Medical Imaging Foundation Models

Momentum

24 papers in the last four weeks, up 167% on the four weeks before. 0.2% of all new papers.

Jul 13Week of Sep 28

Latest papers 150

Jul 27, 2026cs.CV

Color Fundus Photography Analysis: Co-evolution of Data, Preprocessing, and Modeling toward Multimodal AI

Color Fundus Photography (CFP) is a primary non-invasive imaging modality for large-scale screening of ophthalmic and systemic diseases. Existing surveys mainly summarize task-specific algorithms, datasets, or preprocessing techniques independently, lacking a unified perspective on their co-evolution with modern artificial intelligence. This review provides an integrated overview of CFP AI through the interplay of dataset evolution, preprocessing paradigms, and modeling frameworks. We show that CFP datasets have evolved from small single-center collections with task-specific labels to large multi-center resources featuring multimodal pairings and longitudinal clinical records. Preprocessing has progressed from conventional image enhancement to neural data-engineering pipelines, hardware-aware token optimization, and self-supervised imputation for incomplete electronic health records (EHRs). Meanwhile, modeling has advanced from convolutional neural networks (CNNs) to vision foundation models, state space models (SSMs), and multimodal expert architectures. At the multimodal frontier, CFP is increasingly integrated with EHRs and longitudinal patient information, enabling more comprehensive clinical reasoning beyond isolated image analysis. We conclude that future progress depends on the collaborative optimization of datasets, preprocessing, and multimodal modeling, providing a roadmap toward robust clinical deployment, improved cross-domain generalization, and resource-efficient edge intelligence.
Jul 22, 2026cs.CV

Self-supervision drives representational convergence in medical foundation models more than clinical supervision

Medical image encoders from different groups are increasingly treated as interchangeable, on the assumption that scale and clinical supervision concentrate their representations onto a shared structure. Whether this convergence is real, what produces it, and whether it is clinically usable are untested, and the similarity measures behind such claims are fragile. We present a controlled dissection across 18 image and 7 text encoders, all open-weight and run locally, spanning 7M to 27B parameters and five imaging modalities, including 650,982 chest radiographs from six datasets. To isolate cause, we train encoders that vary only the objective under fixed data, architecture, and scale, and reproduce the effect in a synthetic model. Convergence is modest but above a random floor, driven by the self-supervised objective, not clinical supervision: matched self-supervised encoders aligned most (40.4% on chest radiography), with label-supervised (21.1%) and image-text (3.3%) far lower, and did not grow with size (Spearman 0.302, p=0.223) or capability. It is within-modality, does not reach clinical language, and does not reproduce how radiologists judge case similarity. Yet a linear classifier transfers across encoders and to five held-out hospitals, retaining about 85% of within-encoder performance. Convergence in medical imaging is therefore set by the pretraining objective, not inherited from scale or clinical supervision. Interoperability is accordingly something to design for through that objective, and to validate where the shared geometry is weakest, across patient subgroups and against clinical judgment.
Jul 22, 2026cs.CV

Development of an automated, reliable, and clinically meaningful artificial intelligence (AI) tool for diagnosing cardiac disease from conventional cardiovascular magnetic resonance (CMR) images

Aims: Cardiovascular magnetic resonance (CMR) imaging enables non-invasive assessment of myocardial structure, function, and pathology, but requires substantial experience in interpretation of CMR images that could be supported by artificial intelligence (AI)-based models. However, use of AI models for enhanced CMR reading is limited by labor-intensive data curation, suboptimal model performance, and unclear implementation pathways. Methods and results: We developed an automated data curation pipeline for CMR-based cardiovascular disease (CVD) diagnosis, integrating open-source locally-run large language models (LLMs) to extract diagnostic labels from narrative CMR reports and preprocessing multimodal imaging data, including cine and late-gadolinium-enhancement (LGE) CMR sequences. Three vision foundation models (DINO, VST, UMedPT) were fine-tuned across these modalities in a two-stage approach. The dataset comprised hypertrophic cardiomyopathy (HCM), dilated cardiomyopathy (DCM), ischemic cardiomyopathy (ICM), cardiac amyloidosis (CA), and normal controls (NOR). A total of 988 curated cases were randomly divided into 742 for training and 246 for validation. Fine-tuned AI-models achieved high discriminative diagnostic performance on an independent test set comprising 1067 patients , with individual AUC-ROC values of up to 0.937 for the correct diagnosis of HCM and 0.945 for cardiac amyloidosis. Ensemble strategies combining multiple models and modalities further improved AI-based diagnostic accuracy and robustness, achieving the highest overall diagnostic performance for HCM (AUC=0.959, CI [0.936-0.978]), CA (AUC=0.966, CI [0.939-0.986]), NOR (AUC=0.872, CI [0.852-0.894]), DCM (AUC=0.848, CI [0.808-0.885]) and ICM (AUC=0.840, CI [0.809-0.868]). All training and inference code, along with the trained model weights, are publicly available on https://github.com/sinaamirrajab/CMR_CVD.
Jul 20, 2026cs.LG

CANDOR: Chance-Calibrated Neighborhood Discordance in Frozen Encoders for Medical Imaging

