3D Medical Image Segmentation
Momentum
18 papers in the last four weeks, up 260% on the four weeks before. 0.2% of all new papers.
Latest papers 125
Unsupervised segmentation of pulmonary pathologies in CT remains an open challenge due to the absence of annotated multi pathology cohorts and the failure of existing diffusion-based methods to exploit the quantitative Hounsfield Unit (HU) signal that physically distinguishes tissue classes. To address this, we propose DiffSegLung,a framework that introduces Diffusion Radiomic Distillation, in which handcrafted radiomic descriptors serve as a physics grounded teacher to shape the bottleneck of a 3D diffusion U-Net via a contrastive objective, transferring pathology discriminative structure into the learned representation without any annotations. At inference, the teacher is discarded and multitimestep bottleneck features are clustered by a Gaussian Mixture Model with HU-guided label assignment, followed by Sobel Diffusion Fusion for boundary refinement. Evaluated on 190 expert annotated axial slices drawn from four heterogeneous CT cohorts, Diff-SegLung improves segmentation across all four pathology classes over unsupervised baselines and improves generation fidelity over prior CT diffusion models.
Cross-Source Supervision for Bone Infection Segmentation in Dual-Modality PET-CT
Early and accurate diagnosis and lesion localization of bone infections are crucial for clinical treatment. PET-CT integrates anatomical information from CT with metabolic information from PET, making it an important imaging modality for diagnosing bone infections. However, accurate lesion segmentation remains challenging due to indistinct lesion boundaries and inconsistencies in annotations generated by different experts or automated systems. In this work, we investigate multimodal segmentation of bone infections under annotation discrepancy. We develop a bimodal end-to-end segmentation framework that integrates PET metabolic signals and CT bone-window anatomy through an early-fusion multimodal representation.To mitigate performance inflation caused by inter-slice correlation in small datasets, this study discards traditional two-dimensional evaluation methods and implements a rigorous patient-level 3D volumetric evaluation and cross-validation. Furthermore, instead of forcing a singular consensus, we propose a decoupled dual-source learning framework where parallel models are trained on independent expert annotations driven by high-sensitivity and high-specificity clinical intents. Experimental results objectively report performance variations at the patient level (Mean + SD and Mean - SD), demonstrating the effectiveness of multimodal PET-CT fusion. The cross-evaluation matrix quantitatively reveals how models successfully internalize distinct expert diagnostic philosophies, providing a robust, diversity-preserving paradigm for clinical AI deployment in bone infection segmentation.
DINO-MVR: Multi-View Readout of Frozen DINOv3 for Annotation-Efficient Medical Segmentation
Adapting foundation models to medical segmentation typically requires either backbone fine-tuning or high-capacity task-specific decoders, both of which are difficult to fit reliably when annotations are scarce. We show that frozen DINOv3 features already contain useful structural and boundary cues for medical segmentation, and that the main bottleneck lies in how these features are read out. We propose DINO-MVR, a Multi-View Readout framework for annotation-efficient medical segmentation. DINO-MVR trains only lightweight MLP probes on features from the final three transformer blocks of a frozen DINOv3 backbone, without updating the backbone itself. At inference, each input is interpreted through complementary resolutions and test-time augmentations, whose probability maps are combined by entropy-weighted fusion and refined with simple spatial regularization. For volumetric inputs, Gaussian z-axis smoothing further improves inter-slice consistency. Under fixed evaluation protocols on endoscopy, dermoscopy, and MRI benchmarks, DINO-MVR achieves strong readout-only performance, including 0.895 Dice on Kvasir-SEG, 0.897 Dice on ISIC 2018, and 0.908 Dice on BraTS FLAIR whole-tumor segmentation. With only five annotated BraTS patients, it recovers 98.4% of the performance obtained by the 40-patient BraTS reference run. These results suggest that frozen self-supervised vision backbones can support accurate medical segmentation when paired with an effective multi-view readout.
DALight-3D: A Lightweight 3D U-Net for Brain Tumor Segmentation from Multi-Modal MRI
Automatic brain tumor segmentation from multi-modal MRI remains challenging because volumetric models often incur substantial computational cost. This paper presents DALight-3D, a compact 3D U-Net variant that combines depthwise separable 3D convolutions, identifier-conditioned normalization, cross-slice attention, and adaptive skip fusion. The method is evaluated on the Medical Segmentation Decathlon Task01 BrainTumour benchmark under matched optimization settings against standard 3D U-Net, Attention U-Net, Residual 3D U-Net, and V-Net baselines. In the reported 50-epoch comparison, DALight-3D achieves a mean Dice of 0.727 with 2.22M parameters, compared with 0.710 Dice and 3.20M parameters for Residual 3D U-Net. Component-wise ablations show consistent performance degradation when SepConv, identifier-conditioned normalization, CSA, or SSFB is removed. These results indicate that DALight-3D offers a favorable accuracy-efficiency trade-off within the present benchmark setting.
