Chest X-Ray
Momentum
12 papers in the last four weeks, up 50% on the four weeks before. 0.1% of all new papers.
Latest papers 82
Vision-language alignment using chest X-rays and radiology reports has emerged as an advanced paradigm for zero-shot classification and grounding of chest X-ray findings. However, standard contrastive learning typically treats radiographs and reports from different patients simply as negative pairs. This assumption introduces noisy negatives, as different patients frequently exhibit similar findings. Such noisy negatives cause semantic ambiguity and degrade performance in zero-shot understanding tasks. To address this challenge, we propose CoNNS, a concept-guided noisy-negative suppression framework. To support the negative suppression mechanism, unlike previous methods that use raw reports or templatized texts, we construct a hierarchical concept ontology using large language models. The ontology structures 41 key clinical concepts by explicitly modeling presence, attributes (location and characteristics), and texts (evidential segment and presence statement). Leveraging this ontology, we implement a cross-patient pair relabeling strategy comprising three steps: (1) Fine-Grained Breakdown to categorize pairs based on finding presence; (2) Noisy Negative Filtering to resolve semantic conflicts by removing false negatives; and (3) Hard Negative Mining to identify subtle attribute discrepancies using a lightweight language model. Finally, we propose a Concept-Aware NCE loss to align visual features with text while suppressing the identified noisy negatives. Extensive experiments across multi-granularity zero-shot grounding tasks and five zero-shot classification datasets validate that CoNNS outperforms existing state-of-the-art models. The code is available at https://github.com/DopamineLcy/conns.
Flow Matching with Optimized Subclass Priors for Medical Image Augmentation
Rare diseases dominate the diagnostic challenge in medical imaging yet are severely underrepresented in clinical datasets, causing classifiers to fail on exactly the conditions where reliable detection matters most. Generative augmentation can supply the missing tail-class coverage, but coarse disease labels aggregate diverse subtypes and acquisition settings into multi-modal conditionals that bias generators toward dominant submodes, while a shared Gaussian source forces rare subpopulations through disproportionately long transport paths. We propose an offline strategy that introduces informative priors at two levels: first, we partition each coarse label into coherent submodes via Gaussian mixture modeling in the generative model's latent space; second, we learn subclass-conditioned source distributions that re-center and re-scale the starting distribution per submode, shortening trajectories and reducing within-subclass dispersion. To prevent degenerate solutions we impose explicit geometric control, moderately concentrating normalized displacement directions around learnable prototypes while capping path-length outliers. On long-tailed chest X-ray (MIMIC-LT, NIH-LT) and CT slice (CT-RATE) benchmarks the proposed method consistently improves tail-class generation fidelity and diversity (FID, IRS) and is a promising augmentation strategy that reliably improves downstream balanced accuracy and macro-F1 over a non-augmented baseline across modalities.
MI-CXR: A Benchmark for Longitudinal Reasoning over Multi-Interval Chest X-rays
Longitudinal chest X-ray (CXR) interpretation requires reasoning over disease evolution across multiple patient visits, yet most existing medical VQA benchmarks focus on single images or short-horizon image pairs. We introduce MI-CXR, a benchmark for standardized evaluation of Multi-Interval longitudinal reasoning over multi-visit CXR sequences, without requiring free-form report generation or additional clinical context. MI-CXR comprises five-way multiple-choice questions over five-visit patient timelines and instantiates three complementary task families: Temporal Event Localization, Interval-wise Change Reasoning, and Global Trajectory Summarization, which assess clinically grounded visual reasoning over time. Evaluating 14 state-of-the-art vision-language models (VLMs) shows low overall performance, with an average accuracy of 29.3%, only modestly above random guessing. Using stage-wise diagnostic probing, we find that models often produce locally plausible interval descriptions but fail to enforce temporal constraints or compose evidence into globally consistent decisions over the full timeline. These findings reveal key limitations of current VLMs and establish MI-CXR as a principled benchmark for longitudinal medical reasoning. The benchmark is available at https://github.com/AIDASLab/MI-CXR
Few-Shot Synthetic Data Generation with Diffusion Models for Downstream Vision Tasks
Class imbalance is a persistent challenge in visual recognition, particularly in safety-critical domains where collecting positive examples is expensive and rare events are inherently underrepresented. We propose a lightweight synthetic data augmentation pipeline that fine-tunes a LoRA adapter on as few as 20-50 real images of a rare class and uses a pretrained diffusion model to generate synthetic samples for training. We systematically vary the synthetic-to-real ratio and evaluate the approach across two structurally different domains: chest X-ray pathology classification (NIH ChestX-ray14) and industrial surface crack detection (Magnetic Tile Defect dataset). All evaluations are performed on held-out sets of real images only. Across both domains, synthetic augmentation consistently improves rare-class recall and F1 compared to training with real data alone. Performance improves with moderate synthetic augmentation and shows diminishing returns as the synthetic ratio increases. These results suggest that LoRA-adapted diffusion models provide a simple and scalable mechanism for augmenting rare classes, enabling effective learning in data-scarce scenarios across heterogeneous visual domains.
