that LQ-rPPG achieves strong performance in both intra- and cross-dataset evaluations, while reducing parameters and multiply-accumulate operations by 88% and 29%, respectively, and increasing throughput by 191%. The code is available at https://github.com/Anonymous-repo-code/LQ-rPPG.
Jun Seong Lee, Samyeul Noh, Changki Sung +1
May 21, 2026cs.LG

CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment

Assessing cognitive load continuously and at low latency would help adaptive human-computer interaction, but it remains hard because labeled data are scarce and models generalize poorly across subjects. Recent ECG foundation models, pre-trained on millions of clinical diagnostic ECG recordings, yet they do not apply directly to wearable devices when the sensor configuration and the task both differ. We present CogAdapt, a framework that adapts a clinical ECG foundation model to wearable cognitive load assessment. CogAdapt has two parts. LeadBridge is a learnable adapter that maps 3-lead wearable signals to a 12-lead-compatible representation. ProFine is a progressive fine-tuning strategy that unfreezes encoder layers in stages while limiting representational drift in the pre-trained model. On two public datasets (CLARE and CL-Drive) under leave-one-subject-out cross-validation, CogAdapt reaches macro-F1 of 0.626 and 0.768, improving over from-scratch baselines by 11.2 and 16.1 percentage points. The results show that a clinical ECG pretraining can support subject-independent cognitive load assessment from wearable sensors.
Amir Mousavi, Erfan Nourbakhsh, Mohammad Sadegh Sirjani +5
May 19, 2026cs.HC

AffectAI-Capture: A Reproducible Multimodal Protocol for Small-Group Meeting Research

We present AffectAI-Capture, a protocol for collecting synchronized multimodal data in four-person meeting-like interactions, combining eye tracking, wearable physiology, close-talk and room audio, multi-view video, event logging, and structured self-report. Sessions use fixed task blocks grounded in established group-interaction paradigms, while acquisition and post-processing are organized around a single authoritative event timeline and standardized outputs. We describe the experimental rationale, synchronization philosophy, data organization, and practical trade-offs. Pilot-level validation of audio quality and video synchronization has been conducted using controlled bench tests; full protocol sessions with participants remain ongoing work. The contribution is a reproducible protocol architecture linking task design, instrumentation, timing provenance, and data packaging for affective, behavioral, and meeting-analytics research.
Meisam Jamshidi Seikavandi, Alice Modica, Anna Obara +6
May 14, 2026cs.MA

Decision-Level Fusion for Robust Wearable Affect Recognition

Automatic recognition of affective state from wearable physiology has clear societal impact for public health, preventive care, and stress-aware interventions, but real deployments require robustness to non-stationary dynamics, artefacts, and missing sensors. We study this problem on WESAD, using baseline, stress, and amusement conditions, where common fixed-basis spectral features such as FFT bandpower and Welch PSD can oversmooth short-lived discriminative patterns. We propose a non-stationary pipeline that combines Fourier-Bessel Series Expansion (FBSE) with EWT data-driven spectral segmentation to extract mode-wise transient descriptors. For multimodal integration, we adopt decision-level aggregation over per-modality predictors and weight each modality by predictive uncertainty and modality reliability. Results on WESAD, using 15 subjects and ECG, EDA, BVP, EMG, and ACC signals across three classes, indicate that decision-level aggregation is approximately 84 percent of the time at least as good as feature-level aggregation, and approximately 48 percent of the time strictly better, suggesting improved robustness under heterogeneous and partially reliable sensing.
Lokesh Singh, Athina Georgara, Jayati Deshmukh +2
May 14, 2026cs.HC

A Formative Study of Brief Affective Text as a Complement to Wearable Sensing for Longitudinal Student Health Monitoring

Wearable devices capture physiological and behavioral data with increasing fidelity, but the psychological context shaping these outcomes is difficult to recover from sensor data alone, limiting passive sensing utility for digital health. We examined whether ultra-brief naturalistic concern text could serve as a scalable complement to passive sensing. In a year-long study of 458 university students (3,610 person-waves) tracked with Oura rings, participants responded bimonthly to an open-ended prompt about what concerned them most; responses had a median length of three words. We compared dictionary-based, general pretrained, and domain-adapted NLP approaches using within-person mixed-effects models across nine sleep and physical activity outcomes. Weeks dominated by academic concern framing were associated with lower physical activity; weeks characterized by emotional exhaustion language were associated with poorer sleep quality and lower heart rate variability. General pretrained embeddings outperformed domain-adapted models for most outcomes, with domain adaptation showing relative advantage for autonomic outcomes. Zero-shot classification of concern topics produced no significant associations, while affective dimensions across all three methods were consistently associated with outcomes, indicating emotional register rather than topical content carries the signal. These findings offer design guidance: ultra-brief affective prompts enrich the psychological interpretability of passive physiological data at minimal burden.
Tamunotonye Harry, Johanna Hidalgo, Matthew Price +7
May 13, 2026cs.LG

