Medical Imaging Foundation Models
Momentum
24 papers in the last four weeks, up 167% on the four weeks before. 0.2% of all new papers.
Latest papers 150
Accurate nuclei instance segmentation is essential for quantitative renal pathology, yet general-purpose models often struggle with low contrast, dense nuclei, complex morphology, and strong background staining. In this work, we extended a human-in-the-loop framework by combining 5,901 foundation-model-generated pseudo-labels from well-segmented cases (Easy), 860 newly expert-annotated unresolved challenging cases (Medium), and 198 expert-annotated consensus failure cases (Hard). These annotations, spanning different levels of segmentation difficulty, enabled the systematic evaluation of seven single-source and mixed-source fine-tuning strategies across nine cell segmentation model configurations. Fine-tuning improved all models, with Medium data included in seven of the nine best-performing strategies. LSP-DETR achieved the highest F1 score of 0.8725 with Hard-only fine-tuning, while StarDist showed the largest improvement, increasing from 0.7380 to 0.8332 with Medium-only fine-tuning. These findings show that annotations spanning multiple difficulty levels support effective model adaptation, although the optimal annotation composition remains model dependent.
EchoDino: A pediatric foundation model for transferable echocardiographic analysis across the lifespan
Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, localized structures and dynamic cardiac motion. Machine-learning models have automated individual tasks, but they are typically built for a single purpose and depend on expensively labeled datasets - a barrier particularly acute in pediatric care, where data are scarce and anatomy changes with age. Here we present EchoDino, a self-supervised foundation model for echocardiography, created by adapting the DINOv3 framework to 3.7 million frames from 1.7 million unlabeled pediatric echocardiography videos. With its encoder frozen, EchoDino produces representations that capture global context, local anatomy, and dense spatial detail. We introduce Motion-biased Entropy Maximization Sampling (MEMS) to select the most informative frames for video-level analysis. Across nine pediatric and adult datasets, EchoDino outperformed strong baseline models, raising view-classification accuracy from 0.609 to 0.889 and the area under the receiver operating characteristic curve for structural-heart-disease detection from 0.811 to 0.872, while also cutting age-estimation error from 3.857 to 1.389 years, achieving the best segmentation accuracy and lowering ejection-fraction errors. By generalizing from label-free pediatric data to adult echocardiography, EchoDino offers a versatile foundation for cardiac image analysis across the lifespan.
From Image Latent Space to Fuzzy Rules: Interpretable Analysis of Gastrointestinal Foundation Model
Foundation models pretrained on large-scale datasets demonstrate strong transferability to medical imaging tasks. However, understanding how their latent representations encode clinically relevant information remains an open challenge in safety-critical domains. This study proposes a prototype-based fuzzy-rule framework that interprets the patch-level features produced by the inner layers of pretrained foundation models, without any fine-tuning. Class-specific prototypes are learned by clustering in the feature space, yielding compact visual patterns. Patch features are then expressed as prototype similarities and classified by fuzzy rules with linguistic IF-THEN conditions that are human readable. The framework is applied across the final two blocks of ViT-S/16 backbones pretrained on ImageNet-1K and GastroNet-5M, and benchmarked against k-nearest neighbours, kernel SVM, and linear probing under identical frozen features, on wireless capsule endoscopy classification, gastrointestinal endoscopy classification, and colonic polyp segmentation. The experimental analysis shows that the proposed method, without backbone fine-tuning, reaches accuracy comparable to these black-box classifiers, and that domain-specific pretraining yields features that are both discriminative and symbolically compressible. Because the resulting rules are extracted from real data and expressed in interpretable terms, they are further used as an instrument to investigate synthetic medical images, providing a human-readable account of which real prototypes and rules a generator reproduces or fails to reproduce, localising where a synthetic image departs from real tissue rather than summarising it with a single score. The framework thus offers a transparent, depth-resolved view of how foundation models organise clinically relevant structure, together with a practical downstream use of the extracted rules.
Med-RADIO: Reducing All Medical Domains Into One via Multi-Teacher Distillation
The rapid expansion of large-scale medical datasets and computational resources has driven significant progress in medical foundation models. Given the inherent heterogeneity of medical imaging modalities, current research mainly follows two paths: specialized models optimized for specific modalities, and generalist models designed to handle multiple modalities. However, medical generalist models suffer from both insufficient training data scale relative to natural image generalists and inadequate domain-specific depth relative to medical specialists. Empirically, generalist models establish a cross-modality performance baseline, while specialists define the performance ceiling within their respective domains. To elevate this baseline toward these ceilings, we propose Med-RADIO, a medical multi-teacher distillation framework that Reduces All Domains Into One by compressing complementary expertise from multiple domain-specific teachers into a unified medical vision foundation model. Our method curates both generalist and specialist teachers, allocates modality-aligned distillation streams to reorganize generalist pretraining data so it matches specialist domains, and uses a balanced loss to prevent any single teacher from dominating the distillation process. On internal and external classification benchmarks spanning five modalities, Med-RADIO improves over strong medical generalists under linear probing and remains competitive with representative specialists on most evaluated modalities. Code is available at https://github.com/CAIR-HKISI/Med-RADIO.
Flattening the Connectome Spectrum: A Spectral Filter for FC Induces a Pretraining Target for fMRI Encoders
Self-supervised pretraining reshaped prediction in language and vision, and brain foundation models (BFMs) inherited its promise. Representations learned from large unlabelled corpora should capture individual functional dynamics and generalise across cohorts. However, kernel ridge regression (KRR) fitted on functional connectivity (FC) matrices still predicts individual phenotypes more accurately than any BFM we tested. In this paper, we show that KRR is weighted by the eigenvalues of the FC which are miscalibrated for phenotype prediction. We apply an efficient spectral filter to recalibrate the eigenvalues of each subject's FC matrix, enabling the model to exploit more inter-individual variance. Across the 5 datasets, 11 parcellations and 6 prediction targets we tested, we match or exceed the KRR baseline. Based on this finding, we then pretrain a small encoder model on about 4,000 hours of fMRI from 162 open datasets, whereby we align the pairwise similarities between the embeddings of recording snippets with those between the recalibrated connectomes. Our model performs on par with the best of the 6 published BFMs we tested while having an order of magnitude fewer parameters. Our encoder performs better than FC on short scans and in smaller cohorts, especially in fingerprinting. We release the pretrained model weights, the code and the pretraining data, preprocessed and parcellated.
TomoTransformer: Towards a Foundation Model for CT Reconstruction
Supervised deep learning has advanced sparse-view tomographic reconstruction. However, conventional models, which typically map filtered back-projection (FBP) images or sinograms to clean reconstructions, are brittle under distribution shifts. Because they require retraining whenever projection counts and angles, detector resolutions, or data distributions change, their deployment in real-world applications remains limited. To address this, we introduce TomoTransformer, a transformer-based architecture that treats each \textit{local} filtered projection as an individual token and predicts missing views via self-attention. Crucially, TomoTransformer operates in a \emph{back-projection space} that separates projections across spatial locations, making view interpolation geometrically well-posed and invariant to detector size. This design yields a single foundation model that can process any number of input projections, at arbitrary angular locations and detector dimensions, and query any number of target angles without retraining. Trained on a large-scale dataset spanning diverse medical CT anatomies and natural images, TomoTransformer generalizes effectively across anatomies, materials, and resolutions. Extensive evaluations on several benchmark sparse-view datasets show that TomoTransformer significantly outperforms concurrent multi-purpose models like ViewTrans and matches or exceeds strong protocol-specific baselines, while remaining fully agnostic to the number of input and target projections. Furthermore, the model demonstrates robust zero-shot generalization on real experimental nanoscale brain data collected from an X-ray synchrotron, showcasing its practical utility for real-world applications.
Reduce, Then Encode: Multiscale Volumetric Reduction for 2D Foundation Models in Brain MRI
Pretrained 2D foundation models offer a practical alternative to dedicated 3D pretraining for brain structural magnetic resonance imaging (sMRI), but their use on volumetric data requires bridging the mismatch between a 2D encoder and a 3D volume input. Existing methods typically encode slices independently and integrate their features afterwards. We introduce Multiscale Volumetric Reduction (MVR), a reduce-then-encode approach that compresses each anatomical view from (D) slices into (M << D) complementary 2D components before foundation-model encoding. MVR combines an uncentered-PCA base component derived from the original through-plane intensities with residual detail components constructed from multiscale spatial descriptors. The reduction is estimated from the training volumes without diagnostic labels or gradient-based optimization and remains fixed thereafter. The resulting components are independently processed by a shared frozen 2D foundation model and concatenated for linear probing. Under this frozen-encoder setting, MVR achieves strong overall performance across ADNI, OASIS, and ABIDE relative to the evaluated 2D-to-3D adaptation methods and simple input-reduction baselines, while also generalizing strongly from ADNI to AIBL.