CheXTemporal: A Dataset for Temporally-Grounded Reasoning in Chest Radiography
Chest radiograph interpretation requires temporal reasoning over prior and current studies, yet most vision-language models are trained on static image-report pairs and lack explicit supervision for modeling longitudinal change. We introduce CheXTemporal, a dataset for temporally grounded reasoning in chest radiography consisting of paired prior-current chest X-rays (CXR) with finding-level temporal and spatial annotations. The dataset includes a five-class progression taxonomy (new, worse, stable, improved, resolved), localized spatial supervision of pathology, explicit spatial-temporal alignment across paired studies, and multi-source coverage for cross-domain evaluation. We additionally construct a 280K-pair silver dataset with automatically derived temporal and anatomical supervision for large-scale evaluation under weaker supervision. Using these resources, we evaluate multiple state-of-the-art vision-language CXR models on grounding and progression-classification tasks in a zero-shot setting. Across both gold and silver evaluations, current models exhibit consistent limitations in spatial grounding, fine-grained temporal reasoning, and robustness under distribution shift. In particular, models perform substantially better on salient progression categories such as worse than on temporally subtle states such as stable and resolved, suggesting limited modeling of longitudinal disease evolution in chest radiography.
Radiologist-Guided Causal Concept Bottleneck Models for Chest X-Ray Interpretation
Concept Bottleneck Models (CBMs) in medical imaging aim to improve model interpretability by predicting intermediate clinical concepts before final diagnoses. However, most existing CBMs treat concepts as discriminative predictors of pathology labels, without explicitly modelling the underlying clinical generative process where diseases produce observable radiographic findings. We propose XpertCausal, a radiologist-guided causal CBM for chest X-ray interpretation which models pathology-to-concept relationships using a probabilistic noisy-OR framework. This generative model is then inverted via Bayesian inference to estimate pathology probabilities from predicted concepts. Radiologist-curated concept-pathology associations are used to constrain model structure to radiologist-defined clinically plausible reasoning pathways. We evaluate XpertCausal on MIMIC-CXR across pathology classification performance, calibration, explanation quality, and alignment with radiologist-defined reasoning pathways. Compared with both a non-causal CBM baseline and a causal ablation with unconstrained learned associations, XpertCausal achieves improved AUROC, calibration, and clinically relevant explanation quality, while learning concept-pathology relationships that more closely align with expert knowledge. These results demonstrate that incorporating clinically motivated causal structure and expert domain knowledge into CBMs can lead to more accurate, interpretable, and clinically aligned models for CXR interpretation.
