AR in Surgery

AR: Augmented Reality

Latest papers

14 papers1 paper in the last four weeks, with none the four weeks before. 0.0% of all new papers.

Oct 8, 2026

Multimodal Image-based Robotic Assistance and Guidance Environment (MIRAGE): A Novel Unified Framework for Surgical Navigation and Visualization

This paper presents the computational architecture and quantitative preclinical evaluation of MIRAGE, a multimodal image-guided robotic surgery framework for real-time visualization and navigation. It integrates stereovision scene reconstruction, augmented-reality (AR) video overlay, quantified heads-up display (HUD) navigation, and intraoperative ultrasound within the da Vinci console's TilePro display (Intuitive Surgical). Additional modules include optical/electromagnetic tracker registration, stereo calibration, fiducial rigid registration with RMSE feedback, and 3D point-cloud reconstruction. Video I/O and rendering run in a C++ backend, while a Python GUI coordinates calibration, registration, reconstruction, visualization, and user interaction through an in-process zero-copy binding layer. The framework formalizes spatial transforms, module states, and synchronization of heterogeneous video and tracking streams. Preoperative calibration uses synchronized checkerboard image pairs and optimization, with estimated intrinsics, extrinsics, and rectification reused intraoperatively. MIRAGE was validated in phantom experiments across da Vinci S, Si, Xi, and SP platforms. Across clinically relevant working distances, mean 3D reprojection error was 0.6mm, with best 0.1mm RMSE at 100mm on Xi. Results support MIRAGE as a preclinical technical-validation platform for accurate, responsive, and extensible multimodal surgical guidance.
Aug 6, 2026

Toward surface-based registration of a virtual preoperative cutting guide onto the mandible for reconstruction surgery

Mandibular reconstruction restores facial continuity and oral function after segmental resection. Patient-specific cutting guides transfer a computed tomography (CT)-based plan to the operating room with three-dimensional information, but printed guides add cost and lead time, cannot adapt after fabrication, and may interrupt surgery if sterility is lost. We investigate a markerless augmented reality (AR) alternative that registers a virtual cutting guide to the exposed mandible from surface geometry. The method extends surface-based registration for the transoral setting, where teeth form the most distinctive visible surface. After camera calibration, a HoloLens 2 time-of-flight camera captures a partial intraoperative point cloud. The user supplies a rough head-based alignment only to crop the region of interest. A teeth-weighted global stage computes correspondences and solves a truncated least-squares rigid alignment. An asymmetric point-to-plane iterative closest point (ICP) stage refines the complete CT mandible against the partial depth cloud target. The guide-to-mandible transform places the guide in the HoloLens world frame, while pose updates and interpolation follow target motion. We define a blinded phantom protocol with 30 target registration error (TRE) points under full, intermediate, and teeth-only exposure, plus a motion-to-display latency test. Our median TRE is 4.05, 6.10, and 7.10 mm respectively, and median latency is 0.805 s. These values support the feasibility of using AR to replace physical prints. The workflow removes mounted fiducials and manual landmark selection and provides a testable path toward transoral cutting guidance.
Jul 31, 2026

Real-Time Visual Obstruction Detection in Surgical Augmented Reality

Surgical augmented reality (AR) can provide contextual guidance by overlaying virtual annotations, tool cues, and procedural information onto the surgical workspace. However, the virtual content may obstruct task-relevant real-world information, such as surgical instruments, and interfere with users' perception during time-sensitive surgical tasks. In this paper, we investigate visual obstruction detection for surgical AR and present a latency-aware pipeline that combines vision-language model (VLM)-based surgical-object recognition with segmentation-based obstruction reasoning. To reduce inference overhead, the system adopts a cascaded small-to-large VLM architecture with segmentation-guided early exiting and attention-based visual token pruning. The small VLM handles easy frames when its key-object prediction is supported by segmentation consistency, while difficult frames are forwarded to a large VLM with pruned visual tokens. We construct a pseudo-AR surgical obstruction detection benchmark by overlaying virtual content onto surgical-tool images and labeling whether the virtual content obstructs task-relevant instruments. Evaluation results show that the proposed system achieves 87.43% obstruction detection accuracy with an average end-to-end latency of 479 ms, reducing latency by 62.90% compared with a cloud large-model baseline. These results demonstrate the feasibility of latency-aware obstruction detection for surgical AR and motivate future work on dynamic surgical videos, multi-object scenes, and clinically grounded AR guidance content.
Jul 15, 2026

