Medical Image Classification
Latest papers 486
53 papers in the last four weeks, up 8% on the four weeks before. 0.3% of all new papers.
Early detection of oral cancer markedly improves clinical outcomes, yet specialized diagnostic tools remain scarce in low-resource settings. Smartphone-based screening is a scalable alternative but needs lightweight models that run within edge-hardware constraints. Hybrid classical-quantum architectures are emerging candidates for parameter-efficient learning, yet most rely on qubit hardware that needs cryogenic operation, unsuitable for edge deployment. Continuous-variable (CV) photonic quantum computing, which operates at room temperature, offers a complementary route. We investigate a hybrid classical-CV quantum classifier for oral cancer detection from smartphone images. The pipeline combines a MobileNetV1 feature extractor, principal component analysis to 16 dimensions, and a parameterized CV-QNN of displacement, interferometric, and Kerr gates on a photonic backend. We propose a simplified CV-QNN architecture that cuts trainable parameters 40-45% relative to the standard CV-QNN layer of Killoran et al. (2019a), and identify dimensionality-reduction and encoding-restriction strategies that mitigate barren plateaus, raising loss-gradient variance by roughly 58 orders of magnitude. Whether the simplified layer beats the full layer is width-dependent: the full layer holds a small but significant edge at two qumodes, whereas the simplified layer is significantly better at four qumodes using 44% fewer parameters. The strongest model, a four-qumode simplified CV-QNN with only 18 parameters, attains the highest validation AUC of all models, exceeds a 55-parameter classical baseline using 67% fewer parameters, and reaches 100% calibrated test accuracy across all seeds. These results support CV photonic quantum machine learning for parameter-efficient, room-temperature medical image classification and motivate progress toward edge quantum AI.
MedDiffuseMix: Preserving Diagnostic Evidence with Saliency-Aware Diffusion Medical Image Data Augmentation
Limited data availability, class imbalance, and domain variability remain major barriers to reliable medical image classification. Conventional augmentation can improve training diversity but may distort diagnostically informative structures, whereas unconstrained generative augmentation may introduce label-inconsistent content. This paper proposes MedDiffuseMix, a saliency-guided diffusion mixing framework for controlled medical image augmentation. The method uses classifier-derived saliency maps to separate high-saliency diagnostic regions from low-saliency background areas and applies diffusion-guided mixing mainly to regions with lower diagnostic importance. Adaptive mixing, Gaussian boundary blending, and a saliency-preservation constraint reduce semantic distortion and reject or attenuate samples that shift model attention away from clinically relevant evidence. The framework is evaluated on four public benchmarks: the Radiological Society of North America pneumonia chest radiography dataset, Musculoskeletal Radiographs, PatchCamelyon, and the Breast Cancer Histopathological Image Classification dataset. Experiments with convolutional and transformer-based classifiers show that MedDiffuseMix improves accuracy, F1-score, and area under the receiver operating characteristic curve compared with standard augmentation, Mixup, GenMix, SaliencyMix, and diffusion-based augmentation baselines. Ablation studies confirm the importance of saliency guidance, adaptive region mixing, and smooth boundary blending. Visual attribution analysis further indicates that MedDiffuseMix better preserves diagnostically salient regions. These results suggest that saliency-guided diffusion mixing is an effective augmentation strategy for limited-data medical image classification.
Intracranial Aneurysm Classification and Segmentation via Tri-Axial ROI and Multi-Task Learning
Intracranial aneurysms are often asymptomatic until rupture, which carries high mortality. Rupture risk assessment and treatment planning depend on both aneurysm morphology and anatomical location, yet existing automated methods remain limited to binary detection without fine-grained anatomical classification or multi-class segmentation. We present a multi-task framework that simultaneously performs multi-label classification, multi-class aneurysm segmentation, and multi-class vessel segmentation across 13 anatomical locations and four imaging modalities (CTA, MRA, T2, T1-post). Our two-stage approach combines a fast 2D tri-axial Region of Interest (ROI) extraction method with a 3D multi-task nnU-Net backbone. A dual-decoder design mitigates the extreme volume imbalance between aneurysm and vessel classes, while cross-attention pooling and modality-specific auxiliary heads improve feature learning across heterogeneous inputs. Our two-fold ensemble achieved 2nd place in the RSNA 2025 Intracranial Aneurysm Detection challenge. Code, model weights, and a 3D Slicer plugin are publicly available.