Natural Image Autoencoder-Based fMRI Representations for Trait and State Prediction
Foundation models pre-trained on large-scale fMRI datasets have shown strong downstream performance, but at substantial data and computation cost. To investigate how much fMRI-specific pre-training is actually needed for such performance, we introduce FReD, which derives fMRI representations from a frozen Deep Compression AutoEncoder (DCAE) pre-trained exclusively on natural images and pairs them with a task specific readout. For trait prediction, FReD summarizes frame-wise representations by their temporal mean and log-standard deviation and applies linear probing, with late fusion across two normalization schemes. For state prediction, it represents each frame as a single token and models temporal dependencies with a shallow Transformer. Across four resting-state datasets spanning six trait-prediction targets, linear probes on frozen DCAE features generally outperform those on fMRI foundation model representations and remain competitive with fully fine-tuned fMRI foundation models. On three task-fMRI state-prediction tasks, a temporal readout on DCAE features performs comparably to the strongest foundation models evaluated. A Gaussian injection analysis further shows that localized signal changes are recovered more accurately from the frozen DCAE features than from the evaluated foundation-model representations. Together, these results show that strong performance on current fMRI benchmarks is possible without fMRI-specific representation pre-training, making frozen natural-image features as a useful baseline for assessing its added value.
UltraBench 2: Towards Robust Evaluation of Vision Foundation Models on Ultrasound
Benchmarking is an increasingly critical part of research in machine learning and the domains where it is applied, including healthcare. Yet, despite the steady development of new ultrasound foundation models in recent years, the development of well-designed benchmarks to evaluate them has lagged behind. This deficiency has led to fragmented and inconsistent evaluations of competing models, making it difficult to measure progress. To address this issue, we introduce UltraBench 2, a comprehensive benchmark with wide anatomical and task coverage, and a focus on standardization, reproducibility, and ease-of-use. Using this benchmark, we compare existing vision foundation models for ultrasound image analysis. Our analyses demonstrate that ultrasound-specific pretraining still leads on classification, but that state-of-the-art general-purpose models have drawn level on segmentation.
A generalizable structural brain MRI foundation model built through dual-priority federated pretraining
Foundation models hold promise for generalizable analysis of structural brain magnetic resonance imaging (MRI) across development, aging and disease. However, existing models are typically built through centralized pretraining on pooled data, despite privacy and governance constraints. Such pooling optimization can overemphasize cohort size and overlook complementary information from smaller, specialized cohorts. Here we present BrainFedFM, a structural brain MRI foundation model federatively pretrained on 164,707 three-dimensional scans drawn from diverse real-world data distributions and organized across 42 federated sites. BrainFedFM uses dual-priority federated pretraining, coupling spatial-priority masking at each site with site-priority aggregation at the server to emphasize informative anatomical regions locally and prioritize site contributions globally. Across 20 downstream datasets spanning 17 classification, regression and segmentation tasks, BrainFedFM achieved the state-of-the-art performance (mean rank 1.68, 50% gain) across seven models, including four centralized foundation models, while showing particularly consistent advantages in classification and regression and robustness across underrepresented populations. These findings demonstrate the generalizability of BrainFedFM and highlight federated pretraining as a practical strategy for developing neuroimaging foundation models from distributed data without pooling raw images.
A Scaling Study for fMRI Foundation Models
Scaling laws have guided large-model development in computer vision and natural language processing, but the relationships among data, model size, and compute remain unclear for functional magnetic resonance imaging (fMRI) foundation models. Here, we conduct a controlled empirical study using pretraining data from more than 200 source datasets and over 10,000 GPU-hours of experiments. Holding the pretraining framework and downstream protocol fixed, we vary pretraining data size, model size, and training duration. Downstream performance generally improves with compute, yet models using similar compute can perform substantially differently. Additional pretraining data bring larger gains at larger model sizes, suggesting that data and model size should be scaled together. At matched compute, increasing pretraining data benefits more tasks than increasing model size, although the pattern varies across tasks. We then use in-distribution (ID) downstream performance to select the combination of pretraining data size, model size, and training duration at two fixed compute budgets. The resulting models are locked before out-of-distribution (OOD) evaluation. They achieve the highest average performance across the evaluated OOD tasks among the compared fMRI foundation models while using less pretraining compute. Overall, our results show that compute alone does not characterize fMRI scaling: performance depends on how pretraining data, model size, and training duration are combined.
nnFoundation: 3D Foundation Models for Radiology
Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.
Foundation model embeddings capture pre-diagnostic changes on screening mammograms
Foundation model embeddings of screening mammograms may encode pre-diagnostic tissue change without task-specific adaptation. We tested whether embeddings move faster along a data-derived "cancer direction" in women later biopsied for cancer than in matched screen-negative controls, and whether this depends on pretraining domain. We studied 1,773 biopsied women (785 malignant, 988 biopsy-negative) and 1,773 matched controls, each with at least two annual screening exams before their index exam. An identical pipeline was applied to four 2D models: Mammo-CLIP (MC, out-of-distribution mammography), HOPPR (in-distribution mammography), MedImageInsight (MII, general medical imaging), and BiomedCLIP (biomedical vision-language pretraining on literature figures). Breast-level embeddings quantified longitudinal movement along the cancer direction. We compared cases and controls using a between-patient design with complementary mixed-effects analysis, and biopsied versus healthy contralateral breasts within patients. Under matched modality in MII embedding space, malignant cases drifted significantly faster than controls in the first two screening intervals preceding the index exam; biopsy-negative cases showed significance only in the first. MC differences were significant in the first interval for both biopsy groups. Within-patient comparisons showed a broadly similar pattern, with MC significance extending to the second interval in both groups and HOPPR showing significance at interval 1. BiomedCLIP showed no significant differences in either design or biopsy group. Overall, directional embedding velocity emerges as a property of clinically grounded rather than general biomedical pretraining, showing that foundation model embeddings can encode pre-diagnostic mammographic change without task-specific adaptation.
Radiomics-Conditioned Modulation of RenalCLIP Features for Clear Cell Renal Cell Carcinoma Classification
Radiomics provides quantitative descriptions of tumour appearance that may complement disease-specific foundation models in small labelled cohorts. We investigate this complementarity for computed tomography-based classification of clear cell renal cell carcinoma. Our framework uses radiomics to modulate RenalCLIP features through feature-wise linear modulation (FiLM), while retaining a direct radiomics contribution. Internal testing and external validation compare it with conventional fusion strategies and reference classifiers. The FiLM model achieves an area under the receiver operating characteristic curve (AUC) of 0.804 internally and 0.854 externally, with the highest mean AUC among the evaluated RenalCLIP fusion strategies in both cohorts. Pathway ablations examine the contributions of conditional modulation and the direct radiomics residual, while feature permutation highlights the role of tumour texture. These findings support radiomics as a useful complement to RenalCLIP in a small labelled cohort and identify FiLM as an effective approach to integrating their representations for robust renal tumour classification.
Complementary Roles of Radiomics and Foundation Representations in Renal Cell Carcinoma Classification: A Comparative Study of 2D and 3D CT Encodings
Accurate preoperative subtype classification of renal cell carcinoma (RCC) from contrast-enhanced computed tomography remains clinically challenging. Radiomics provides structured tumour descriptors, whereas foundation representations offer transferable image features. However, it remains unclear whether radiomics still adds value beyond pretrained representations, and how 2D and 3D MedVAE encoders compare in this setting. We compared handcrafted radiomics, 2D MedVAE, 3D MedVAE, and their fusion for binary clear-cell RCC versus non-clear-cell RCC classification on KiTS23 under a unified preprocessing pipeline. Concatenation, cross-attention, and gated fusion were evaluated as representative integration strategies, and radiomics feature importance was analysed to support decision-centric interpretability. Fusion consistently improved discrimination over image-only MedVAE branches. The best overall performance was achieved by 3D gated fusion, with an AUC of 82.7%, outperforming the best 2D fusion model (79.6%), the radiomics baseline (74.4%), and the single-modality MedVAE branches. Ablation analysis further showed clear gains of the full fusion model over both image-only and radiomics-only variants, indicating complementary contributions from radiomics and image representations. These findings suggest that radiomics remains relevant for RCC CT classification in the presence of foundation representations, and that its integration with MedVAE is more effective in the 3D setting. More broadly, the study supports a complementary role for radiomics and foundation representations in clinically meaningful imaging decision support.
Generating Chest X-Ray Counterfactuals by Specialising Foundation Image Models
Counterfactual image generation answers questions about how a subject would have looked under retrospective, hypothetical scenarios. Recent methods have improved perceptual quality, identity preservation and faithfulness to an underlying causal model, but their adoption in healthcare is limited by scarce annotated data, distribution shift between datasets, and mismatches between pretrained generative models and those required for counterfactual inference. We propose specialisation, a data and parameter-efficient framework for adapting pretrained, non-causal generative models into causal mechanisms under distribution shift. Based on this framework, we train a radiology counterfactual image generation model, called RadCF, using latent flow matching. We validate our approach on three chest X-ray datasets spanning different dataset shifts, data volumes, and counterfactual questions, associated with challenging, highly-localised interventions. Our results show that RadCF and specialisation improve counterfactual soundness over existing methods while being data and parameter efficient, and that the resulting counterfactuals can detect and mitigate shortcut learning in a downstream medical classifier. Code is available at https://github.com/GSK-AI/RadCF/.