Topology-Constrained Quantized nnUNet for Efficient and Anatomically Accurate 3D Tooth Segmentation
We propose a topology-constrained quantized nnUNet framework for efficient and anatomically accurate 3D tooth segmentation, addressing the challenges of spatial distortion introduced by quantization in deep learning models. The proposed method integrates a novel tooth-specific topological loss into quantization-aware training, preserving critical anatomical structures such as tooth count, adjacency relationships, and cavity integrity while maintaining computational efficiency. The system employs an 8-bit quantized nnUNet backbone, where weights and activations are dynamically calibrated to minimize precision loss during inference. Furthermore, the topological loss combines connected-component analysis, adjacency consistency, and hole detection penalties, ensuring anatomical fidelity without modifying the underlying network architecture. The joint optimization objective harmonizes cross-entropy loss, quantization regularization, and topological constraints, enabling end-to-end training with gradient approximations for persistent homology terms. Experiments demonstrate that our approach significantly reduces topological errors compared to conventional quantized models, achieving clinically plausible segmentations on dental CBCT scans. The method retains the hardware efficiency of integer-only inference, making it suitable for deployment in resource-constrained clinical environments. This work bridges the gap between computational efficiency and anatomical precision in medical image segmentation, offering a practical solution for real-world dental applications.
Enhanced 3D Brain Tumor Segmentation Using Assorted Precision Training
A brain tumor is a medical disorder faced by individuals of all demographics. Medically, it is described as the spread of non-essential cells close to or throughout the brain. Symptoms of this ailment include headaches, seizures, and sensory changes. This research explores two main categories of brain tumors: benign and malignant. Benign spreads steadily, and malignant expresses growth, making it dangerous. Early identification of brain tumors is a crucial factor for the survival of patients. This research provides a state-of-the-art approach to the early identification of tumors within the brain. We implemented the SegResNet architecture, a widely adopted architecture for three-dimensional segmentation, and trained it using the automatic multi-precision method. We incorporated the dice loss function and dice metric for evaluating the model. We got a dice score of 0.84. For the tumor core, we got a dice score of 0.84; for the whole tumor, 0.90; and for the enhanced tumor, we got a score of 0.79.
RD-ViT: Recurrent-Depth Vision Transformer for Semantic Segmentation with Reduced Data Dependence Extending the Recurrent-Depth Transformer Architecture to Dense Prediction
Vision Transformers (ViTs) achieve state-of-the-art segmentation accuracy but require large training datasets because each layer has unique parameters that must be learned independently. We present RD-ViT, a Recurrent-Depth Vision Transformer that adapts the Recurrent-Depth Transformer (RDT) architecture to dense prediction tasks, supporting both 2D and 3D inputs. RD-ViT replaces the deep stack of unique transformer blocks with a single shared block looped T times, augmented with LTI-stable state injection for guaranteed convergence, Adaptive Computation Time (ACT) for spatial compute allocation, depth-wise LoRA adaptation, and optional Mixture-of-Experts (MoE) feed-forward networks for category-specific specialization. We evaluate on the ACDC cardiac MRI segmentation benchmark in both 2D slice-level and 3D volumetric settings with exclusively real experiments executed in Google Colab. In 2D, RD-ViT outperforms standard ViT at 10% training data (Dice 0.774 vs 0.762) and at full data (0.882 vs 0.872). In 3D, RD-ViT with MoE achieves Dice 0.812 with 3.0M parameters, reaching 99.4% of standard ViT performance (0.817) at 53% of the parameter count. MoE expert utilization analysis reveals that different experts spontaneously specialize for different cardiac structures (RV, MYO, LV) without explicit routing supervision. ACT halting maps show higher compute allocation at cardiac boundaries, and the mean ponder time decreases from 2.6 to 1.4 iterations during training, demonstrating learned computational efficiency. Depth extrapolation enables inference with more loops than training without degradation. All code, notebooks, and results are publicly released.
Augmented Equivariant Mesh Networks for Anatomical Segmentation
Anatomical mesh segmentation requires models that operate directly on irregular surface geometry while remaining robust to changes in coordinate pose across meshes of varying resolution. Existing task-specific mesh and point-cloud methods are not equivariant, and can degrade sharply under test-time perturbation, for example dropping by 28-30 IoU points on 3D-IOSSeg at rotation even with matched training augmentation. We present EAMS, an Equivariant Anatomical Mesh Segmentor built on Equivariant Mesh Neural Networks (EMNN), and evaluate it in four dataset settings across three clinical application areas, spanning edge-, vertex-, and face-level supervision. We combine intrinsic mesh descriptors with anatomy-aware priors, including PCA-derived frames for dental arches and liver surfaces, and augment message passing to provide lightweight global context. Across intracranial aneurysm and intraoral segmentation, EAMS variants are competitive with specialized baselines on unperturbed inputs while remaining stable under geometric perturbations, and on liver surfaces they expose a favorable trade-off between canonical-pose accuracy and rotation robustness. These results show that a lightweight (M parameters) equivariant framework can deliver robust anatomical mesh segmentation across diverse label types.