Disease-Centric Vision-Language Pretraining with Hybrid Visual Encoding for 3D Computed Tomography
Vision-language pre-training (VLP) holds great promise for general-purpose medical AI by leveraging radiology reports as rich textual supervision, yet existing methods struggle with 3D CT imaging due to inefficient visual backbones and coarse semantic alignment. To address these issues, we propose a tailored VLP framework featuring three key components: (1) a CNN-ViT hybrid encoder that replaces ViT's patch embedding with a 3D CNN backbone to efficiently capture local anatomical details while preserving global attention and compatibility with pre-trained cross-modal priors; (2) a disease-level contrastive learning mechanism using learnable query tokens to dynamically extract disease-specific semantics from full reports and align them with corresponding visual features, thereby disentangling distinct diseases within the same anatomical region; and (3) a diagnosis-aware prompt strategy that employs real clinical phrases and aggregated disease prototypes to bridge the pre-training-inference gap and enhance zero-shot diagnostic reliability. Our model achieves state-of-the-art performance on CT-RATE (84.4% AUC, +5.1%) and Rad-ChestCT (75.4% AUC, +5.4%), with even larger gains (+9.8% AUC) on a challenging 60-disease benchmark, and demonstrates strong transferability to radiology report generation, underscoring the generality and clinical utility of our approach.
A Leakage-Aware Comparative Benchmark of Machine Learning, Deep Learning, and Transformer Models for Reliable Leukemia Detection
Automated classification of acute lymphoblastic leukemia (ALL) from peripheral blood smear images has often reported near-perfect performance on the C-NMC 2019 dataset. We show that such results can be inflated by patient-level data leakage caused by random image-level partitioning, where cells from the same subject may appear in both training and test folds. We establish a leakage-aware benchmark under a strict subject-disjoint protocol, comparing LightGBM, RBF-SVM, EfficientNet-B0, EfficientNet-B1, and ViT-Tiny. Models are developed using three subject-disjoint folds from 73 subjects and evaluated on an external preliminary-phase test set of 1,867 images from 28 unseen subjects with zero patient overlap. Beyond discrimination, we assess calibration using expected calibration error, Brier score, and temperature scaling. Under honest evaluation, EfficientNet-B1 achieves the best performance, with AUROC 0.913, sensitivity 0.87, specificity 0.80, and calibrated ECE 0.024. Frozen-feature classifiers and ViT-Tiny show high sensitivity but poor specificity, indicating a tendency to over-predict the malignant class. A random-versus-subject-disjoint ablation shows that random splitting inflates AUROC by about 0.04 even in the conservative frozen-feature setting. These findings caution against image-level evaluation on C-NMC 2019 and provide a reproducible, calibration-aware benchmark for future work.
Brain-Adapter: A Dual-Stream Vision-Language MIL Framework for Comprehensive 3D CT Diagnosis of Acute Intracranial Pathologies
Automated diagnosis of 3D brain CT scans is essential for critical care, yet it remains challenging due to the heavy reliance on manual annotations and the limited semantic understanding of conventional models. While 2D foundation vision-language models (VLMs) have shown remarkable generalization, effectively transferring their representational power to 3D volumes remains an open problem. In this paper, we propose Brain-Adapter, a novel dual-stream multiple instance learning (MIL) framework that leverages pre-trained 2D biomedical VLMs and raw diagnostic reports for robust scan-level multi-label classification. Specifically, we introduce a Text-Conditioned Attention (TCA) mechanism, utilizing raw diagnostic sentences as semantic queries to dynamically align visual cues with specific disease concepts. Concurrently, a parallel visual MIL stream captures global scan characteristics, supervised by structured labels extracted via a Large Language Model (LLM). To ensure representation coherence, a consistency constraint enforces synergy between the two streams. During inference, an Uncertainty-Aware Refinement (UAR) module dynamically calibrates and fuses these dual-stream predictions to resolve ambiguous cases. Extensive experiments demonstrate that our method significantly outperforms state-of-the-art 3D models and standard MIL approaches. By eliminating the reliance on dense annotations, Brain-Adapter provides a highly scalable and clinically viable solution for 3D acute intracranial pathology analysis.
IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection
The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.