Evaluating the Generalization of Neuroimaging Foundation Models on African Brain MRI
Neuroimaging foundation models pretrained on large, predominantly western cohorts are increasingly proposed as general-purpose backbones for brain MRI analysis. Yet, their ability to generalize to underrepresented clinical populations remains largely untested. We evaluate four recent foundation models (BrainIAC, Neuro-JEPA, NeuroVFM, and Primus) on a three-way diagnostic classification task (Control, Dementia, Parkinson's disease) using a cohort of 88 subjects from a Nigerian clinical brain MRI dataset, across four modality configurations (T1w, T2w, T1w+T2w, FLAIR), and compare against an end-to-end trained ViT3D baseline. The frozen backbones collapse to majority-class predictions, while Neuro-JEPA on FLAIR shows modest but still limited discrimination. In contrast, the end-to-end trained ViT3D achieves higher accuracy and MCC on every task (up to 53.4% accuracy, MCC=0.27) and is the only model with non-trivial recall. Our findings suggest that these frozen neuroimaging foundation models are insufficient for fine-grained diagnostic classification in small, non-western clinical cohorts, motivating parameter-efficient adaptation and broader multi-site external validation for equitable deployment in global health settings.
ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation
Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner Reporting with Integrated fOunda-tioN Model), the first clinically evaluated scanner-native end-to-end CMR foundation model. Pretrained on 12,896,733 CMR images from 9,258 studies, ORION-CMR performs sequence classification, ventricular function assessment, late gadolinium enhancement (LGE) detection, binary and multiclass disease classification, and local large language model-based report generation in approximately 90 seconds. The framework. was evaluated on public benchmarks and clinically validated in a multi-vendor cohort of 68 subjects with normal examinations, congenital heart disease, dilated cardiomyopathy, and myocardial infarction. ORION-CMR outperformed supervised baselines and the previously published CMR foundation model (CMR-FM), achieving state-of-the-art performance for LGE classification and scar segmentation. Clinical evaluation achieved an AUC of 0.96 for normal-versus abnormal classification and 0.88 for multiclass disease classification, while generated reports demonstrated 81.4% agreement with expert interpretation. These results demonstrate the feasibility of real-time scanner-native AI-assisted CMR analysis and automated report generation.
FreqDINO++: A Frequency-Guided Multi-Task Routing Vision Foundation Model for Universal Ultrasound Analysis
Ultrasound image analysis plays a crucial role in cancer screening and prenatal diagnosis, yet comprehensive assessment requires jointly addressing tasks such as lesion segmentation and benign-malignant classification. While recent vision foundation models have shown remarkable universal representations, unlocking their potential for ultrasound is bottlenecked by the considerable domain gap from natural images. Existing methods typically fine-tune heavy vision encoders for isolated tasks, incurring substantial computational overhead while overlooking the underlying commonalities across heterogeneous tasks. In this work, we propose FreqDINO++, a frequency-guided multi-task routing vision foundation model for universal ultrasound analysis. We first introduce a Multi-task Routing Adapter (MR-Adapter) to support parameter-efficient integration of task-common and task-specific knowledge, a Frequency-aware Feature Enhancer (F-Enhancer) is then designed to capture the rich multi-scale frequency characteristics of ultrasound images, and a Task-aligned Collaborative Decoder (TC-Decoder) is devised to promote collaboration between dense and global prediction tasks through global-local token interaction. Extensive experiments on large-scale multi-task and external single-task ultrasound benchmarks demonstrate that FreqDINO++ consistently outperforms strong baselines and recent foundation models across 27 diverse clinical task scenarios, while also showing promising generalization to unseen data. The code is at https://github.com/MingLang-FD/FreqDINO-Plus.
Mammography Foundation Models for Opportunistic Prediction of Major Adverse Cardiovascular Events
Cardiovascular disease (CVD) remains the leading cause of death among women, yet cardiovascular risk assessment often relies on clinical variables that may be missing, outdated, or unavailable in routine care. Screening mammography offers an opportunity for opportunistic cardiovascular risk stratification because it is routinely acquired and contains vascular features, including breast arterial calcifications (BAC), that are associated with cardiovascular risk and events. We evaluate whether mammography specific foundation models, originally pretrained for breast cancer-related tasks, can transfer to cardiovascular risk prediction without cardiovascular specific supervision or explicit BAC annotation. We constructed a 5-year major adverse cardiovascular event (MACE) cohort of 22,497 women linked to electronic health record outcomes, including 500 events (2.22% prevalence). The foundation models achieved AUROCs of 0.823 and 0.822 substantially exceeding an age-only model (AUROC 0.765), despite using only the screening mammogram as input, with no clinical variables. Both foundation models evaluated assigned substantially higher predicted risk to patients with radiologist-documented BAC, despite BAC never being used as a training label, and showed activation patterns consistent with vascular findings. Together, these findings suggest that mammography foundation models can recover clinically relevant cardiovascular risk information directly from mammographic pixels and suggest that screening mammography may provide an opportunistic source of cardiovascular risk information to complement conventional clinical assessment without additional imaging. Code is available in https://github.com/PauFeld/MammoCVD
Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings
Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13% versus 18--42%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code.
woma: a real-time foundation model and its fine-tuned models for endoscopy
woma is a real-time foundation model for gastrointestinal endoscopy: a network trained without labels on about a million endoscopy frames, from which task models are fine-tuned. We contribute a systematic design for production. Requirements and pass marks were fixed before any run, eight candidates screened under pre-registered rules, self-supervised training taken to a stopping rule, then fine-tuning and deployment optimisation, all on one self-contained library, numbat. We also contribute woma itself with two fine-tuned models, every outcome reported met or missed. Our colonoscopy model finds and outlines polyps, names which colon segment is in view, suggests polyp type and grades bowel preparation. Our gastroscopy model names a station out of 22 protocol sites, flags and outlines lesions, and names one of seven findings. Every number was read on data never seen in training, and shipped weights were chosen on that record. In colonoscopy, 96% of polyps in a six-hospital PolypGen set are found at precision >=0.85, and 19 of 19 polyps across fifteen full REAL-Colon videos at 1.6 false alarms per procedure. In gastroscopy, landmark region is named correctly on 92% of frames from unseen patients, and 37 of 39 held-out neoplasia frames are flagged at specificity 0.91. On one workstation GPU every task runs over 1080p video at about 100 frames per second, faster than PyTorch, ONNX Runtime and TensorRT in all four precision regimes tested. TensorRT comes closest: one pass of our foundation model takes it 3 to 27% longer than ours, and we deliver 6 to 31% more frames per second from frame to results. A second build links no vendor library at all -- our own kernels over Vulkan -- so a site deploys two files and needs no toolkit, no cuDNN and no framework; in f32 it beats the CUDA build on the same card.
SV-Cine: Diagnosis-Conditioned Segmentation of Single Ventricle Physiology via Generative Data Augmentation
Single Ventricle Physiology (SVP) is a rare subtype of congenital heart disease characterized by the presence of a single functional cardiac ventricle with atypical anatomic configurations that challenge conventional image segmentation approaches. The scarcity of clinical data and the morphological diversity across SVP subtypes make the development of robust segmentation methods particularly difficult. To address these limitations, we propose a cardiac MRI segmentation framework focused on ventricular chambers and myocardium segmentation tailored for SVP. First, we introduce a data augmentation pipeline that generates synthetic 3D cardiac meshes using SDF4CHD and corresponding synthetic cardiac MRI through generative modeling. Second, we introduce SV-Cine, a diagnosis-conditioned adaptation of the foundation model CineMA that incorporates patient-level diagnostic information through Feature-wise Linear Modulation layers, enabling diagnosis-aware feature adaptation during segmentation. We evaluated the framework on an internal cohort with varying SVP subtypes. SV-Cine achieved median Dice scores of 0.89 (IQR: 0.80--0.91) for the left ventricle and 0.72 (IQR: 0.54--0.84) for the right ventricle, outperforming the strongest baseline, nnU-Net, by 0.39 Dice points on right ventricle segmentation. It also yields a median ejection fraction error of 5.55 percentage points (IQR: 3.41--7.69) for the dominant ventricle. Compared with the internal cohort, LV and myocardium segmentation performance was lower for the external cohort; whereas RV Dice scores were comparable for both cohorts. Our findings suggest that a pretrained foundation model can be adapted for highly specialized downstream tasks through usage of diagnosis priors while leveraging anatomic knowledge learned from large-scale MRI datasets during pretraining.
DINO-Med: A Unified Patch-Based Adaptation Framework for Multi-Modal Medical Image Analysis Applied to Liver Fibrosis Staging
Adapting natural-image foundation models like DINOv3 to multi-modal medical imaging is challenging due to the significant domain gap between natural color images and multi-channel medical scans. We present a unified, patch-based framework that processes raw multimodal imaging through training-free registration, automated localization, and mask-filtered patch extraction. This architecture culminates in a hierarchical strategy that aggregates patch-level insights into subject-level diagnostics. Using liver fibrosis staging as a case study, we evaluate four patch-level feature representations: handcrafted Radiomics features, learned ResNet features, pre-trained foundation model SAM-Med2D features, and frozen DINOv3 features. To ensure a controlled comparison, all models utilize the same lightweight MLP head and are evaluated across both rigid and deformable registration settings. Our training protocol focuses on mild fibrosis (S1) and cirrhosis (S4) classes only, enabling a single classifier to address both substantial fibrosis detection and cirrhosis staging. Evaluated via 10 random train (90%)/ test (10%) splits on 360 subjects from the CARE 2025 Liver Track 4 cohort, our DINOv3-based framework significantly outperforms all baselines, achieving the best classification accuracy of 78.4% for S1 and 75.8% for S4.
