Ultrasound Image Segmentation
Momentum
5 papers in the last four weeks, against 2 the four weeks before. 0.0% of all new papers.
Latest papers 44
Multi-structure segmentation of the uterus is important for computer-assisted screening, diagnosis, and treatment planning of uterine diseases, where ultrasound and MRI provide complementary clinical information. However, developing a unified model across these modalities is challenging due to their substantially different image appearances, anatomical contexts, spatial resolutions, and label spaces. Moreover, existing datasets often define different segmentation targets, making joint learning challenging and potentially leading to negative transfer across heterogeneous tasks. To this end, we propose a Topology-informed Prompt-conditioned Universal Segmentation (TPUS) framework for segmenting multiple uterine structures across ultrasound and MRI. TPUS introduces a graph-based multi-dataset backbone comprising modality-specific stems and a modality-shared graph-based encoder-decoder to support modality-sensitive input adaptation, structural feature reasoning, and joint representation learning across heterogeneous uterine segmentation tasks. In addition, TPUS uses task-aware class prompts to condition the segmentation process for different datasets and label spaces, a dynamic convolutional adaptation module to generate task-specific output responses, and a topology-informed loss to encourage anatomically consistent predictions. Experiments on a uterine ultrasound dataset and a T2-weighted uterine myoma MRI dataset demonstrate that TPUS achieves Dice scores of 0.898 and 0.693 on the two held-out test sets, respectively, outperforming several generic and universal segmentation baselines. Source code can be accessed at https://github.com/YonghengSun1997/TPUS.
UltraBench 2: Towards Robust Evaluation of Vision Foundation Models on Ultrasound
Benchmarking is an increasingly critical part of research in machine learning and the domains where it is applied, including healthcare. Yet, despite the steady development of new ultrasound foundation models in recent years, the development of well-designed benchmarks to evaluate them has lagged behind. This deficiency has led to fragmented and inconsistent evaluations of competing models, making it difficult to measure progress. To address this issue, we introduce UltraBench 2, a comprehensive benchmark with wide anatomical and task coverage, and a focus on standardization, reproducibility, and ease-of-use. Using this benchmark, we compare existing vision foundation models for ultrasound image analysis. Our analyses demonstrate that ultrasound-specific pretraining still leads on classification, but that state-of-the-art general-purpose models have drawn level on segmentation.
FreqDINO++: A Frequency-Guided Multi-Task Routing Vision Foundation Model for Universal Ultrasound Analysis
Ultrasound image analysis plays a crucial role in cancer screening and prenatal diagnosis, yet comprehensive assessment requires jointly addressing tasks such as lesion segmentation and benign-malignant classification. While recent vision foundation models have shown remarkable universal representations, unlocking their potential for ultrasound is bottlenecked by the considerable domain gap from natural images. Existing methods typically fine-tune heavy vision encoders for isolated tasks, incurring substantial computational overhead while overlooking the underlying commonalities across heterogeneous tasks. In this work, we propose FreqDINO++, a frequency-guided multi-task routing vision foundation model for universal ultrasound analysis. We first introduce a Multi-task Routing Adapter (MR-Adapter) to support parameter-efficient integration of task-common and task-specific knowledge, a Frequency-aware Feature Enhancer (F-Enhancer) is then designed to capture the rich multi-scale frequency characteristics of ultrasound images, and a Task-aligned Collaborative Decoder (TC-Decoder) is devised to promote collaboration between dense and global prediction tasks through global-local token interaction. Extensive experiments on large-scale multi-task and external single-task ultrasound benchmarks demonstrate that FreqDINO++ consistently outperforms strong baselines and recent foundation models across 27 diverse clinical task scenarios, while also showing promising generalization to unseen data. The code is at https://github.com/MingLang-FD/FreqDINO-Plus.
Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings
Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13% versus 18--42%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code.
Physics-Guided Synthetic High-Frequency Ultrasound Generation for Skin Layer Segmentation
High-frequency ultrasound (HFUS) enables noninvasive visualization of superficial skin structures, but automated skin-layer analysis is limited by the scarcity of densely annotated data. Existing real HFUS datasets commonly provide annotations for superficial targets such as the epidermis and subepidermal low-echogenic band (SLEB), while dense labels for deeper structures such as dermis, subcutaneous tissue, fascia, and muscle are rarely available. We propose a physics-guided synthetic HFUS generation framework for skin layer segmentation. The framework constructs multilayer acoustic skin phantoms, assigns layer dependent acoustic properties, and uses k-Wave simulation to generate paired synthetic HFUS images, dense layer masks, and simulation metadata. To evaluate whether the generated data provide transferable supervision, we use it for downstream segmentation pretraining and fine-tune the models on real Mendeley HFUS data. Synthetic pretraining followed by real fine-tuning achieved real-domain performance comparable to real-only training and improved mean Dice/IoU in three of four evaluated trainable architectures. These results suggest that physics-guided synthetic HFUS images contain transferable anatomical and textural cues for real-domain skin layer segmentation, although further reduction of the synthetic-real appearance gap is needed to enable greater gains. The code and data are available at: https://github.com/Finn-02/synthetic-hfus-skin-layer-segmentation.