Biological Sex Determination in Cadavers Using Deep Learning Algorithms from Computed Tomography Images of Pelvis and Skull
Sexual identification of decomposed cadavers challenges traditional methods dependent on visual anthropological analysis. This study evaluates state-of-the-art deep learning (including YOLO26, YOLO11, ConvNeXt-Tiny, EfficientNetV2, ViT-B16, VGG16, and ResNet50) with transfer learning to automatically determine biological sex from forensic computed tomography (CT) scans. We analyzed 141 autopsied cadavers from the Forensic Medical Institute of Goiânia-GO, including a broad age range and varying conditions of preservation. The three-dimensional reconstructions of the pelvis and skull were converted into standardized two-dimensional profile projections, contributing to the study of this new technical approach. Data augmentation techniques compensated for sample limitations. Two scenarios were validated: binary and quaternary classification (one class per sex vs. one class per anatomical region of each sex). The best-performing model achieved highly consistent results on the pelvis region and still satisfactory performance on the skull region, reaching an overall patient-level accuracy of 95.65%, recall of 92.86%, F1- score of 94.36%, and precision of 97.22%, maintaining consistent performance across the evaluated cases, including those with trauma-related artifacts. Results indicate the technical feasibility of the methodology, demonstrating that deep learning models can provide objective, high-speed skeletal analysis. Since the study was conducted using data from a single institution and a single computed tomography scanner, further validation across multiple centers and scanners is required to assess the generalizability of the proposed approach
Multi-cancer detection using a computationally efficient CNN with transfer learning
This study introduces a computationally efficient convolutional neural network (CNN) architecture enhanced with transfer learning for multi-cancer detection using biomedical images. The proposed lightweight CNN model is designed to reduce computational complexity while maintaining high classification performance, making it suitable for deployment in resource-constrained environments. We evaluate this approach on three distinct tumor datasets comprising brain magnetic resonance imaging (MRI) and lung and kidney computed tomography (CT) scans. The model achieves test accuracy of 90.85 +- 2.22%, 98.64 +- 2.43% and 99.92 +- 0.08% for brain, lung, and kidney cancer classification, respectively, using 5-fold stratified cross-validation (CV). Transfer learning is employed by pretraining the model on one cancer type and fine-tuning it on the others, requiring only 20 additional epochs to achieve performance comparable to models trained from scratch. The fine-tuning process involves updating the classification part of the CNN and requires approximately 0.014 seconds per image per epoch using an NVIDIA GeForce GTX 960. Comparative evaluations show that the proposed model outperforms several state-of-the-art pretrained architectures, such as Xception, VGG16, VGG19, MobileNetV2 and DenseNet121. Overall, the model's effectiveness is evaluated across three types of cancer with distinct morphological characteristics, assessing its performance on both MRI and CT imaging modalities and demonstrating robust performance across diverse tasks and data types. These findings underscore the potential of streamlined deep learning (DL) frameworks in accelerating cancer diagnosis without sacrificing accuracy, especially in settings with limited computational resources.
One-Shot Data Selection for Medical Image Classification via Graph Coverage
Training medical image classifiers on entire datasets is wasteful when annotation budgets are limited: not all samples contribute equally, yet acquiring expert labels is expensive. Active learning reduces annotation cost through iterative querying, but assumes repeated access to an oracle and requires multiple rounds of model training. One-shot geometry-based methods such as facility location avoid retraining but operate on pairwise distances that ignore the local structure of the data manifold. We propose a graph-based one-shot selection method that operates entirely on frozen foundation model embeddings. Given embeddings from a pretrained encoder, we construct a k-nearest neighbor graph over all training samples and derive a two-term coverage kernel from the heat diffusion kernel, capturing both direct and two-hop neighborhood relationships. Greedy facility location on this kernel selects class-balanced subsets that maximize coverage of the data manifold. The two-term kernel matches the full spectral heat kernel in selection behavior while reducing computation to sparse matrix operations with a single hyperparameter. We evaluate on five MedMNIST datasets spanning histopathology, radiology, and microscopy, comparing against both training-dynamics and geometry-based baselines. Our method achieves the highest balanced accuracy on nine of ten dataset-ratio conditions, with the largest gains on class-imbalanced datasets where global graph construction captures cross-class structure that per-class methods miss, all without any model training during selection. Code is available at https://github.com/zahiriddin-rustamov/graph-coverage-selection.
MammoExpert: Benchmarking Chain-of-Thought Reasoning in Mammography Diagnosis
Mammography is an essential tool for breast cancer detection, with millions of examinations conducted annually. However, publicly available high-quality mammography datasets for AI development remain limited in both scale and annotation richness, particularly regarding pathological subtype coverage and structured diagnostic reasoning annotations. In this paper, we present MammoExpert, the first mammography dataset with Chain-of-Thought reasoning annotations across three diagnostic phases: (i) primal observation, (ii) factual assessment, and (iii) diagnostic synthesis. Comprising 2,379 mammography images covering 67 WHO-classified histopathology subtypes, each exam provides 42 radiographic features annotated by nine senior radiologists. We evaluate its performance on the breast lesion classification task, demonstrating superior accuracy and reasonability compared to existing classification models. Combining public dataset CBIS-DDSM with MammoExpert yields 7.1% classification accuracy improvement, while the training model to learn CoT reasoning achieves another 4% gain on the MammoExpert test set. Similar improvements are observed on INBreast and Vindr datasets, where the full approach yields accuracy gains of 6.9% and 6.7%, respectively. MammoExpert can serve as a benchmark for interpretable breast lesion diagnosis through explicit CoT reasoning.