Marker-free deformable registration and fusion for augmented reality-guided positive margin localization during tumor resection surgery

Positive margins in head and neck oncologic surgery require mapping specimen-side pathology findings to the patient resection bed. This is challenging because pathologists identify the positive margin on slices of the resected, deformed specimen, while surgeons must relocate the corresponding site on the resection bed using only verbal descriptions and no visual guidance. We present a marker-free augmented reality (AR) workflow for mapping a margin label from a three-dimensional specimen scan to the resection bed. The method combines contour-constrained deformation, residual alignment to a depth scan, surface-based fusion to a head-mounted display, and target projection onto the reconstructed bed. Bead-suture correspondences estimate specimen deformation, whereas patient-to-display fusion does not require external fiducial markers. Following formative experiments, five residents and surgeons performed cadaveric cheek and scalp re-resection tasks under verbal guidance, verbal guidance with specimen examination, and AR guidance. Deformation target errors were 7.63±3.747.63 \pm 3.74 mm for the cheek and 3.72±1.023.72 \pm 1.02 mm for the scalp; residual specimen-to-bed distances were 2.43±2.152.43 \pm 2.15 mm and 2.19±1.062.19 \pm 1.06 mm, respectively. Fusion error did not differ significantly between marker-free and marker-based methods on either cadaver; overall marker-free fusion error was 2.15±0.872.15 \pm 0.87 mm. End-to-end margin localization error decreased from 21.40±3.8421.40 \pm 3.84 mm with verbal guidance and 16.09±4.3016.09 \pm 4.30 mm with specimen examination to 6.19±1.796.19 \pm 1.79 mm with AR guidance (p<0.001p < 0.001). Online fusion required 5.23±0.345.23 \pm 0.34 s. These results demonstrate effective marker-free AR guidance for positive-margin localization and support more precise tumor resection.
Jul 12, 2026

X-GuideAR: An Augmented Reality Framework to Mitigate Radiation Exposure during Fluoroscopic Guidance

Achieving optimal screw placement for orthopedic surgeries requires frequent alignment checks and multiple anatomical views under X-ray -- a process known as "fluoro-hunting" that increases radiation exposure to patients and surgical teams. This work introduces X-GuideAR, an augmented reality (AR) framework for identifying optimal X-ray views, aimed at reducing radiation exposure while ensuring accurate screw placement. To exemplify the benefits of X-GuideAR, we focus on S2 alar-iliac (S2AI) screw placement. Our system provides radiation-free guidance for view acquisition and drilling by generating synthetic X-ray previews that accelerate fluoro-hunting. Once the required anatomical views are identified using these previews, a real X-ray is acquired, and the preview of the drilling trajectory is augmented onto it, facilitating precise screw placement with minimal additional radiation. A preliminary study involving eight S2AI trajectories performed by an expert spine surgeon demonstrated a 62.3% reduction in the number of X-rays. Post-procedure evaluations showed that trajectories done with X-GuideAR supported an average safe screw diameter of 12.95 mm compared to 5.9 mm under the conventional workflow, suggesting improved bony containment and potential biomechanical benefit. X-GuideAR shows great potential to reduce radiation exposure and streamline S2AI screw placement, offering a promising direction toward safer and more efficient surgeries.
Jun 18, 2026

Evaluation of Augmented Reality-based Intuitive Interface for Robot-Assisted Transesophageal Echocardiography: A User Study