CXR-ContraBench: Benchmarking Negated-Option Attraction in Medical VLMs
When a chest X-ray shows consolidation but the question asks which finding is present, a medical vision-language model may answer "No consolidation." This is more than an incorrect choice: it is a polarity reversal that emits a clinical statement contradicting the image. We study this failure as negated-option attraction, where a model is drawn to a negated answer option even when it conflicts with both the visual evidence and the question. We introduce CXR-ContraBench (Chest X-Ray Contradiction Benchmark), a diagnostic benchmark spanning internal ReXVQA slices and external OpenI and CheXpert protocols. The benchmark centers on present-finding questions, where selecting "No X" despite visible X creates the main clinical risk, and uses absent-finding questions as secondary tests of whether models copy negated wording. Across CheXpert protocols, the failure is substantial and persistent. On a strict direct presence probe, MedGemma and Qwen2.5-VL reach only 31.49% and 30.21% accuracy, respectively; on a matched 135,754-record CheXpert training-split protocol, both models select negated options on over 62% of presence questions. Chain-of-thought prompting reduces some presence-side reversals but does not eliminate them and can amplify absence-side contradictions. Finally, QCCV-Neg (Question-Conditioned Consistency Verifier for Negation) deterministically repairs the measured polarity-confused subset without retraining, raising MedGemma and Qwen2.5-VL to 96.60% and 95.32% accuracy on the direct presence probe. These results show that standard accuracy can hide a clinically meaningful inference-time polarity failure. Source code and benchmark construction scripts are available at https://github.com/fangzr/cxr-contrabench-code.
Improving Imbalanced Multi-Label Chest X-Ray Diagnosis via CBAM-Enhanced CNN Backbones
Chest radiography is a widely used imaging modality for thoracic disease diagnosis, yet its conventional interpretation remains time-consuming and heavily dependent on expert knowledge. While deep learning has improved diagnostic efficiency through automated feature extraction, challenges such as class imbalance and the localization of multiple co-existing pathologies remain unsolved. In this paper, inspired by the strength of Convolutional Block Attention Module (CBAM) in feature refinement and the capability of CNN blocks in feature extraction, we propose a strategy to integrate CBAM into traditional CNN blocks to enhance performance in multi-label classification tasks. Our method achieves a mean AUC of 0.8695 on ChestXray14 dataset, outperforming several state-of-the-art baselines.Our source code is available at: https://github.com/NNNguyenDuyyy/FETC_CBAM_Enhanced_CNN.git
Momentum-Anchored Multi-Scale Fusion Model for Long-Tailed Chest X-Ray Classification
Chest X-ray classification suffers from severe class imbalance where gradient updates bias toward majority classes, causing feature drift and poor performance on rare but critical pathologies. We propose a Momentum-Anchored Multi-Scale Fusion Network that uses exponential moving averages (EMA) as a temporal anchoring mechanism to stabilize feature representations under long-tailed distributions. Our approach applies selective momentum updates to the final expansion block of an EfficientNet backbone, creating a slowly-evolving reference branch that resists gradient-induced drift while preserving discriminative patterns for minority classes. Combined with multi-scale spatial fusion (, , convolutions), this anchoring strategy maintains representational stability throughout training. On ChestX-ray14, our method achieves 0.8682 average AUC, outperforming state-of-the-art approaches and showing particular improvements on rare pathologies like Hernia (0.9470) and Pneumonia (0.8165). The results demonstrate that momentum anchoring effectively counters feature instability in long-tailed medical image classification.
Are Data Augmentation and Segmentation Always Necessary? Insights from COVID-19 X-Rays and a Methodology Thereof
Purpose: Rapid and reliable diagnostic tools are crucial for managing respiratory diseases like COVID-19, where chest X-ray analysis coupled with artificial intelligence techniques has proven invaluable. However, most existing works on X-ray images have not considered lung segmentation, raising concerns about their reliability. Additionally, some have employed disproportionate and impractical augmentation techniques, making models less generalized and prone to overfitting. This study presents a critical analysis of both issues and proposes a methodology (SDL-COVID) for more reliable classification of chest X-rays for COVID-19 detection. Methods: We use class activation mapping to obtain a visual understanding of the predictions made by Convolutional Neural Networks (CNNs), validating the necessity of lung segmentation. To analyze the effect of data augmentation, deep learning models are implemented on two levels: one for an augmented dataset and another for a non-augmented dataset. Results: Careful analysis of X-ray images and their corresponding heat maps under expert medical supervision reveals that lung segmentation is necessary for accurate COVID-19 prediction. Regarding data augmentation, test accuracy significantly drops beyond a certain threshold with additional augmented images, indicating model overfitting. Conclusion: Our proposed methodology, SDL-COVID, achieves a precision of 95.21% and a lower false negative rate, ensuring its reliability for COVID-19 detection using chest X-rays.