A Quantitative Evaluation Framework for Temporal Explainability in Echocardiographic Video Segmentation
Deep learning has achieved state-of-the-art performance in echocardiographic video segmentation, with an increasing number of models incorporating temporal information. However, quantitative evaluation of temporal explainability remains largely unexplored. We propose a quantitative framework for evaluating Grad-CAM explanations using four complementary metrics measuring temporal consistency, saliency motion, anatomical overlap, and temporal overlap. Using EchoNet-Dynamic, we compare a baseline 2D U-Net with ConvLSTM U-Net models trained across multiple temporal strides. While segmentation performance remained comparable across all models, intermediate ConvLSTM explanations exhibited substantially lower saliency consistency and greater centroid motion than final prediction explanations. Temporal Bottleneck explanations were significantly more stable than Encoder Bottleneck explanations across all strides, while final ConvLSTM Decoder3 explanations were broadly comparable to those of the 2D U-Net. Importantly, conventional frame-wise explanation metrics cannot determine whether variation in intermediate explanations reflects meaningful temporal feature evolution or explanation instability. These findings establish a preliminary quantitative framework for temporal explainability and motivate temporal-aware XAI methods that explicitly account for evolving representations in medical video models.
Expert-like Bone Ultrasound Segmentation through Expert-in-the-loop Mask-conditioned Progressive Learning
Manual annotation remains a major bottleneck in ultrasound (US) bone segmentation, where experts typically iteratively refine rough brush masks rather than delineating precise contours in a single pass. We present ExiL, a mask-conditioned progressive learning framework that models annotation as a structured refinement trajectory. ExiL combines a synthetic expert-like brush simulator based on signed distance fields with a lightweight 7.8M-parameter U-Net that learns to complete and refine imperfect masks from US images. During deployment, an expert mode updates the model directly from accepted refinements, enabling continual adaptation to expert behavior. Evaluated using UltraBones100k cadaver data for quantitative segmentation and a prospective volunteer dataset for annotation-efficiency analysis, ExiL reduced single-expert average annotation time from 60 to 20 seconds per frame (66.7%) and improved mean Dice by approximately 0.045 over non-progressive training, while achieving 0.87 Dice and 2.7 px boundary error in the best trajectory-aware setting. With 10--50 ms inference, ExiL enables real-time, self-improving annotation for US-guided orthopedic workflows in practical clinical labeling.
VIDS-Seg: Towards Reliable Uncertainty Quantification in Pediatric Cardiac Ultrasound Segmentation
Reliable clinical deployment of machine learning requires models that know when they are likely to fail, particularly for subgroups underrepresented in training data. A common case is pediatric care, where models trained on adult cohorts can silently under-perform on children with no indication that something has gone wrong. As retraining with labeled pediatric data is often infeasible, detecting such failures at inference time is a critical clinical need. Building on the VIDS (Variational Inference under Distribution Shifts) framework, we introduce VIDS-Seg, which applies amortized variational inference over a lightweight prediction head to make this adaptive, OOD-aware prior tractable for dense image segmentation. We evaluate VIDS-Seg on left ventricular segmentation in echocardiography, a setting where pediatric anatomy differs systematically from the adult population most segmentation models are trained on, training on an adult cohort (EchoNet-Dynamic) and evaluating zero-shot on a pediatric cohort (EchoNet-Pediatric). Across all age strata, VIDS-Seg matches competitive baselines in segmentation accuracy while producing substantially higher spatial correspondence between predicted uncertainty and segmentation error, an advantage that persists even after applying temperature scaling to all baselines. Downstream, it yields more accurate and stable ejection fraction estimates and more reliable detection of cardiac malfunction in the infant subgroup. Our results indicate that OOD-aware uncertainty quantification can serve as a practical safety layer for deployed segmentation models, enabling detection of silent failures in underrepresented subgroups without retraining or additional labeled data.