VCR: Learning Valid Contextual Representation for Incomplete Wearable Signals

Wearable devices enable continuous health monitoring from multimodal signals, but real-world deployment is hindered by limited labeled data and pervasive sensor incompleteness. While large-scale self-supervised pretraining reduces label dependence, most existing methods assume full modality availability. Current approaches for handling modality missingness often reconstruct entire absent signals, which can encourage hallucinating modality-specific details that are not inferable from the observed sensor signals and degrade robustness. We propose VCR, a self-supervised framework that learns to extract valid representations robust to modality missingness. VCR employs an orthogonal tokenizer to enforce strict orthogonal disentanglement by rectifying latent manifolds and applying a geometric projection, separating each modality into shared semantics and modality-specific residuals. This design preserves complete information integrity while serving as a structural foundation for robust learning under modality missingness. The resulting tokens are processed by a missing-aware mixture-of-experts backbone that adapts to varying patterns of modality availability. By constraining the objective to reconstruct only the shared components of missing modalities, VCR effectively mitigates hallucinations of non-inferable modality-specific details. Across multiple health monitoring tasks, VCR consistently improves performance and robustness under full, single-missing, and multiple-missing modality settings compared with strong supervised and self-supervised baselines.
Yuxuan Weng, Wenhan Luo, Qijia Shao
May 9, 2026cs.LG

WavesFM: Hierarchical Representation Learning for Longitudinal Wearable Sensor Waveforms

Wearable sensors enable the continuous acquisition of high-resolution physiological waveforms, such as photoplethysmography and accelerometry, under free-living conditions. However, inferring health-related phenotypes from these signals presents significant challenges due to high sampling frequencies, multimodal dependencies, and extreme sequence lengths (e.g., weeks of recordings), compounded by a scarcity of ground-truth labels. To address these challenges, existing self-supervised learning (SSL) methodologies typically follow two paradigms: (1) learning rich morphological representations from short waveform segments while collapsing longitudinal dynamics through simple aggregation, or (2) modeling behavioral patterns from coarse, hand-crafted features (e.g. heart rate, step counts) spanning longer horizons but foregoing subtle, predictive signatures in raw waveforms. To bridge this gap, we propose WavesFM, a foundation model utilizing a two-stage SSL framework for longitudinal physiological data. Specifically, we decompose the learning problem into two stages: first, a segment-level encoder is pretrained to extract local embeddings from short waveforms; subsequently, a temporal encoder is trained to model the sequence of these embeddings across a multi-day horizon. This hierarchical approach overcomes the computational complexity of high-resolution, long-sequence data, allowing the overall model to capture both local signal semantics and the complex circadian and inter-day variations governing physiological dynamics. Pretrained on over 6.8M hours (N=324k individuals) of recordings for the first stage and 5.3M hours (N=10k) for the second stage, WavesFM demonstrates superior performance across 58 diverse tasks spanning demographics, lifestyle, health conditions, and medications.
Peng Cao, Zhijian Yang, Tennison Liu +17
May 5, 2026eess.SP

Domain-Adaptive Arrhythmia Classification Using a Hybrid Transformer on Wearable Heart Signals

Cardiovascular disease remains the leading cause of death globally, underscoring the need for effective, accessible monitoring solutions, particularly through wearable devices that enable continuous, real-time tracking of heart rhythms in home settings. However, deploying deep learning models trained on clinical electrocardiogram (ECG) datasets to wearable devices remains challenging, as differences in recording equipment, signal quality, and patient populations introduce domain shifts that degrade model performance. We propose a hybrid transformer model that processes continuous ECG signals alongside seven heart rate variability (HRV) features, where the raw signal path captures beat-level morphological patterns and the HRV path encodes rhythm regularity statistics, allowing the model to jointly leverage complementary information from both representations. To enhance the model's ability to generalize across domains, we employ representation learning techniques, including Maximum Mean Discrepancy (MMD), a non-parametric kernel-based metric that quantifies the distance between feature distributions of different domains, to align feature distributions between source and target domains, addressing the challenge of domain shifts between public datasets and wearable device data. By leveraging five public ECG datasets for training, the model learns robust, generalized representations that mitigate domain-specific biases. When tested on wearable device data with an unseen domain, the model achieved an F1-macro 95% and balanced accuracy of 96.15%. These results demonstrate minimal performance degradation, with only a 2% drop in F1-macro compared to seen-domain evaluation, highlighting the model's generalization capabilities and its potential for reliable, real-time heart monitoring applications in home and ambulatory settings.
Maedeh H. Toosi, Siamak Mohammadi
May 5, 2026cs.LG