CheXthought: A global multimodal dataset of clinical chain-of-thought reasoning and visual attention for chest X-ray interpretation
Chest X-ray interpretation is one of the most frequently performed diagnostic tasks in medicine and a primary target for AI development, yet current vision-language models are primarily trained on datasets of paired images and reports, not the cognitive processes and visual attention that underlie clinical reasoning. Here, we present CheXthought, a global, multimodal resource containing 103,592 chain-of-thought reasoning traces and 6,609,082 synchronized visual attention annotations across 50,312 multi-read chest X-rays from 501 radiologists in 71 countries. Our analysis reveals clinical reasoning patterns in how experts deploy distinct visual search strategies, integrate clinical context, and communicate uncertainty. We demonstrate the clinical utility of CheXthought across four dimensions. First, CheXthought reasoning significantly outperforms state-of-the-art vision-language model chain-of-thought in factual accuracy and spatial grounding. Second, visual attention data used as an inference-time hint recovers missed findings and significantly reduces hallucinations. Third, vision-language models trained on CheXthought data achieve significantly stronger pathology classification, visual faithfulness, temporal reasoning and uncertainty communication. Fourth, leveraging CheXthought's multi-reader annotations, we predict both human-human and human-AI disagreement directly from an image, enabling transparent communication of case difficulty, uncertainty and model reliability. These findings establish CheXthought as a resource for advancing multimodal clinical reasoning and the development of more transparent, interpretable vision-language models.
When To Adapt? Adapting the Model or Data in Federated Medical Imaging
Federated learning enables collaborative model training across medical institutions without sharing raw data, but its performance is often limited by domain heterogeneity across clients. Existing approaches to address this challenge fall into two main paradigms: model-side personalization, which adapts model parameters to each client, and data-side harmonization, which reduces inter-client variation at the input level. Despite their widespread use, these strategies have not been systematically compared. In this work, we conduct a comprehensive study across six medical imaging settings-colon polyp, skin lesion, and breast tumor segmentation, and tuberculosis CXR, brain tumor, and breast tumor classification-covering diverse types of domain shift. We evaluate a broad set of state-of-the-art harmonization and personalization methods under a unified framework. Our results reveal a conditional trade-off driven by the nature of heterogeneity: harmonization is more effective when variation is primarily appearance-based (e.g., CXR classification), while personalization performs better when differences are structural (e.g., colon polyp segmentation). When inter-client variation is limited, both strategies perform similarly. These findings demonstrate that the effectiveness of adaptation in federated medical imaging depends on the type and magnitude of domain shift rather than the strategy alone. We provide practical guidelines for selecting between harmonization and personalization and highlight directions for future hybrid approaches that combine both paradigms. Code is available at https://github.com/ChamaniS/WhenToAdapt.
Quantum Kernel Advantage over Classical Collapse in Medical Foundation Model Embeddings
We provide evidence of quantum kernel advantage under noiseless simulation in binary insurance classification on MIMIC-CXR chest radiographs using quantum support vector machines (QSVM) with frozen embeddings from three medical foundation models (MedSigLIP-448, RAD-DINO, ViT-patch32). We propose a two-tier fair comparison framework in which both classifiers receive identical PCA-q features. At Tier 1 (untuned QSVM vs. untuned linear SVM, C = 1 both sides), QSVM wins minority-class F1 in all 18 tested configurations (17 at p < 0.001, 1 at p < 0.01). The classical linear kernel collapses to majority-class prediction on 90-100% of seeds at every qubit count, while QSVM maintains non-trivial recall. At q = 11 (MedSigLIP-448 plateau center), QSVM achieves mean F1 = 0.343 vs. classical F1 = 0.050 (F1 gain = +0.293, p < 0.001) without hyperparameter tuning. Under Tier 2 (untuned QSVM vs. C-tuned RBF SVM), QSVM wins all seven tested configurations (mean gain +0.068, max +0.112). Eigenspectrum analysis reveals quantum kernel effective rank reaches 69.80 at q = 11, far exceeding linear kernel rank, while classical collapse remains C-invariant. A full qubit sweep reveals architecture-dependent concentration onset across models. Code: https://github.com/sebasmos/qml-medimage
SparseContrast: Dynamic Sparse Attention for Efficient and Accurate Contrastive Learning in Medical Imaging