BAP-MOS: Bandit-Based Adaptive Prompting for Boundary-Sensitive Multi-Organ Segmentation
Multi-organ ultrasound segmentation remains challenging when anatomically adjacent structures must be delineated jointly, as localized boundary errors can persist even when Dice scores are high. To address these challenges, we propose Boundary-Adaptive Prompting for Multi-Organ Segmentation (BAP-MOS), a closed-loop adaptive prompting framework. BAP-MOS formulates prompt selection as an organ-specific multi-armed bandit problem over box, point, and combined prompts. An outer Tree-structured Parzen Estimator (TPE) loop selects the prompt-selection parameter vector, while an inner UCB-Tuned loop adapts per-organ prompt preferences during fine-tuning using a bounded Dice--MSD--HD95 validation-probe reward. The framework further introduces an organ-scaled negative prompt ring to adapt sparse prompt geometry across anatomical scales, while keeping the image and prompt encoders frozen and updating only the mask decoder. We evaluate BAP-MOS on pooled prostate-region TRUS cohorts against U-Net, nnU-Net, MedSAM, fixed-prompt SAM/MedSAM, and adaptive policy variants. On this benchmark, BAP-MOS achieves Dice 0.982, HD95 0.482, and MSD 0.204, reducing HD95 by approximately 48% and MSD by 45% relative to the strongest conventional baseline. To verify the generalization ability of the framework, we tested it on the external PFUS1 pelvic-floor ultrasound corpus using MedSAM and its adaptive strategy variants, and the results were good. These results support adaptive prompt allocation as an effective mechanism for improving boundary-sensitive multi-organ ultrasound segmentation without modifying the foundation-model backbone. Source Code is available at: https://github.com/SatvikPraveen/BAP-MOS
UCBound-Net: Uncertainty-Guided Boundary-Aware Continual Learning for Domain-Incremental Ultrasound Segmentation
Continual learning in clinical imaging faces a dual challenge: a model must assimilate knowledge from new anatomical domains while retaining representations learned from prior tasks, a problem known as catastrophic forgetting. Existing mitigation strategies, including regularization and knowledge distillation, treat all spatial regions equally, ignoring the fact that prediction uncertainty is strongly correlated with the propensity for forgetting. We introduce UCBound-Net, a continual segmentation framework that exploits Monte Carlo (MC) Dropout uncertainty as a spatial proxy for forgetting risk. Our method contributes three synergistic components: (i) uncertainty-weighted boundary distillation, which amplifies the knowledge transfer signal at high-entropy regions of the frozen teacher; (ii) uncertainty-calibration regularization, which explicitly penalizes overconfident erroneous predictions; and (iii) uncertainty-guided exemplar selection, a memory buffer that preferentially stores samples whose boundary regions exhibit the highest predictive entropy. Evaluated on a sequential domain-incremental benchmark comprising breast ultrasound (BUSI, Task 1) followed by thyroid ultrasound (TN3K, Task 2), UCBound-Net reduces forgetting relative to naive fine-tuning, achieving a backward transfer (BWT) of -0.098 compared with -0.173, while obtaining an average Dice Similarity Coefficient (DSC) of 0.755 across both tasks. The proposed framework outperforms baseline methods without requiring task-boundary supervision. An ablation study further demonstrates that each component contributes independently to forgetting mitigation, providing a practical pathway toward uncertainty-aware continual learning for clinical image segmentation.
UltraSAM3: A Concept-Driven Foundation Model for Universal Ultrasound Image Segmentation
Ultrasound imaging has become increasingly widespread in clinical practice due to its portability, low cost and real-time capability, making ultrasound image segmentation important. However, ultrasound images differ substantially from CT, MRI, and other medical imaging modalities, as they are often affected by speckle noise, low contrast, acoustic shadows and ambiguous boundaries. Existing ultrasound segmentation methods are still mainly limited to task-specific models or visual-prompt-based foundation models, which are either tailored to particular tasks or require expert-provided visual prompts, making them inconvenient for flexible clinical use. To address these challenges, we propose UltraSAM3, a concept-driven foundation model for universal ultrasound image segmentation. Unlike conventional models, UltraSAM3 enables text-based target specification by adapting SAM3 to ultrasound-specific image--mask--concept triplets. The model is trained on a large-scale ultrasound segmentation corpus covering 37 public datasets and 13 anatomical categories, allowing it to align ultrasound visual patterns with clinically meaningful concepts across diverse organs and lesions. To further improve usability under realistic clinical interaction, we propose an instruction-guided agent that parses complex natural language queries into concise ultrasound concept prompts for UltraSAM3. Extensive experiments demonstrate that UltraSAM3 consistently outperforms representative concept- and text-driven biomedical segmentation models on multi-organ ultrasound benchmarks, external datasets, and visual-prompt-enhanced settings. Moreover, the agent improves segmentation robustness for complex user instructions. These results indicate that ultrasound-specific concept adaptation is effective for building generalizable and interactive ultrasound segmentation foundation models.
Learning-based Hierarchical Tracheal Anatomy Understanding from Sparse Surgical Demonstration Annotations for Ultrasound Robots
Tracheostomy requires precise localization of the tracheal incision site; however, conventional manual palpation is subjective and often unreliable, while ultrasound utility remains operator-dependent. This work presents a learning-based framework for hierarchical tracheal anatomy understanding, designed specifically for ultrasound-guided robotic systems. We propose a two-stage perception pipeline integrating a YOLOv8n localization backbone with a sparse, prompt-optimized SAM2 decoder to achieve high-fidelity segmentation from sparse surgical annotations. Our hybrid training strategy, bridging curated laboratory data with unconstrained sequences, ensures clinical robustness. Experimental benchmarks demonstrate that this decoupled architecture effectively balances generalization, precision, and efficiency. The YOLOv8n and SAM2 framework achieves a consistent Mean Dice Similarity Coefficient (DSC) of 0.777 across both controlled and generalized domains. This significantly outperforms U-Net baselines, which often suffer from anatomical fragmentation and performance degradation (Generalization DSC 0.494). By constraining mask decoding to targeted, sparse regions of interest, our model achieves a throughput of 6.92 FPS, which is vital for closed-loop robotic teleoperation. This study confirms that a robust hierarchical understanding of tracheal anatomy can be derived by coupling lightweight localization with foundation-scale visual models. Our framework establishes a scalable foundation for standardized, autonomous surgical assistance, effectively navigating the variability of real-world ultrasound to enhance the safety and precision of robotic-assisted tracheostomy.