Translating Inference-Time Control to Radiology Vision-Language Models: Activation Steering for Pneumonia Classification on Chest X-rays
Inference-time engineering can alter model behavior without fine-tuning. However, its utility for improving diagnostic performance in medical vision-language models (VLMs) remains unclear. We aim to evaluate whether Contrastive Activation Addition (CAA) can improve pneumonia classification in chest radiograph VLMs without updating model weights. Three frozen chest radiograph VLMs (MedGemma-4B-IT, NV-Reason-CXR-3B, and CheXOne-3B) were evaluated on the public Kermany pneumonia test set. Classification was based on the logits of the tokens Yes and No under a binary prompt. Steering vectors included a 30-pair answer-bias control, a 30-pair pneumonia text contrast, and an image-conditioned contrast derived from 30 pneumonia and 30 normal development images. A deterministic 200-image development set was used for layer and scale selection (100 images) and threshold calibration (100 images). Performance was assessed using ROC-AUC, PR-AUC, F1 score, threshold analyses, reverse-vector controls, random-vector controls, and conditional bootstrap confidence intervals. Fixed-threshold F1 improvements were frequently observed but did not consistently indicate improved diagnostic performance. For MedGemma-4B-IT. NV-Reason-CXR-3B showed the strongest benefit: calibrated F1 improved from 0.7692 in the zero-shot setting to 0.8619 with pneumonia-text steering and to 0.8727 with image-conditioned steering. For CheXOne-3B, pneumonia-text steering increased calibrated F1 from 0.8528 to 0.8666, although the confidence interval crossed zero. On this public pneumonia benchmark, CAA substantially altered prediction score distributions and operating characteristics without fine-tuning. Meaningful performance gains were observed in one of three evaluated VLMs, suggesting that activation steering may serve as a lightweight approach for adapting medical VLM behavior.
Geometry-Aware Superpixel Graph Transformer with Metadata for Skin Lesion Classification
Automated skin cancer classification from dermoscopic images remains challenging due to heterogeneous lesion structure, strong intra-class variability, and subtle visual differences between benign and malignant cases. Existing CNN/ViT pipelines typically rely on global or patch-level features and often combine patient metadata via late fusion, which limits spatially grounded multimodal reasoning. We present a novel region-based graph learning framework that explicitly models lesions as graphs of spatially coherent superpixel regions represented as frozen CNN features. To capture fine-grained lesion arrangements, we encode inter-regional geometry as edge attributes and introduce a dedicated metadata context node connected to all regions, providing structured integration of demographic/clinical variables within the same relational space. Node representations are updated using our edge-aware graph transformer followed by attention-driven propagation, and a final graph-level embedding for benign-malignant classification. Experiments on four public benchmarks demonstrate that explicit region-level relational modeling and graph-native multimodal fusion yield consistent gains over the state-of-the-art. Consequently, we establish a new graph-centric perspective in which CNN features are modeled as relational nodes and improved through contextual integration, yielding more expressive and robust classifications.
Alzheimer's Disease Diagnosis using a Multimodal Approach with 3D MRI and PET
Alzheimer's disease (AD) is an irreversible neurodegenerative disorder and a leading cause of death worldwide. Early diagnosis plays an important part especially at the Mild Cognitive Impairment stage, where timely intervention can help slow its progression before it advances to AD. Neuroimaging data, like Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) scans, can help detect brain changes early by providing structural and functional brain changes related to the disease. Yet, many multimodal models still fuse MRI and PET with static concatenation and apply identical computation to all subjects, which limits robustness to patient/site heterogeneity and can waste computation. To address these limitations, we present the first study of combining 3D convolutional feature extractors with three fusion strategies - concatenation, Gated Multimodal Unit (GMU), and gated self-attention - and a sparsely gated Mixture-of-Experts (MoE) classifier that performs input-adaptive routing, activating only the most informative experts per case. Finally, we utilize Grad-CAM to visualize disease-related regions, ensuring model interpretability. Experiments are performed across three binary classification tasks (NC vs. MCI, MCI vs. AD, and NC vs. AD). Results show that GMU achieves accuracies of 80.46 % (NC vs. MCI) and 95.47 % (NC vs. AD), while gated self-attention attains 82.08 % on MCI vs. AD. Ablations show that removing the MoE consistently degrades accuracy across all tasks. These findings underscore the value of input-adaptive, multimodal modeling for AD diagnosis by leveraging the complementary nature of MRI and PET.