One Sequence to Segment Them All: Efficient Data Augmentation for CT and MRI Cross-Domain 3D Spine Segmentation
Deep learning-based medical image segmentation is increasingly used to support clinical diagnosis and develop new treatment strategies. However, model performance remains limited by the scarcity of high-quality annotated data and insufficient generalization across imaging protocols. This limitation is particularly evident in MRI and CT, where models are typically trained on a single acquisition sequence and exhibit reduced robustness when applied to unseen sequences or contrasts. Although data augmentation is widely used to improve general robustness on medical images, its impact on cross-modality generalization has not been quantitatively explored. In this work, we study a targeted set of data augmentation techniques designed to improve cross-modality transfer. We train three spine segmentation models, each on a single-modality/sequence dataset, and evaluate them across seven out-of-distribution datasets (spanning CT and MRI), reflecting a realistic single-sequence training and multi-sequence/contrast/modality deployment scenario. Our results demonstrate substantial performance gains on unseen domains (average Dice gain of 155 %) while preserving in-domain accuracy (average Dice decrease of 0.008 %), including effective transfer between CT and MRI. To mitigate the computational cost typically associated with strong data augmentation, we implement GPU-optimized augmentations that maintain, and even improve, training efficiency by approximately 10 %. We release our approach as an open-source toolbox, enabling seamless integration into commonly used frameworks such as nnUNet and MONAI. These augmentations significantly enhance robustness to heterogeneous clinical imaging scenarios without compromising training speed.
SIAM: Head and Brain MRI Segmentation from Few High-Quality Templates via Synthetic Training
Synthetic training has recently advanced brain MRI segmentation by enabling contrast-agnostic models trained entirely on generated data. However, most existing approaches rely on hundreds of automatically labeled templates, introducing systematic biases and limiting their flexibility to incorporate new anatomical structures. We present the Segment It All Model (SIAM), a 3D whole-head segmentation framework for 16 anatomical structures, trained using only six high-quality, manually annotated templates. SIAM extends domain randomization to both intensity and shape domains: synthetic image generation ensures contrast variability, while high-resolution spatial transformations model anatomical differences in cortical thickness and deep nuclei morphology. Unlike prior synthetic models, SIAM simultaneously segments brain as well as extra-cerebral tissues, including cerebrospinal fluid, vessels, dura mater, skull, and skin, enabling fully automated, preprocessing-free analysis. Evaluation across eight heterogeneous datasets (N=301), that include multiple contrasts (T1-weighted, T2-weighted, CT) and span a wide range of ages, demonstrates that SIAM matches or outperforms state-of-the-art methods for brain structures, in addition to extending automated segmentation to non-brain structures. The model also exhibits superior consistency across contrasts and repeated acquisitions, together with improved sensitivity to subtle gray matter atrophy. We openly release the model and the label templates at https://github.com/romainVala/SIAM.
Advanced Tumor Segmentation in PET/CT Imaging: A Training Strategy Study with nnU-Net for AutoPET III
Tumor segmentation in whole-body PET/CT imaging is crucial for precise disease evaluation and treatment planning. However, it remains challenging due to variability in lesion size, contrast, and anatomical distribution. Relying on manual segmentation makes the process time-consuming and prone to intra- and inter-observer variability. This work presents a whole-body tumor segmentation method developed for the AutoPET III challenge, where the goal is to build models that generalize across tracers and multi-center data. We employ the nnU-Net framework with a ResNet-based encoder as our baseline and systematically investigate the impact of training strategies, including intensity normalization, batch dice optimization, and data augmentation using CraveMix. Our experiments show that these strategies significantly influence model performance, particularly in reducing false positives and improving robustness to lesion variability. The best-performing configuration achieves a Dice score of up to 0.80 on the preliminary test phase, and our method ranked third in the AutoPET III challenge. The code is publicly available here.
M\textsuperscript{4}Fuse: Lightweight State-Space MoE with a Cross-Scale Gating Bridge for Brain Tumor Segmentation
Encoder-decoder imbalance and the reliance on large input volumes make many 3D brain tumor segmentation models both compute-heavy and brittle. We present M\textsuperscript{4}Fuse, a lightweight network that prioritizes discriminative brain tumor cues over exhaustive appearance reconstruction. Our method balances encoder and decoder capacity and replaces depth expansion with a synergistic design: it propagates long-range context with linear complexity via a grouped state space mixer, denoises and aligns skip features using a cross-scale dual-stage gating bridge, and absorbs cross-site acquisition shifts with a sample-level mixture-of-experts. On the BraTS2019 and BraTS2021 benchmarks, M\textsuperscript{4}Fuse outperforms other lightweight excellent methods in both parameter count and performance. Even at a challenging input resolution of (half that of existing excellent models), M\textsuperscript{4}Fuse reduces parameters by 62.63% and improves average performance by 0.09%. Ablations of key components validate the method's exceptional parameter-to-accuracy efficiency and robustness across diverse data centers.