From Muscle Bursts to Motor Intent: Self-Supervised Token Modeling for Heterogeneous EMG

Surface electromyography provides a practical way to infer human movement intention from wearable muscle recordings, but models trained under a single acquisition setting often lose reliability when the user, session, electrode layout, or gesture protocol changes. This paper proposes AEMG, a self-supervised learning approach designed to extract reusable neuromuscular representations from diverse EMG sources. Eight public gesture datasets are first transformed into a shared signal format to reduce discrepancies in channel configuration, sensor topology, and recording protocol. Instead of relying on fixed-length sliding windows, AEMG identifies contraction events from energy variations and represents them as compact neuromuscular tokens, while ordered token groups describe the coordinated activity of multiple muscles during motion. A spatially and temporally conditioned Transformer is then used to encode these token sequences, preserving information about electrode position, activation timing, and sequential structure. For pre-training, the model constructs a discrete library of contraction prototypes through vector-quantized reconstruction and further learns contextual dependencies by recovering masked neuromuscular tokens from surrounding observations. Experiments under leave-one-subject-out and low-label adaptation settings show that the learned representation improves robustness to unseen users and reduces the amount of calibration data required for gesture recognition. These findings suggest that event-level token modeling offers a scalable route toward adaptable and data-efficient EMG-based motor-intent understanding.
Zhenghao Huang, Huilin Yao, Kaikai Wang
May 2, 2026cs.HC

EduGage: Methods and Dataset for Sensor-Based Momentary Assessment of Engagement in Self-Guided Video Learning

Engagement, which links to attentional, emotional, and cognitive dimensions, plays an important role in learning. In online and video-based learning environments, learners often need to regulate their own interactions with instructional materials. Measuring and reflecting on engagement can therefore support both learners and adaptive learning systems. In this study, we use wearable and camera-based sensing devices to collect physiological and motion signals, including PPG, ECG, EDA, EEG, IMU, heart rate, temperature, and eye-tracking data, to estimate learner engagement. We conducted a user study with 16 participants in a video-based learning scenario, where participants completed learning tasks and provided repeated in-situ self-reports of engagement through brief probes. We develop and evaluate a system for engagement estimation, compare different sensing modalities, and further analyze the feasibility and effectiveness of multimodal modeling for characterizing learner engagement. Across participant-based cross-validation, our model achieves an MAE of 0.81, 83.75% within-1 accuracy, 73.93% binary accuracy, and 68.45% binary Macro-F1, outperforming sensor-free, statistical, deep temporal, foundation-model, and LLM-based baselines. Our results suggest that fine-grained engagement estimation is feasible but inherently noisy, and that practical systems should prioritize lightweight combinations of behavioral and physiological signals over full multimodal instrumentation. We release the EduGage dataset, including synchronized multimodal sensor signals, probe-aligned momentary engagement labels, video metadata, quizzes, and study materials, to support reproducible research on fine-grained sensor-based engagement modeling in self-guided learning.
Zikang Leng, Edan Eyal, Yingtian Shi +3
Apr 16, 2026cs.AI

Personalized and Context-Aware Transformer Models for Predicting Post-Intervention Physiological Responses from Wearable Sensor Data

Consumer wearables enable continuous measurement of physiological data related to stress and recovery, but turning these streams into actionable, personalized stress-management recommendations remains a challenge. In practice, users often do not know how a given intervention, defined as an activity intended to reduce stress, will affect heart rate (HR), heart rate variability (HRV), or inter-beat intervals (BBI) over the next 15 to 120 minutes. We present a framework that predicts post-intervention trajectories and the direction of change for these physiological indicators across time windows. Our methodology combines a Transformer model for multi-horizon trajectories of percent change relative to a pre-intervention baseline, direction-of-change calls (positive, negative, or neutral) at each horizon, and an empirical study using wearable sensor data overlaid with user-tagged events and interventions. This proof of concept shows that personalized post-intervention prediction is feasible. We encourage future integration into stress-management tools for personalized intervention recommendations tailored to each person's day following further validation in larger studies and, where applicable, appropriate regulatory review.
Esther Brown, Victoria Dean, Finale Doshi-Velez
Dec 9, 2025cs.AI

DeepFeature: LLM-Empowered Context-aware Feature Generation for Wearable Biosignals