QG-MIL: A Gated Transformer Aggregator for Domain-Agnostic Multiple Instance Learning in Medical Imaging
Attention-based Multiple Instance Learning aggregators in medical imaging are prone to attention concentration, producing overconfident and unstable predictions. We introduce QG-MIL, a gated transformer aggregator that addresses this through four synergistic architectural components: RMSNorm-based pre-normalization, per-head QK normalization, fine-grained attention output gating, and SwiGLU-style feed-forward modules. Together, these design choices stabilize training and distribute attention more uniformly across instances without auxiliary losses, masking, or multi-stage regularization. We evaluate QG-MIL across six benchmarks spanning whole-slide pathology and cell-level hematology, covering two fundamentally different MIL scales. The best-performing QG-MIL variants outperform leading baselines on all six benchmarks, with an average improvement of +6.1 mean macro F1 points. Attention overlays and attention mass analysis confirm more distributed instance weighting. Ablation studies show that while individual components can match the full model on specific datasets, the QG-MIL design provides the most consistent cross-domain performance and tightest variance when compared to selected baselines. We release a configurable implementation to support reproducibility at: https://github.com/unica-visual-intelligence-lab/QG-MIL
OTCHA: Optimal Transport-driven Confidence-aware Latent Hub Alignment for Multi-View Medical Image Classification
Multi-view imaging, such as mammography and chest radiography, is a standard component of clinical practice. However, medical images are often unregistered and contain view-specific artifacts or irrelevant background cues that can obscure diagnostically relevant findings. Many existing methods directly fuse per-view representations, allowing such irrelevant content to contaminate the fused embedding and reducing robustness under varying view configurations. We propose OTCHA, a confidence-aware latent hub token alignment module based on optimal transport (OT) that refines patch tokens before fusion for multi-view classification. OTCHA introduces a set of learnable latent hub tokens shared across views. For each view, we compute an OT plan between patch tokens and hub tokens that jointly considers feature similarity and geometry, and augment the OT formulation with token-conditional dustbins to enable partial matching and discard irrelevant tokens. The resulting transport plan provides token-wise matching confidence, which gates hub-mediated message passing and weights a novel optimal-transport-based representation alignment loss to stabilize refinement. Experiments on three multi-view medical image datasets demonstrate consistent improvements over competing baselines across diverse anatomies and view configurations. Our code is available at https://github.com/labhai/OTCHA.
A Controlled Benchmark of Quantum-Latent GAN Augmentation for Brain MRI
Medical image classification is often constrained by limited labeled data, motivating generative augmentation; recently, quantum generative models have been proposed for this purpose, frequently reporting accuracy gains. However, such claims are typically based on single training runs, do not match the parameter budgets of the quantum and classical generators, and do not characterize the data regime in which any benefit appears. We present a controlled benchmark that isolates the contribution of a quantum generator to brain-MRI augmentation. Images are encoded into a KL-regularized latent space in which a conditional Wasserstein GAN with gradient penalty is trained using either a variational quantum generator or a classical generator of near-identical parameter count (1648 vs. 1632). Synthetic samples are decoded and used to augment a pretrained classifier across labeled data fractions from 5% to 100%, evaluated over eight random seeds with paired significance testing (with multiple-comparison correction) and with intraset diversity and latent-distribution analyses. Across all fractions, no augmentation variant significantly outperforms real-data-only training, and the quantum and classical generators are statistically indistinguishable. Any low-data benefit behaves as regularization rather than faithful data expansion:synthetic samples are off distribution and severely mode collapsed precisely where data is scarce, and the quantum generator is no more diverse thanits classical counterpart. We release the protocol as a testbed for rigorous evaluation of quantum generative augmentation in medical imaging.
Multi-Class Brain Tumor Classification Using Advanced Deep Learning Models: A Comparative Study
Despite recent advancements in deep learning, accurately classifying brain tumors from MRI images continues to pose challenges. In this research, we present a comprehensive evaluation of five different convolutional neural networks (CNN) architectures, including a customized baseline model and four pre-trained models - for use in classifying multi-class brain tumors using a clinically-sourced dataset of approximately 10,000 MRI images. We have utilized five different architectures; VGG16, VGG19, DenseNet121, and EfficientNetB0, which were all tested and trained within an identical experimental framework. Performance was measured by both overall accuracy and tumor-wise recall as a means to measure the clinically-relevant performance of each architecture. We found that EfficientNetB0 had the best overall classification accuracy at 95%, when compared to the other architectures tested; specifically VGG16 (94.37%), VGG19 (92.29%), DenseNet121 (90.91%) and the customized CNN (78.00%). An especially important finding of our research was the considerable improvement in detecting meningiomas; specifically, while simple CNNs could detect meningiomas with a recall rate of approximately 20%, EfficientNetB0 was able to detect meningiomas with a recall rate of 89%. Meningiomas are often difficult to detect because they can appear very subtly on MRI images. Additionally, an interesting finding was that the deeper VGG19 performed worse than the shallower VGG16. This indicates that in many cases the architectural efficiency of a CNN model may be more important than its depth when working with medical images. Overall, EfficientNetB0 appears to provide the optimal trade-off between classification accuracy, number of parameters used in the model and clinically meaningful performance.
When LLMs Analyze Scars: From Images to Clinically-Meaningful Features
Medical image classification faces a fundamental dilemma: while deep learning models achieve remarkable performance at scale, real-world clinical scenarios often suffer from severe data scarcity due to annotation costs, privacy constraints, and disease rarity. This challenge is particularly pronounced in pathological scar classification, where differentiating keloids from hypertrophic scars requires subtle expert knowledge and labeled images are extremely limited. We propose a novel paradigm that repositions large language models (LLMs) as knowledge-driven feature engineers rather than end-to-end classifiers. We call this framework ScaFE (Scar Feature Engineering). Our key insight is that LLMs encode rich medical knowledge that can be externalized as executable feature extraction code, enabling the transformation of high-dimensional images into low-dimensional, clinically interpretable representations. Specifically, we prompt an LLM with established scar assessment criteria to generate deterministic Python code that extracts features aligned with clinical scoring systems such as the Vancouver Scar Scale. Our approach offers three key advantages: (1) data efficiency, achieving robust performance with limited training samples by decoupling knowledge acquisition from statistical learning; (2) privacy preservation, as raw images are processed locally without exposure to external LLMs; and (3) interpretability, through explicit features grounded in clinical reasoning. Extensive experiments on scar classification demonstrate that our method consistently outperforms end-to-end deep learning baselines or using LLMs as black-box classifiers under limited data conditions, establishing a promising direction for integrating LLMs into data-efficient and clinically transparent medical AI systems.