We propose SparseContrast, a new framework that merges dynamic sparse attention with contrastive learning for medical imaging, with a focus on chest X-ray disease detection in low-data settings. Traditional contrastive learning methods rely on dense attention mechanisms, which are computationally expensive and often process redundant regions in medical images. To resolve this, SparseContrast introduces a sparse attention mechanism that selectively concentrates on diagnostically pertinent areas, markedly decreasing computational burden without compromising accuracy. The framework adaptively trims attention maps in the training phase, directed by a compact saliency predictor which concurrently optimizes sparsity and feature quality. This method not only speeds up training and inference by as much as 40% relative to dense attention benchmarks but also boosts diagnostic accuracy by focusing on areas of clinical importance. Moreover, the approach remains indifferent to the selection of backbone architecture, which permits its application to both convolutional and transformer-based models. Experiments show SparseContrast attains comparable or better performance in disease identification tasks with greater efficiency relative to current approaches. The proposed framework delivers a practical approach for implementing contrastive learning in medical imaging settings with limited resources, where computational efficiency and diagnostic accuracy are paramount.
CheXmix: Unified Generative Pretraining for Vision Language Models in Medical Imaging
Recent medical multimodal foundation models are built as multimodal LLMs (MLLMs) by connecting a CLIP-pretrained vision encoder to an LLM using LLaVA-style finetuning. This two-stage, decoupled approach introduces a projection layer that can distort visual features. This is especially concerning in medical imaging where subtle cues are essential for accurate diagnoses. In contrast, early-fusion generative approaches such as Chameleon eliminate the projection bottleneck by processing image and text tokens within a single unified sequence, enabling joint representation learning that leverages the inductive priors of language models. We present CheXmix, a unified early-fusion generative model trained on a large corpus of chest X-rays paired with radiology reports. We expand on Chameleon's autoregressive framework by introducing a two-stage multimodal generative pretraining strategy that combines the representational strengths of masked autoencoders with MLLMs. The resulting models are highly flexible, supporting both discriminative and generative tasks at both coarse and fine-grained scales. Our approach outperforms well-established generative models across all masking ratios by 6.0% and surpasses CheXagent by 8.6% on AUROC at high image masking ratios on the CheXpert classification task. We further inpaint images over 51.0% better than text-only generative models and outperform CheXagent by 45% on the GREEN metric for radiology report generation. These results demonstrate that CheXmix captures fine-grained information across a broad spectrum of chest X-ray tasks. Our code is at: https://github.com/StanfordMIMI/CheXmix.
CXRMate-2: Structured Multimodal Temporal Embeddings and Tractable Reinforcement Learning for Clinically Acceptable Chest X-ray Radiology Report Generation
Chest X-ray (CXR) radiology report generation (RRG) models have shown rapid progress on automated metrics, yet their clinical utility remains uncertain due to limited qualitative evaluation by radiologists. We present CXRMate-2, a state-of-the-art CXR RRG model that enables tractable reinforcement learning (RL) through structured multimodal temporal embeddings and high-resolution visual feature compression, for efficient, unified conditioning of an LLM decoder on visual, textual, and temporal context from a study and its prior. This enables group relative policy optimisation (GRPO), where a proposed reward function is used to improve semantic alignment with radiologist reports. Across the MIMIC-CXR, CheXpert Plus, and ReXgradient datasets, CXRMate-2 achieves statistically significant improvements over strong benchmarks, including gains of 11.2% and 24.4% in GREEN and RadGraph-XL, respectively, on MIMIC-CXR relative to MedGemma 1.5 (4B). To directly compare CXRMate-2 against radiologist reporting, we conduct a blinded, randomised qualitative retrospective evaluation. Three consultant radiologists compare generated and radiologist reports across 120 studies from the MIMIC-CXR test set. Generated reports were deemed acceptable (defined as preferred or rated equally to radiologist reports) in 45% of ratings, with no statistically significant difference in preference rates for seven of the eight analysed findings. Preferences for radiologist reports were driven primarily by higher recall, while generated reports were consistently preferred for readability. Together, these results define a clear pathway to clinically acceptable CXR RRG. Improving recall and the detection of subtle findings represents the primary remaining barrier to non-inferiority with radiologist reporting, positioning CXR RRG for prospective evaluation in assistive, radiologist-led workflows.