TransEsophageal Echocardiography (TEE) is essential for diagnosing and guiding Structural Heart Disease (SHD) interventions. However, manual TEE manipulation demands significant operator expertise, is physically demanding, and exposes clinicians to radiation when performed alongside fluoroscopy. Robotic-assisted TEE systems have been introduced to improve probe handling and reduce operator fatigue, yet the design of intuitive and effective user interfaces remains an open challenge. This study presents and evaluates a model-enhanced, Augmented Reality (AR)-based intuitive interface for robot-assisted TEE, designed to improve spatial awareness and control intuitiveness. A robotic TEE platform integrated with electromagnetic tracking and a virtual simulator was used to compare three user interfaces differing in visualization and interaction modalities: 2D jointlevel (2D-JI), 3D joint-level (3D-JI), and 3D tip-level (3D-TI). Thirty six participants performed standardized navigation tasks to reproduce target echocardiographic views, with performance assessed via position and orientation errors, completion time, and NASA-TLX workload scores. Results show that 3D visualization significantly improved spatial accuracy, reducing median position error from 13 mm to 3 mm and halving the orientation error compared with the 2D interface. Tip-level interaction yielded a further 50% reduction in orientation error and reduced interuser variability relative to joint-level control. Overall, the 3D-TI configuration, combining immersive visualization with direct tip-level control, proved the most effective and ergonomic interface, supporting the integration of AR-based visualization and intuitive control paradigms into next-generation robotic TEE systems to enhance operator performance and procedural safety.
Jun 3, 2026

Multi-Camera AR Guidance System for Surgical Instrument Handling and Assembly: Investigating Workload and Efficiency

The handling and assembly of instruments during surgery imposes high cognitive demands on scrub nurses, particularly when instruments are unfamiliar. We present a supporting guidance system for surgical instrumentation that combines multi-camera 6D pose estimation with augmented reality in-situ visualization on a head-mounted display without the requirement for additional markers. Pose estimation and consecutive camera calibration are achieved through known objects. The 6D pose estimation network is trained purely on synthetic data, aiming for better generalizability and real-world applicability. The AR guidance displays tooltip localization cues and step-wise assembly animations. Via gaze-based selection and a foot pedal, users can switch between assembly steps in intraoperative use. In a technical evaluation, our approach outperforms state-of-art 6D pose estimation. A user study with 29 scrub nurses was conducted in a surgical simulation of knee arthroplasty, comparing the system against a paper manual. AR guidance significantly reduced the perceived workload compared. Objectively, AR guidance reduced task completion time by 21.3% (4.76 minutes). Specifically, scrub nurses less experienced with the instrument set benefited when using the system. Error frequencies were comparable between conditions. Qualitative feedback highlighted improved process clarity, reduced information overload, and perceived independence. To summarize, our marker-free multi-camera AR guidance approach for surgical instruments can, subjectively and objectively, improve intraoperative instrumentation performance, particularly for untrained scrub nurses.
Apr 11, 2026

Warm-Started Reinforcement Learning for Iterative 3D/2D Liver Registration

Registration between preoperative CT and intraoperative laparoscopic video plays a crucial role in augmented reality (AR) guidance for minimally invasive surgery. Learning-based methods have recently achieved registration errors comparable to optimization-based approaches while offering faster inference. However, many supervised methods produce coarse alignments that rely on additional optimization-based refinement, thereby increasing inference time. We present a discrete-action reinforcement learning (RL) framework that formulates CT-to-video registration as a sequential decision-making process. A shared feature encoder, warm-started from a supervised pose estimation network to provide stable geometric features and faster convergence, extracts representations from CT renderings and laparoscopic frames, while an RL policy head learns to choose rigid transformations along six degrees of freedom and to decide when to stop the iteration. Experiments on a public laparoscopic dataset demonstrated that our method achieved an average target registration error (TRE) of 15.70 mm, comparable to supervised approaches with optimization, while achieving faster convergence. The proposed RL-based formulation enables automated, efficient iterative registration without manually tuned step sizes or stopping criteria. This discrete framework provides a practical foundation for future continuous-action and deformable registration models in surgical AR applications.
Mar 31, 2026