A foundation encoder is pretrained once on a large image corpus and then reused with its weights frozen. Each new task is solved by training a small head on the features it produces. This setup is common in medical imaging, where labeled cases are scarce and a frozen encoder can be reused across findings. All downstream tasks then depend on the class separation present in that fixed feature space. Encoder selection usually uses the area under the receiver operating characteristic curve (AUROC) of a trained downstream head. AUROC measures the predictive information a head can extract from the features, but it does not measure class separation in the frozen feature space. A positive image that lies near a negative image in feature space has a bounded normalized margin under any Lipschitz head. Chance-calibrated neighborhood discordance (CANDOR) measures this feature-space separation without training a head. For a positive image, it compares the k nearest positive-label neighbors with the k nearest negative-label neighbors, among images acquired the same way. Discordance rate D is the share of positives whose opposite-label neighbors are nearer. Drawing the 2 candidate sets at equal size makes the labels interchangeable, so label-independent features have chance level D=1/2 without simulation. We apply CANDOR to 22 frozen encoders on 605,443 images from 20 public datasets, covering 8 binary tasks in 7 domains. On every task, the best encoder is below 1/2. A discordant image bounds the normalized margin of every Lipschitz head on that encoder. A selector that is shown the true label and chooses among 11 encoders reduces the miss rate from 0.359 to 0.028. Discordance is associated with occlusion retention and with none of pretraining objective, parameter count, release year, or finding size. The fixed chance level lets D be computed for a frozen encoder before any downstream head is trained.
Jul 20, 2026cs.CV

SAMRI-3D: Adapting SAM2 for 3D MRI Segmentation with Global Volume Tokens

Foundation models such as Segment Anything Model 2 (SAM2) have transformed natural-image and video segmentation, and recent work has begun adapting them to medical imaging. These adaptations, however, are largely general-purpose models that treat MRI as one modality among many; large-scale, MRI-specific modelling and benchmarking remain limited, even though MRI's low soft-tissue contrast leaves many boundaries effectively invisible on individual slices. We present SAMRI-3D, a benchmark and method for 3D MRI segmentation with SAM2. The SAMRI-3D benchmark is the largest MRI-only evaluation to date - 10,392 volumes from 34 datasets (27 public, 7 in-house) spanning 12 anatomical domains and 10+ sequences, with explicit seen/unseen splits. Freezing the image encoder and fine-tuning only the lightweight decoder and memory modules raises mean Dice from 0.58 (zero-shot SAM2) to 0.76, surpassing recent SAM-based medical models (SAMed-2 0.69, Medical-SAM2 0.49, SAM-Med3D 0.37) with strong statistical significance. To target invisible boundaries, we introduce Global Volume Tokens (GVT): persistent memory tokens trained with a Truncated Signed Distance Field (TSDF) reconstruction objective that is discarded at inference (zero added cost). This full model, SAMRI-3D, attains the best accuracy (0.78) and lowest variance across all 34 datasets and, uniquely, shows no drop on 8 held-out datasets (0.79 unseen vs. 0.78 seen); per-sequence analysis confirms the TSDF objective helps most where per-slice contrast is weakest. We will release the benchmark, code, and models in this paper.
Jul 20, 2026cs.CV

BrainNext: A General-Purpose Self-Supervised Foundation Model for Brain MRI Analysis

Foundation models pretrained using self-supervised learning have transformed computer vision by learning transferable representations from large-scale unlabeled data. However, existing foundation models for neuroimaging remain limited by task-specific training, slice-based learning strategies, or relatively small pretraining datasets, restricting their generalizability across diverse brain MRI applications. In this work, we present BrainNext, a general-purpose self-supervised foundation model for volumetric brain MRI analysis. BrainNext combines masked autoencoder (MAE) pretraining with a native three-dimensional Bi-Directional xLSTM-UNet architecture to learn rich anatomical representations from 60,551 unlabeled brain MRI examinations spanning multiple MRI modalities. The pretrained model is subsequently adapted to downstream tasks through lightweight task-specific fine-tuning. We evaluate BrainNext on the Foundation Models for Medical Imaging (FOMO) 2025 Method Track, encompassing classification, segmentation, and brain-age estimation, where it achieved second place overall and ranked first in the meningioma segmentation task on the official FOMO 2025 challenge leaderboard, demonstrating strong transferability across heterogeneous neuroimaging tasks. These results highlight the potential of large-scale self-supervised pretraining to learn robust and transferable volumetric representations, establishing BrainNext as a scalable foundation model for diverse brain MRI applications.
Jul 19, 2026cs.CV

Induce to Empower: Improving Lightweight Baselines via Foundation Model Induction for Generalized Polyp Segmentation

Automated polyp segmentation in colonoscopy continues to pose challenges due to substantial appearance variations and indistinct polyp boundaries. Although emerging foundation models (FMs) such as DINOv2, SAM, and OneFormer, demonstrate remarkable generalization capabilities, their direct transfer to the polyp segmentation task and deployment in real-time clinical settings are difficult due to lack of large-scale labeled data and high computational demands. In addition, adopting multiple FMs together raises concerns, even though they encode complementary semantic and structural information. While lightweight models, including U-Net, PraNet and U-Net++, are computationally efficient, they often struggle to generalize across datasets due to limited representational capacity. To address this gap, we propose Lite-Polyp Inductor (Lite-Pi), a novel foundation model induction framework that significantly enhances lightweight polyp segmentation baselines. Our proposed framework generates FM-specific prototype representations and aligns them semantically with the corresponding foundation model priors through reconstruction-based supervision. Subsequently, transformer-based fusion is introduced to highlight the polyp relevant representations, including salient boundary information, while preserving complementary semantic cues. Extensive experiments across five polyp segmentation benchmark datasets demonstrate that Lite-π significantly improves lightweight baselines, achieving superior generalization performance with minimal computational overhead and thereby, offering a practical solution for generalized polyp segmentation. Our code is available at GitHub. https://github.com/lostinrepo/Lite-Pi
Jul 15, 2026cs.CV