ProtoCLIP: Prototype-Aligned Latent Refinement for Robust Zero-Shot Chest X-Ray Classification
Zero-shot vision-language models (VLMs) have shown promise for chest radiograph classification, but their performance is often limited by confounding label co-occurrence, long-tail class imbalance, and transfer instability under domain shift. We propose ProtoCLIP, a refinement strategy for CLIP-style VLMs that improves zero-shot discrimination through targeted data curation and distilled anchor alignment. Specifically, we construct pathology-focused training subsets with curated negative samples to reduce co-occurrence bias. We also introduce a representation-preserving distillation objective to stabilize adaptation while maintaining semantic structure and improving discrimination of clinically relevant co-occurring pathologies. Evaluated on an unseen dataset VinDr-CXR, ProtoCLIP improves AUC by 2-10 percentage points over a strong CLIP-based baseline across multiple findings. For pneumothorax specifically, ProtoCLIP achieves a state-of-the-art AUC of 0.94. These results demonstrate that anchor-guided refinement, coupled with curated supervision and controlled adaptation, can mitigate common zero-shot transfer failures in medical VLMs without requiring large-scale retraining.
CXR-LT 2026 Challenge: Multi-Center Long-Tailed and Zero Shot Chest X-ray Classification
Chest X-ray (CXR) interpretation is hindered by the long-tailed distribution of pathologies and the open-world nature of clinical environments. Existing benchmarks often rely on closed-set classes from a single institution, failing to capture the prevalence of rare diseases or the appearance of novel findings. To address this, we present the CXR-LT challenge. The first event, CXR-LT 2023, established a large-scale benchmark for long-tailed multi-label CXR classification and identified key challenges in rare disease recognition. CXR-LT 2024 further expanded the label space and introduced a zero-shot task to study generalization to unseen findings. Building on the success of CXR-LT 2023 and 2024, this third iteration of the benchmark introduces a multi-center dataset comprising over 145,000 images from PadChest and NIH Chest X-ray datasets. Additionally, all development and test sets in CXR-LT 2026 are annotated by radiologists, providing a more reliable and clinically grounded evaluation than report-derived labels. The challenge defines two core tasks this year: (1) Robust Multi-Label Classification on 30 known classes and (2) Open-World Generalization to 6 unseen (out-of-distribution) rare disease classes. This paper summarizes the overview of the CXR-LT 2026 challenge. We describe the data collection and annotation procedures, analyze solution strategies adopted by participating teams, and evaluate head-versus-tail performance, calibration, and cross-center generalization gaps. Our results show that vision-language foundation models improve both in-distribution and zero-shot performance, but detecting rare findings under multi-center shift remains challenging. Our study provides a foundation for developing and evaluating AI systems in realistic long-tailed and open-world clinical conditions.
RadJEPA: Radiology Encoder for Chest X-Rays via Joint Embedding Predictive Architecture
Vision-language pretraining has driven progress in medical image representation learning, but it depends on paired image-text data and can inherit reporting bias from clinical narratives. We study whether language-free predictive pretraining can produce an image encoder that transfers effectively to radiology report generation. RadJEPA is a chest-X-ray adaptation of I-JEPA, pretrained on approximately 840K unlabeled radiographs using latent context-to-target prediction. Our primary contribution is an extensive empirical evaluation of this language-free encoder for report generation: the frozen image encoder is coupled to a trainable two-layer projector and language decoder, and is also substituted into four established vision-language backbones. Across MIMIC-CXR and IU-Xray, RadJEPA matches or exceeds the evaluated image-only and image-text baselines on lexical, entity-relation, and clinical-label metrics. Controlled MIMIC-only comparisons provide evidence that the predictive objective contributes beyond domain-specific pretraining, while broader comparisons also reflect differences in pretraining data, model capacity, and input resolution. Complementary classification and segmentation experiments assess transfer beyond report generation.