Risk-Routed Implicit Boundary Refinement for Robust Ultrasound Image Segmentation
Medical ultrasound (US) image segmentation faces significant challenges due to speckle noise, low-contrast boundaries, acoustic shadowing, and acquisition variation across operators and clinical centers. Although encoder-decoder and transformer-based networks have achieved strong performance, many methods recover boundary details through dense decoders or larger backbones, which may still produce over-smoothed contours or unstable predictions under external distribution shifts. In this article, we propose Risk-routed Implicit Boundary Refinement (RIBR), a compact segmentation framework that uses implicit neural representation as a risk-routed residual correction rather than an unconstrained full-mask predictor. RIBR combines boundary-refinement implicit residuals, risk-routed residual control, and geometry- and speckle-aware boundary regularization to refine uncertain contours while suppressing non-boundary oscillations. Evaluation on nine US datasets covering lymph nodes, breast lesions, thyroid nodules, and prostate shows that RIBR achieves the best overall macro-average and consistently reduces boundary error across grouped and organ-specific comparisons under a compact parameter budget. These findings suggest that controlled implicit residual learning is a practical strategy for resource-constrained and boundary-sensitive US segmentation. Source code is available at https://github.com/jinggqu/ribr.
Domain Shift in Echocardiography: Interpretable Quantification and Prediction of Cross-Dataset Left Ventricular Segmentation
Cross-dataset generalisation remains a major barrier to clinical deployment of echocardiographic left ventricular segmentation, yet the sources of this shift are rarely disentangled. We examined whether transfer degradation could be estimated before deployment using handcrafted ultrasound descriptors, VAE latent features, and segmentation-derived latent features across six echocardiographic datasets. Geometry-aware preprocessing substantially improved several poor transfer cases, suggesting that much of the apparent domain shift reflects field-of-view and framing inconsistencies rather than intrinsic acoustic differences alone. Intensity z-normalisation changed dataset separability by less than 0.005, indicating that brightness and contrast are not the dominant shift axis. Absolute Dice drop on held-out source-target pairs was predicted with an R-squared value of 0.612, an MAE of 0.082, and a Spearman rho of 0.681. The variant without LV and fan-shaped features retained approximately 70% of this explanatory power, supporting mask-free transfer-risk monitoring. The most informative discrepancy measure depended on the representation, with CMD strongest in z-normalised handcrafted features, with an absolute r of approximately 0.86 and an R-squared value of approximately 0.70; log-Wasserstein strongest in VAE space, with an r of approximately -0.90 and an R-squared value of approximately 0.81; and log-MMD strongest in LV-segmentation latent features, with an r of approximately -0.92 and an R-squared value of approximately 0.84. Apparent vendor effects were largely dataset-confounded. Echocardiographic domain shift is therefore structured and measurable, and its impact on segmentation can be partly reduced through geometry-aware preprocessing and anticipated using representation-specific transfer-risk estimation.
OvAi Focus: AI-based Multi-class Segmentation of Functional Ovaries and Adnexal Masses in Gynecological Ultrasound
Ovarian cancer is the deadliest gynecological malignancy; accurate and objective segmentation of adnexal masses and functional ovaries in ultrasound (US) remains challenging due to operator variability and morphological complexity. We present OvAi Focus (SynDiag s.r.l., Italy), a stand-alone AI software medical device that performs multi-class semantic segmentation of functional ovaries and adnexal masses, distinguishing cystic from solid components. The system was trained and independently validated on a multicenter dataset of 1,081 adult women from 6 centers across Italy and Israel. Segmentation achieved DICE scores of 0.87 (complete lesion), 0.85 (cystic), 0.68 (solid), and 0.62 (functional ovary), in line with or superior to state-of-the-art approaches across heterogeneous acquisition settings.
Automatic Echocardiography Segmentation via Transition Probability Correlation for Stable Semantic Extraction
While echocardiography is essential for cardiovascular diagnosis, inherent speckle noise and low signal-to-noise ratio often lead to ambiguous semantic features and fragmented boundaries. These limitations significantly hinder the segmentation accuracy of deep learning models in complex clinical cases. Moreover, temporal motion of the heart plays a critical role in recognizing anatomical structures. To address these challenges, we designed a STLSF module which comprises a window-matching-based semantic correction component and a semantics-guided texture enhancement component. By leveraging local transition probability correlations to correct semantics and employing semantics-guided texture enhancement, the STLSF module effectively mitigates texture instability and ambiguous semantic interpretations caused by disadvantaged echocardiography quality. Additionally, to facilitate the encoder's adaptation to the intrinsic priors of ultrasound-specific imaging patterns, we propose a frequency-aware denoising pre-training method. The entire work builds a convolution-based network with locality inductive bias and long-range dependencies. Extensive experiments confirm our SOTA performance, achieving 93.87% Dice on CAMUS and 92.62% on EchoNet-Dynamic, with respective HD95 values of 3.29mm and 2.73mm.