RegionFM: Interpretable Region-Based Brain MRI Classification Using Foundation Model Embeddings

Foundation models provide powerful representations for brain MRI analysis, but their predictions remain difficult to interpret in anatomically meaningful terms. Clinical assessment of brain MRI is commonly organized around anatomically defined structures and regional abnormalities, whereas conventional explanation methods typically produce voxel- or patch-level importance maps that do not explicitly quantify the contributions of individual brain regions. To address this mismatch, we propose RegionFM, an interpretable framework that integrates anatomical segmentation with brain MRI foundation-model embeddings. RegionFM first divides each MRI scan into anatomical regions and constructs a separate MRI volume for each region. A frozen foundation model then encodes each region into an embedding, and a region-additive logistic model combines these embeddings such that every anatomical region contributes an explicit scalar term to the final prediction. This formulation supports both subject-level and cohort-level analyses of regional contributions. We evaluate RegionFM on cognitive-impairment classification using embeddings from multiple pretrained brain MRI foundation models. The results show that RegionFM maintains performance comparable to less interpretable fine-tuning approaches while providing anatomically grounded explanations. Randomized embedding ablations yield near-chance performance, indicating that the predictions rely on meaningful structure captured by the foundation-model embeddings rather than simple feature statistics. Overall, RegionFM better aligns model explanations with anatomy-based clinical reasoning while maintaining competitive predictive performance.
Jul 14, 2026cs.CV

UniMedSeg: Unified In-Context Learning for Multi-Paradigm 2D/3D Medical Image Segmentation

Medical image segmentation foundation models are expected to generalize across diverse clinical scenarios, yet existing universal methods remain fragmented by prompt paradigms and spatial dimensions. Visual in-context learning, interactive segmentation, and language-guided segmentation are typically handled by paradigm-specific models, while 2D and 3D images are also modeled separately. Such isolation prevents heterogeneous annotations and data from being jointly absorbed by a single scalable model and limits cross-paradigm knowledge transfer. To address this bottleneck, we propose UniMedSeg, a Transformer-centric universal segmentation framework that maps visual examples, geometric interactions, language instructions, and 2D/3D images into a shared sequence space, enabling heterogeneous medical supervision to be jointly learned through a unified in-context interface without prompt- or dimension-specific branches. To overcome the long-sequence memory bottleneck caused by visual contexts, we introduce Decoupled Split Attention, which reduces attention complexity to linear while preserving hardware-friendly computation and focused context-target interaction. Extensively trained and evaluated on a large corpus curated from 27 public datasets, UniMedSeg achieves state-of-the-art performance across visual in-context, interactive, and language-guided segmentation without task-specific fine-tuning, demonstrating strong generalization on diverse held-out tasks. The code and model weights are publicly available at https://github.com/Lii1228/UniMedSeg
Jul 13, 2026cs.CV

A Unified Framework for Comprehensive Cardiac CT Segmentation and Phenotyping: Human-in-the-Loop Data Annotation, Vision Foundation Model Development, Multicenter Evaluation and Clinical Validation

Comprehensive quantification of cardiac structures from computed tomography (CT) remains limited not by data availability but by the scalability of measurements, which makes routine use impractical. Here we present a unified framework for comprehensive cardiac CT segmentation and phenotyping that combines a human-in-the-loop annotation pipeline, a cardiac CT augmentation technique, and a self-supervised foundation model pre-trained on 60,000 unlabeled cardiac CT scans. Using this approach, we assembled the largest and most comprehensive expert-annotated cardiac CT segmentation dataset to date, comprising 1598 cases and 14 distinct cardiac structures (1000 for training, 598 for the external test set). Across five external datasets, the framework segmented all structures more accurately and comprehensively than existing open-source tools. Self-supervised pre-training improved labeling efficiency, with the most significant gains observed during external evaluation in the low-data regime. Benchmarking across convolutional, transformer, and state-space architectures showed comparable performance, indicating that data quality and pre-training, rather than architecture, drove accuracy. The framework was scaled to population-level phenotyping, with segmented anatomy that carries functionally relevant information about ventricular function and disease severity beyond demographic variables. By openly releasing the largest dataset with human labels, code, model weights, a CT augmentation library, and software, this work provides a reproducible foundation for opportunistic cardiac phenotyping from routinely acquired CT scans.
Jul 11, 2026cs.CV

Benchmarking the Robustness of Foundation Models for Mammography under Domain Shift

Foundation models are increasingly used as image feature extractors for mammography, but their robustness under external domain shift remains unclear. We benchmark 15 foundation-model backbones across breast density, BI-RADS severity, and cancer status using a unified frozen-backbone linear-probe protocol, training on 3 source datasets and evaluating on 12 task-compatible out-of-distribution (OOD) datasets after label harmonization. Mammography-specific vision-language models (Mammo-FM and MaMA) provide the strongest mean OOD performance, but robustness is not explained by mammography exposure alone. DINOv3 remains a competitive vision-only baseline, and mammography-adapted pretraining does not consistently improve generalization. Dataset-level analysis further shows that even leading models show heterogeneous performance across datasets. Feature-space inspection reveals that useful representations can preserve clinical signal while retaining dataset and acquisition structure. These findings highlight dataset-level OOD evaluation as a central criterion for assessing mammography representations. Our code is publicly available: https://github.com/biomedia-mira/mammo-ood.
Jul 9, 2026cs.CV

