Magnetic Resonance Imaging Reconstruction

Recent momentum

-67%

1 papers in the last 28 days · 0.0% of indexed attention

Twelve weeks of publication activity for this topic as it is defined today.

Weekly history

Recent digests

What was published in this topic, kept on the site without email delivery.

Period ending 2026-09-07

2 new papers

A weekly snapshot of new work published in Magnetic Resonance Imaging Reconstruction.

41 papers

Latest in Magnetic Resonance Imaging Reconstruction

Sep 21, 2026cs.CV

MIGA:Shared-Geometry Gaussian Representation with Implicit Amplitude Modeling for Accelerated 3D Multi-Echo MRI

Three-dimensional multi-echo MRI provides rich anatomical and quantitative information, but repeated volumetric encoding prolongs acquisition and motivates k-space undersampling. Reconstructing undersampled multi-echo data requires exploiting shared anatomy while preserving echo-dependent signal variation; full-volume modeling also introduces substantial computational and memory demands. We propose MIGA, a scan-specific framework comprising shared anisotropic Gaussian geometry, a coordinate-conditioned multi-output amplitude network, and explicit echo-specific phase variables. The Gaussian geometry provides common spatial support across echoes, the implicit network models spatially structured amplitude variations, and the phase variables retain echo-specific complex signal information. All components are jointly optimized using only the acquired multi-coil k-space, requiring no fully sampled training data. Experiments showed that MIGA consistently outperformed the comparison methods across imaging tasks and acceleration factors, with larger improvements under stronger undersampling. MIGA also achieved a favorable quality-cost balance among the evaluated full-volume multi-echo methods. These results support the effectiveness of combining shared Gaussian geometry with implicit echo-dependent amplitude modeling for accelerated 3D multi-echo MRI reconstruction.
Jingran Xu, Yuanyuan Liu, Yanjie Zhu
Sep 2, 2026eess.IV

Data-Efficient Networks for Multi-Contrast MRI Reconstruction based on a Generalized Content/Style Prior

Multi-contrast MR scans contain redundant structural information that can be leveraged during reconstruction and potentially accelerate acquisition times. This idea has inspired end-to-end guided reconstruction models, leveraging one or more contrasts to guide the reconstruction of a different contrast. However, these models require large paired multi-contrast raw datasets for training, limiting their application in low-data regimes. In this work, we propose a modular framework, namely CoSMo-RecNet, for learning guided reconstruction models in the low-data regime. At its core is a reusable multi-contrast representation based on a content/style model, which can be learned from large-scale, publicly accessible, unpaired multi-contrast image datasets, without available k-space data. Using this frozen model as a multi-contrast prior and using a set of reference contrasts, the reconstruction problem reduces to a much simpler refinement problem that can be solved by a lightweight unrolled network and thus learned from small, task-specific reconstruction datasets. We demonstrate the efficacy of CoSMo-RecNet by evaluating it on the low-field 0.3 T M4Raw dataset, showing stable reconstruction quality on decreasing the raw training data budget. CoSMo-RecNet achieved higher reconstruction quality with 5 training subjects or lower compared to a parameter-count-matched MoDL trained on 100 subjects. On a data-limited and severely out-of-distribution ultra-low-field 47 mT Halbach scanner dataset, CoSMo-RecNet was superior to other viable strategies, including classical reconstruction, transfer learning, and zero-shot reconstruction.
Chinmay Rao, Efe Ilıcak, Matthias J. P. van Osch +5
Aug 10, 2026cs.CV

MPISuperRes-PnP: A Super-Resolution Zero-Shot Plug-and-Play Reconstruction Algorithm for Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is an emerging medical imaging modality. MPI is based on the non-linear response of magnetic nanoparticles to an applied magnetic field and avoids ionizing radiation. The measured signal is the voltage induced in receive coils by the particles' response. Reconstructing the particle concentration from the signal constitutes the imaging task. Even using state-of-the-art measurement-based reconstruction, the associated spatial grid is very coarse, hence super-resolution (SR) techniques are important. In this work, we propose an approach for SR in MPI inspired by energy minimization. Different methods have been proposed for SR in MPI, ranging from upscaling of the associated system matrix to interpolation of the reconstruction. Here we incorporate SR into the reconstruction task via an energy minimization formulation. Following the plug-and-play approach to energy minimization we derive a splitting scheme and a SR method for MPI where the arising Gaussian denoising task is treated with a pre-trained learned Gaussian denoiser in a zero-shot fashion. This way, we incorporate benefits of deep learning without training and avoid the need of training data. Further, we provide a quantitative and qualitative evaluation of the proposed method. Hyper-parameter are selected via an extended parameter search. The found parameters are applied for reconstruction on real data. We show the applicability of our method on synthetic and on real data (MPIData: EquilibriumModelWithAnisotropy and 2D-OpenMPI Data). The proposed method employs a deep-learning denoiser without training -- thus it does not require presently scarcely available MPI training data. The denoiser behaves conservatively, i.e., no hallucination artifacts were observed. The SR approach is generic such that it can be applied in future MPI contexts involving different regularizers or different imaging tasks.
Vladyslav Gapyak, Thomas März, Andreas Weinmann
Aug 9, 2026cs.CV

CUPA-T2*: Covariance-Aware Uncertainty Propagation and Alignment for T2* Mapping in Accelerated MRI

Quantitative T2* maps have strong potential for biomarker discovery but are limited by long scan times, rendering them impractical in clinical settings. Significant acceleration can be achieved through undersampling in k-space combined with learning-based reconstruction. However, reconstruction artifacts and noise can propagate into downstream T2* fitting, degrading its accuracy. We introduce CUPA-T2*, a framework that explicitly propagates voxel-wise inter-echo uncertainty from stochastic Monte Carlo dropout reconstructions to downstream T2* fitting via covariance-aware sampling. T2* fitting is performed with a heteroscedastic MLP and a correlation-based regularizer that encourages alignment between predicted variance and reconstruction uncertainty. Experiments on accelerated brain MRI data show tissue-dependent behavior: CUPA-T2* achieves competitive overall T2* fitting performance and improves white-matter performance at higher accelerations. Compared with a heteroscedastic baseline, the proposed framework substantially increases alignment between reconstruction uncertainty and predicted T2* variance, while also revealing a trade-off with calibration (ECE) and selective prediction performance (AURC). CUPA-T2* enables reconstruction uncertainty-aware T2* fitting and delivers voxel-wise uncertainty maps to support the interpretation of quantitative T2* estimates.
Gideon N. L. Rouwendaal, Natascha Niessen, Hannah Eichhorn +3
Jul 29, 2026cs.CV