BrainTaskonomy: Learning How to Pretrain and What to Transfer in fMRI Foundation Models
fMRI foundation models increasingly aggregate heterogeneous data across brain states, cohorts, and acquisition settings, yet pretraining domains are commonly treated as a flat mixture and downstream tasks are adapted independently. We study whether measured learning relations can organize both stages without modifying the backbone. During pretraining, a lightweight Brain-DiT proxy estimates difficulty and directed facilitation across ten fMRI domains, yielding a priority-guided cumulative domain curriculum combined with high-to-low-noise timestep scheduling and joint consolidation. During adaptation, controlled first- and higher-order transfer across fifteen tasks constructs a directed taskonomy, from which budgeted integer programming (BIP) selects directly supervised source tasks and target-specific routes. The joint priority-domain and high-to-low-timestep curriculum reduces v-NMSE, PSD-NMSE, and FC-MSE by 6.5%, 16.3%, and 10.5%, respectively, relative to uniform sampling over both dimensions, and shows strong downstream performance across six in- and out-of-domain tasks. The taskonomy reveals asymmetric, target-dependent transfer, while exploratory sealed-test evaluation shows larger descriptive gains for BIP policies when higher-order route spaces are available than for matched random controls. Together, these findings support organizing fMRI pretraining and adaptation by measured learning relations rather than treating domains and tasks as independent flat sets.
Disease Burden over Skin Tone: Decomposing the Dermatology-AI Generalization Gap
Dermatology artificial intelligence (AI) models are predominantly trained on light-skinned, cancer-focused image collections, yet they are increasingly proposed for deployment in resource-constrained settings where patients differ from training populations along two confounded axes: skin tone and disease distribution. We investigate whether poor generalization is primarily caused by skin-tone underrepresentation or disease-distribution shift. We evaluate a cancer-trained baseline (ResNet-50 fine-tuned on HAM10000 and ISIC 2019), two dermatology foundation models (DermLIP and MONET), and a general-purpose vision model (DINOv3) as frozen feature extractors. Models are evaluated on a tone-stratified disease-matched dataset (Diverse Dermatology Images, DDI) and a disease-shifted tone-diverse dataset (Skin Condition Image Network, SCIN). Our results show that disease-distribution shift contributes more than skin tone in the evaluated settings. The cancer baseline decreases from 0.62 to 0.21 balanced accuracy when transferred to unfamiliar clinical conditions, while the within-disease skin-tone gap is smaller (0.10-0.18) and inconsistent. Label-free representation analysis shows that this failure reflects a representational limitation rather than only missing output labels: cancer-specialized features poorly cluster unfamiliar conditions (kNN purity lift +0.06 over chance), whereas dermatology-pretrained features retain stronger transferable structure (+0.23). Finally, we show that representation quality predicts recoverable performance under lightweight adaptation. Starting from dermatology foundation models, approximately ten labeled examples per clinical category recover most attainable performance. We release the evaluation protocol and code to support reproducible auditing of dermatology AI generalization.
CMRVision: A Foundation Model for Cardiac MR Image Analysis
Cardiac magnetic resonance (CMR) imaging provides complementary information on cardiac anatomy, function, and tissue characterization across multiple sequences and views. In this work, we investigate foundation model pretraining for 2D CMR and introduce CMRVision, a CMR-specific foundation model trained using DINOv3-style self-supervised learning on a multi-center, multi-sequence cohort of 36 million CMR images. We systematically evaluate architectural and training design choices for domain-specific pretraining. CMRVision is evaluated on two downstream tasks: multi-task segmentation across cine, late gadolinium enhancement (LGE), and mapping sequences, and cine view classification. Our experiments show that CMR-specific pretraining, smaller patch sizes, and patch-level objectives consistently improve downstream performance. Across a multi-task segmentation benchmark, CMRVision achieved the strongest overall performance, outperforming prior natural-image (NI), medical-image, supervised, and CMR foundation model baselines. Improvements were modest but consistent across structures and sequences, with Dice scores ranging from 0.940-0.967 for LV and 0.855-0.905 for myocardium, and reaching 0.929 for RV, 0.920 for LA, and 0.931 for RA. The largest gains were observed for myocardium segmentation in LGE and mapping images. In a zero-shot segmentation task on unseen LGE long-axis views, the model achieved an average Dice score of 0.692, demonstrating cross-view generalization. For cine view classification, CMRVision achieved the highest average accuracy (0.906), compared to prior methods reported in the literature. These results highlight the potential of CMRVision to support robust and generalizable cardiac MRI analysis across multiple sequences and views.
MR-JEPA: A General Purpose Video Foundation Model for Cardiac MRI
Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.
Uncertainty of Vision Medical Foundation Models
Accurate uncertainty estimation is essential for machine learning systems de- ployed in high-stakes domains such as medicine. Traditional approaches primarily rely on probability outputs from trained models (point predictions), which provide no formal guarantees on prediction coverage and often require additional calibra- tion techniques to improve reliability. In contrast, conformal prediction (region prediction) offers a principled alternative by generating prediction sets with finite- sample validity guarantees, ensuring that the ground truth is contained within the set at a specified confidence level. In this study, we explore the impact of pre-training approach, dataset scale and domain on both point and region-level uncertainty quantification, by studying domain-specific vision medical foundation models vs. general domain vision foundation models. We conduct a comprehensive evaluation across foundation models trained on retinal, histopathological, and Chest X-Rays data, applying various calibration techniques. Our results demonstrate that (1) pre-training on higher-quality domain-specific datasets along with self-supervised learning leads to better-calibrated point predictions than general domain pre-training, (2) stan- dard re-calibration methods alone cannot fully mitigate uncertainty discrepancies across models trained on different data sources, (3) domain-specific foundation model can lead to more efficient conformal prediction. These findings highlight the importance of careful model selection and the inte- gration of both point and region prediction to enhance the reliability and trust- worthiness of medical AI systems. Our work underscores the need for a holistic approach to uncertainty quantification in recent development of medical vision foundation model, ensuring robust and interpretable AI-driven decision-making.
Subgroup performance analysis of adaptation strategies for chest X-ray foundation models
Foundation models are increasingly adapted for downstream medical imaging tasks, yet the influence of the chosen adaptation strategy on subgroup fairness remains poorly understood. We investigate how three parameter-efficient adaptation techniques, including linear heads on the raw CLS token, an MLP, and an attention-pooling module over multi-layer patch features, affect both pathology classification performance and subgroup disparities when applied to the frozen Rad-DINO chest X-ray encoder. Using MIMIC-CXR, we evaluate eight pathologies across race, sex, and imaging-view subgroups on a prevalence-preserving, demographically balanced test set, and additionally probe how strongly each adapter encodes protected attributes. We find that attention pooling achieves the strongest overall discriminative performance and encodes attributes, particularly race, most strongly, but that improved overall performance does not consistently reduce subgroup disparities. Notably, stronger attribute encoding did not correspond to larger disparities: early network layers encoded race most weakly yet produced the largest subgroup performance gaps. Exploring different attention-pooling layer combinations further revealed no consistent relationship between the layers pooled, attribute encoding strength, and subgroup fairness. Our results indicate that richer, more expressive representations can improve accuracy while leaving fairness implications task-dependent and unpredictable, which must be assessed directly and per-task rather than inferred from encoding strength or overall performance alone.
Evaluation of Clinically Steerable Retinal Image Generation from Foundation Model Latent Spaces
Medical foundation models learn latent representations of clinically meaningful phenotypes, yet their ability to support controllable image generation remains largely unexplored. We evaluate four retinal foundation models within the representation tokenizer framework and examine whether demographic and clinical information encoded in latent representations from foundation models is preserved during synthetic image generation. We show that generated representations and images faithfully inherit phenotype information when evaluated within their originating foundation models, consistently outperforming conventional latent diffusion on multiple downstream prediction tasks. However, these gains largely disappear when evaluated using classifiers trained on real images, revealing a previously uncharacterised synthetic-to-real representation gap. These findings demonstrate that foundation-model latent spaces provide a powerful substrate for controllable retinal synthesis while highlighting the need to better align synthetic representations with real-image distributions.
Mr3D-VL: A generalist vision language foundation model for Multiparametric 3D Magnetic Resonance Imaging
Multi-parametric magnetic resonance imaging (mpMRI) is a cornerstone for brain tumor diagnosis and treatment, yet current AI models face critical limitations: their lack of natural language interaction and interpretability impedes spatial information integration and cross-modal reasoning required clinically. Key challenges arise from significant physical meaning differences across modalities, spatial misalignment due to scan intervals, and the need for complex multi-feature interpretation in tasks like glioma grading. While visual-language models (VLMs) show promise in cross-modal understanding, existing methods focus mainly on 2D image modeling, neglecting direct perception of 3D volumetric space. Although 3D VLMs have been proposed for report generation and feature alignment in 3D CT imaging, mpMRI applications demand collaborative inference across multiple imaging modalities-a requirement unmet by current solutions. To address this, we introduce Mr3D-VL, a dedicated visual-language foundation model for multi-parametric 3D MRI. With 4 billion parameters, it employs an unsupervised pre-trained shared 3D encoder and 4D rotational positional embedding for dual modality-spatial integration. Its cross-modal projection layer uses a multi-resolution feature implantation strategy to enhance feature perception across resolutions. Experimental results show significant improvements over existing 4B/7B/30B domain-specific and general-purpose models in text generation tasks, achieving a BERTScore of 0.856 for report generation, with question-answering accuracy at 0.713 and multiple-choice accuracy at 0.912.