SurgNavAR: An Augmented Reality Surgical Navigation Framework for Optical See-Through Head Mounted Displays

Augmented reality (AR) devices with head mounted displays (HMDs) facilitate the direct superimposition of 3D preoperative imaging data onto the patient during surgery. To use an HMD-AR device as a stand-alone surgical navigation system, the device should be able to locate the patient and surgical instruments, align preoperative imaging data with the patient, and visualize navigation data in real time during surgery. Whereas some of the technologies required for this are known, integration in such devices is cumbersome and requires specific knowledge and expertise, hampering scientific progress in this field. This work therefore aims to present and evaluate an integrated HMD-based AR surgical navigation framework that is adaptable to diverse surgical applications. The framework tracks 2D patterns as reference markers attached to the patient and surgical instruments. It allows for the calibration of surgical tools using pivot and reference-based calibration techniques. It enables image-to-patient registration using point-based matching and manual positioning. The integrated functionalities of the framework are evaluated on two HMD devices, the HoloLens 2 and Magic Leap 2, with two surgical use cases being evaluated in a phantom setup: AR-guided needle insertion and rib fracture localization. The framework was able to achieve a mean tooltip calibration accuracy of 1 mm, a registration accuracy of 3 mm, and a targeting accuracy below 5 mm on the two surgical use cases. The framework presents an easy-to-use configurable tool for HMD-based AR surgical navigation, which can be extended and adapted to many surgical applications. The framework is publicly available at https://github.com/abdullahthabit/SurgNavAR.
Mar 31, 2026

All-in-One Augmented Reality Guided Head and Neck Tumor Resection

Positive margins are common in head and neck squamous cell carcinoma, yet intraoperative re-resection is often imprecise because margin locations are typically communicated verbally from pathology. We present an all-in-one augmented reality (AR) system that relocalizes positive margins from a resected specimen to the resection bed and visualizes them in situ using HoloLens 2 depth sensing and fully automated markerless surface registration. In a silicone phantom study with six medical trainees, markerless registration achieved target registration errors comparable to a marker-based baseline (median 1.8 mm vs. 1.7 mm; maximum < 4 mm). In a margin relocalization task, AR guidance reduced error from verbal guidance (median 14.2 mm) to a few millimeters (median 3.2 mm), with all AR localizations within 5 mm error. These results support the feasibility of markerless AR margin guidance for more precise intraoperative re-excision.
Mar 23, 2026

Feasibility of Augmented Reality-Guided Robotic Ultrasound with Cone-Beam CT Integration for Spine Procedures

Accurate needle placement in spine interventions is critical for effective pain management, yet it depends on reliable identification of anatomical landmarks and careful trajectory planning. Conventional imaging guidance often relies both on CT and X-ray fluoroscopy, exposing patients and staff to high dose of radiation while providing limited real-time 3D feedback. We present an optical see-through augmented reality (OST-AR)-guided robotic system for spine procedures that provides in situ visualization of spinal structures to support needle trajectory planning. We integrate a cone-beam CT (CBCT)-derived 3D spine model which is co-registered with live ultrasound, enabling users to combine global anatomical context with local, real-time imaging. We evaluated the system in a phantom user study involving two representative spine procedures: facet joint injection and lumbar puncture. Sixteen participants performed insertions under two visualization conditions: conventional screen vs. AR. Results show that AR significantly reduces execution time and across-task placement error, while also improving usability, trust, and spatial understanding and lowering cognitive workload. These findings demonstrate the feasibility of AR-guided robotic ultrasound for spine interventions, highlighting its potential to enhance accuracy, efficiency, and user experience in image-guided procedures.
Mar 17, 2026