K-space Gaussian Representation for Parallel MRI

Accelerated magnetic resonance imaging (MRI) aims to recover the k-space signal from acquired measurements, where accurate estimation of missing samples is essential for high-fidelity reconstruction. Existing k-space reconstruction methods estimate missing samples through interpolation operators or structure priors defined on discrete sampling grids. Although these formulations effectively exploit local interpolation relationships and global k-space redundancy, they reconstruct only discrete frequency coefficients and therefore do not explicitly model the underlying continuous signal. To overcome this limitation, we propose K-space Gaussian Representation (KGR), the first explicit continuous representation formulated directly in the native k-space domain. Rather than estimating unknown samples on discrete grids, KGR parameterizes the continuous signal using Gabor-Gaussian primitives with shared spatial geometry, yielding a compact representation that naturally preserves inter-coil correlations. Because unconstrained continuous fitting does not necessarily satisfy the intrinsic structural properties of multi-coil signal, the estimated representation is projected onto a low-rank manifold to enforce the algebraic constraints arising from smoothly varying phase and coil redundancy. A frequency-adaptive fitting strategy accommodates the heterogeneous characteristics of different k-space regions. Comprehensive validation across multiple datasets and sampling schemes shows consistent improvements over representative reconstruction baselines in both quantitative metrics and visual quality. These results suggest that explicit continuous parameterization of native k-space provides a principled framework for integrating continuous signal modeling with structured low-rank reconstruction.
Yu Guan, Mingyu Hu, Jiale Hu +3
Jul 22, 2026cs.CV

SHFormer: Dynamic Spectral Filtering Convolutional Neural Network and High-pass Kernel Generation Transformer for Adaptive MRI Reconstruction

Attention Mechanism (AM) selectively focuses on essential information for imaging tasks and captures relationships between distant pixel neighborhoods to compute feature representations. Accelerated MRI reconstruction benefits from AM, as the imaging process involves Fourier domain measurements that influence image representation non-locally. However, AM-based models are more adept at capturing low-frequency information with limited capacity for high-frequency representations, restricting models to smooth reconstruction. Additionally, AM-based models need mode-specific retraining for multimodal MRI data, as their knowledge is restricted to local contextual variations that may be inadequate to capture transferable features across heterogeneous domains. To address these challenges, we propose a neuromodulation-based discriminative multi-spectral AM for scalable MRI reconstruction that can (i) propagate context-aware high-frequency details for high-quality reconstruction, and (ii) capture features reusable across deviated unseen domains in multimodal MRI. The proposed network consists of a spectral filtering CNN to capture mode-specific transferable features and a dynamic high-pass kernel generation transformer focusing on high-frequency details. We evaluate our model on comparative studies in supervised and self-supervised learning, diffusion model-based training, closed-set and open-set generalization under heterogeneous MRI data, and interpretation-based analysis. Our method offers scalable, high-quality reconstruction with best improvement margins of ~1 dB in PSNR and ~0.01 in SSIM under unseen scenarios. Code: https://github.com/sriprabhar/SHFormer
Sriprabha Ramanarayanan, Rahul G. S., Mohammad Al Fahim +3
Jul 7, 2026cs.LG

Self-Supervised Implicit CEST Reconstruction via Physics-Informed Lorentz Encoding

Multi-Pool Chemical Exchange Saturation Transfer (CEST) MRI provides valuable metabolic information but is clinically limited by long acquisition times. Although sparse sampling reduces scanning time, reconstructing high-resolution Z-spectra from limited data remains an ill-posed inverse problem. Conventional interpolation and generic Implicit Neural Rep-resentations (INRs) often lack physical constraints, leading to spectral artifacts and physically invalid signals. To address this, we propose Lorentz Encoding (LE), a physics-informed framework that formulates CEST reconstruction as a self-supervised reconstruction task via implicit continuous coordinate learning. Unlike generic positional encodings, LE regularizes the continuous spectral mapping by projecting sparse coordinates into a physically constrained space governed by a combination of parametric Lorentzian profiles with learnable basis functions. This mechanism effectively reduces noise and enforces consistency with physical models. Experiments on in vivo human brain data demonstrate that LE significantly outperforms state-of-the-art methods. Specifically, under a 39-point sampling strategy, LE achieves a PSNR of 57.58 dB and an SSIM of 0.9994. Furthermore, the learned physics-informed encodings form a continuous, geometrically ordered trajectory in the latent space, ensuring accurate quantitative metabo-lite mapping (APT, NOE, MT).
Dexuan Li, Yupeng Wu, Chenglong Wang +4
Jul 3, 2026physics.med-ph

Harmonic-Aware Transformer for Real-Time Catheter Localization in Interventional Procedures of Magnetic Particle Imaging

Magnetic particle imaging (MPI) enables real-time, radiation-free tracking of magnetic nanoparticle-coated instruments, making it highly suitable for interventional procedures. This study proposes a harmonic-aware transformer framework that directly predicts catheter tip positions from raw MPI voltage signals, eliminating the need for image reconstruction and reducing computational latency. The framework incorporates frequency-domain preprocessing to isolate the 2nd to 8th drive-field harmonics, enhancing the signal-to-noise ratio while preserving motion-relevant features. A transformer architecture with six encoder layers and eight attention heads is employed to learn spatio-temporal dependencies across the three receive axes (x, y, z) for accurate three-dimensional position estimation. The model is trained on simulated MPI signals and evaluated on real in vitro datasets under standard, bending, and heartbeat-like motion conditions. The proposed method achieves sub-millimeter localization accuracy, with a minimum L2 error of 0.103 +/- 0.092 mm and mean absolute errors (MAEs) of 0.039 +/- 0.046 mm, 0.054 +/- 0.049 mm, and 0.060 +/- 0.044 mm along the (x, y, z) axes, respectively, for the bending dataset. Across all datasets, the MAE ranges from 0.165 mm to 0.655 mm, demonstrating consistent performance. The optimized inference achieves a latency of 0.55 ms per frame and a throughput of approximately 1800 frames per second, confirming real-time capability. Compared with conventional MPI-guided approaches relying on image reconstruction, the proposed framework provides improved accuracy, reduced latency, and enhanced robustness under complex motion conditions. These results highlight the potential of harmonic-aware transformer models as efficient and scalable solutions for real-time catheter localization in interventional MPI.
Abuobaida M. Khair, Wenjing Jiang, Xiaoli Yang +2
Jul 2, 2026eess.IV

Self-Auditing Residual Drifting for Pathology-Preserving Accelerated Knee MRI

Accelerated magnetic resonance imaging reduces acquisition time, but reconstruction from undersampled k-space can blur diagnostically relevant structures or introduce failures that are not captured by global image metrics. We propose SA-RDM-DC, a Self-Auditing Residual generative Drifting Model with Data Consistency for accelerated knee MRI. The method adapts the newly proposed generative drifting paradigm to accelerated MRI by training a physics-conditioned drift field from the zero-filled reconstruction toward the fully sampled residual correction. It predicts image- and missing-k-space residual corrections, enforces data consistency with acquired k-space, uses frequency-aware and residual drifting supervision to recover fine detail, and produces dense error maps and slice-level risk scores in the same inference pass. We evaluate SA-RDM-DC on multi-coil fastMRI knee data at acceleration factors of 4, 8, and 12, with fastMRI+ pathology annotations for region-level and classifier-based task preservation, and on SKM-TEA for zero-shot and fine-tuned protocol-shift evaluation. Compared with zero-filled reconstruction, UNet-image-SENSE, DC-UNet, Score-Diffusion, ELF-Diff, SENSE-VarNet, and MoDL baselines, SA-RDM-DC achieves the highest SSIM across fastMRI acceleration factors while retaining subsecond per-slice inference and avoiding the long sampling time of iterative diffusion baselines. In pathology-aware analysis, SA-RDM-DC preserves lesion-region structural fidelity and reduces meniscus prediction instability. Its self-auditing scores strongly identify high-error reconstructions on fastMRI and partially transfer as a selective-review signal under SKM-TEA protocol shift. These results support reconstruction evaluation that jointly considers image fidelity, pathology preservation, runtime, and case-specific reliability.
Qing Lyu, Jianxu Wang, Mohammad Kawas +2
Jul 1, 2026cs.CV