GenFAR: A generalized representation of brain structure, derived from 49,246 multi-cohort MRIs via deep learning
Deep learning models for neuroimaging have largely been developed for individual tasks, limiting knowledge transfer across applications. Here we introduce GenFAR, a modular deep learning framework that learns general, clinically informed features from brain MRIs. We trained this modular architecture on 49,246 individuals across 11 cohorts, using 17 diverse classification and regression tasks spanning cognition, clinical, diagnosis, demographics, and biomarkers. This yields aggregated, focused feature sets that capture rich, clinically- and biologically-relevant brain representations. We developed a sequential learning approach where tasks progressively build on previously learned representations. Through an analysis of 5,000 task sequences, we identified an optimal sequence length of six tasks and introduced a Donor Score metric to quantify each task's contribution to downstream performance. This analysis revealed five consistently strong donor tasks (Age, AD/MCI, MMSE, Hypertension, Hyperlipidemia) that formed the base of our sequential model. We demonstrated the utility of our learned representation, in various tasks beyond those included in the training set, to serve as the foundation for specialized secondary predictors. We further showed that using the learned feature representation can substantially increase the sample efficiency of secondary deep learning training tasks and models, as well as improve their accuracy.
Frozen Brain-MRI Foundation Models Are Site Fingerprints
Frozen foundation-model (FM) embeddings are increasingly used as off-the-shelf brain-MRI representations, on the assumption that they capture anatomy. We audit what they actually encode and find that acquisition site is a large, intrinsic component of the representation. Across two independent cohorts (ABIDE-I, ABIDE-II), three frozen 3-D encoders (brain-pretrained, CT-pretrained, and randomly initialized), and every network depth, site is linearly decodable at roughly 0.9 balanced accuracy at deep layers, exceeding the decodability of every clinical or demographic variable (sex, age, autism diagnosis) at every layer. The effect is intrinsic rather than learned: a randomly initialized encoder is already a ~0.9 site classifier on both cohorts and across three architecture families (Swin, ViT, ResNet), and site is decodable at ~0.95 directly from the raw downsampled image with no encoder, so the fingerprint reflects low-level image statistics that any encoder preserves rather than a product of pretraining. Residualizing measured population covariates leaves site decodability essentially unchanged, indicating an acquisition- rather than population-driven effect. A nonlinear probe matches the linear one, so the fingerprint is fully linearly accessible. The site subspace is removable post hoc by iterative null-space projection or ComBat (site decodability 0.94 -> 0.07/0.00), and is a site-attribution concern for shared or federated embeddings; but for dense segmentation this removal is not free, because site and anatomy occupy an entangled linear subspace (a matched-rank random-direction projection is Dice-neutral, whereas removing the site subspace is destructive). We recommend site-audited use of frozen brain-MRI FMs and release an open audit toolkit.
A continually expandable foundation model for brain MRI
Brain magnetic resonance imaging (MRI) is central to neuroscience and clinical assessment, but models are commonly developed for individual diseases, populations or imaging protocols. Foundation models promise more general representations, yet they are usually pretrained once and can lose earlier capabilities when updated with new data. Here we show that Alcmaeon, a three-dimensional brain MRI foundation model pretrained without manual labels on more than 425,000 volumes and derived imaging maps, can be expanded sequentially across clinical domains. Alcmaeon combines volumetric encoding and latent diffusion generation with Graph-Blueprint Pruning (GBP), which protects network modules important to earlier domains while leaving the remaining capacity trainable. Across expansion from healthy ageing and neurodegeneration to developmental, psychiatric and tumour imaging, GBP showed less forgetting than sequential adaptation and elastic weight consolidation across voxel-level reconstruction measures, with its largest advantage after adaptation to tumour imaging. The blueprints provided an inspectable record of how model capacity was protected and reused. Representations from different model levels supported image synthesis, disease classification, survival modelling and postoperative prediction, although no single representation was optimal for every task. These findings provide a route towards brain MRI foundation models that can grow with emerging data while retaining earlier capabilities.
Distilling CT Foundation Models into Editable Concept Bottlenecks for Lung Nodule Malignancy Prediction
Foundation models provide transferable CT representations, but predictions based directly on these embeddings are difficult to interpret. We developed concept bottleneck models that map two frozen CT foundation-model representations to eight radiologist-defined pulmonary-nodule attributes and predict malignancy from the estimated concepts and nodule size. The models included CT-FM, a whole-CT self-supervised encoder using a 96^3-voxel nodule-centered patch, and FMCIB, a nodule-focused contrastive encoder using a 50-mm crop. Eight ridge-regression concept heads were trained on 2,610 LIDC-IDRI nodules. Malignancy models were trained on LUNA25 and evaluated on a held-out internal test set and the external DLCS cohort. Concept fidelity was assessed using five-fold cross-validated R^2, and malignancy discrimination was assessed using AUROC with 95% confidence intervals estimated by patient-grouped bootstrap resampling. Concept fidelity was modest but higher for FMCIB than CT-FM for subtlety (R2, 0.24 vs. 0.11), spiculation (0.17 vs. 0.08), texture (0.17 vs. 0.07), and lobulation (0.15 vs. 0.05). Internally, the CT-FM and FMCIB concept+size models achieved AUROCs of 0.86 (95% CI, 0.80-0.92) and 0.86 (0.79-0.92), respectively. Externally, AUROCs were 0.72 (0.68-0.75) and 0.73 (0.70-0.76), compared with 0.73 for nodule size alone and 0.60 and 0.67 for the corresponding embedding only probes. Additive predictions could be decomposed into feature-level contributions and modified through controlled concept interventions. Concept bottlenecks provided transparent malignancy predictions with discrimination similar to nodule size alone, while differences in concept fidelity suggest that concept recovery depends on the underlying foundation-model representation.
DINO-3DRA: Leveraging 2D Foundation Model Semantics for 3D Cerebral Aneurysm Segmentation
Accurate aneurysm segmentation in 3D rotational angiography (3DRA) is hindered by extreme class imbalance, morphological similarity to vessels, and absent large-scale 3D pretraining. 2D vision foundation models encode dense structural priors from 1.7 billion images, yet naïve slice-wise transfer fragments anatomical continuity and destabilises optimisation. We propose DINO-3DRA, a dual-path framework achieving effective cross-dimensional semantic transfer by injecting frozen DINOv3 features into a 3D U-Net backbone via Room-Lite spatial mixing and calibrated residual fusion. On multi-centre 3DRA data, DINO-3DRA achieves state-of-the-art aneurysm segmentation (Dice: 0.758; HD95: 2.75 mm; +13% over nnU-Net) with only 5.72M trainable parameters. Ablation studies confirm that gains arise from structured cross-dimensional transfer rather than loss design alone, with bridged foundation features improving anatomical continuity between aneurysms and parent vessels. Without fine-tuning on CADA and SHINY-ICARUS, DINO-3DRA eliminates all catastrophic failure cases observed in baseline architectures, demonstrating robust generalisation across heterogeneous imaging protocols.
Foundation Models Adaptation for Multi-View Multi-modal Cardiac MRI Segmentation and Direct Ejection Fraction Estimation
Foundation models have shown strong transferability in cardiac MRI (CMR), but their effectiveness for heterogeneous multi-view and multi-sequence CMR analysis remains unclear. In this work, we explore the effectiveness of fine-tuning and combining different CMR foundation models for the Universal Multi-Sequence, Multi-Center and Multi-View CMR Segmentation (CMR-Multi) Challenge. CineMA was fine-tuned for cine and late gadolinium enhancement (LGE) segmentation across short-axis and long-axis views. For direct left-ventricular ejection fraction (LVEF) estimation, we used two recent frozen CMR foundation models to extract embedding vectors that were then combined using attention-based multiple-instance learning for LVEF regression. In the challenge validation set, cine segmentation achieved Dice scores of 0.862, 0.883, and 0.902 for short-axis, two-chamber and four-chamber cine MRI, respectively. LGE segmentation achieved Dice scores between 0.621 and 0.846 across views. The direct LVEF regression model achieved an MAE of 4.96 percentage points and a Pearson correlation of 0.91. These results indicate that foundation models can be effectively adapted and combined for multi-view CMR analysis, while accurate LGE scar segmentation remains a challenging task.
A foundation-model approach to pediatric headache classification from rs-fMRI
Headache is the most common neurological disorder in children and substantially affects quality of life. We investigated whether resting-state functional MRI (rs-fMRI) can support pediatric headache classification using machine learning. We encoded rs-fMRI data using NeuroSTORM, a recent foundation model, and fine-tuned it to distinguish healthy controls from children with headache and subsequently classify headache subtypes. We compared NeuroSTORM with a standard neuroscience approach using functional-connectivity (FC) matrices derived from brain activity as predictors. Using 189 rs-fMRI scans from 110 individuals collected across two visits (prevalence of any headache: 74%), NeuroSTORM achieved an area under the receiver operating characteristic curve (AUROC) of 0.82 (95% CI, 0.82-0.82) and an area under the precision-recall curve (AUPRC) of 0.93 (95% CI, 0.93-0.94) for discriminating headache from non-headache. In contrast, models trained on FC matrices showed lower performance (AUROC, 0.67 [95% CI, 0.67-0.67]; AUPRC, 0.85 [95% CI, 0.85-0.85]). In multiclass classification of healthy controls, chronic migraine, and non-chronic headaches (e.g., post-viral headache, new daily persistent headache, post-traumatic headache), NeuroSTORM achieved a macro-AUROC of 0.69 (95% CI, 0.68-0.69). Results suggest that the approach can distinguish chronic migraine but has difficulty differentiating other headache subtypes from chronic migraine. Overall, under limited-data conditions, NeuroSTORM appears to capture latent rs-fMRI representations that transfer to headache-related tasks without relying on FC features. These findings provide proof of concept for fMRI-based prediction of pediatric headache and highlight potential future utility for subtype identification and individualized treatment strategies.