Exploring Entropy-based Active Learning for Fair Brain Segmentation
Active learning (AL) has emerged as a crucial strategy for reducing the prohibitive costs associated with medical image segmentation. However, standard uncertainty-based AL methods typically focus on maximizing performance metrics, ignoring performance disparities or fairness across groups with sensitive attributes. While fair active learning has been explored in classification tasks, its intersection with medical image segmentation remains unaddressed. In this work, we introduced a fairness-aware active learning framework with a Weighted Entropy selection strategy that modulates uncertainty based on current group-specific performance estimates on the labeled set. To decouple true epistemic uncertainty from anatomical volume variances, we further utilized a masked, scaled entropy restricted to the region of interest. The framework was evaluated on synthetic T1-weighted brain MRIs with controlled left caudate bias in both strong and weak bias settings. A 3D U-Net was trained to segment the left caudate under several AL strategies, starting from both demographically balanced and strongly imbalanced initial labeled sets. Experiments demonstrated that our method markedly reduces performance disparities between groups compared to random sampling and standard uncertainty sampling. By prioritizing poorly segmented subgroups during the AL cycles, our method consistently achieved the highest equity-scaled performance and reduced the disparity metric by 75% (strong bias) and 86% (weak bias) relative to standard entropy at the final budget. Overall, this work is among the first studies on fair AL for medical image segmentation, offering an efficient strategy to train more equitable models in resource-constrained environments.
Vesselpose: Vessel Graph Reconstruction from Learned Voxel-wise Direction Vectors in 3D Vascular Images
Blood vessel segmentation and -tracing are essential tasks in many medical imaging applications. Although numerous methods exist, the prevailing segment-then-fix paradigm is fundamentally limited regarding its suitability for modeling the task of complete and topologically accurate vascular network reconstruction. Here, we propose an approach to extract topologically more accurate vascular graphs from 3D image data, building upon highly successful ideas from the related biomedical tasks of cell segmentation and -tracking. Our approach first predicts voxel-wise vessel direction vectors joint with standard vessel segmentation masks. Second, to extract the vascular graph from these predictions, we introduce a direction-vector-guided extension of the TEASAR algorithm. Our approach achieves state-of-the-art performance on three benchmark datasets, spanning both synthetic and real imagery. We further demonstrate the applicability of our approach to challenging 3D micro-CT scans of rat heart vasculature. Finally, we propose meaningful and interpretable measures of topological error, namely false splits and false merges for graphs. Overall, our approach substantially improves the topological accuracy of reconstructed vascular graphs, being able to separate closely apposed vessel segments and handle multiple vascular trees within a single volume.
AG-TAL: Anatomically-Guided Topology-Aware Loss for Multiclass Segmentation of the Circle of Willis Using Large-Scale Multi-Center Datasets
Accurate multiclass segmentation of the Circle of Willis (CoW) is essential for neurovascular disease management but remains challenging due to complex vascular topology and variable morphology. Existing deep learning methods often suffer from vascular discontinuities and inter-class misclassification, while current topological loss functions incur prohibitive computational costs in 3D multiclass settings. To address these limitations, we propose an Anatomically-Guided Topology-Aware Loss (AG-TAL) and introduce a large-scale, multi-center CoW dataset with unified annotations to facilitate robust model training. AG-TAL specifically integrates a radius-aware Dice loss to address class imbalance in small vessels, a breakage-aware clDice loss that utilizes group convolutions to efficiently preserve local connectivity, and an adjacency-aware co-occurrence loss that leverages anatomical priors to enforce distinct boundaries between neighboring arteries. Evaluated using 5-fold cross-validation, AG-TAL achieved an average Dice score of 80.85% for all CoW arteries, with small arteries notably higher by 1.05-3.09% compared to state-of-the-art methods. Across six independent datasets, the performance of AG-TAL achieved Dice scores ranging from 74.46% to 81.17% for all CoW arteries, with improvements of 2.20% to 9.98% for small arteries compared to other methods. This study demonstrates the superiority of AG-TAL in identifying multiclass CoW arteries and its ability to generalize well to multiple independent datasets. Furthermore, reliability analyses and clinical applications in an Alzheimer's disease cohort validate the AG-TAL's robustness and its potential for discovering imaging-based morphological biomarkers.