Biosignals collected from wearable devices are widely utilized in healthcare applications. Machine learning models used in these applications often rely on features extracted from biosignals due to their effectiveness, lower data dimensionality, and wide compatibility across various model architectures. However, existing feature extraction methods often lack task-specific contextual knowledge, struggle to identify optimal features in high-dimensional combinatorial feature space, and are prone to automated code generation and execution errors. In this paper, we propose DeepFeature, the first LLM-empowered, context-aware feature generation framework for wearable biosignals. DeepFeature introduces a multi-source feature generation mechanism that integrates the inherent ability of LLMs, expert knowledge and inter-feature interactions. It also employs an iterative feature refinement process that uses feature assessment-based feedback for feature re-selection. Additionally, DeepFeature utilizes a robust multi-layer filtering and verification approach for feature description-to-code translation to ensure that the feature extraction functions run without crashing. Experimental evaluation results show that DeepFeature achieves the highest average AUROC across eight tasks under both sample-level and subject-level settings, outperforming the best baselines by 4.60% and 4.61%, respectively. DeepFeature achieves the most pronounced gains on the PPG-BP tasks, while remaining competitive with the best-performing baselines on Epilepsy, WESAD, and our self-collected SEN dataset.
Kaiwei Liu, Yuting He, Bufang Yang +6
May 21, 2025cs.RO

Human Supervisor Workload Prediction: Lag Horizon Selection

Teleoperation systems must be aware of the human's workload during missions to maintain operator performance. Prior work employed wearable physiological sensor response metrics to estimate current human workload; however, these estimates only enable robots to respond to under- or overload conditions reactively. Current human workload prediction approaches are limited to very short prediction horizons and fail to investigate variable lag horizons' impact on those predictions. This manuscript investigates physiological sensor driven human workload prediction focusing on the impact of lag horizons on both univariate and multivariate time series forecasting models, with longer prediction horizons than the workload prediction state-of-the-art (i.e., > 30 seconds using Long Short-Term Memory networks). Models were trained using data from a 64 participant non-sedentary supervisory environment NASA Multi-Attribute Task Battery-II human subjects evaluation. A key finding is that univariate workload predictions required 240 second lag horizons, whereas multivariate workload predictions sufficed with 120 second lag horizons. This finding indicates additional workload components reduce lag horizon requirements, enabling more efficient models with longer prediction horizons.
Mark-Robin Giolando, Julie A. Adams
Feb 3, 2025cs.LG

A Wearable Device Dataset for Mental Health Assessment Using Laser Doppler Flowmetry and Fluorescence Spectroscopy Sensors

Mental health problems such as stress, anxiety, and depression affect millions of people worldwide. These conditions are usually assessed using questionnaires, which rely on how people describe their own feelings. In this study, we explore whether a wearable device can help measure mental health using physical signals from the body. The device records small changes in blood flow and tissue activity from the fingertip. We collected data from 132 adults across 19 countries and compared these signals with mental health questionnaire results. We found that patterns in blood flow and tissue activity are linked to stress-related symptoms. This approach may help develop new tools for simple, non-invasive mental health monitoring in everyday life. Code and datasets are publicly available: https://github.com/leduckhai/Wearable_LDF-FS
Minh Ngoc Nguyen, Khai Le-Duc, Tan-Hanh Pham +7
Jun 11, 2024cs.HC

Wearable Device-Based Real-Time Monitoring of Physiological Signals: Evaluating Cognitive Load Across Different Tasks

This study employs cutting-edge wearable monitoring technology to conduct high-precision, high-temporal-resolution (1-second interval) cognitive load assessment on electroencephalogram (EEG) data from the FP1 channel and heart rate variability (HRV) data of secondary vocational students. By jointly analyzing these two critical physiological indicators, the research delves into their application value in assessing cognitive load among secondary vocational students and their utility across various tasks. The study designed two experiments to validate the efficacy of the proposed approach: Initially, a random forest classification model, developed using the N-BACK task, enabled the precise decoding of physiological signal characteristics in secondary vocational students under different levels of cognitive load, achieving a classification accuracy of 97%. Subsequently, this classification model was applied in a cross-task experiment involving the National Computer Rank Examination (Level-1), demonstrating the method's significant applicability and cross-task transferability in diverse learning contexts. Conducted with high portability, this research holds substantial theoretical and practical significance for optimizing teaching resource allocation in secondary vocational education, as well as for cognitive load assessment methods and monitoring. Currently, the research findings are undergoing trial implementation in the school.
Ling He, Yanxin Chen, Wenqi Wang +2