Do 3D Medical Foundation Models See Through MRI Artifacts? A Controlled Study of Representation Robustness
Self-supervised 3D medical foundation models are increasingly used as general-purpose feature extractors, yet their sensitivity to MRI artifacts remains poorly understood. We present a controlled evaluation of representation robustness across five pretrained 3D encoders spanning different architectures, objectives, pretraining domains, and dataset scales. Using BraTS-Africa cases with four MRI sequences, we generate seven frequency- and image-domain artifacts at five predefined corruption settings. Robustness is assessed using linear centered kernel alignment (CKA), RankMe, and UMAP, complemented by an independent segmentation-consistency analysis. We find that robustness is strongly model- and artifact-dependent. 3DINO exhibits the most consistently stable representations, while BrainIAC is highly sensitive to several corruptions; NeuroVFM, BrainFM, and Neuro-SimCLR show intermediate but distinct artifact-specific profiles. Across many conditions, CKA decreases substantially while RankMe remains comparatively stable, indicating that artifacts often distort representation geometry without causing dimensional collapse. Segmentation consistency also degrades under corruption, particularly for ghosting and Rician noise, but aligns only partially with representation-level robustness. These findings show that larger-scale or domain-specific pretraining alone does not guarantee artifact invariance and motivate explicit robustness evaluation before deploying 3D foundation models in heterogeneous MRI settings.
Big, Bright, or Invisible: A Frozen-Feature Benchmark of 3D CT Foundation Models
Routine CT interpretation is inherently comprehensive, capturing incidental findings across the entire scan volume. 3D CT foundation models could assist this process by providing generalizable representations of anatomy and pathology. To evaluate their diagnostic breadth, we benchmark ten frozen CT encoders across three cohorts of thoracic CT scans, including an unseen internal clinical dataset, using -nearest neighbors, zero-shot prompting, and linear probing. We find no universal state-of-the-art, with rankings fluctuating significantly depending on the evaluation context. While models combining fine-grained image tokenization with vision-language alignment generally perform best, a lightweight supervised encoder remains highly competitive, demonstrating that explicit labels can effectively substitute for scale. Crucially, rather than model architecture, we observe that the primary determinant of performance is a physical bottleneck: a finding's detectability scales with its contrast against surrounding tissue and its spatial extent. Through controlled within-organ comparisons, we empirically demonstrate that widespread or high-contrast abnormalities, such as devices and effusions, are reliably recovered. Conversely, small, low-contrast focal lesions remain a persistent challenge across all evaluated encoders. We attribute this to the inherent limitations of globally pooled embeddings, suggesting that accurately representing small, low-contrast structures will require region- or lesion-level pretraining.
Curia-MAE: Multi-Modal Multi-Anatomy MAE Pre-Training for 3D Medical Image Segmentation
Radiology foundation models learn transferable representations that can be adapted to new tasks by training only small layers on top of a frozen encoder. Dense prediction tasks such as 3D segmentation are, however, underrepresented in their evaluation, and, with the encoder kept frozen, pre-trained models still fall short of nnU-Net, the state-of-the-art reference trained from scratch. To close this gap we extend convolutional MAE pre-training with a robust reconstruction objective, a feature regularizer, and a local-global similarity objective. Using this method, we propose Curia-MAE, a multi-modal, multi-anatomy MAE model pre-trained on 300,000 CT and MRI images covering a large number of anatomical sites. On eight anatomy- and lesion-focused segmentation benchmarks, Curia-MAE improves frozen-encoder performance over a strong MAE baseline, while remaining competitive under full finetuning and superior on lesion tasks, where labeled data is scarce. These results indicate that a single frozen encoder can be reused across diverse segmentation tasks, reducing the cost of adapting and deploying such models in clinical workflows. Curia-MAE pre-trained model weights are made publicly available at https://huggingface.co/raidium/Curia-MAE.
Text-Guided Refinement of Multi-sequence Glioma Subregion Segmentation with a Vision-Language Foundation Model
Background: Accurate glioma subregion delineation is important for radiotherapy planning and longitudinal monitoring, but manual contour correction is time-consuming. Models such as nnU-Net may generalize imperfectly and lack clinician-directed text correction. Purpose: We investigated adapting a three-dimensional (3D) vision-language foundation model for text-guided brain tumor segmentation refinement. Methods: We developed a lightweight VoxTell-based framework. Pretrained VoxTell generated initial masks. Oracle prompts derived from segmentation errors encoded target, action, location, imaging evidence, edit size, and preservation constraints. Frozen Qwen/VoxTell prompt embeddings were injected through trainable projections into its multiscale decoder conditioning; other weights remained frozen. Training, validation, and testing used 901, 100, and 250 BraTS-GLI cases. Cross-dataset transfer was evaluated on 100 meningioma, metastasis, pediatric tumor, and UPENN-GBM cases. Results: On the internal test set using post-contrast T1-weighted input, correct instructions improved subregion Dice similarity coefficient (DSC; enhancing tumor, edema, and necrotic/non-enhancing core) from to . They outperformed blank prompts (; Holm-adjusted , ) and contradictory prompts (; , ). In cross-dataset testing, correct instructions improved DSC from to and outperformed contradictory instructions (; , ). Conclusion: A 3D vision-language foundation model can perform instruction-guided refinement of glioma subregion segmentations. Sensitivity to correct, blank, and contradictory prompts suggests text-dependent contour editing rather than nonspecific post-processing, supporting further evaluation as a clinician-in-the-loop tool.
EndoVLM: An Endoscopy Vision-Language Pre-training Model via Anatomy-Guided Sparsity and Progressive Alignment
The development of foundation models (FMs) is crucial for advancing endoscopic image analysis. However, existing endoscopy FMs mainly rely on self-supervised learning from uni-modal images or videos, overlooking the rich semantic knowledge contained in clinical reports. Furthermore, effectively leveraging these records is hindered by a fundamental modality gap: structured anatomical descriptions are not naturally mapped to specific frames within the high-redundancy, uncurated visual streams. In this paper, we present EndoVLM, a novel vision-language FM pre-trained on over 348K endoscopic examinations, each pairing a clinical report with its corresponding image collection. An Anatomy-Guided Sparse Pooling mechanism utilizes textual descriptions as queries to drive sparse attention, efficiently aggregating semantically salient frames into anatomy-specific visual representations across redundant image-sets. Next, a Progressive Semantic-Aware Alignment strategy models clinical taxonomy (anatomy and pathological status) via structured soft targets, bridging the gap from global patient-level matching to fine-grained localized alignment. Finally, a Semantic-Concentrated Masked Autoencoder is applied exclusively to these semantic-rich frames, integrating low-level visual precision with robust high-level semantic representation. Extensive experiments across various downstream tasks demonstrate that EndoVLM outperforms existing foundation models and remains competitive with task-specific methods. Remarkably, EndoVLM also exhibits robust zero-shot generalization capabilities, highlighting its potential for broader clinical application.
Generative AI and Foundation Models in Medical Image
In recent years, generative AI has attracted significant public attention, and its use has been rapidly expanding across a wide range of domains. From creative tasks such as text summarization, idea generation, and source code generation, to the streamlining of medical support tasks like diagnostic report generation and summarization, AI is now deeply involved in many areas. Today's breadth of AI applications is clearly distinct from what was seen before generative AI gained widespread recognition. Representative generative AI services include DALL-E 3 (OpenAI, California, USA) and Stable Diffusion (Stability AI, London, England, UK) for image generation, ChatGPT (OpenAI, California, USA), and Gemini (Google, California, USA) for text generation. The rise of generative AI has been influenced by advances in deep learning models and the scaling up of data, models, and computational resources based on the scaling laws. Moreover, the emergence of foundation models, which are trained on large-scale datasets and possess general-purpose knowledge applicable to various downstream tasks, is creating a new paradigm in AI development. These shifts brought about by generative AI and foundation models also profoundly impact medical image processing, fundamentally changing the framework for AI development in healthcare. This paper provides an overview of diffusion models used in image generation AI and large language models (LLMs) used in text generation AI, and introduces their applications in medical support. This paper also discusses foundation models, which are gaining attention alongside generative AI, including their construction methods and applications in the medical field. Finally, the paper explores how to develop foundation models and high-performance AI for medical support by fully utilizing national data and computational resources.
Few-Shot Concept Prompt Learning for Segmentation Foundation Models via Visual Grounding
Promptable segmentation foundation models (FMs) such as SAM3 and Medical SAM3 promise few-shot, interactively-specified segmentation for medical imaging through a natural language interface, yet their performance on clinical tasks falls well short of this promise. We posit that this shortfall is not an artefact of insufficient medical pretraining or imperfect prompt phrasing, but a structural limitation that will persist in any domain where paired image-text supervision is scarce, as it is across most clinical modalities. We further hypothesize that the limitation is specific to natural language as a control signal: a visually grounded prompt, learned directly from the target distribution, should recover the lost performance without additional image-text data or backbone retraining. We propose Few-Shot Concept Prompt Learning (FS-CPL), which learns a continuous concept prompt embedding from a small support set of image--mask pairs via mask supervision, with the encoder-decoder backbone frozen. Across four public benchmarks spanning ultrasound and endoscopy (BUSI, HC18, TN3K, CVC-Clinic), FS-CPL delivers absolute Dice improvements of up to over canonical text prompts and is \emph{backbone-agnostic}: it lifts both vanilla SAM3 and the domain-specifically pretrained Medical SAM3, showing that visual concept prompting is complementary to in-domain pretraining.