CT-CLIP Representations for Multimodal Lung Cancer Survival Prediction

Accurate prognosis prediction is important for treatment planning in lung cancer, but deep learning-driven survival modelling is often limited by the scarcity of curated imaging cohorts with reliable outcome data. This study evaluates whether representations from a domain-specific foundation model can be used for multimodal survival prediction in data-constrained clinical settings. We assess the foundation model CT-CLIP as a feature extractor for pretreatment computed tomography images and clinical variables from 242 diagnosed lung cancer patients. The evaluation includes adaptation strategies based on frozen encoders, full fine-tuning, and low-rank adaptation, together with modality ablations and comparisons with clinical and multimodal baselines. The results show that a frozen CT-CLIP model combined with a trainable lightweight survival head outperforms the clinical baseline and achieves comparable or improved performance relative to other multimodal approaches, and separates patients into clinically meaningful high- and low-risk groups.
Jul 8, 2026cs.CV

MedPMC: A Systematic Framework for Scaling High-Fidelity Medical Multimodal Data for Foundation Models

Medicine is inherently multimodal, requiring clinicians to synthesize information across diverse data streams. Yet the development of multimodal foundation models is constrained by limited access to large-scale, high-quality clinical data. Although PubMed Central (PMC) offers a complementary source of expert-authored image-text data, existing PMC-derived resources remain limited in fidelity, reproducibility, and clinical validation. We introduce MedPMC, an automated, continuously updatable framework that transforms permissively licensed literature into high-fidelity infrastructure for medical multimodal models. Applied to 6.1 million PMC articles, MedPMC curated 11 million medical image-text pairs. Component evaluations showed strong performance for initial screening (F1 = 93.2), multi-panel figure detection (F1 = 96.5), figure separation (mAP = 89.8), caption separation and alignment (F1 = 81.4; ROUGE-L = 85.3), and medical figure classification (F1 = 96.5). Manual review by five annotators, three with medical training, found 95.3% of MedPMC images medically relevant, versus 19.7% in a prior PMC-derived dataset. Across 26 benchmarks spanning 11 specialties, a MedPMC-trained CLIP-style model improved average zero-shot AUC by 7.1 percentage points over the strongest architecture-matched biomedical CLIP baseline despite using fewer than half as many image-text pairs. As the vision encoder in a multimodal large language model, it improved medical visual question-answering by 1.9 and 16.9 percentage points across two benchmarks. In 10,524 Yale New Haven Health System dermatology photographs, it improved morphology-to-image retrieval Recall@5 by 11.7 percentage points. These findings show that high-fidelity literature curation strengthens medical multimodal foundation models across benchmark and clinical settings. We publicly release the framework, corpus, benchmarks, and pretrained models.
Jul 8, 2026cs.CV

Vision Foundation Models in Radiology: A Scoping Review of Data, Methodology, Evaluation and Clinical Translation

Vision foundation models (VFMs) are increasingly being developed for radiological imaging, yet their definition, development and evaluation remain heterogeneous. We conducted a PRISMAScR scoping review of peer-reviewed studies published between January 2017 and March 2026 describing foundation models trained exclusively on radiological imaging data. Sixty-seven studies were included and mapped across three pillars: data scale and heterogeneity, architectural and pretraining scalability, and downstream transferability and generalization. Datasets primarily covered brain MRI, thoracoabdominal CT, and chest X-ray, ranging from fewer than 100,000 samples to multi-million-image cohorts. Transformer-based architectures and self-supervised pretraining predominated, particularly masked image modeling, contrastive learning and multi-stage approaches. Evaluation focused mainly on segmentation and classification, whereas cross-center, cross-scanner, anatomical and modality-shift validation was inconsistently reported. Alignment with FUTURE-AI principles was uneven. Overall, radiology-specific VFMs show promising transferability, but clinical translation remains constrained by limited data representativeness, heterogeneous benchmarks, incomplete reporting and insufficient deployment-oriented evaluation.
Jul 8, 2026cs.CV

HPR-SAM: Hierarchical Probabilistic Representation Learning for Prompt-free SAM-based Medical Image Segmentation

Prompt-free adaptation of the Segment Anything Model (SAM) has emerged as a promising paradigm for automatic medical image segmentation. Existing methods mainly focus on prompt generation, while overlooking that prompt quality is fundamentally constrained by the expressiveness of anatomical representations. However, deterministic prototypes or semantic tokens are insufficient to jointly capture global anatomical priors, intra-structure diversity, and local structural reliability. To address this limitation, we propose the Hierarchical Probabilistic Representation (HPR) framework, which learns complementary anatomical representations through Distributional Anatomical Representation (DAR), Multi-component Anatomical Representation (MAR), and Local Reliability Representation (LRR), and integrates their predictions via Hierarchical Prediction Fusion (HPF) while remaining compatible with the original SAM decoder. Experiments on the Synapse, LA, and PROMISE12 datasets demonstrate that HPR-SAM achieves state-of-the-art performance on Synapse and the best performance under few-shot settings on LA and PROMISE12, validating the effectiveness of the proposed hierarchical probabilistic representation learning framework for prompt-free medical image segmentation. Code is available at https://anonymous.4open.science/r/HPR-SAM-E4AF.
Jul 6, 2026cs.CL