A Multi-Center Benchmark for Abdominal Disease Diagnosis and Report Generation from Non-Contrast CT
Multiphasic contrast-enhanced CT (CECT) is widely used for abdominal lesion characterization, yet it carries inherent risks of contrast-induced nephropathy, escalates acquisition burden, and heavily contributes to radiologist workload. To address these challenges, we introduce a novel multi-center benchmark for multi-organ abdominal disease diagnosis and automated radiology report generation, which learns to synthesize contrast-enhanced findings from single-phase non-contrast CT (NCCT). To support this, we curated a large-scale dataset of paired NCCT-CECT studies and their corresponding contrast-enhanced radiology reports from two centers, partitioned into internal sets and an external validation cohort. Under a unified evaluation protocol, we benchmarked five contemporary deep learning architectures encompassing chest-specific, abdomen-specific, and general-purpose multimodal domains. Extensive experiments demonstrate that NCCT retains diagnostic signals, achieving an average multi-organ AUC of 69.1% on the internal cohort and 63.1% on the external cohort, respectively. By releasing this dataset and standardized benchmark publicly, this study aims to catalyze future research into safer, resource-efficient, and globally accessible contrast-free abdominal imaging workflows. Code is available at: https://github.com/xmed-lab/TriALS-Report.
LLM-Based Visual Explanation Evaluation Framework for Assessing the Explainability of Facial Skin Disease Classification Models
This study proposes a domain-specific LLM-based Visual Explanation Evaluation Framework for assessing Grad-CAM explanations in facial skin disease diagnosis models. While previous studies have primarily focused on improving classification performance through data augmentation techniques, relatively few studies have systematically examined whether model explanations are grounded in clinically relevant lesion regions. In this study, geometric augmentation, color-based augmentation, and mixed augmentation strategies were applied to facial skin disease classification models based on EfficientNet-B0, MobileNetV3, and ResNet18. Grad-CAM was employed to generate visual explanations representing the models' decision-making processes. Furthermore, an LLM-as-a-Judge evaluation framework was designed using GPT-5.5, Gemini 3.5 Flash, and Claude Sonnet 4.6 to assess Grad-CAM explanations from the perspectives of lesion localization and explanation trustworthiness. To improve evaluation consistency and clinical grounding, a progressive prompt engineering strategy was introduced, incorporating evaluation rubrics, clinical knowledge, penalty rules, and structured output formats.
3D Classification of Paramagnetic Rim Lesions in Multiple Sclerosis via Asymmetric QSM-FLAIR Modeling
Paramagnetic rim lesions (Rim) identified on susceptibility-sensitive MRI have recently emerged as a specific biomarker of chronic active inflammation in Multiple Sclerosis (MS) and are associated with long-term disability progression. However, susceptibility imaging and expert interpretation remain limited to specialized centers, visual assessment is time-consuming and variable, and the low prevalence of Rim lesions poses severe class imbalance challenges for automated analysis. We propose a 3D multimodal deep learning framework for lesion-level Rim/Rim classification from Quantitative Susceptibility Mapping (QSM) and FLAIR MRI. The architecture explicitly models modality asymmetry by treating QSM as the primary susceptibility-driven signal and conditioning it with FLAIR-derived structural context. To improve robustness under limited data, we employ self-supervised multimodal pretraining followed by supervised fine-tuning with contrastive regularization. The method was evaluated on a clinically acquired cohort of 88 people with MS with expert lesion annotations as reference standard. Results highlight improved performance compared to prior architectures, supporting the effectiveness of asymmetric multimodal modeling for automated chronic active lesion identification.