High-dimensional Embedding Prior for Noisy K-space Domain MRIReconstruction

Magnetic resonance imaging (MRI) reconstruction under realistic acquisition conditions can be fundamentally viewed as estimating the underlying k-space distribution from incomplete and noise-corrupted measurements. While diffusion models have recently shown strong potential as generative prior for inverse problems,existingapproachesstruggletohandlenoisyreconstruction settings, especially when operating directly in k-space domain. In this work, we propose a unified high-dimensional k-space reconstruction framework tailored for noisy inverse problems, whichenhancesdiffusion-based solversthroughrepresentation lifting.Ratherthanmodifyingthe underlying optimization procedures, the proposed framework augments the data representation space, enabling existing diffusion-based solvers to operate on enriched k-space embeddings with improved expressiveness. Extensive experiments on both in-house and public datasets across varying noise levels and undersampled factors demonstrate that the proposed frame work consistently improves reconstruction quality for multiple diffusion-based inverse solvers. Notably, the largest gains are observed in high-noise regimes, which is consistent with our theoretical analysis of error propagation under high-dimensional representation. These results suggest that high-dimensional representation provides a general and model-agnostic mechanism for improving diffusion-based MRI reconstruction in noisy settings, offering a new perspective on robust k-space generative modeling for practical inverse problems. The code will be available at https://github.com/yqx7150/HEP-MRIRec.
Yu Guan, Tianjia Huang, Qinrong Cai +3
Jun 26, 2026eess.IV

Measured-Subspace Consistency: A Plug-and-Play Operator for Diffusion Posterior Sampling in Accelerated MRI Reconstruction

Diffusion posterior samplers for accelerated MRI can reconstruct accurately yet still disagree on the acquired k-space across samples, placing posterior variability on coefficients the scanner has already measured. We identify this measured-subspace leakage as a physical-admissibility failure. Under a hard-constraint model it violates the measurement constraint and inflates the reported uncertainty with disagreement about coefficients the scanner has already determined. To quantify this leakage, we introduce complementary measured- and unmeasured-subspace k-space dispersion metrics (MSD/USD). We then present Measured-Subspace Consistency (MSC), a training-free terminal correction that wraps any compatible image-space posterior sampler with a standard multi-coil consistency lock. The ideal lock follows classical range/null-space data consistency. Our contribution is to repurpose it as a black-box posterior audit and correction rather than a new reconstructor or learned sampler. Theoretically, we prove that the ideal transform confines pairwise sample differences to the MRI null space and bound the residual cross-subspace coupling left by practical sensitivity-weighted implementations. Across six base samplers and two MRI anatomies, including out-of-distribution transfer where a knee prior reconstructs brain, MSC substantially reduces measured-subspace dispersion for Soft samplers (a median 16.5x reduction for DPS across five brain contrasts, up to ~29x), while preserving unmeasured-subspace diversity and acting as a near-identity map for Consistent ones. Furthermore, MSC maintains or modestly improves PSNR/SSIM, with no retraining, retuning, or significant computational overhead.
Junhyeok Lee, Kyu Sung Choi
Jun 19, 2026eess.IV

Deep Unrolled Networks in Representation Space Applied to MRI Reconstruction

Deep unrolled networks (DUNs) integrate physical forward models with learned regularization in cascaded network architectures, achieving exceptional performance in inverse problems while maintaining interpretability. While most DUNs operate in the object domain (e.g., image space), recent variants explored representation spaces for improved information flow. However, these methods rely on heuristic methods for data consistency (DC), sacrificing fidelity with measurements. In this work, we introduce DUNE (Deep Unrolled Networks in rEpresentation space), a framework that maintains exact adherence to physical measurements while operating in learned representation spaces. By deriving the DC gradient via the chain rule and implementing it through the Vector-Jacobian Product (VJP), we enable exact backpropagation of measurement residuals into the representation space. This formulation supports diverse architectural backbones, including pre-trained encoders to guide the iterative process. We assess DUNE against state-of-the-art baselines on accelerated MRI reconstruction tasks, demonstrating that exact VJP-based gradients yield superior reconstruction quality and structural fidelity across both single-channel portable low-field and multi-channel clinical high-field MRI acquisitions. The code will be available upon publication at https://github.com/EfeIlicak/DUNE.
Efe Ilıcak, Baris Imre, Chloé Najac +4
Jun 16, 2026cs.CV

Recover Semantics First, Generate Better: Improved Latent Modeling for 3D MRI Reconstruction and Cross-Contrast Synthesis

Multi-contrast magnetic resonance imaging (MRI) provides complementary information for clinical diagnosis. However, acquiring all MRI sequences is often time-consuming and costly. Recent generative models perform cross-contrast synthesis to address this issue by inferring absent contrasts from the available ones. Nevertheless, synthesizing 3D MRI presents significant challenges. Due to the massive volume sizes, operating directly in the pixel space is computationally prohibitive; therefore, a common approach is to first compress the 3D volumes into a latent space and subsequently train generative models in that space. We observe that existing compression architectures face several critical issues: they under-preserve long-range anatomical coherence, discard clinically meaningful semantics, and rely on optimization objectives that lead to over-smoothed reconstructions. Ultimately, these shortcomings compromise the performance of subsequent generative models. In this work, we propose a semantics-first latent modeling framework for 3D MRI reconstruction and cross-contrast synthesis. Specifically, we introduce a Latent Harmonization Encoder (LHE) to capture global anatomical dependencies, ensuring coherent volumetric representations. To mitigate semantic degradation during latent compression, we further design a Semantic Recovery Block (SRB) that injects high-level priors from a self-supervised semantic teacher, enhancing contrast-aware separability in the latent space. Additionally, we propose an Anatomy-aware Frequency Loss (AFL) to adaptively preserve diagnostically relevant high-frequency structures. Extensive experiments on two public multi-contrast MRI datasets demonstrate consistent improvements in reconstruction fidelity and cross-contrast synthesis quality. Our code is available at https://github.com/script-Yang/RSF.
Yonghao Chen, Sicheng Yang, Rui Tang +1
Jun 15, 2026cs.CV

Trustworthy MRI Reconstruction via Bayesian Uncertainty Quantification with Sparsity Prior Models