Multi-Stage Bi-Atrial Segmentation Framework from 3D Late Gadolinium-Enhanced MRI using V-Net Family Models
We report our multi-stage framework designed for the problem of multi-class bi-atrial segmentation from 3D late gadolinium-enhanced (LGE) MRI of the human heart. The pipeline consists of a preprocessing step using multidimensional contrast limited adaptive histogram equalization (MCLAHE); coarse region segmentation from MCLAHE-enhanced and down-sampled MRI using a V-Net family model; and fine segmentation from the coarse region using another V-Net model. Asymmetric loss is adopted to optimize the model weights.
TopoMamba: Topology-Aware Scanning and Fusion for Segmenting Heterogeneous Medical Visual Media
Visual state-space models (SSMs) have shown strong potential for medical image segmentation, yet their effectiveness is often limited by two practical issues: axis-biased scan ordering weakens the modeling of oblique and curved structures, and naive multi-branch fusion tends to amplify redundant responses. We present TopoMamba, a topology-aware scan-and-fuse framework for segmenting heterogeneous medical visual media. The method combines a diagonal/anti-diagonal TopoA-Scan branch with the standard Cross-Scan branch to provide complementary structural priors, and introduces ScanCache, a device-aware caching mechanism that amortizes explicit scan-index construction across recurring resolutions. To fuse heterogeneous scan features efficiently, we further propose a lightweight HSIC Gate that regulates branch interaction using a dependence-aware scalar gating rule. We also instantiate a volumetric TopoMamba-3D for practical 3D clinical segmentation. Experiments on Synapse CT, ISIC 2017 dermoscopy, and CVC-ClinicDB endoscopy show that TopoMamba consistently improves segmentation quality over strong CNN, Transformer, and SSM baselines, with particularly clear gains on thin or curved targets such as the pancreas and gallbladder, while maintaining favorable deployment efficiency under dynamic input resolutions. These results suggest that topology-aware scan ordering and lightweight dependence-aware fusion form an effective and practical design for medical multimedia segmentation. The code will be made publicly available.
ESICA: A Scalable Framework for Text-Guided 3D Medical Image Segmentation
Text guided 3D medical image segmentation offers a flexible alternative to class based and spatial prompt based models by allowing users to specify regions of interest directly in natural language. This paradigm avoids reliance on predefined label sets, reduces ambiguous outputs, and aligns more naturally with clinical workflows. However, existing text guided frameworks are often computationally expensive, exhibit weak text volume feature alignment, and fail to capture fine anatomical details. We propose ESICA, a lightweight and scalable framework that addresses these challenges through three innovations: (1) a similarity matrix based mask prediction formulation that enhances semantic alignment, (2) an efficient decomposed decoder with adapter modules for accurate volumetric decoding, and (3) a two pass refinement strategy that sharpens boundaries and resolves uncertain regions. To improve training stability and generalization, ESICA adopts a two stage scheme consisting of positive only pretraining followed by balanced fine tuning. On the CVPR BiomedSegFM benchmark spanning five imaging modalities (CT, MRI, PET, ultrasound, and microscopy), ESICA achieves state of the art segmentation accuracy, while the compact ESICA4 Lite variant attains similar segmentation performance with substantially fewer parameters, yielding a superior efficiency accuracy trade off. Our framework advances text guided segmentation toward efficient, scalable, and clinically deployable systems. Code will be made publicly available at https://github.com/mirthAI/ESICA.
Instance Awareness of Multi-class Semantic Segmentation Loss Functions
Instance-sensitive losses for semantic segmentation such as blob loss and CC loss were designed to address instance imbalance, ensuring small lesions generate the same gradient as large ones, but operate only on single-class segmentation. In multi-class settings, class imbalance poses an additional problem: rare classes with few instances receive a disproportionately small share of the training signal. We show that extending instance-sensitive losses to multi-class segmentation via a one-vs-rest class decomposition repurposes them to also address class imbalance, as uniform averaging over classes ensures each class contributes equally regardless of frequency. We further show that inverse-size weighting, which destabilizes training when applied globally due to weight imbalances across rare and common classes, becomes effective when integrated within the per-component loss, confining the reweighting to each component's spatial context. On the BraTS-METS 2025 dataset (260 test cases), multi-class CC loss improves foreground Dice (0.64 +/- 0.26 vs. 0.59 +/- 0.27 baseline) and rare-class Dice, while maintaining Panoptic Quality at DSC threshold 0.5. Multi-class blob loss achieves the best Panoptic Quality at threshold 0.5 (0.40 +/- 0.24 vs. 0.38 +/- 0.25 baseline) and recognition quality (0.53 +/- 0.29 vs. 0.49 +/- 0.30). Integrating inverse-size weighting within the per-component loss increases rare-class Dice to 0.44 +/- 0.36 at the cost of reduced detection quality.