An Edge-aware Prompt-enhanced SAM for Ultrasound Image Segmentation
Ultrasound image segmentation is essential for delineating anatomical structures and lesions, providing the foundation for accurate diagnosis. While the Segment Anything Model (SAM) has demonstrated remarkable success on natural images, its performance on ultrasound data is often hindered by poor boundary delineation. To address this limitation, we propose EP-SAM, an edge-aware and prompt-enhanced adaptation of SAM. Specifically, we leverage multi-block feature extraction from the image encoder to enrich coarse-to-fine semantic representations, while edge-aware supervision of the image encoder improves robustness to contour ambiguity and speckle noise. By integrating these complementary cues, EP-SAM generates high-quality prompts that effectively guide the model toward target regions of interest. Experimental results on multiple benchmarks demonstrate that EP-SAM consistently outperforms existing SAM-based methods.
Comparison of Loss Functions for Robust Deep Learning-based Echocardiography Segmentation when Learning with Partially Labelled Data from Multiple Domains
Echocardiography is the first imaging modality used for assessing cardiac function, and accurate segmentation of cardiac structures is essential for deriving biomarkers. However, the development of effective automated segmentation models for multiple cardiac structures is challenged by the difficulty of training on datasets from different sources that are often partially-labelled. This study aims to address this challenge by evaluating the performance of three loss functions - adaptive categorical cross entropy (aCCE) loss, marginal loss, and the adaptive binary cross entropy (aBCE) loss - in handling partially-labelled data. We conduct a comprehensive comparison of these loss functions across multiple scenarios and network architectures: intra-domain and inter-domain tasks, with both single and multiple partial-labels, and varying proportions of fully-labelled to partially-labelled data. Our experiments reveal that all three loss functions exhibit strong performance in intra-domain segmentation tasks, effectively handling label variations within the same domain. For inter-domain tasks, where models are trained on datasets with a domain shift, the aBCE and marginal losses show superior performance when dealing with the case of one label being missing from some training examples. In scenarios involving more than one label being missing, marginal loss outperforms the other methods, demonstrating its robustness in such complex conditions. These results highlight the strengths of each loss function depending on the labelling scenario, emphasizing the importance of selecting the appropriate loss function to optimize model performance. This study represents the first investigation of techniques for handling partially-labelled data from multiple different domains in echocardiography segmentation and provides a comprehensive comparison of loss-based solutions.
MedSaab-US: A Backpropagation-Free Multi-Scale Wavelet-Saab Framework for Thyroid Nodule Segmentation in Ultrasound Images
Deep learning (DL) methods dominate thyroid nodule segmentation in ultrasound (US) images, achieving high Dice scores but at the cost of millions of parameters, GPU-dependent training via backpropagation, and limited mathematical tractability. These limitations impede deployment in resource-constrained environments. In this paper, we propose MedSaab-US, a backpropagation-free segmentation framework grounded in the Green Learning paradigm. MedSaab-US extracts multi-scale spatial-frequency features by combining multi-level Discrete Wavelet Transform (DWT) with multi-scale channel-wise Saab (Subspace Approximation with Adjusted Bias) transforms at patch sizes of 5 x 5, 11 x 11, and 21 x 21 pixels. Label-Assisted Greedy (LAG) feature selection retains the most discriminative features, which are fed to an XGBoost classifier for pixel-wise prediction. The Saab transform parameters are determined analytically from data statistics, while XGBoost employs iterative greedy tree construction without requiring backpropagation. Evaluated on the TN3K dataset (2,879 training and 614 test images), MedSaab-US achieves a mean Dice coefficient of 0.4784 +/- 0.2190, precision of 0.5768, and recall of 0.5604, with a model footprint under 500K parameters and CPU-only inference in approximately 0.3 seconds per image. We present this result as an exploratory non-DL baseline for thyroid ultrasound segmentation and analyze the specific challenges posed by isoechoic nodules. An ablation study further quantifies the contribution of each pipeline component, including separate evaluations of LAG feature selection and training-set size.