Patient4D: Temporally Consistent Patient Body Mesh Recovery from Monocular Operating Room Video

Recovering a dense 3D body mesh from monocular video remains challenging under occlusion from draping and continuously moving camera viewpoints. This configuration arises in surgical augmented reality (AR), where an anesthetized patient lies under surgical draping while a surgeon's head-mounted camera continuously changes viewpoint. Existing human mesh recovery (HMR) methods are typically trained on upright, moving subjects captured from relatively stable cameras, leading to performance degradation under such conditions. To address this, we present Patient4D, a stationarity-constrained reconstruction pipeline that explicitly exploits the stationarity prior. The pipeline combines image-level foundation models for perception with lightweight geometric mechanisms that enforce temporal consistency across frames. Two key components enable robust reconstruction: Pose Locking, which anchors pose parameters using stable keyframes, and Rigid Fallback, which recovers meshes under severe occlusion through silhouette-guided rigid alignment. Together, these mechanisms stabilize predictions while remaining compatible with off-the-shelf HMR models. We evaluate Patient4D on 4,680 synthetic surgical sequences and three public HMR video benchmarks. Under surgical drape occlusion, Patient4D achieves a 0.75 mean IoU, reducing failure frames from 30.5% to 1.3% compared to the best baseline. Our findings demonstrate that exploiting stationarity priors can substantially improve monocular reconstruction in clinical AR scenarios.
Mar 9, 2026

Extend Your Horizon: A Device-Agnostic Surgical Tool Tracking Framework with Multi-View Optimization for Augmented Reality

Surgical navigation provides real-time guidance by estimating the pose of patient anatomy and surgical instruments to visualize relevant intraoperative information. In conventional systems, instruments are typically tracked using fiducial markers and stationary optical tracking systems (OTS). Augmented reality (AR) has further enabled intuitive visualization and motivated tracking using sensors embedded in head-mounted displays (HMDs). However, most existing approaches rely on a clear line of sight, which is difficult to maintain in dynamic operating room environments due to frequent occlusions caused by equipment, surgical tools, and personnel. This work introduces a framework for tracking surgical instruments under occlusion by fusing multiple sensing modalities within a dynamic scene graph representation. The proposed approach integrates tracking systems with different accuracy levels and motion characteristics while estimating tracking reliability in real time. Experimental results demonstrate improved robustness and enhanced consistency of AR visualization in the presence of occlusions.
Feb 19, 2026

Depth Augmented and FE Free 3D/2D Liver Registration for Laparoscopic Liver AR

Augmented reality (AR) guidance in laparoscopic liver surgery requires accurate registration of preoperative 3D models to intraoperative 2D video, but remains challenging due to partial visibility, specularities, and tissue deformation. Existing methods often rely on contour-based rigid initialization and finite-element (FE) models for deformable registration, increasing modeling and engineering complexity. We present a depth-augmented, FE-free 3D--2D registration pipeline that combines robust rigid initialization with patient-specific non-rigid refinement. For rigid alignment, we adapt the RefineNet module of FoundationPose to laparoscopic liver scenes by using multi-class contour maps and monocular depth for relative pose refinement. For deformable alignment, we construct a patient-specific statistical deformation model from non-rigid ICP (NICP) correspondences and optimize pose and shape parameters using a coarse-to-fine L-BFGS-B strategy. On a public clinical laparoscopic liver dataset, the proposed method achieves a mean target registration error (TRE) of 14.73,mm under a controlled manual-contour setting designed to isolate registration performance. Ablation studies show that monocular depth improves rigid initialization over contour-only inputs, while tumor-mapping analysis indicates that good surface alignment does not necessarily translate into lower target localization error. On an external dataset without ground truth, the method produces visually plausible overlays for qualitative assessment. These results suggest that depth-augmented pose refinement and FE-free statistical deformation modeling provide a promising alternative to FE-based pipelines for controlled 3D--2D liver registration in surgical AR.