Learning from Noisy Prompts: Saliency-Guided Prompt Distillation for Robust Segmentation with SAM
Segmentation is central to clinical diagnosis and monitoring, yet the reliability of modern foundation models in medical imaging still depends on the availability of precise prompts. The Segment Anything Model (SAM) offers powerful zero-shot capabilities, although it collapses under the weak, generic, and noisy prompts that dominate real clinical workflows. In practice, annotations such as centerline points are coarse and ambiguous, often drifting across neighboring anatomy and misguiding SAM toward inconsistent or incomplete masks. We introduce SPD, a Saliency-Guided Prompt Distillation framework that converts these unreliable cues into robust guidance. SPD first learns data-driven anatomical priors through a lightweight saliency head to obtain confident localization maps. These priors then drive Contextual Prompt Distillation, which validates and enriches noisy prompts using cues from anatomically adjacent slices, producing a consensus prompt set that matches the behavior of expert reasoning. A Pairwise Slice Consistency objective further enforces local anatomical coherence during segmentation. Experiments on four challenging MRI and CT benchmarks demonstrate that SPD consistently outperforms existing SAM adaptations and supervised baselines, delivering large gains in both region-based and boundary-based metrics. SPD provides a practical and principled path toward reliable foundation model deployment in clinical environments where only imperfect prompts are available.
MAE-Based Self-Supervised Pretraining for Data-Efficient Medical Image Segmentation Using nnFormer
Transformer architectures, including nnFormer,have demonstrated promising results in volumetric medical image segmentation by being able to capture long-range spatial interactions. Although they have high performance, these models need large quantities of labeled training data and are also likely to overfit and become training unstable. This is a serious practical problem because it is not only time-consuming but also expensive to obtain medical images that are annotated by experts. Moreover, fully supervised traditional training pipelines do not take advantage of the available large amounts of unlabeled medical imaging data that can be easily obtained in the clinics. We have solved these drawbacks by advancing the efficiency of the nnFormer with a self-supervised pretraining framework, which is based on the Masked Autoencoders (MAE). In this method, the model is pretrained on unlabeled volumetric medical images to reconstruct randomly masked parts of the input. This allows the encoder to learn meaningful anatomical and structural representations . The encoder is then further fine-tuned on a labeled dataset on the downstream segmentation task. Conducted Experiment shows that the offered method leads to a higher segmentation performance on the count of Dice score, a quicker convergence rate on the course of the fine-tuning procedure, and a superior generalization on the basis of limited labeled data . These findings validate that self-supervised learning combined with transformer-based segmentation models is an appropriate approach to the problem of data shortage in medical image analysis.
CrossPan: A Comprehensive Benchmark for Cross-Sequence Pancreas MRI Segmentation and Generalization
Automatic pancreas segmentation is fundamental to abdominal MRI analysis, yet deep learning models trained on one MRI sequence often fail catastrophically when applied to another-a challenge that has received little systematic investigation. We introduce CrossPan, a multi-institutional benchmark comprising 1,386 3D scans across three routinely acquired sequences (T1-weighted, T2-weighted, and Out-of-Phase) from eight centers. Our experiments reveal three key findings. First, cross-sequence domain shifts are far more severe than cross-center variability: models achieving Dice scores above 0.85 in-domain collapse to near-zero (<0.02) when transferred across sequences. Second, state-of-the-art domain generalization methods provide negligible benefit under these physics-driven contrast inversions, whereas foundation models like MedSAM2 maintain moderate zero-shot performance through contrast-invariant shape priors. Third, semi-supervised learning offers gains only under stable intensity distributions and becomes unstable on sequences with high intra-organ variability. These results establish cross-sequence generalization-not model architecture or center diversity-as the primary barrier to clinically deployable pancreas MRI segmentation. Dataset and code are available at https://crosspan.netlify.app/.
Align then Refine: Text-Guided 3D Prostate Lesion Segmentation
Automated 3D segmentation of prostate lesions from biparametric MRI (bp-MRI) is essential for reliable algorithmic analysis, but achieving high precision remains challenging. Volumetric methods must combine multiple modalities while ensuring anatomical consistency, but current models struggle to integrate cross-modal information reliably. While vision-language models (VLMs) are replacing the currently used architectural designs, they still lack the fine-grained, lesion-level semantics required for effective localized guidance. To address these limitations, we propose a new multi-encoder U-Net architecture incorporating three key innovations: (1) an alignment loss that enhances foreground text-image similarity to inject lesion semantics; (2) a heatmap loss that calibrates the similarity map and suppresses spurious background activations; and (3) a final-stage, confidence-gated multi-head cross-attention refiner that performs localized boundary edits in high-confidence regions. A phase-scheduled training regime stabilizes the optimization of these components. Our method consistently outperforms prior approaches, establishing a new state-of-the-art on the PI-CAI dataset through enhanced multi-modal fusion and localized text guidance. Our code is available at https://github.com/NUBagciLab/Prostate-Lesion-Segmentation.