RadiomicNet: A Hybrid Radiomics-Guided Lightweight Architecture for Interpretable Medical Image Segmentation
Deep learning has achieved remarkable performance in medical image segmentation, yet it suffers from critical limitations: mathematical intractability, substantial parameter requirements, and lack of clinical interpretability. We propose RadiomicNet, a novel two-stream hybrid architecture that enhances standard deep learning by integrating handcrafted radiomics features directly into the segmentation learning process. The key contribution is the Radiomics Attention Gate (RAG), which leverages Gray-Level Co-occurrence Matrix (GLCM) and Local Binary Pattern (LBP) features to modulate skip-connection attention in a lightweight MobileNetV2-based encoder-decoder, providing ante-hoc interpretability without post-hoc approximations. A novel Radiomics Consistency Loss further enforces alignment between texture complexity and prediction uncertainty, reducing Expected Calibration Error (ECE) from 0.142 to 0.118. RadiomicNet achieves a Dice Similarity Coefficient (DSC) of 0.763 +/- 0.231 on the Breast Ultrasound Images (BUSI) dataset and 0.854 +/- 0.112 on Kvasir-SEG, outperforming U-KAN by 1.2% and 1.8%, respectively (p < 0.05, Wilcoxon signed-rank test), with only 3.27M parameters, 9.5x fewer than standard U-Net and 4.3x fewer than U-KAN. Gradient-based feature importance analysis reveals that GLCM dissimilarity (15.24%), GLCM energy (14.56%), and LBP entropy (11.49%) are the dominant radiomics cues, providing clinically meaningful explanations for segmentation decisions. The proposed approach demonstrates that compact, interpretable models grounded in domain knowledge can deliver state-of-the-art segmentation performance with substantially reduced computational overhead.
Self-Supervised Temporal Regularization for Landmark-Based Cardiac Segmentation with Automatic AHA Regional Mapping
Graph-based cardiac segmentation with implicit anatomical correspondences provides topological guarantees and population-level analysis capabilities, but models trained on independent frames of image sequences exhibit temporal discontinuities that affect reliable clinical measurements, particularly in cardiac ultrasound. In this work, we introduce self-supervised temporal regularization as a post-training refinement stage that exploits the temporal coherence in image sequences to enforce consistent cardiac segmentation and motion estimation over time, without requiring per-frame annotations. By penalizing velocity and acceleration discontinuities across consecutive frames, our method achieves temporally consistent segmentations while maintaining the learned anatomical correspondences. We further leverage these correspondences to automatically map landmarks to the AHA 17-segment clinical standard, enabling standardized regional assessment and detection of pathological myocardial motion patterns. Validation on CAMUS dataset demonstrates the clinical utility of combining temporal consistency with automatic regional mapping. The code is publicly available at https://github.com/david-montalvoo/MaskHybridGNet-TempReg
Distilling Temporal Coherence into 2D Networks for Transrectal Ultrasound Prostate Video Segmentation
Real-time video segmentation of the prostate in Transrectal Ultrasound (TRUS) is essential for image-guided interventions. While conventional 2D methods suffer from inter-frame inconsistencies by disregarding temporal context, 3D architectures incur prohibitive latency. To resolve this dilemma, we present a Temporally Consistent Learning Framework that distills temporal coherence into a 2D network during training, preserving single-frame inference efficiency. Our design is driven by a key clinical observation: the prostate exhibits geometric stability, whereas the surrounding acoustic environment fluctuates due to physiological motion and transducer pressure. Because conventional temporal constraints propagate erroneous gradients from these unstable regions, we introduce a Confidence-Weighted Temporal Consistency objective derived from optical flow warping residuals, selectively attenuating contributions from unreliable regions. Complementing this pixel-wise constraint, a Dual-scale Prototype Alignment Module enforces semantic coherence through contrastive optimization of local boundary and global semantic features. Furthermore, to eliminate the need for dense per-frame video annotations, we employ geometric equivariance-based pseudo-labeling with knowledge distillation from a pretrained teacher. Extensive experiments on SUN-SEG and our newly introduced TRUS-V benchmark (2,679 frames) demonstrate state-of-the-art accuracy and temporal consistency at real-time speed. Code and dataset are available at https://github.com/DYDevelop/DTC-TRUS.
Dual Agreement Consistency Learning for Semi-Supervised Fetal Ultrasound Segmentation
Maternal-fetal US is the primary imaging modality for monitoring fetal development, yet accurate automated segmentation remains challenging due to the scarcity of pixel-level annotations. To address this issue, we propose DACL, a semi-supervised framework for robust fetal US image segmentation. DACL jointly trains a deployment-oriented lightweight convolutional network (1.47\thinsp\mathrm{M} parameters) and a Transformer-based network, leveraging labeled data for supervised learning and unlabeled data via CPS. To enhance prediction stability, we introduce a dual-agreement consistency loss that couples pixel-wise probabilistic divergence with entropy-guided confidence alignment. Unlike conventional CPS methods that enforce agreement only at the prediction level, DACL explicitly regularizes both distributional alignment and uncertainty, thereby suppressing unreliable pseudo-labels and enabling stable cross-architecture pseudo-label learning under extreme annotation scarcity. Furthermore, an interpolation-based consistency strategy using mixup is applied to unlabeled samples to enhance robustness. Under 5% labeled data, DACL improves Dice by up to 2.77% and reduces HD95 by up to 14.69 mm compared with the strongest recent semi-supervised methods, demonstrating significant improvements in boundary accuracy on both fetal head and abdomen datasets. These results demonstrate the effectiveness of agreement-based consistency learning for annotation-efficient fetal US segmentation. Our code is on GitHub.