Location-Aware Fine-Grained Representation Learning for Medical Vision Foundation Models
Fine-grained visual representations are essential for medical image analysis, particularly when diagnostically relevant evidence is subtle and spatially localized. Modern transformer-based medical vision encoders must therefore learn patch-level representations that are both clinically meaningful and spatially consistent. Without these properties, large vision-language models (LVLMs) operate on an ambiguous visual foundation, limiting their ability to generate clinically reliable and spatially grounded responses. However, existing training strategies for medical vision encoders rarely achieve both objectives. Image-text alignment provides clinically meaningful supervision primarily at the image level, leaving the spatial localization of diagnostic evidence weakly constrained. In contrast, self-supervised learning promotes spatial consistency but lacks the semantic supervision needed to distinguish visually similar yet clinically distinct regions. To address this gap, we present LoFi, a medical vision foundation model built on location-aware fine-grained representation learning. LoFi trains a vision encoder with a lightweight large language model under grounding and grounded captioning objectives. Because these objectives require predicting location from clinical text and vice versa, spatial consistency emerges without any explicit patch-level regularization. To enable training at scale, we construct MedG, a large-scale medical grounding dataset of 4.48M image-text-box triplets curated from 84 datasets spanning 7 modalities. Across phrase grounding, visual question answering, and region-based organ classification under perturbations, LoFi consistently outperforms general-purpose and medical vision foundation models as well as state-of-the-art LVLMs. Code is available at https://github.com/myeongkyunkang/lofi-medg.
Representation Transfer of Foundation Models for Ultra-Widefield Retinal Imaging
Despite the widespread adoption of foundation models as feature extractors for medical imaging, relatively little is understood about how different pretraining strategies influence the transferability of learned representations to weakly supervised ophthalmic imaging tasks. We investigate this question in ultra-widefield (UWF) retinal imaging by evaluating foundation model representations within a patch-based multiple instance learning (MIL) framework for disease classification on UWF images. We compare Vision Transformer encoders pretrained with supervised, Masked Autoencoder (MAE), and self-distillation objectives, while keeping the downstream aggregation architecture unchanged. Within a controlled comparison of ViT-B encoders pretrained on ImageNet-1k, the choice of pretraining objective substantially influenced frozen representation transfer, with supervised and self-distillation-based models outperforming MAE. A contemporary DINOv3 model pretrained at a larger scale achieved the strongest overall performance, with a quadratic weighted kappa of 0.863 for five-class diabetic retinopathy grading, comparable with DINOv1. Attention analysis further revealed distinct patch-aggregation behaviours associated with the different pretrained representations, while partial fine-tuning substantially reduced the performance gap for MAE. These findings suggest that pretraining strategy influences both representation transferability and the subsequent aggregation of patch-level evidence within MIL, resulting in differences in downstream classification performance.
MedSAM2-Anatomy: Training-Free Inference-Time Optimization for Musculoskeletal Segmentation
High-resolution 3D segmentation of hip and shoulder anatomy from CT and MRI is essential for surgical planning, yet frozen segmentation models often fail under domain shift. CNN-based expert models are fully automatic but lack adaptability, whereas promptable foundation models generalize better but require manual prompting. We present MedSAM2-Anatomy, a training-free inference-time optimization framework that improves frozen segmentation models without retraining or human interaction. A frozen expert model generates anatomical priors that are automatically converted into multiple prompt hypotheses for a frozen 3D foundation model. Candidate masks are fused while anatomically implausible priors are rejected. No model weights are updated and no manual prompts are required. TotalSegmentator and MedSAM2 are used as representative expert and foundation models, allowing the contribution of the inference policy to be isolated. Evaluation on the independent Balgrist-V0 CT and MRI cohorts shows that inference-time optimization increases median Dice from 0.71 to 0.92 on hip MRI and from 0.89 to 0.92 on shoulder CT, while reducing median HD95 on hip MRI from 22.0 mm to 5.0 mm. On public TotalSegmentator benchmarks, the expert model remains strongest, indicating that the optimal fusion strategy depends on the reliability of the expert prior. These results demonstrate that training-free inference-time optimization provides a practical strategy for improving frozen segmentation models without manual prompting.
MoPET: Parameter-Efficient Mixture-of-Experts for Unified Medical Image Classification
Adapting deep learning models to profound clinical heterogeneity typically relies on parameter-efficient fine-tuning (PEFT) to avoid the severe overfitting associated with full end-to-end network updates. Although PEFT successfully navigates limited data scenarios, it inherently forces the training of a separate, isolated adapter for every specific diagnostic task. Consolidating these isolated adapters into a single generalist network risks negative transfer, as optimization gradients from conflicting visual domains interfere. To address this, we propose MoPET, a mixture-of-experts (MoE) method that uses a learned sparse router to direct each input through a small subset of low-rank PEFT experts injected into a frozen foundation model, sharing capacity across datasets while limiting cross-domain gradient conflict. Through selected evaluations on the MedMNIST benchmark, we first establish that PEFT outperforms full network updates, improving average accuracy from 86.50% to 88.97%. We then show that a single MoPET model consolidates four heterogeneous datasets into one network, improving average accuracy over the best isolated PEFT adapters (93.46% versus 92.83%). Finally, we show that co-training with auxiliary datasets improves accuracy on data-constrained clinical targets, raising average target accuracy over the strongest isolated adapter from 81.58% to 83.58%. Our source code is publicly available at https://github.com/sdoerrich97/mopet.
UltraSAM3: A Concept-Driven Foundation Model for Universal Ultrasound Image Segmentation
Ultrasound imaging has become increasingly widespread in clinical practice due to its portability, low cost and real-time capability, making ultrasound image segmentation important. However, ultrasound images differ substantially from CT, MRI, and other medical imaging modalities, as they are often affected by speckle noise, low contrast, acoustic shadows and ambiguous boundaries. Existing ultrasound segmentation methods are still mainly limited to task-specific models or visual-prompt-based foundation models, which are either tailored to particular tasks or require expert-provided visual prompts, making them inconvenient for flexible clinical use. To address these challenges, we propose UltraSAM3, a concept-driven foundation model for universal ultrasound image segmentation. Unlike conventional models, UltraSAM3 enables text-based target specification by adapting SAM3 to ultrasound-specific image--mask--concept triplets. The model is trained on a large-scale ultrasound segmentation corpus covering 37 public datasets and 13 anatomical categories, allowing it to align ultrasound visual patterns with clinically meaningful concepts across diverse organs and lesions. To further improve usability under realistic clinical interaction, we propose an instruction-guided agent that parses complex natural language queries into concise ultrasound concept prompts for UltraSAM3. Extensive experiments demonstrate that UltraSAM3 consistently outperforms representative concept- and text-driven biomedical segmentation models on multi-organ ultrasound benchmarks, external datasets, and visual-prompt-enhanced settings. Moreover, the agent improves segmentation robustness for complex user instructions. These results indicate that ultrasound-specific concept adaptation is effective for building generalizable and interactive ultrasound segmentation foundation models.
Do Medical Foundation Models Generalize on the African Brain?
Medical foundation models (FMs) are increasingly used for brain MRI analysis. However, their evaluation remains dominated by high-resource datasets, leaving generalization to African cohorts underexplored. We assess whether FMs generalize equally to African and non-African brain MRI data across two tasks: dementia classification using a Nigerian dataset and brain tumor segmentation using BraTS-Africa. We evaluate two generalist FMs (BrainIAC, 3DINO) and two segmentation-specific FMs (MedSAM2, Medical-SAM2) against a from-scratch baseline. For classification, FMs provide limited gains (highest ROC-AUC of 0.86 with BrainIAC), whereas for segmentation they consistently improve performance, reaching up to 0.86 Dice with MedSAM2. Performance differences between African and non-African cohorts are inconsistent and appear more related to dataset size than data origin. These results suggest that FMs do not exhibit an inherent bias against African cohorts, and highlight the limited availability and diversity of African neuroimaging datasets as the main barrier to robust evaluation and deployment.
Negative controls reveal volume-driven confounding in radiomics and imaging foundation model features
Radiomics and imaging foundation models promise non-invasive biomarkers of tumour biology, yet predictive signatures may reflect tumour volume or acquisition artifacts rather than meaningful image structure. We introduce READII-2-ROQC, an open-source framework that uses volume-preserving negative controls to assess whether radiomic and deep imaging features capture independent spatial signals. READII-2-ROQC generates voxel-perturbed images across tumour, background and whole-image regions using configurable randomization strategies, then compares feature behaviour and model performance between original and control images. Applied to three public cancer imaging cohorts, the framework processed 3,552 tumour volumes and extracted PyRadiomics and foundation-model features from original images and nine matched controls. Reproducing published survival and HPV-status signatures, we show that multiple models retain performance after spatial structure is destroyed, revealing volume-driven or contextual confounding, whereas others show perturbation-sensitive signal. READII-2-ROQC provides a scalable quality-control strategy for developing interpretable, biologically grounded imaging biomarkers and reproducible radiomics workflows.