AI Approach for MRI-only Full-Spine Vertebral Segmentation and 3D Reconstruction in Paediatric Scoliosis
MRI is preferred over CT in paediatric imaging because it avoids ionising radiation, but its use in spine deformity assessment is largely limited by the lack of automated, high-resolution 3D bony reconstruction, which continues to rely on CT. MRI-based 3D reconstruction remains impractical due to manual workflows and the scarcity of labelled full-spine datasets. This study introduces an AI framework that enables fully automated thoracolumbar spine (T1-L5) segmentation and 3D reconstruction from MRI alone. Historical low-dose CT scans from adolescent idiopathic scoliosis (AIS) patients were converted into MRI-like images using a GAN and combined with existing labelled thoracic MRI data to train a U-Net-based model. The resulting algorithm accurately generated continuous thoracolumbar 3D reconstructions, improved segmentation accuracy (88% Dice score), and reduced processing time from approximately 1 hour to under one minute, while preserving AIS-specific deformity features. This approach enables radiation-free 3D deformity assessment from MRI, supporting clinical evaluation, surgical planning, and navigation in paediatric spine care.
SGP-SAM: Self-Gated Prompting for Transferring 3D Segment Anything Models to Lesion Segmentation
Large segmentation foundation models such as the Segment Anything Model (SAM) have reshaped promptable segmentation in natural images, and recent efforts have extended these models to medical images and volumetric settings. However, directly transferring a 3D SAM-style model to lesion segmentation remains challenging due to (i) weak spatial representational capacity for small, irregular targets in intermediate features, and (ii) extreme foreground-background imbalance in 3D volumes.We propose SGP-SAM, a self-gated prompting framework for efficient and effective transfer to 3D lesion segmentation. Our key component, the Self-Gated Prompting Module (SGPM), performs conditional multi-scale spatial enhancement: a lightweight multi-channel gating unit predicts whether the current features require additional multi-scale fusion, and only then activates a Multi-Scale Feature Fusion Block to enrich spatial context. To further address small-lesion learning, we design a Zoom Loss that up-weights lesion-focused supervision by combining Dice and a voxel-balanced focal term.Experiments on MSD Liver Tumor and MSD Brain Tumor (enhancing tumor) show consistent gains over strong transfer baselines based on SAM-Med3D. On MSD Liver Tumor, SGP-SAM improves mDice by 7.3% over fine-tuning.
A Guideline-Aware AI Agent for Zero-Shot Target Volume Auto-Delineation
Delineating the clinical target volume (CTV) in radiotherapy involves complex margins constrained by tumor location and anatomical barriers. While deep learning models automate this process, their rigid reliance on expert-annotated data requires costly retraining whenever clinical guidelines update. To overcome this limitation, we introduce OncoAgent, a novel guideline-aware AI agent framework that seamlessly converts textual clinical guidelines into three-dimensional target contours in a training-free manner. Evaluated on esophageal cancer cases, the agent achieves a zero-shot Dice similarity coefficient of 0.842 for the CTV and 0.880 for the planning target volume, demonstrating performance highly comparable to a fully supervised nnU-Net baseline. Notably, in a blinded clinical evaluation, physicians strongly preferred OncoAgent over the supervised baseline, rating it higher in guideline compliance, modification effort, and clinical acceptability. Furthermore, the framework generalizes zero-shot to alternative esophageal guidelines and other anatomical sites (e.g., prostate) without any retraining. Beyond mere volumetric overlap, our agent-based paradigm offers near-instantaneous adaptability to alternative guidelines, providing a scalable and transparent pathway toward interpretability in radiotherapy treatment planning.
Volumetric Directional Diffusion: Anchoring Uncertainty Quantification in Anatomical Consensus for Ambiguous Medical Image Segmentation
Ambiguous 3D medical image segmentation often involves boundaries where different expert delineations are non-identical yet clinically plausible. Modeling such inter-observer variability requires a careful balance between diversity and anatomical fidelity: deterministic models preserve coherent volumetric structures but collapse expert disagreement into a single mask, while stochastic generative models can produce diverse samples but may introduce disconnected components or slice-to-slice inconsistency when generating full 3D masks from unstructured noise. We propose Volumetric Directional Diffusion (VDD), a prior-anchored diffusion framework that shifts stochastic generation from full-mask synthesis to residual boundary exploration. VDD uses a coarse consensus prediction as an anatomical anchor and learns a directional diffusion process to generate plausible boundary variations around ambiguous regions while preserving stable volumetric topology. Experiments on three multi-rater datasets, including LIDC-IDRI, KiTS21, and ISBI 2015, show that VDD improves uncertainty distribution alignment while maintaining competitive segmentation accuracy and 3D structural consistency. These results suggest that prior-anchored residual diffusion can model clinically plausible expert disagreement without sacrificing anatomical fidelity.