Evaluating self-supervised echocardiographic representations across downstream extraction strategies for left-ventricular segmentation and ejection fraction estimation
Self-supervised learning (SSL) is increasingly used in medical imaging to reduce annotation requirements, but representation quality is often judged using a single downstream evaluation setting. For dense clinical tasks, this can confound representation quality with the capacity of the downstream model used to recover task-relevant information. We present a systematic evaluation of self-supervised representations for left-ventricular segmentation and ejection fraction (EF) estimation from apical four-chamber echocardiography on EchoNet-Dynamic. Rather than relying on a single downstream probe, we compare a hierarchy of extraction strategies with increasing expressivity: heuristic extraction without mask-supervised training, frozen linear probes, frozen lightweight decoder probes, and partial fine-tuning. We apply this framework to two complementary representation families: generic frozen self-DIstillation with NO labels (DINOv3) features and a task-adapted dense self-supervised representation, Bootstrap Your Own Segmentation (BYOS). In both families, heuristic extraction substantially understated what was recoverable from the frozen representation. For DINOv3, performance improved from Dice 0.684 and EF mean absolute error (MAE) 13.01 under heuristic extraction to Dice 0.906 and EF MAE 9.65 with a frozen lightweight decoder, approaching a supervised U-Net baseline (Dice 0.915, EF MAE 9.72). For BYOS, performance improved from Dice 0.687 and EF MAE 17.83 under heuristic extraction to Dice 0.902 and EF MAE 8.74 with a frozen lightweight decoder. These results show that conclusions about self-supervised representation quality in dense echocardiographic analysis depend strongly on the downstream extraction strategy used for evaluation. We therefore argue that multi-strategy evaluation is an important methodological consideration for SSL in dense medical image analysis.
Specificity- and Calibration-Aware Breast Ultrasound Segmentation via Entropy-Guided Boundary Supervision
Lesion segmentation in breast ultrasound involves two related challenges. In images with lesions, speckle noise, low tissue contrast, and posterior acoustic shadowing cause boundary leakage and incomplete contour delineation. In images without lesions, those same artifacts generate false-positive activations in regions resembling solid lesion tissue. This study addresses both failure modes through a single modification to the training objective. Rather than weighting every boundary pixel equally, the proposed loss scales contour penalties by per-pixel predictive entropy and the ground-truth boundary map, concentrating gradient emphasis on lesion margin locations where the network remains uncertain. The loss was evaluated on the BUSI dataset through a controlled ablation against two baselines: a model without boundary supervision and a model with uniformly weighted boundary binary cross-entropy. Across 97 lesion-containing test images, mean Dice scores were statistically indistinguishable between the proposed method and the no-boundary baseline (0.7624 versus 0.7616, paired Wilcoxon p = 0.27), confirming that lesion segmentation quality is preserved. The primary effect appears in specificity. False-positive activations on 20 no-lesion test images fell from 14 of 20 and 19 of 20 for the two baselines to 5 of 20 with the proposed approach (McNemar p = 0.012 and 0.0005). Non-overlapping Wilson 95% confidence intervals confirm the difference is both statistically significant and practically substantial. A post-hoc spatial temperature scaling step further reduced expected calibration error from 0.0201 to 0.0095 without altering segmentation masks. Entropy-guided boundary supervision and spatial calibration thus function as complementary training-level and inference-level refinements that improve specificity and probability reliability within a U-Net framework.
Clinically Aligned Geometry Constraints for Robust IVUS Vessel Boundary Segmentation
Intravascular ultrasound (IVUS) lumen and external elastic membrane (EEM) segmentation is important for quantitative coronary plaque burden assessment. Errors in lumen or EEM delineation directly propagate to plaque area, plaque burden and geometric measurements. However, standard methods prioritising overlap scores often suffer from boundary drift and topology errors, leading to inaccurate clinical measurements. We present GeoCat, a geometry-consistent network that processes 5-frame IVUS clips using dual Cartesian-polar encoders with cross-domain attention and temporal fusion. A differentiable geometry consistency loss directly supervises clinically relevant descriptors including diameters, orientations, and cross-sectional areas. The model is trained on 12,242 annotated frames from 146 patients acquired with two commercial IVUS systems. We evaluate performance using both segmentation accuracy and plaque-relevant clinical metrics, including Dice/IoU, boundary measures(95HD (mm), ASSD), topology violation rate, and clinical geometry errors (dmax/dmin, angles, and areas). On our dataset, GeoCat achieves a Dice of 0.93, reduces 95HD to 0.14 mm, and lowers topology violations to 1.0%. Importantly, it significantly improves geometric fidelity, yielding diameter errors of 0.13-0.16 mm and angular errors of ~8 degrees, supporting reliable plaque burden quantification.