RABBiT: Rapidly adaptive BOLD foundation model via brain-tuning for accurate zero-shot and few-shot prediction of speech-elicited responses in the brain

Language understanding in the brain is context-dependent, varying across experimental stimuli and individuals, which makes it difficult to build computational models that generalize across both. This calls for a foundation model of language-evoked brain activity that can capture shared structure while adapting efficiently to new participants and inputs. We introduce RABBiT (Rapidly Adaptive BOLD foundation model via BraIn-Tuning), a compact audio-to-fMRI encoder designed for accurate zero- and few-shot prediction. A comprehensive evaluation on 324 participants across multiple unseen fMRI datasets shows that RABBiT enables accurate zero-shot prediction of fMRI responses to natural speech across auditory and language-selective regions, surpassing the SOTA foundation model for fMRI and predictions based on group averages. With as little as 10 minutes of participant-specific data, RABBiT further improves performance via parameter-efficient tuning, substantially outperforming per-participant linear models. RABBiT's performance is driven by two key innovations: (1) learned region-specific attention, and (2) a decomposition of brain responses into shared and subject-specific components, combined with a brain-tuned speech backbone. In addition to supporting strong predictive accuracy, the structured, region-specific representations that RABBiT learns enable interpretability. By eliminating the need for extensive per-participant data and model fitting, RABBiT enables scalable population-level analyses of language in the human brain. We make the code available at https://github.com/bridge-ai-neuro/rabbit.
Jul 5, 2026cs.CV

Topology-Driven Transferability Estimation for 3D Medical Vision Foundation Models

The growing number of medical vision foundation models highlights the need for effective model selection. However, mainstream selection methods rely on exhaustive fine-tuning, which is computationally expensive. Most of the existing Transferability Estimation (TE) metrics are primarily designed for image-level classification. They fail to preserve spatial relationships and fine-grained boundary details, which are crucial for the segmentation task. Additionally, while image-level tasks typically process a single feature vector per input, dense prediction tasks in 3D medical imaging require voxel-wise evaluation against dense annotations. To bridge these gaps, we propose a \textit{non-parametric, topology-driven} framework that estimates transferability directly from the alignment between the sparse 1-skeleton graph of dense features and semantic labels via Minimum Spanning Trees (MST). We decouple the alignment into two complementary geometric scales: Local Boundary-Aware Topological Consistency (LBTC) to assess boundary separability, where we prove that the MST leakage rate serves as a finite-sample lower bound on the Bayes error; and Global Representation Topology Divergence (GRTD) to evaluate the overall anatomical layout. Crucially, we formally justify a counterintuitive mechanism: Although without fine-tuning, the randomly initialized segmentation decoder acts as a topology-preserving spatial projector, reducing the variance of pairwise distance estimates and stabilizing global alignment evaluation. Fused via a task-adaptive gating mechanism, these dual metrics adapt to diverse clinical complexities. Evaluated on a large-scale benchmark of 114,000 3D medical volumes across diverse anatomical tasks, our topological framework achieves state-of-the-art transferability estimation with an average weighted Kendall (outperforming by 0.36) while accelerating evaluation by 56 times.
Jul 1, 2026cs.CV

Foundation Models vs. Radiomics for Lung Computed Tomography: A Benchmark of Feature Extractors, Classification Heads, and Segmentation Choices

Radiomics is the established approach for CT-based lung cancer phenotyping, yet comparisons with foundation models rarely isolate contributions of feature extractor, classification head, and segmentation choice, or test cross-cohort robustness. We benchmark five feature extractors (Curia, Curia-2, DINOv3, Radiomics2D, Radiomics3D), seven classification heads (TabPFN, TabICL, XGBoost, CatBoost, Random Forest, logistic regression, Ridge), and three segmentation regimes on five tasks: tumor volume and stage classification, 2-year survival prediction, histology classification, and age prediction. Models are trained on LUNG1 (n=338) and evaluated on an internal test set (n=84) and the external LUNG2 cohort (n=211), with worst-case cross-cohort performance as the primary metric. The dominant design factor is task-dependent: segmentation drives volume and stage classification, while classifier choice drives survival, histology, and age prediction. Radiomics is competitive for tumor volume, tumor stage and survival (partly due to label-derivation effects for the former); Curia variants reach comparable peak scores for survival; DINOv3 falls slightly short across tasks. Patch and slice aggregation have negligible impact. We recommend Curia with tumor segmentation and a CatBoost head as a safe default, achieving the best mean rank across the three primary clinical tasks, though task-specific selection consistently outperforms any cross-task default. When tumor delineations are unavailable, Curia-2 with lung segmentation and logistic regression offers a competitive alternative. All pipelines use a two-stage design suited to small cohort sizes where end-to-end fine-tuning would risk overfitting.
Jul 1, 2026cs.CV

BrainFIBRE: A Foundation Model via Information Decomposition for Brain Microstructure