We propose a novel Bayesian framework for joint image reconstruction and uncertainty quantification from compressed sensing magnetic resonance imaging data. The problem is formulated as a linear inverse problem, where prior distributions are assigned to the unknown image parameters. Specifically, the image is assumed to be sparse in a given transform domain. We develop a general framework applicable to any sparsifying transform and demonstrate its performance using (1) a total variation transform based on image spatial gradients and (2) a wavelet-domain transform. Bayesian inference is performed using a split-and-augmented Gibbs sampler, while the resulting non-differentiable conditional distributions are efficiently sampled using a proximal Markov chain Monte Carlo method. The proposed algorithms are validated on both single-coil and multi-coil datasets using various k-space sampling patterns and acceleration factors. The results demonstrate that the proposed Bayesian methods consistently outperform their optimisation-based counterparts in image reconstruction while providing uncertainty estimates for the reconstructed images. Furthermore, the estimated uncertainty maps show a strong correlation with the true reconstruction errors and substantially outperformed deep learning-based uncertainty estimation methods.
Ahmed Karam Eldaly, Matteo Figini, Daniel C. Alexander
Jun 13, 2026cs.CV

Variational Network with Wavelet-based UNET in Accelerated MRI Reconstruction from Under Sampled K-space Data

Fully sampled MRI requires dense k-space acquisition, leading to long scan times, reduced clinical throughput, and increased sensitivity to patient motion. Accelerated MRI addresses this by acquiring undersampled k-space data and reconstructing the missing information computationally. However, reconstruction from undersampled measurements is highly ill-posed and can introduce aliasing artifacts, noise amplification, and loss of anatomical detail. Although conventional parallel imaging and compressed sensing methods mitigate these issues, and deep learning methods have further improved reconstruction quality, preserving high-frequency structures under aggressive undersampling remains challenging. In this work, we propose a Variational Network with a Wavelet-based U-Net (W-UNet) for accelerated MRI reconstruction. The framework combines physics-guided iterative reconstruction with learnable multi-scale frequency representations. Standard pooling operations are replaced with Discrete Wavelet Transform and Inverse Wavelet Transform modules, enabling lossless downsampling while preserving low-frequency structure and high-frequency edge details. Integrated into the refinement and sensitivity map estimation stages, the proposed design improves artifact suppression, feature preservation, and reconstruction fidelity in both single-coil and multi-coil settings. Experiments on fastMRI knee and M4Raw brain datasets show state-of-the-art performance. Ablation studies further confirm the effectiveness of wavelet-based feature decomposition for accelerated MRI reconstruction.
Yasir Arafat Prodhan, Shaikh Anowarul Fattah
Jun 13, 2026cs.CV

Physics-Driven Zero-Shot MRI Reconstruction with Non-local Image Priors

Zero-Shot Self-Supervised Learning (ZS-SSL) has emerged as a promising paradigm for accelerated Magnetic Resonance Imaging (MRI) reconstruction, eliminating the reliance on fully-sampled external datasets. However, learning solely from a single under-sampled scan suffers from supervision scarcity and optimization instability, often leading to overfitting or artifacts. To address these challenges, we propose a robust physics-driven ZS-SSL framework that synergizes physical consistency with image-domain non-local priors. Our method introduces three core innovations: (1) a Coil Sensitivity Map (CSM)-Guided Dynamic Repository, which stabilizes the training trajectory by filtering physically inconsistent artifacts based on coil sensitivity constraints; (2) a SPIRiT-based regularization, which enforces k-space self-consistency via a learned correlation kernel and stochastic masking; (3) a Non-Local Self-Similarity (NSS) Pixel Bank, which leverages the high-fidelity reference established by the former modules to explicitly mine non-local anatomical similarities, thereby augmenting supervision in the image domain. Extensive experiments on the FastMRI dataset demonstrate that our approach achieves state-of-the-art performance, particularly under high acceleration factors, effectively bridging the gap between zero-shot learning and supervised methods. The code is available at https://github.com/Zolento/NS-SSL.
Lingtong Zhang, Wenlei Li, Mu He +2
Jun 9, 2026cs.CV

DD-INR: Dynamics-Driven Implicit Neural Representation for Accelerated Whole-Brain Functional MRI Reconstruction

Accelerated acquisition of fMRI enables enhanced detection of neurovascular (BOLD) activity in the brain, but image reconstruction becomes challenging with high k-space undersampling: Task-evoked BOLD signals are small in magnitude, which traditional anatomical MRI reconstruction methods fail to recover, as they favor spatial accuracy over temporal fidelity. We present DD-INR, a Dynamics-Driven Implicit Neural Representation framework tailored for accelerated fMRI that benefits from incoherent time-varying sampling and a tailored spatiotemporal prior, outperforming traditional methods, demonstrated in simulation and in-vivo acquisition, both in terms of image quality and retrieval of activation patterns. DD-INR achieves this by splitting the fMRI data into a static background and a temporally varying dynamic component, representing only the dynamics with a dedicated INR, thereby focusing the model's capacity on activation-relevant changes while remaining compact. In general, DD-INR provides a promising framework for accelerated fMRI reconstruction, with the potential to improve the sensitivity and robustness of fMRI studies within practical scan time limits. The source code is available at https://github.com/JoosenLi/DD-INR.
Qiaoxin Li, Caini Pan, Pierre-Antoine Comby +2
Jun 3, 2026eess.IV

L-TGVN: Leveraging Longitudinal Priors for Personalized Rapid MRI

MRI provides excellent soft-tissue contrast without ionizing radiation, but long acquisition times increase patient discomfort while also raising exam costs and limiting scanner throughput. A common approach to reduce scan time is to acquire fewer measurements, which yields an ill-posed linear inverse problem; recovering diagnostic-quality images therefore requires incorporating prior knowledge beyond the measured data. In follow-up exams, the most recent prior scan of a patient can provide a highly informative subject-specific context, but practical use is complicated by temporal changes (including pathology progression), misalignment between scans, and protocol drift across acquisitions. In this work, we introduce L-TGVN, a Longitudinal Trust-Guided Variational Network that leverages prior scans as side information to reconstruct the current scan from heavily undersampled measurements. Crucially, L-TGVN constrains the influence of prior scans to be consistent with the acquired measurements. Unlike many existing longitudinal reconstruction methods, it does not require explicit pre-registration between prior and current scans. It further accommodates differences in acquisition protocols across visits (e.g., changes in sequence parameters). We evaluate L-TGVN against matched-capacity baselines, including prior-guided methods and methods that do not use longitudinal priors, and observe consistent improvements in standard quantitative metrics together with better preservation of fine structures at challenging accelerations. Source code is available at github.com/sodicksonlab/L-TGVN.
Arda Atalık, Sumit Chopra, Daniel K. Sodickson
Jun 2, 2026cs.CV

Prospective Dynamic 3D MRI Reconstruction via Latent-Space Motion Tracking from Single Measurement