Structure-aware Knowledge-guided Heterogeneous Mamba for Zygomaticomaxillary Suture Assessment
The Zygomaticomaxillary Suture is a key circummaxillary structure that connects the zygomatic bone and the maxilla, which serves as a primary site of resistance during maxillary advancement, and its maturation status directly influences the timing and efficacy of orthopedic interventions. However, accurate staging of ZMS maturation remains challenging due to subtle high-frequency transitions in suture lines and the global semantic ambiguity between adjacent stages. To address this, we present the first public ZMS dataset, comprising 3,790 ZMS images covering the entire age range from 4 to 24 years. Based on this dataset, we propose SKMamba, a Structure-aware and Knowledge-guided Mamba-based multi-modal framework for automated ZMS maturation assessment. SKMamba adopts a decoupled dual-path architecture that mimics the hierarchical diagnostic process used by experienced orthodontists. We first introduce an Implicit Edge Extractor (IEE), which leverages structural pre-training to reduce trabecular noise and accentuate sutural boundaries. Complementarily, a Cross-Modal Semantic Alignment (CSA) module is designed to incorporate anatomical descriptions from a large language model (LLM). This module helps align local morphological cues with global semantic descriptions while ensuring that objective morphological evidence remains the primary basis for decisions. Extensive experiments on our ZMS dataset demonstrate that SKMamba achieves state-of-the-art performance compared to existing methods. Code is available at https://github.com/galaxygxq1116/SKMamba.
Input-Dependent Fisher Information for Local Sensitivity Analysis of Medical Image Classifiers
Deep neural networks have achieved strong performance in medical image classification, but often work like black-box. Commonly used post-hoc interpretation methods often provide heuristic visualizations whose relationship to the classifier's predictive distribution is indirect. This work introduces a local sensitivity analysis framework based on the input-dependent Fisher Information Matrix (iFIM) of a trained classifier. The iFIM characterizes how the classifier's predictive distribution changes under infinitesimal perturbations of the input image. By using a Gram-matrix formulation, the nonzero eigenspectrum of the iFIM can be recovered without explicitly forming the full image-dimensional Fisher matrix. The leading iFIM eigenspace is then used to project an input image into a high local-sensitivity component and its orthogonal component. These components provide a model-intrinsic description of local predictive sensitivity, rather than a conventional pixel-wise attribution heatmap or a causal segmentation of task-relevant anatomy. The framework is evaluated on controlled and clinical medical image classification tasks using multiple classifier architectures. Perturbation-based experiments show that high-sensitivity iFIM components are more strongly coupled to changes in predictive confidence and classification performance than lower-sensitivity complementary components. The results support the iFIM framework as a principled tool for analyzing local decision sensitivity and for complementing existing attribution-based interpretability methods in medical imaging.
Trusting Right Predictions for Wrong Reasons: A LIME Based Analysis of Deep Learning Interpretability in Lung Cancer Diagnosis
Lung cancer is the leading cause of cancer-related mortality, with approximately 2.5 million new cases and 1.8 million deaths annually, making reliable diagnosis a clinical priority. Although deep learning models have achieved strong performance in lung cancer classification, evaluation has largely focused on predictive accuracy, leaving their decision-making processes insufficiently examined. This study compares three architecturally distinct models: a Convolutional Neural Network (CNN), a pretrained ResNet50, and a Vision Transformer (ViT), trained on the IQ-OTH/NCCD lung cancer CT dataset. Local Interpretable Model-Agnostic Explanations (LIME) were applied to investigate model reasoning. In addition to standard performance metrics, a dual-correlation framework was introduced to measure both prediction agreement and explanation agreement across model pairs. All three models achieved strong classification performance, with ResNet50 attaining 98.61% accuracy, CNN 97.91%, and ViT 93.75%, while all achieved ROC-AUC scores of 0.99. Prediction correlations exceeded 0.99 across all model pairs, indicating highly consistent outputs. However, LIME explanation correlations remained below 0.26, revealing substantial differences in the image regions used to reach those predictions. Analysis of misclassified samples further identified a consistent spatial pattern: incorrect predictions were associated with attention outside the lung parenchyma, whereas correct predictions focused primarily within lung regions. These findings demonstrate that prediction agreement is a poor proxy for reasoning consistency, and that interpretability evaluation must be treated as an independent validation criterion alongside predictive performance in clinical AI systems.
NeRD: Neuro-Symbolic Rule Distillation for Efficient Ontology-Grounded Chain-of-Thought in Medical Image Diagnosis
Interpretability is essential for trustworthy medical image diagnosis. However, existing concept-driven interpretable methods have key limitations: Concept Bottleneck Models (CBMs) require scoring all predefined concepts at inference time and for manual intervention, imposing a substantial burden on clinicians, while rationale-based generative approaches often select concepts by class discriminability, which can drift from diagnostic ontologies. To address these issues, we propose Neuro-Symbolic Rule Distillation (NeRD), a framework that produces efficient, ontology-grounded reasoning chains that are sufficient yet non-redundant, without manually crafting diagnostic rules. Experiments on two skin datasets demonstrate strong diagnostic performance and interpretability, and blinded expert evaluation confirms the clinical plausibility of NeRD rationales. Our method further enables a first expert-in-the-loop study for Multimodal Chain-of-Thought-based diagnosis, achieving efficient and effective concept-level intervention.