Diffusion MRI probes brain microstructure with particular sensitivity to early cerebrovascular and neurodegenerative changes. Neurite Orientation Dispersion and Density Imaging (NODDI) decomposes the diffusion signal into three biophysically interpretable maps: neurite density index (NDI), orientation dispersion index (ODI), and free water fraction (FWF), capturing neurite packing, fiber coherence, and extracellular fluid. These 3D maps offer a rich substrate for transferable microstructural representations, yet integrating them is challenging: standard representation learning struggles to disentangle the unique information in each map from their shared and synergistic interactions. We present BrainFIBRE, the first foundation model for brain microstructure, pretrained on NODDI-derived maps from 55,592 UK Biobank participants. We propose Self-supervised Partial Information Decomposition (SPID), which extends PID-guided multimodal learning to the self-supervised regime for the first time. A novel Counterfactual Candidate Construction (CCC) paradigm perturbs inter-modality alignment through modality dropping and swapping, providing the contrastive signal for a Mixture-of-Experts architecture to disentangle unique, synergistic, and redundant information without any downstream label. On both Caucasian and Asian cohorts, BrainFIBRE achieves state-of-the-art performance across diverse tasks predicting age, sex, cerebrovascular and neurodegenerative markers, and cognition, while yielding neurobiologically interpretable representations that reveal task- and cohort-specific interaction patterns. BrainFIBRE establishes a versatile foundation for neuroimaging analysis at the microstructural level.
Jul 1, 2026physics.med-ph

Closed-loop coupling of personalised and foundation models for real-time treatment guidance with MRI

Image-guided therapies, including radiotherapy, biopsy and deep brain stimulation, rely on real-time targeting of anatomical structures. However, in the presence of motion, imaging latencies create a temporal misalignment between observed and true anatomy, compromising treatment accuracy. Artificial intelligence-based frameworks have increasingly been presented to close this latency gap, but leading personalised models can fail due to a lack of stable anatomical grounding. Foundation models can provide grounded behaviour, but they do not adapt to real-time, individual patient dynamics. Here we introduce a closed-loop coupling framework that synergises patient-specific temporal prediction with continuous segmentation-based anatomical interpretation from a foundation model. A personalised model predicts future anatomy to compensate for system latency, while a streaming foundation model provides anatomical supervision used to continuously update the temporal predictor in real time during treatment. We validate the framework using a digital phantom and intrafraction magnetic resonance imaging (MRI) from patients undergoing MRI-guided radiotherapy. For a prediction horizon of 400 ms, the proposed method improves anatomical prediction and reduces dosimetric error compared with existing approaches, within clinically relevant latency constraints. These results establish closed-loop coupling as a general strategy for real-time image-guided intervention.
Jun 28, 2026cs.CV

SonoCLIP: Mask-Guided Region-Aware Vision-Language Pretraining for Fetal Ultrasound Analysis

Vision-language foundation models have shown strong potential in medical image analysis. Although foundation models for ultrasound imaging have recently emerged, the domain remains particularly challenging due to severe speckle noise, acquisition variability, and subtle anatomical boundaries, leading to high inter-observer variability. Existing CLIP-based models rely primarily on global image-text alignment, limiting their sensitivity to clinically decisive local structures. We propose SonoCLIP, the first million-scale region-controllable fetal ultrasound vision-language foundation model that integrates segmentation masks as mask-channel visual prompts within the vision encoder, enabling joint global-local contrastive representation learning. To support scalable region-text alignment, we introduce a sigmoid-based pairwise contrastive loss that improves stability under large-scale supervision. We further curate a 1.44M-image multimodal fetal ultrasound dataset spanning 24 standard planes for large-scale pretraining. Extensive cross-center evaluations demonstrate that SonoCLIP achieves superior zero-shot transfer performance under both global and mask-guided inference, establishing a controllable and clinically oriented foundation model for fetal ultrasound analysis. Our code and data are available at https://github.com/Harrison-one/SonoCLIP.
Jun 25, 2026cs.CV

Mask to Concept: Auto-Promptable SAM3 via Efficient Test-Time Concept Embedding Search for Few-Shot Annotation

Transforming foundation segmentation models from human-prompted tools into auto-promptable annotators is critical for scalable medical data annotation. Current methods commonly depend on external feature matchers or auxiliary networks to automate geometric prompting, but introducing architectural overhead and limiting performance scalability. Although SAM3 natively supports concept segmentation via reusable text prompts, its direct use in medical imaging is hindered by a lack of fine-grained clinical knowledge and the ambiguity of human-written descriptions. In this work, we propose Mask to Concept (M2C), an efficient framework that adapts SAM3 for medical few-shot annotation without external modules, parameter retraining, or manual text engineering. Using only a few labeled images, M2C enables SAM3 to automatically search for transferable visual concepts entirely within its frozen architecture: it initializes a learnable concept embedding, uses it to prompt segmentation, and updates the embedding by gradients of minimizing the concept segmentation error. We further introduce a Hybrid Uncertainty Estimation (HUE) module that calculates the prediction entropy and maps concept predictions back to the box prompts, measuring concept-geometry prompting inconsistency. Highly uncertain samples are flagged actively for human correction, and the corrected masks are then fed back to M2C to continuously search for more precise concept embeddings, forming a self-enhancing annotation loop with minimal expert effort. Experiments on medical segmentation benchmarks show that our method achieves SOTA few-shot segmentation performance and outstanding annotation efficiency, offering a practical and efficient pathway toward scalable medical image labeling. Codes are at https://github.com/Huster-Hq/M2C.
Jun 23, 2026cs.CV