Prospective reconstruction is crucial in many clinical applications such as MRI-guided radiotherapy, which demands accurate image reconstruction and fast motion estimation from currently acquired measurements. However, prospective reconstruction remains challenging due to ultra-sparse sampling and stringent latency requirements. In this work, we propose PDMR, a Prospective Dynamic 3D MRI Reconstruction framework with latent-space motion tracking. Our core idea is to learn an efficient and generalizable latent manifold of motion fields offline, enabling rapid online adaptation for prospective reconstruction. Specifically, we parameterize the deformation vector fields (DVFs) on a low-dimensional manifold, effectively reducing the search space for fast online adaptation, and employ a tri-plane representation to achieve geometry-aware and memory-efficient encoding of 3D motion. Experiments on both XCAT digital phantoms and in-house abdominal MRI datasets demonstrate that PDMR achieves high-fidelity and temporally consistent reconstruction across multiple prospective scenarios (Immediate and After-2min), outperforming state-of-the-art retrospective and online methods. Our results suggest a promising pathway toward ultra-fast, motion-aware prospective MRI reconstruction in clinical practice.
Lixuan Chen, Zhongnan Liu, Jesse Hamilton +3
May 29, 2026eess.IV

MoE-dqINR: A Unified Mixture-of-Experts Implicit Neural Representation Framework for Scan-Specific Dynamic and Quantitative MRI Reconstruction

Undersampled magnetic resonance imaging (MRI) reconstruction seeks to recover temporally or contrast-varying image series from incomplete multicoil k-space data while preserving state-dependent fidelity for dynamic and quantitative MRI (qMRI). Existing scan-specific implicit neural representations (INRs) often use monolithic spatiotemporal coordinate fields, explicit subspaces, motion or deformation models, calibration variables, or sequence-specific quantitative signal models. These design choices can limit flexibility in sharing spatial information while adapting image synthesis across acquisition states. Moreover, many INR-based baselines remain computationally demanding, typically requiring per-scan optimization times on the order of hundreds to thousands of seconds. We propose MoE-dqINR, a scan-specific multicoil MRI reconstruction framework that factorizes the image-domain representation into shared spatial experts and a state-conditioned routing pathway. Spatial experts encode reusable coordinate-dependent image content, whereas routing weights, conditioned on ordered acquisition states, synthesize each dynamic frame or contrast state from a common expert bank. The representation is coupled to a multicoil MRI forward model, uses the normalized state index to drive routing in both dynamic and quantitative MRI. By separating shared spatial representation from state-dependent synthesis, the framework provides an image-first architecture for dynamic and quantitative MRI while reducing scan-specific INR optimization to approximately 30 s per scan in our experiments. The proposed formulation establishes state-conditioned mixture-of-experts INR as a scan-specific multicoil MRI reconstruction prior that unifies shared spatial representation, dynamic- and qMRI-specific synthesis, and practical per-scan efficiency.
Yinzhe Wu, Fanwen Wang, Zhenxuan Zhang +3
May 27, 2026cs.LG

Geometry-Correct Diffusion Posterior Sampling with Denoiser-Pullback Curvature Guidance and Manifold-Aligned Damping

Diffusion posterior sampling conditions diffusion priors on measurements, but data-consistency updates are typically scaled by hand-tuned guidance weights and can destabilize sampling under stiff, operator-dependent curvature. We replace scalar guidance with a per-noise-level damped Gauss--Newton correction computed in diffusion-state coordinates. The correction pulls likelihood gradients back through the denoiser, uses a one-sided curvature model that avoids forward denoiser Jacobians, and applies diffusion-calibrated rank-one damping aligned with the denoiser residual. Each correction is solved with matrix-free GMRES using automatic differentiation, and sampling proceeds with a variance-preserving Langevin transition with a closed-form drift/noise split. On FFHQ and ImageNet across inverse problems, it achieves competitive PSNR/SSIM/LPIPS while running markedly faster than most of the compared baselines; on accelerated MRI reconstruction, it achieves the best PSNR/SSIM among the compared baselines.
Seunghyeok Shin, Minwoo Kim, Dabin Kim +1
May 26, 2026cs.CV

CoilDrop-MRI: Self-supervised physics-guided MRI reconstruction with coil dropout

Self-supervised deep learning-based methods have shown great promise for accelerated magnetic resonance imaging (MRI) reconstruction, achieving high image quality without requiring fully sampled data for training. These methods typically partition the acquired data into two disjoint subsets to construct input-target pairs for optimizing the reconstruction network. However, existing approaches perform this partition exclusively within the spatial frequency (k-space) domain, leaving the coil dimension unexplored. To enforce full exploitation of signal correlation across receiver coils, we propose CoilDrop-MRI, which applies coil-wise dropout to the input and uses the dropped data as training targets in a self-supervised framework. This method is integrated into unrolled architectures in both image-domain (SENSE) and k-space (SPIRiT) formulations. We further demonstrate its versatility by extending CoilDrop-MRI to multi-shot, phase-corrected diffusion MRI (dMRI) reconstruction. CoilDrop-MRI is extensively validated on multi-site, multi-field-strength (0.3T, 0.55T, and 3T), and multi-modality (T1-weighted, T2-weighted, T2-FLAIR, and dMRI) datasets and consistently outperforms state-of-the-art self-supervised methods, achieving quality comparable to supervised reconstruction methods without requiring fully sampled reference training data. Moreover, CoilDrop-MRI exhibits strong data efficiency and robust generalization across imaging conditions, establishing it as a practical and versatile framework for self-supervised parallel MRI reconstruction.
Tongxi Song, Ziyu Li, Zihan Li +6
May 21, 2026cs.CV

MotionDPS: Motion-Compensated 3D Brain MRI Reconstruction

Magnetic resonance imaging (MRI) is highly susceptible to patient motion due to its relatively long acquisition times and the fact that data are acquired sequentially in k-space. Even small patient movements introduce phase inconsistencies across measurements, leading to severe artifacts such as blurring, ghosting, and geometric distortions that can compromise diagnostic quality. Retrospective motion compensation remains challenging, particularly in accelerated acquisitions, due to the ill-posed nature of the joint reconstruction and motion estimation problem. In this work, we propose a unified Bayesian framework for motion-compensated 3D MRI that jointly estimates the anatomical image, rigid-body motion parameters, and coil sensitivity maps directly from motion-corrupted k-space data. Our approach integrates pretrained 3D complex-valued score-based diffusion models as expressive anatomical image priors within a physics-based forward model. Inference is performed by alternating diffusion posterior image updates with efficient proximal optimization steps for motion and coil sensitivity estimation, enabling fully unsupervised reconstruction without the need for paired motion-free training data. Experiments on simulated and real-motion brain MRI datasets demonstrate that the proposed method achieves improved image quality and motion robustness compared to state-of-the-art classical and learning-based motion correction techniques, particularly in the presence of severe motion and high acceleration.
Antonio Ortiz-Gonzalez, Erich Kobler, Lukas Schletter +1
May 21, 2026cs.CV