Enabling Real-Time Point-of-Care Ultrasound Segmentation: A GPU-Free Deployment in Resource-Limited Settings
Ultrasound imaging is the most widely adopted medical modality globally due to its low cost and portability, yet artificial intelligence (AI) deployment remains constrained by reliance on GPU-accelerated models, creating a structural paradox where the cost of "intelligence" exceeds that of the imaging device itself. Here, we present the systematic adaptation and extensive evaluation of UltraSeg, an ultra-lightweight architecture originally developed for colonoscopic polyp segmentation, now engineered for point-of-care ultrasound (POCUS) across ten public datasets spanning six anatomical sites (breast, thyroid, kidney, carotid, fetal, and small-animal tumor). We systematically validate both variants in ultrasound domains: UltraSeg-130K (0.13M parameters) achieves 89.7 FPS on single-core CPUs and 34.8 FPS on a refurbished mobile device, while UltraSeg-500K (0.5M parameters) delivers 44.6 FPS on CPU and 16.1 FPS on mobile device. UltraSeg-500K matches or exceeds the Dice performance of the 31M-parameter UNet and approaches 105M-parameter TransUNet in average performance, with superior zero-shot cross-dataset generalization on external validation sets (UDIAT, DDTI). By enabling clinical-grade segmentation without GPU dependency, this work brings AI costs in line with ultrasound accessibility, making advanced diagnostics available in resource-limited settings.
FADA: Accessible fetal ultrasound interpretation and annotation with a selectively distilled unified vision-language model
A global shortage of trained sonographers limits prenatal ultrasound screening in low- and middle-income countries, where over half of pregnant women receive no skilled sonography. Current deep learning approaches address detection, segmentation, or classification in isolation, each demanding a separate model and expert-specified labels at inference. We present FADA, a unified vision-language model built on Qwen3.5-VL that performs clinical interpretation, classification, detection, and segmentation through a single interpretation-first pipeline without external labels. FADA distills knowledge from four domain-specific foundation models (FetalCLIP, UltraSAM, USF-MAE, UltraFedFM) via offline pre-computed feature caching. Selective distillation, which applies feature alignment only to annotation tasks while interpretation relies on standard fine-tuning, consistently outperforms full distillation across most evaluation axes. The recommended variant, FADA-SKD, achieves 0.8820 mean Dice for segmentation, 0.7671 [email protected] for detection, and 100% structured interpretation compliance. Expert sonographer validation across 237 images confirms clinically acceptable outputs in both autonomous and human-in-the-loop modes, with 73.5% of interpretations scoring perfectly under clinician guidance. The system is trainable on a single consumer GPU and deployable without cloud connectivity. We validate edge deployment by running the compressed 0.8B model on a commodity smartphone (Qualcomm Snapdragon 7 Gen 1, 12 GB RAM) using llama.cpp with GGUF quantization, completing the full 5-phase pipeline in approximately 60 seconds entirely offline. This establishes a practical pathway for integrating AI-assisted fetal assessment with portable ultrasound devices, directly addressing diagnostic access gaps in resource-constrained settings. Code, models, and data are available at https://github.com/mahmoodphd/FADA.
FSS-Net: Frequency-Spatial Synergy Network with Wavelet Attention for Carotid Artery Ultrasound Segmentation
Accurate segmentation of carotid arteries in ultrasound imaging is critical for stroke risk assessment. However, speckle noise, low contrast, and blurred boundaries remain major challenges. In this paper, we propose a Frequency-Spatial Synergy Network (FSS-Net) to achieve noise-robust and high-precision carotid artery segmentation. The network integrates wavelet transform, multi-domain attention, and edge enhancement into a unified encoder-decoder architecture. Specifically, a Channel-Spatial-Wavelet Attention (CSWA) module is designed to suppress noise and purify semantic features in the frequency domain. A Wavelet-Enhanced Bottleneck (WEB) module is introduced to capture long-range global dependencies efficiently. Furthermore, a Laplacian-Guided Adaptive Edge Fusion (LAEF) module compensates high-frequency details and maintains boundary continuity. Extensive experiments on carotid ultrasound datasets show that FSS-Net achieves a Dice score (DSC) of 96.46% and strong robustness under low SNR conditions, outperforming several state-of-the-art methods. This method realizes accurate segmentation of carotid artery in ultrasonic imaging, effectively identifies carotid atherosclerotic plaque, and is verified by other task (such as segmentation of breast cancer), suggesting that it has good clinical application potential in identifying abnormal tissue masses in ultrasonic images.
MVSegNet: A Lightweight Boundary-Aware Network for Fetal Lateral Ventricle Segmentation and Atrial Width Estimation in Prenatal Ultrasound
Fetal ventriculomegaly is assessed by measuring the atrial width of the lateral ventricle in prenatal ultrasound. Accurate segmentation is essential for this measurement, but acoustic shadowing, speckle noise, and poor contrast make it difficult. We developed MVSegNet, a lightweight encoder-decoder network combining multi-scale feature extraction and boundary-aware refinement. The model was trained and evaluated on 584 expert-annotated transventricular ultrasound frames using a 70/15/15 split. Performance was compared against six segmentation baselines using overlap, boundary, and measurement metrics. MVSegNet achieved a Dice score of 80.79%, IoU of 68.47%, Hausdorff distance of 4.07 mm, and atrial width mean absolute error of 3.40 mm. The model contains 2.31 million parameters and runs at 165.6 frames per second on an NVIDIA T4 GPU. MVSegNet outperformed all evaluated baselines on boundary and measurement metrics while maintaining low computational cost, supporting its use in automated fetal ultrasound analysis.