Jolia: Concept-Level Vision-Language Alignment for 3D CT Contrastive Learning

Vision-language contrastive pretraining has become the dominant recipe for 3D medical foundation models, leveraging the large volumes of paired scans and reports produced in clinical practice. However, medical images usually span dozens of organs, and radiological reports are much longer than typical natural image captions and are composed of multiple structured sections. CLIP-style pretraining compresses this structure by encoding each modality into a single global token, at the risk of losing important details. We introduce ConQuer (Concept Queries), an image-text pretraining method that augments CLIP's global alignment with a set of localized alignments, one per concept. ConQuer splits the report into concept-specific sections and learns cross-attention queries that pool the matching image features without using any segmentation mask or spatial supervision. Contrastive learning is then applied independently for each concept. Concepts can be any unit of semantic localization; here, they are anatomical regions, one query per organ or gross body region. As a byproduct, each query learns attention maps focused on its concept, providing built-in spatial interpretability. We use ConQuer to train Jolia, a 3D CT foundation model on chest and abdominal CT. Jolia consistently outperforms a CLIP baseline on findings classification, report generation, and cross-center transfer, and sets a new state of the art across multiple public benchmarks. Jolia's weights are available at https://huggingface.co/raidium/Jolia
Jun 21, 2026cs.CV

MaRS: Robust Out-of-Distribution Detection via Mahalanobis Residual Scoring

Foundation models provide highly descriptive representations for medical images, yet their reliability degrades under distribution shifts arising from changes in patients, devices, or acquisition conditions. Reliable out-of-distribution (OOD) detection is therefore essential for safe deployment. Recent post-hoc detectors efficiently exploit frozen embeddings (e.g., kNN), whereas reconstruction-based OOD detection in latent feature space has seen limited adoption due to inconsistent performance. In this work, we show that the limitation of reconstruction-based methods in latent space does not stem from poor reconstruction quality, but from how reconstruction errors are scored. Standard L2 residual norms collapse the anisotropic residual structure, thereby suppressing informative deviations. To address this limitation, we introduce MaRS (Mahalanobis Residual Scoring), a label-free OOD detector that learns an in-distribution manifold using a lightweight autoencoder and measures deviation via a Mahalanobis distance on reconstruction residuals, yielding variance-aware OOD scores. Across three imaging modalities, multiple types of distribution shift, and different model families and scales, MaRS outperforms established confidence-, distance-, and reconstruction-based baselines, while remaining fully post-hoc and lightweight. The code is available at https://github.com/francescodisalvo05/mars.
Jun 21, 2026cs.CV

Human and AI collaboration for pulmonary nodule segmentation

Medical expert annotators are scarce, and blind reliance on artificial intelligence (AI) can be misleading, motivating approaches in which humans, particularly junior medical trainees or even non-medical personnel, collaborate with AI to achieve robust medical segmentation. Although the Segment Anything Model (SAM) shows promise for general-purpose image segmentation, its performance in human-AI collaboration for specialized medical tasks has not been thoroughly evaluated. Here we present Hi-Seg, a human-in-the-loop segmentation framework for pulmonary nodules built on SAM. Humans iteratively refine prompts through trial-and-error learning and semantic reasoning, progressively guiding SAM toward higher-quality masks. Using chest CT scans from 1,179 patients across 12 centers, we conducted the first large-scale external validation of collaborative human-SAM segmentation. Across all annotator groups, Hi-Seg achieved a mean Dice score of almost 85%, outperforming five state-of-the-art deep learning models by 10-22% and 13 SAM variants by 1-29%. Hi-Seg improved segmentation accuracy while reducing annotation time for medical annotators, and briefly trained non-medical annotators achieved performance comparable to that of the junior medical student. These findings suggest that human-in-the-loop segmentation can reduce clinician workload, enable scalable crowdsourced annotation, and transform clinical workflows by facilitating the safe and efficient integration of foundation models into routine clinical practice.
Jun 17, 2026cs.CV

Scaling Generative Foundation Models for Chest Radiography with Rectified Flow Transformers

We introduce the first generative foundation model for chest radiograph synthesis trained from scratch at the billion-parameter scale. Existing radiographic AI models often suffer from poor generalisation across patient subpopulations, institutions, and acquisition settings, resulting in limited real-world clinical utility. Controlled, high-fidelity synthesis of chest radiographs is a promising path toward diversifying clinical datasets and evaluating the robustness of diagnostic models. Therefore, we present the largest specialist generative foundation model for chest radiographs to date, with over 1.3B parameters, trained for 1.6T tokens on a curated, heterogeneous dataset comprising 1.2M radiographs and clinical expert-guided metadata. Our model supports controllable radiograph generation and editing across multiple demographic subgroups, acquisition views, and a dozen pathologies. Moreover, we significantly advance the state of the art in radiograph synthesis fidelity, producing images that are indistinguishable from real radiographs to clinical experts.
Jun 17, 2026cs.CV

PEFT-MedSAM: Efficient Fine-Tuning of Medical Foundation Models for Explainable Skin Lesion Segmentation