Federated Learning for Cross-Modality Medical Image Segmentation via Augmentation-Driven Generalization
Purpose: Developing generalizable medical image segmentation models is challenging because imaging data are distributed across institutions and differ in modality and acquisition protocol. Federated learning (FL) enables collaborative training without centralizing raw medical images, but cross-modality domain shifts between computed tomography (CT) and magnetic resonance imaging (MRI) can substantially reduce model performance. This study investigates augmentation-driven cross-modality FL for abdominal organ and whole-heart segmentation. Methods: We evaluate convolution-based spatial augmentation, frequency-domain argumentation, domain-specific normalization, and global intensity nonlinear (GIN) augmentation for multimodal segmentation. Abdominal organ segmentation and whole-heart segmentation are first evaluated using a 2D U-Net framework. For whole-heart segmentation, we additionally perform native 3D experiments using a self-configuring nnU-Net architecture on the CARE-WHS 2026 dataset, enabling evaluation of whether the observed cross-modality FL behavior persists when moving from slice-based 2D segmentation to volumetric 3D segmentation. Results: GIN provides the most consistent cross-modality performance among the evaluated approaches in the original 2D experiments. For pancreas segmentation, the Dice similarity coefficient (DSC) improved from 0.073 to 0.437 when CT data were incorporated through federated cross-modality training. In 3D whole-heart segmentation, FedGIN improved mean DSC over FedAvg from 0.8696 to 0.8901 on the unseen CT center and from 0.7160 to 0.7956 on the unseen MRI center. Relative to centralized GIN training, FedGIN retained 92.4% of performance on unseen CT data and achieved comparable performance on unseen MRI data (0.7956 versus 0.7937).
MedVL-SAM2: A unified 3D medical vision-language model for multimodal reasoning and prompt-driven segmentation
Recent progress in medical vision-language models (VLMs) has achieved strong performance on image-level text-centric tasks such as report generation and visual question answering (VQA). However, achieving fine-grained visual grounding and volumetric spatial reasoning in 3D medical VLMs remains challenging, particularly when aiming to unify these capabilities within a single, generalizable framework. To address this challenge, we proposed MedVL-SAM2, a unified 3D medical multimodal model that concurrently supports report generation, VQA, and multi-paradigm segmentation, including semantic, referring, and interactive segmentation. MedVL-SAM2 integrates image-level reasoning and pixel-level perception through a cohesive architecture tailored for 3D medical imaging, and incorporates a SAM2-based volumetric segmentation module to enable precise multi-granular spatial reasoning. The model is trained in a multi-stage pipeline: it is first pre-trained on a large-scale corpus of 3D CT image-text pairs to align volumetric visual features with radiology-language embeddings. It is then jointly optimized with both language-understanding and segmentation objectives using a comprehensive 3D CT segmentation dataset. This joint training enables flexible interaction via language, point, or box prompts, thereby unifying high-level visual reasoning with spatially precise localization. Our unified architecture delivers state-of-the-art performance across report generation, VQA, and multiple 3D segmentation tasks. Extensive analyses further show that the model provides reliable 3D visual grounding, controllable interactive segmentation, and robust cross-modal reasoning, demonstrating that high-level semantic reasoning and precise 3D localization can be jointly achieved within a unified 3D medical VLM.
ReFRM3D: A Radiomics-enhanced Fused Residual Multiparametric 3D Network with Multi-Scale Feature Fusion for Glioma Characterization
Gliomas are among the most aggressive cancers, with complex diagnostic processes. Existing glioma segmentation methods often struggle with high variability in imaging data and inadequate optimization. Furthermore, radiomic analysis is typically applied only after segmentation is finished, limiting its ability to inform the segmentation process itself. To address these challenges, we propose a novel radiomics-enhanced fused residual multiparametric 3D network (ReFRM3D) for brain tumor characterization. The framework is based on a 3D U-Net architecture and features multi-scale feature fusion, hybrid upsampling, and an extended residual skip mechanism. Additionally, we introduce a radiomic conditioning mechanism that extracts texture and intensity descriptors from an intermediate coarse segmentation and re-injects them into the decoder to refine the final output. Experimental results on BraTS2019, BraTS2020, and BraTS2021 show strong performance, with mean DSC values of 93.45%, 93.61%, and 92.06%, respectively, across whole tumor, enhancing tumor, and tumor core regions. Compared with recent models, ReFRM3D improves average DSC by 5.79%, 7.25%, and 0.96% on these datasets. Our model also generalized well on the BraTS-Africa dataset with an average DSC of 87.8%, despite differences in scanner field strength and patient demographics.