CXRAgent: Director-Orchestrated Multi-Stage Reasoning for Chest X-Ray Interpretation
Chest X-ray (CXR) plays a pivotal role in clinical diagnosis, and a variety of task-specific and foundation models have been developed for automatic CXR interpretation. However, these models often struggle to adapt to new diagnostic tasks and complex reasoning scenarios. Recently, LLM-based agent models have emerged as a promising paradigm for CXR analysis, enhancing model's capability through tool coordination, multi-step reasoning, and team collaboration, etc. However, existing agents often rely on a single diagnostic pipeline and lack mechanisms for assessing tools' reliability, limiting their adaptability and credibility. To this end, we propose CXRAgent, a director-orchestrated, multi-stage agent for CXR interpretation, where a central director coordinates the following stages: (1) Tool Invocation: The agent strategically orchestrates a set of CXR-analysis tools, with outputs normalized and verified by the Evidence-driven Validator (EDV), which grounds diagnostic outputs with visual evidence to support reliable downstream diagnosis; (2) Diagnostic Planning: Guided by task requirements and intermediate findings, the agent formulates a targeted diagnostic plan. It then assembles an expert team accordingly, defining member roles and coordinating their interactions to enable adaptive and collaborative reasoning; (3) Collaborative Decision-making: The agent integrates insights from the expert team with accumulated contextual memories, synthesizing them into an evidence-backed diagnostic conclusion. Experiments on various CXR interpretation tasks show that CXRAgent delivers strong performance, providing visual evidence and generalizes well to clinical tasks of different complexity. Code and data are valuable at this link.
Revisiting Performance Claims for Chest X-Ray Models Using Clinical Context
Public datasets of Chest X-Rays (CXRs) have long been a popular benchmark for developing machine learning (ML) computer vision models in healthcare. However, the reported strong average-case performance of these models do not necessarily reflect their actual utility when used in heterogeneous clinical settings, potentially masking weaker performance in medically significant scenarios. In this work we use clinical context to provide a more holistic evaluation of models for CXR diagnosis. In particular, we use discharge summaries, recorded prior to each CXR, to derive a ``pre-CXR'' probability of each CXR label, as a proxy for existing contextual knowledge available to clinicians when interpreting CXRs. We use this measure to probe model performance along two dimensions: First, using a stratified analysis, we show that models tend to have lower performance (as measured by AUROC and other metrics) among individuals with higher pre-CXR probability. Second, by controlling for pre-CXR probability via matching and re-weighting, we demonstrate that performance degrades when the correlation is broken between prior context and the current CXR label, suggesting that model performance is highly sensitive to the underlying distribution of clinical context. Specifically, cases with high pre-test probabilities present a fundamentally more difficult visual classification task, highlighting a gap in clinical utility when models are applied to high-risk cohorts.
Anatomy-Grounded Weakly Supervised Prompt Tuning for Chest X-ray Latent Diffusion Models
Latent Diffusion Models have shown remarkable results in text-guided image synthesis in recent years. In the domain of natural (RGB) images, recent works have shown that such models can be adapted to various vision-language downstream tasks with little to no supervision involved. On the contrary, text-to-image Latent Diffusion Models remain relatively underexplored in the field of medical imaging, primarily due to limited data availability (e.g., due to privacy concerns). In this work, focusing on the chest X-ray modality, we first demonstrate that a standard text-conditioned Latent Diffusion Model has not learned to align clinically relevant information in free-text radiology reports with the corresponding areas of the given scan. Then, to alleviate this issue, we propose a fine-tuning framework to improve multi-modal alignment in a pre-trained model such that it can be efficiently repurposed for downstream tasks such as phrase grounding. Our method sets a new state-of-the-art on a standard benchmark dataset (MS-CXR), while also exhibiting robust performance on out-of-distribution data (VinDr-CXR). We further validate our approach through a pilot qualitative study and an experiment on grounded disease classification. Our code will be made publicly available at https://github.com/vios-s.