Automated segmentation of skin lesions using deep learning models for dermoscopic images can be very helpful in finding melanomas earlier than they would normally be detected. However, most deep learning methods available do not perform well. The aim of this paper is to present a parameter-efficient fine-tuning method called PEFT-MedSAM for adapting the Medical Segment Anything Model (MedSAM) to automatically segment dermoscopic skin lesions. The PEFT-MedSAM method uses only the lightweight mask decoder for training the model while keeping the pre-trained image encoder and prompt encoder frozen. The experiments performed on the ISIC 2018 benchmark dataset shows that PEFT-MedSAM obtains a dice coefficient of .9411 and an intersection over union value of .8918 when compared to both a fully trained U-Net baseline (.8715 dice coefficient) and zero-shot MedSAM inference (.8997 dice coefficient). The external validation of the model using PH2 dataset shows .9467 dice coefficient with +/- .0310 standard deviation. Supportive evidence for these claims include a p-value less than .0001 for Wilcoxon signed rank tests comparing the two datasets and bootstrap-estimated 95% confidence intervals of [.9364,.9447] that represent the estimated range of possible values for the average dice coefficient obtained by repeating the test. To increase clinical trustworthiness, we used Grad-CAM explainability along with a pointing game based evaluation methodology to evaluate the CNN baseline model on the validation set. The results showed that we had an accuracy rate of 98.27% on the validation set of 519 images and confirmed that the model classified regions containing skin lesions.
Jun 14, 2026cs.CV

Mutual Distillation of Dual-Foundation Models for Semi-Supervised PET/CT Segmentation

Organ segmentation from PET/CT is critical for quantitative analysis and radiotherapy planning in oncology. To ease the high annotation cost of PET/CT segmentation, semi-supervised learning (SSL) provides a practical and effective solution for developing deep models with limited labeled data. Recent developments in visual foundation models have demonstrated remarkable adaptability with improved efficiency. In this work, we propose a mutual distillation framework that seamlessly exploits both structural and functional foundation models, which act as modality-specific generalists for distilling knowledge from structural CT and metabolic PET imaging. By bridging the gap between the task-specific precision of student models and the segmentation priors of generalist foundation models, we propose \textbf{MuDuo}, a mutual distillation framework that synergistically leverages SAM-Med3D for CT and SegAnyPET for PET to distill their knowledge into a lightweight student network. Our approach eliminates the need for manual prompts while maximizing the utility of unlabeled data for automatic segmentation, achieving state-of-the-art performance on the AutoPET dataset with only 5 labeled cases. Our source code is available at https://github.com/Wu-beining/MuDuo.
Jun 13, 2026cs.CV

EyeMVP: OCT-Informed Fundus Representation Learning via Paired CFP--OCT Pretraining

Color fundus photography (CFP) is the mainstay of large-scale retinal screening, but its diagnostic capacity is limited by the lack of depth-resolved structure, which optical coherence tomography (OCT) provides yet is less accessible at population scale. We present EyeMVP, a cross-modal retinal foundation model that uses paired CFP--OCT pretraining to learn OCT-informed CFP representations while requiring only CFP at inference. Pretrained on 674,893 same-eye same-day CFP--OCT triples from 112,642 patients across eight hospitals, EyeMVP uses cross-modal masked reconstruction to enrich CFP features with OCT-associated supervision, and combines source-constrained cross-attention with CFP-derived structural masks to accommodate the non-aligned geometry of en-face CFP and cross-sectional OCT. Across 15 dataset-level settings spanning classification and segmentation, under both full-data and few-shot regimes, EyeMVP performs on par with or better than representative retinal foundation models, with consistent gains on macular and optic-nerve tasks; it attains AUROCs of 0.923 for macular edema and 0.867 for myopic macular schisis, two conditions poorly resolved in CFP. In an exploratory reader study, EyeMVP surpasses junior and intermediate ophthalmologists but not seniors on macular edema, while exceeding all groups on myopic macular schisis. These results indicate that cross-modal reconstruction can enrich CFP representations with OCT-associated supervision, offering a practical route to stronger CFP-based screening.
Jun 12, 2026cs.CV

Learning Sparse Latent Predictive Foundation Model for Multimodal Neuroimaging

Brain MRIs are routinely acquired as multiple complementary sequences with unique contrast weighting, including T1-weighed imaging (T1w) anatomic and fluid-sensitive T2-weighted (T2w) contrasts. However, methods for learning unified representations across the multitude of MRI contrast mechanisms at health-system scale are lacking. In this study, we introduce Neuro-JEPA, a sparse multimodal neuroimaging foundation model that combines a latent predictive objective with a Mixture-of-Experts architecture to encode brain MRI across core T1w, T2w, and fluid-suppressed FLAIR imaging (FLAIR). We further provide a systematic methodological study of architectural, masking, objective, and sparsity design choices beneficial for robust neuroimaging multimodal representation learning. Neuro-JEPA was pretrained on 1,551,862 scans from 428,647 studies after modality-specific preprocessing with data curation across three core structural brain MRI sequences. We evaluated the learned representations across clinical and research settings, including 25 tasks from three health systems: NYU Langone, NYU Long Island, and Massachusetts General Hospital, and 22 tasks from 12 public datasets, covering unimodal, multimodal and cross-domain evaluation configurations. Across these benchmarks, existing neuroimaging foundation models showed inconsistent gains over a simple convolutional neural network (CNN) baseline, whereas Neuro-JEPA achieved stronger and more consistent performance across all evaluated settings. These results establish a scalable methodological framework for multimodal neuroimaging representation learning and highlight the need for foundation model evaluation protocols that include simple baselines, clinically heterogeneous cohorts and controlled multimodal comparisons.