SO-Mamba: State-Ownership Mamba for Unrolled MRI Reconstruction

Accelerated MRI reconstruction requires recovering missing details while preserving anatomically coherent structures across large spatial regions. State-space models such as Mamba provide efficient long-range modeling, making them attractive learned regularizers for unrolled reconstruction. However, in a data-consistency-coupled unrolled solver, different stages operate on different reconstruction iterates, where the resident carrier should preserve coherent reconstruction content across stages while stage-dependent non-resident evidence is tied to the current update. Treating these roles uniformly can place persistent resident-carrier evidence and update-dependent non-resident evidence into the same recurrent content route. We therefore propose SO-Mamba, a state-ownership Mamba regularizer that assigns reconstruction evidence within each Mamba stage to recurrent residency, state-interface access, and non-state output correction. SO-Mamba implements this ownership rule with a State-Ownership Router (SOR), which constructs a resident carrier for recurrent content and routes non-resident evidence to affine modulation of the B/C state interfaces and an output correction outlet. The resident carrier supplies the Mamba content route, while the non-resident evidence stream adapts the state interfaces and contributes through the output outlet without entering the recurrent content route. We further introduce a two-level outer-band leakage diagnostic that separates hidden-state storage from readout expression by measuring outer-band energy in the selective-scan state trajectory and the post-scan Mamba readout. Experiments on five public MRI reconstruction benchmarks spanning diverse anatomies, sampling patterns, and coil configurations show that SO-Mamba consistently improves over CNN-, Transformer-, and Mamba-based baselines with competitive computational efficiency.
Pengcheng Fang, Hongli Chen, Fangfang Tang +3
May 20, 2026cs.CV

MRecover: A Conditional Generative Model for Recovering Motion-Corrupted MR images Using AI Generated Contrast

Hippocampal subfield segmentation requires high-resolution T2w turbo spin echo (TSE) MRI, yet this sequence is susceptible to motion artifacts, leading to substantial data loss. We developed a conditional generative model (MRecover) that synthesizes routinely acquired T1w images to create TSE images with autoregressive slice conditioning for volumetric consistency. Trained on 7T MRI data (n=577), the model achieved high in-domain fidelity (n=148, SSIM=0.84, FSIM=0.94) and generalized well to out-of-domain 3T data: subfield volumes from synthesized and the as-acquired images closely matched: (n=416, r=0.87-0.97) and yielded 31.8% more analyzable subjects in the motion-affected ADNI3 dataset after quality control (593 vs 450). The synthesized images also achieved larger effect sizes due to increasing the sample size for diagnostic group differences in hippocampal subfield atrophy (whole hippocampus ε2ε^2= 0.121-0.100 vs. 0.086-0.062, left-right hemispheres). Project page: https://jinghangli98.github.io/MRecover/
Jinghang Li, Tales Santini, Courtney Clark +13
May 19, 2026eess.IV

Next-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction

MRI reconstruction is an inherently ill-posed inverse problem, since incomplete measurements admit many plausible solutions. This ambiguity becomes more severe under high acceleration, where pixel-domain continuous predictors tend to average over feasible reconstructions and suppress high-frequency anatomy. We address this limitation by moving reconstruction to discrete multi-scale latent space and posing it as autoregressive next-acceleration-scale prediction. Leveraging discrete priors proven effective in visual autoregressive modeling, our method restricts the solution to compact sequences of codebook tokens, enabling sharp reconstructions even from extremely sparse measurements. This discrete autoregressive formulation also aligns naturally with modern large language model post-training techniques. Building on this observation, we introduce on-policy privileged information distillation for visual autoregressive modeling, where a teacher is provided training only privileged context that is unavailable at inference, in our case fully sampled acquisitions, and supervises a student trained on its own rollouts, leading to consistent reconstruction gains. Through extensive experiments on the fastMRI benchmark, we show that our approach delivers improved reconstruction performance across diverse sampling patterns under extreme undersampling. Project website is \href{https://yilmazkorkmaz1.github.io/discrete-mri-reconstruction-opd/}{here}.
Yilmaz Korkmaz, Vishal M. Patel
May 18, 2026physics.med-ph

Rapid online deep artifact suppression for real-time spiral bSSFP CMR with blipped-CAIPI simultaneous multi-slice imaging at 1.5 T

Purpose: Real-time (RT) bSSFP MRI enables fast free-breathing cardiovascular imaging but requires 10-16 slices for functional assessment, resulting in prolonged scan times. Simultaneous multi-slice (SMS) imaging can reduce acquisition time but when combined with non-Cartesian trajectories, it relies on iterative reconstructions that preclude online use. This study investigates deep artifact suppression to facilitate rapid, online reconstruction of RT-SMS. Methods: A spiral bSSFP SMS RT sequence with two simultaneously acquired slices was implemented at 1.5 T. Reconstruction used slice separation in k-space, followed by deep artifact suppression in image space using a 3D U-Net. Ten healthy volunteers were imaged. RT-SMS image quality and reconstruction time were compared between deep artifact suppression and compressed sensing (CS) reconstructions. Left (LV) and right (RV) ventricular volumes at end diastole (EDV) and end systole (ESV) and LV mass (LVM) were compared between RT-SMS with deep artifact suppression and reference-standard breath-hold (BH) imaging. Results: The RT-SMS acquisition was ~13x faster than BH imaging (15 s vs 3 min 15 s). RT-SMS reconstruction using deep artifact suppression was ~50x faster than CS (30 s vs 24 min 55 s). Deep artifact suppression consistently outperformed CS in quantitative and qualitative image quality (p<0.001). Functional agreement between BH and RT-SMS with deep artifact suppression was good (LVEDV: -7.5 +/- 6.8 ml, LVESV: -0.9 +/- 4.2 ml, RVEDV: -6.4 +/- 8.4 ml, RVESV: 0.2 +/- 10.7 ml, LVM: -10.3 +/- 11.0 g). Conclusion: Online deep artifact suppression reconstruction for RT-SMS bSSFP CMR enables free-breathing short-axis coverage with a substantial reduction in acquisition and reconstruction time while maintaining diagnostic image quality.
Julius Åkesson, Iulius Dragonu, Einar Heiberg +6
May 18, 2026cs.SD

SIREM: Speech-Informed MRI Reconstruction with Learned Sampling

Real-time magnetic resonance imaging (rtMRI) of speech production enables non-invasive visualization of dynamic vocal-tract motion and is valuable for speech science and clinical assessment. However, rtMRI is fundamentally constrained by trade-offs among spatial resolution, temporal resolution, and acquisition speed, often leading to undersampled k-space measurements and degraded reconstructions. We propose SIREM, a speech-informed MRI reconstruction framework that uses synchronized speech as a cross-modal prior. The central idea is that vocal-tract configurations during speech are correlated with the produced acoustics, making part of the image content predictable from audio. SIREM models each frame as a fusion of an audio-driven component and an MRI-driven component through a spatial weighting map. The audio branch predicts articulator-related structure from speech, while the MRI branch reconstructs complementary content from measured k-space data. We further introduce a learnable soft weighting profile over spiral arms, enabling a differentiable study of how k-space arm usage interacts with speech-informed fusion. This yields a unified multimodal formulation that combines audio-driven prediction, MRI reconstruction, and sampling adaptation. We evaluate SIREM on the USC speech rtMRI benchmark against standard baselines, including gridding, wavelet-based compressed sensing, and total variation. SIREM introduces a speech-informed reconstruction paradigm that operates in a substantially higher-throughput regime than iterative methods while preserving anatomically plausible vocal-tract structure. These results establish an initial benchmark for multimodal speech-informed rtMRI reconstruction and highlight the potential of synchronized speech as an auxiliary prior for fast reconstruction. The source code is available at https://github.com/mdhasanai/SIREM
Md Hasan, Nyvenn Castro, Daiqi Liu +6
May 12, 2026eess.IV