Benchmarking Foundation and Large Language Models for Few-Shot Medical Image Segmentation
Few-shot medical image segmentation (FS-MIS) aims to segment novel regions of interest (ROIs) from a few annotated support examples. Despite rapid progress, existing FS-MIS solutions span diverse paradigms but are evaluated under inconsistent settings, leaving their relative effectiveness unclear. We introduce FAME, a unified benchmark for evaluating FS-MIS solutions, covering specialists, SAM-based methods, CLIP-based methods, and MLLM-based methods. FAME contains 14,958 test samples across 7 anatomical sites, 9 imaging modalities, and 14 ROI categories, and evaluates models under zero-shot and ten-shot settings with additional assessment of target-absence recognition and generalization under covariate and semantic shifts. Our evaluation reveals several findings. First, effective few-shot segmentation depends on how models exploit support examples: direct visual adaptation generally outperforms prompt-based strategies. Second, increasing support examples improves performance only when models can effectively utilize them. Third, semantic transfer remains substantially more challenging than imaging-domain adaptation, and strong localization ability does not necessarily imply reliable target-absence recognition. We hope FAME provides a comprehensive understanding of current FS-MIS solutions and facilitates the development of more effective and reliable few-shot medical segmentation methods.
Rethinking Artificial Intelligence in Medical Imaging: Assumptions, Reality, and Reframing
Medical imaging has served as primary proving ground for clinical artificial intelligence (AI), yet a decade of intense research has not translated into proportionate bedside impact. We argue that this gap is not primarily a product of insufficient algorithmic performance, inadequate regulation, or limited explainability. Rather, it reflects a structural misalignment, between how AI systems are designed and evaluated, and how clinical decisions are made. This Perspective identifies six interconnected dimensions of this misalignment: the dominance of pixel-only models in a multimodal clinical world; the erosion of physician trust through opaque and inflexible systems; the unfulfilled promise of foundation models in data-sparse medical domains; the persistent bottleneck of non-shareable, under-curated datasets; the gap between validated algorithms and deployable clinical platforms; and the failure of prediction-centric AI to generate actionable clinical guidance. For each dimension, we reframe the problem and propose a path forward, culminating in a vision of agentic, physician-aligned AI that extends, rather than replaces, clinical judgment.
Anatomy Contextualized Adaption of CT Foundation Models
CT vision-language foundation models have demonstrated promising performance across downstream tasks, but are typically trained with whole-volume representations that dilute fine-grained anatomical signals. Fine-grained vision-language pre-training addresses this by aligning anatomy-level visual features with anatomy-specific text, but in doing so discards the global context that whole-volume models provide. Furthermore, existing fine-grained approaches train from scratch, making them computationally expensive. We introduce Anatomy Contextualized Adaptation (ACA), a lightweight framework that adapts frozen CT foundation model representations for anatomy-level vision-language alignment while enhancing global contextualization. ACA uses TotalSegmentator to decompose CT volumes into anatomy-level embeddings, which are refined via a transformer that captures cross-anatomy relationships, and aligned to both per-anatomy and scan-level text extracted from radiology reports. Evaluated on Merlin and CT-RATE, ACA consistently outperforms both the frozen foundation model baselines and existing fine-grained methods in zero-shot finding classification, while requiring less than one hour of training once embeddings are cached. The attention weights learned by ACA's inter-anatomy transformer additionally indicate plausible cross-anatomy context routing. Altogether, these results support ACA as a lightweight approach for adapting CT foundation models to anatomically grounded vision-language alignment while preserving and enhancing global anatomical context.
Empirical investigation of 3D CT Foundation Models and Unsupervised Adaptation for Head and Neck Cancer Recurrence Prediction
The rapid emergence of 3D CT foundation models has opened new avenues for predictive modeling from CT imaging, offering a compelling alternative to traditional radiomics which is known to suffer from reproducibility issues and sensitivity to acquisition protocol variations. Yet, as these models grow in availability, a critical need arises to evaluate how well their learned representations generalize across diverse clinical settings and whether adaptation to specific downstream tasks is necessary to unlock their full potential. To address these questions, we benchmarked several 3D CT foundation models for predicting recurrence-free survival in head and neck cancer across two public datasets totaling 3,644 patients, evaluating various adaptation strategies and modality fusion mechanisms. Our findings reveal persistent difficulty in identifying features that generalize consistently across different imaging distributions, as evidenced by significant performance drops on external validation cohorts. Ultimately, the integration of imaging features with clinical data remains the most accurate approach for prognostic prediction, though achieving universal generalization across varied clinical contexts continues to represent a substantial challenge for the current generation of models.
Comparing the Performance of Foundation Model Derived Embeddings with Traditional Approaches for Distant Metastasis Prediction in Head and Neck Cancer
Background: Early prediction of distant metastasis (DM) risk in head and neck cancer (HNC) can enable timely interventions that may improve treatment outcomes. Many current machine learning methods rely on prior knowledge of the region of interest such as tumor segmentations, which require expert knowledge, is time-consuming and introduces user-dependent variability. Medical image-based foundation models have recently been developed for specific imaging modalities to streamline down-stream prediction tasks by extracting modality-relevant features. Purpose: In this study, we evaluate the effectiveness of using a foundation model as the feature extractor to predict DM risk in HNC patients and compare its performance with traditional approaches that require prior knowledge on the regions of interest. Methods: Preoperative CT images of 2327 patients from the RADCURE dataset were used. Three features-sets were created including radiomics, deep-learning based features, and CT Foundation derived features. The feature-sets were used individually in a multi-layer perceptron (MLP) to predict DM risk. Results: The model using CT Foundation embeddings outperformed the radiomics and deep learning-based models, achieving a Receiver Operating Characteristic Area Under the Curve (AUC) of 0.791, compared to AUC values of 0.772 and 0.753 for the radiomics and deep learning-based models, respectively. The CT Foundation based model had similar performance to a model that combined the use of radiomics and deep learning-based features that achieved an AUC of 0.794. Conclusions: Features based on foundation models offer a promising alternative to traditional radiomics while reducing the need for domain expertise and extensively annotated datasets. Their minimal preprocessing requirements also make them a more accessible and scalable option.
Rad-JEPA 3D: Radiology Joint-Embedding Predictive Model for 3D Computed Tomography
Self-supervised pretraining is central to 3D medical image analysis, where unlabeled CT volumes are abundant but expert annotations are scarce. Yet existing volumetric encoders often fail to preserve the coarse spatial and geometric structure that downstream reasoning depends on, limiting their performance on organ disentanglement, abnormality detection, and spatial understanding when paired with language models. We introduce Rad-JEPA 3D, a joint-embedding predictive framework that learns volumetric CT representations by predicting the latent features of a complete scan from a masked view. At its core is a hybrid H-Mamba encoder that fuses a Mamba state-space branch, which models inter-slice continuity through sequential scanning, with a grouped-query attention branch, which captures cross-plane spatial context, combined through a lightweight per-token router. To improve the quality of intermediate representations, we further propose Hidden States Orthogonal Regularization (HSOR), which aligns student-teacher hidden states and reduces feature redundancy throughout the encoder. This layer-wise regularization produces more consistent and discriminative volumetric representations, leading to improved performance on organ recognition and spatial reasoning tasks. Pretrained on approximately 120,000 CT scans, Rad-JEPA 3D attains state-of-the-art results despite its compact size: with only 4.0B total parameters, it achieves competitive results with state-of-the-art on closed-ended VQA and the best average spatial-reasoning score on the Spatial-Med benchmark. Ablation studies confirm that the hybrid block and HSOR contribute complementary gains, and that the induced spatial structure can substitute for raw language-model scale on volumetric reasoning tasks.
OrganLens: Organ-Specific Representation Learning for CT Foundation Models
A CT examination captures multiple organs, but many biomedical questions concern abnormalities, prognosis, or longitudinal change in a specific organ. These questions require a separate representation for each organ within the same CT volume. Existing CT foundation models commonly produce a single volume-level representation, while recent anatomy-aware methods either encode pre-separated organ volumes or explicitly disentangle images into organ token groups. The former may remove clinically relevant surrounding context, while the latter does not condition a shared encoder on a selected organ before its features are formed. We introduce OrganLens for organ-specific representation learning through self-supervision. An organ identity conditions a shared CT encoder, while organ-specific distillation and anatomy-mask supervision shape features for anatomy-weighted pooling into organ-specific representations. At inference, the shared model produces 11 organ-specific representations without external segmentation masks. We evaluate OrganLens on CT-RATE, RAD-ChestCT, INSPECT, and NLST across diverse acquisitions and downstream evaluations. Relative to CT-pretrained DINOv2, heart representations raise CT-RATE cardiomegaly AUROC from 0.910 to 0.953, while lung representations improve the Harrell C-index for NLST lung-cancer mortality by 14.2%. The global representation reaches INSPECT Recall@10 of 33.09% and 32.04% for text-to-image and image-to-text retrieval, respectively. Across organ-related tasks, anatomically matched representations provide stronger task-relevant signal, while the global representation retains broad utility. OrganLens offers a scalable approach to organ-specific CT representation learning with a shared encoder. More broadly, it provides the medical research community with a reusable framework for studying organ-specific disease across cohorts and clinical endpoints.