Trusted Multi-View Deep Learning Classification of Fetal Congenital Heart Disease with Feature-level and Decision-level Fusion
Congenital heart disease (CHD) refers to the abnormal anatomical structure caused by the abnormal development of the heart and great vessels during embryonic development. Traditional diagnostics often fail to achieve high accuracy and efficiency, especially given the complexity of cardiac anatomy. This study presents a specialized multi-view deep learning framework for CHD binary classification using echocardiographic images. A large-scale CHD dataset, including five views, was used to train the model, enabling it to integrate multi-angle image data. The framework utilizes advanced feature extraction and attention mechanisms to improve diagnostic precision and reliability. An uncertainty-based decision-making component is also integrated to handle low-quality images, enhancing diagnostic outcomes. Experimental results show that this method achieves top-tier performance on our dataset and provides a robust tool for early CHD detection, underscoring its potential for clinical use. The dataset and source code will be released upon paper acceptance.
Towards Global AI-Driven Cervical Cancer Screening
The global elimination of cervical cancer is a key public health goal set by the World Health Organization (WHO), with screening programs reducing mortality by up to 80%. However, access to experts and biopsy services is limited in low- to middle-income countries (LMICs). Deep learning (DL)-based algorithms offer promising support for screening, but most existing approaches have been developed and validated on private datasets from single countries. We present the first DL-based approach to cervical cancer screening validated on data from multiple countries. Technically, we phrase the problem of detecting and classifying lesions in colposcopy images as a multi-task learning problem, in which we simultaneously perform image-level classification and lesion segmentation. Our model was trained on a private data set of acid stain colposcopy images with manually generated lesion segmentation masks and corresponding histopathological results, employing extensive data augmentation to address image variability. In an in-distribution validation with pathology results serving as ground truth, our algorithm outperformed medical experts (Balanced Accuracy: 0.68 vs 0.64) in CIN1- (Cervical intraepithelial neoplasia grade 1 or lower) versus CIN2+ (grade 2 or higher) classification. External validation on four colposcopy data sets from four countries featuring radical differences in prevalence and patient characteristics yielded superior performance of our method compared to baseline methods. Performance variability across countries was high with AUC values ranging from 0.54 - 0.80. Overall, algorithm performance varied with age, transformation zone (cervical area most prone to lesion development), presence of comorbidities and pathognomonic signs, with comorbidities having by far the largest negative effect. Future work should focus on improving model robustness and generalizability.
Polyp-D2ATL: Deep Domain-Adaptive Transfer Learning for Colorectal Polyp Classification under Label Distribution Shift
Early and highly accurate prediction of colorectal polyps, as an important sign of one of the most dangerous types of cancer, will result in saving more lives. Despite the advancements in colorectal polyp classification, many challenges remain in obtaining an automated polyp prediction system that is able to diagnose the difficult-to-predict polyps accompanied by different features in real scenarios, where the model can handle imbalanced data, label distribution shift, and cross-modality generalization successfully. In this study, we propose Polyp-D2ATL, a novel framework accompanied by a specific training strategy, which mitigates these limitations and effectively predicts the different classes of polyps belonging to the NICE classification. Our extensive experiments on the PICCOLO validation and test sets demonstrate that the proposed Polyp-D2ATL significantly outperforms existing state-of-the-art models across various reliable metrics, achieving an accuracy of 82.38%, a Macro-F1 of 77.49%, and a specificity of 87.47% on the validation set, alongside consistent improvements on the held-out test set which demonstrates the generalization capacity and clinical applicability of the proposed approach.
Hybrid Classical-Quantum (HCQ) Alzheimer's Classification via Supervised -VAE and Quantum Kernels
This paper presents a two-stage Hybrid Classical-Quantum (HCQ) pipeline for binary Alzheimer's disease (AD) classification from 3D T1-weighted structural MRI volumes, where the classical and quantum components are designed to complement each other rather than operate independently. A supervised 3D -variational autoencoder (VAE) is trained end-to-end under voxel-wise reconstruction, KL-divergence, and focal classification losses that compress each 3D MRI volume (resized from 152 x 184 x 152 to 96 x 96 x 96) into a 64-dimensional latent code. Partial Least Squares (PLS) regression selects the six components in the latent code that best separate Alzheimer's Disease (AD) from cognitively normal (CN) subjects and rescales them into rotation angles, which are encoded onto a six-qubit register using the ZZ quantum feature map to give us the respective quantum states. The input to a precomputed-kernel Support Vector Machine (SVM) is an N x N Gram matrix (N = 308), created by calculating the overlap between every pair of quantum states. The novelty of this work lies in the fact that the quantum kernel operates directly on disease-aware features that are learned end-to-end by a supervised autoencoder, rather than on pre-extracted inputs. On 308 ADNI-1 subjects, consisting of 137 AD and 171 CN subjects, the baseline achieved 67.2% accuracy and 0.759 AUC, while the stability-enhanced variant reached 72.1% accuracy and 0.799 AUC with cross-fold variance halved. 3D Grad-CAM further helped validate our model's focus on brain regions linked to Alzheimer's. The HCQ pipeline could serve as a general-purpose framework for diagnostic classification across biomedical imaging domains that present similar challenges for classical approaches.