NexOP: Joint Optimization of NEX-Aware k-space Sampling and Image Reconstruction for Low-Field MRI

Modern low-field magnetic resonance imaging (MRI) technology offers a compelling alternative to standard high-field MRI, with portable, low-cost systems. However, its clinical utility is limited by a low Signal-to-Noise Ratio (SNR), which hampers diagnostic image quality. A common approach to increase SNR is through repetitive signal acquisitions, known as NEX, but this results in excessively long scan durations. Although recent work has introduced methods to accelerate MRI scans through k-space sampling optimization, the NEX dimension remains unexploited; typically, a single sampling mask is used across all repetitions. Here we introduce NexOP, a deep-learning framework for joint optimization of the sampling and reconstruction in multi-NEX acquisitions, tailored for low-SNR settings. NexOP enables optimizing the sampling density probabilities across the extended k-space-NEX domain, under a fixed sampling-budget constraint, and introduces a new deep-learning architecture for reconstructing a single high-SNR image from multiple low-SNR measurements. Experiments with raw low-field (0.3T) brain data demonstrate that NexOP consistently outperforms competing methods, both quantitatively and qualitatively, across diverse acceleration factors and tissue contrasts. The results also demonstrate that NexOP yields non-uniform sampling strategies, with progressively decreasing sampling across repetitions, hence exploiting the NEX dimension efficiently. Moreover, we present a theoretical analysis supporting these numerical observations. Overall, this work proposes a sampling-reconstruction optimization framework highly suitable for low-field MRI, which can enable faster, higher-quality imaging with low-cost systems and contribute to advancing affordable and accessible healthcare.
Tal Oved, Efrat Shimron
May 11, 2026cs.CV

Product-of-Gaussian-Mixture Diffusion Models for Joint Nonlinear MRI Reconstruction

Recently, diffusion models have attracted considerable attention for magnetic resonance image reconstruction due to their high sample quality. However, most existing methods rely on large networks with opaque time-conditioning mechanisms, and require offline coil sensitivity estimation. This results in limited interpretability of the reconstruction process and reduced flexibility in the acquisition setup. To address these limitations, we jointly reconstruct the image and the coil sensitivities by combining the parameter-efficient product-of-Gaussian-mixture diffusion model as an image prior with a classical smoothness prior on the coil sensitivities. The proposed method is fast and robust to both contrast and anatomical distribution shifts as well as changing k-space trajectories. Finally, we propose a more expressive parameterization of the image prior which improves results in denoising and magnetic resonance image reconstruction.
Laurenz Nagler, Martin Zach, Thomas Pock
May 8, 2026eess.IV

Model-based Dynamic 3D MRI Reconstructions using Neural Fields and Tensor Product Expansions

Conventional MRI reconstruction methods treat images and coil sensitivities as discrete objects, leading to high memory demands and limited structural awareness that hamper effective regularization. These limitations hinder accurate reconstruction in highly undersampled scenarios, such as dynamic 3D cardiac magnetic resonance (CMR). We introduce a discretization-free, memory-efficient, model-based framework for dynamic 2D and 3D MRI reconstruction from highly undersampled data. We represent magnetization and coil sensitivities as continuous objects -- differentiable functions -- using tensor products of univariate neural fields. This tensor product structure enables scalable optimization in high-dimensional spatiotemporal settings. Our method outperforms state-of-the-art model-based reconstructions in dynamic 2D and 3D MR settings, preserving structure and motion even under aggressive undersampling (e.g., acceleration factor 16).
Ray Sheombarsing, Max van Riel, David Heesterbeek +2
May 5, 2026cs.CV

MK-ResRecon: Multi-Kernel Residual Framework for Texture-Aware 3D MRI Refinement from Sparse 2D Slices

Magnetic Resonance Imaging (MRI) acquisition remains a time-intensive and patient-straining process, as prolonged scan dura- tions increase the likelihood of motion artifacts, which degrade image quality and frequently require repeated scans. To address these chal- lenges, we propose a novel framework with two models MK-ResRecon and IdentityRefineNet3D to reconstruct high-fidelity 3D MRI volumes from sparsely sampled 2D slices-requiring only 12.5% of the axial slices for full resolution 3D reconstruction. MK-ResRecon predicts missing in- termediate 2D slices using a multi-kernel texture-aware loss, preserving fine anatomical details. IdentityRefineNet3D refines the predicted slices and the original sparse slices as a single 3D volume to obtain a smooth anatomical structure. We train the models on a large T1-sequence POST- contrast brain MRI dataset and evaluate on a large heterogeneous brain MRI cohort. The work provides accurate, hallucination-free, generaliz- able and clinically validated framework for 3D MRI reconstruction from highly sparse inputs and enables a clinically viable path towards faster and more patient-friendly MRI imaging.
Prajyot Pyati, Sapna Sachan, Amulya Kumar Mahto +1
May 4, 2026cs.CV

Self-Supervised Spatial And Zero-Shot Angular Super-Resolution by Spatial-Angular Implicit Representation For Rotating-View SNR-Efficient Diffusion MRI

Rotating-view thick-slice acquisition is highly SNR-efficient for mesoscale diffusion MRI (dMRI) but requires numerous rotating views to satisfy Nyquist sampling, resulting in long scan time. We propose a self-supervised Spatial-Angular Implicit Neural Representation (SA-INR) that reconstructs high-resolution dMRI from a single view per diffusion direction, representing a massive acceleration. Our model, an MLP conditioned on a b=0 structural prior and the b-direction via FiLM, is trained end-to-end on the anisotropic input. The framework not only accurately reconstructs the trained b-directions (spatial SR) but also learns a continuous q-space representation, enabling high-fidelity "zero-shot" synthesis of unseen b-directions (angular SR). On simulated data, our method achieved high fidelity for both trained (34.82 dB) and unseen (33.08 dB) directions. Most importantly, the synthesized angular data also improved the quantitative accuracy of downstream DTI model fitting. Our SA-INR framework breaks the classical sampling limits, paving the way for fast, quantitative high-resolution dMRI.
Yinzhe Wu, Hongyu Rui, Fanwen Wang +3
May 2, 2026eess.IV

A Target-Free Harmonization Method for MRI

In MRI, variations in scan parameters, sequence, or hardware can lead to discrepancies in image appearance, even for the same subject. These inconsistencies, known as domain shifts, can hinder image analysis and degrade the performance of deep learning models trained on data from specific target domains. MRI image harmonization aims to address these issues by aligning source domain images to the target domain images while preserving biological information such as anatomical structures. However, most existing harmonization approaches require access to both source and target domain data in training or test time. This dependence induces data sharing between institutions, raising concerns about patient privacy and substantially limiting the harmonization approaches that can be practically deployed in clinical settings. To overcome these limitations, we introduce TgtFreeHarmony, the harmonization framework tailored for target-free scenarios, eliminating the need for target domain data and any data sharing, enabling privacy-preserving harmonization directly within the source institution. Our approach estimates the target domain style by searching the manifold of MRI domain style constructed via a disentanglement-based generator using Bayesian optimization guided by the performance of a downstream task model, which is trained on target domain data. We evaluated our method on the brain tissue segmentation task across multiple institutes and demonstrated that it effectively harmonizes source images into target images, leading to improved downstream task performance. By enabling harmonization without any access to target-domain data, TgtFreeHarmony establishes a new direction of harmonization preserving data privacy that can be realistically deployed within clinical environments.
Minjun Kim, Dong Ju Mun, Hwihun Jeong +4
May 2, 2026cs.CV

Phase-map synthesis from magnitude-only MR images using conditional score-based diffusion models with application in training of accelerated MRI reconstruction models

Accelerated magnetic resonance imaging (MRI) enabled by the training of deep learning (DL)-based image recon. models requires large and diverse raw k-space datasets. In most clinical MRI applications, due to storage and patient privacy concerns, raw k-space data is discarded and magnitude-only images are the only component saved. Consequently, a large portion of the DL-based MRI recon. literature has either relied on small training datasets or has used one of the few available open-source k-space datasets. At the same time, the growing number of anonymized magnitude-only image registries/databases motivates the development of techniques that can use them as training datasets for generalizable DL-based recon. models. Here we propose to address this challenge by employing a generative approach based on conditional score-based diffusion models (SBDMs): given a magnitude-only MR image, it synthesizes a phase map (in the image domain) that realistically corresponds to the magnitude-only image. We evaluate its generative capabilities in a downstream DL-based recon. task whereby a large k-space dataset is generated by combining the SBDM-synthesized phase-maps and the corresponding magnitude-only images, and this k-space dataset is then used to train a DL model for accelerated MRI recon. We compare the performance of the resulting DL model versus those trained according to (a) a naive approach that uses smooth phase, (b) a k-space training dataset generated using synthesized phase maps derived from a generative adversarial network, and (c) the ground truth k-space data. Our results suggest that the DL model trained from SBDM-synthesized k-space data outperforms the other approaches in terms of quantitative metrics as well as qualitatively observed recon. fidelity, i.e., whether the reconstructed images include erroneous or hallucinated features that could adversely impact diagnostic accuracy.
M. Berk Sahin, Dilek Yalcinkaya, Abolfazl Hashemi +1
Apr 25, 2026cs.IT

A Unified Fractional Regularization Framework for Sparse Recovery

We propose a unified fractional regularization framework for sparse signal recovery based on the ℓ1/ℓpq\ell_1/\ell_p^q model. This model generalizes several widely used sparsity-promoting regularizers and provides additional flexibility through the parameters pp and qq. Our main theoretical contribution is the characterization of the equivalence between the first-order stationary points of the ℓ1/ℓpq\ell_1/\ell_p^q formulation and the subtractive ℓ1−αℓp\ell_1-α\ell_p model, thereby offering a unified perspective on these nonconvex regularizers. In addition, we establish a new sufficient recovery condition under the Restricted Isometry Property (RIP), which shows that the proposed framework can provide relaxed recovery guarantees and improved robustness. To solve the resulting nonconvex problem, we develop a majorization--minimization (MM) algorithm and prove its convergence by using the Kurdyka--Łojasiewicz (KL) property. Numerical experiments on sparse recovery problems with different sensing matrices and MRI reconstruction demonstrate that the proposed approach outperforms existing methods in recovery accuracy.
Yinhao Zhao, Haoyu He, Chuanqi Ma +1
Apr 7, 2026physics.med-ph

Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)

Time-resolved volumetric MR imaging that reconstructs a 3D MRI within sub-seconds to resolve deformable motion is essential for motion-adaptive radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a spatiotemporal Gaussian representation-based framework (DREME-GSMR), which enables time-resolved dynamic MRI reconstruction from a pre-treatment 3D MR scan without any prior anatomical/motion model. DREME-GSMR represents a reference MRI volume and a corresponding low-rank motion model (as motion-basis components) using 3D Gaussians, and incorporates a dual-path MLP/CNN motion encoder to estimate temporal motion coefficients of the motion model from raw k-space-derived signals. Furthermore, using the solved motion model, DREME-GSMR can infer motion coefficients directly from new online k-space data, allowing subsequent intra-treatment volumetric MR imaging and motion tracking (real-time imaging). A motion-augmentation strategy is further introduced to improve robustness to unseen motion patterns during real-time imaging. DREME-GSMR was evaluated on the XCAT digital phantom, a physical motion phantom, and MR-LINAC datasets acquired from 6 healthy volunteers and 20 patients (with independent sequential scans for cross-evaluation). DREME-GSMR reconstructs MRIs of a ~400ms temporal resolution, with an inference time of ~10ms/volume. In XCAT experiments, DREME-GSMR achieved mean(s.d.) SSIM, tumor center-of-mass-error(COME), and DSC of 0.92(0.01)/0.91(0.02), 0.50(0.15)/0.65(0.19) mm, and 0.92(0.02)/0.92(0.03) for dynamic reconstruction/real-time imaging. For the physical phantom, the mean target COME was 1.19(0.94)/1.40(1.15) mm for dynamic/real-time imaging, while for volunteers and patients, the mean liver COME for real-time imaging was 1.31(0.82) and 0.96(0.64) mm, respectively.
Jiacheng Xie, Hua-Chieh Shao, Can Wu +7
Mar 10, 2026cs.CV

UniField: A Unified Field-Aware MRI Enhancement Framework

Magnetic Resonance Imaging (MRI) field-strength enhancement holds immense value for both clinical diagnostics and advanced research. However, existing methods typically focus on isolated enhancement tasks, such as specific 64mT-to-3T or 3T-to-7T transitions using limited subject cohorts, thereby failing to exploit the shared degradation patterns inherent across different field strengths and severely restricting model generalization. To address this challenge, we propose \methodname, a unified framework integrating multiple modalities and enhancement tasks to mutually promote representation learning by exploiting these shared degradation characteristics. Specifically, our main contributions are threefold. Firstly, to overcome MRI data scarcity and capture continuous anatomical structures, \methodname departs from conventional methods that treat 3D MRI volumes as independent 2D slices. Instead, we directly exploit comprehensive 3D volumetric information by leveraging pre-trained 3D foundation models, thereby embedding generalized and robust structural representations to significantly boost enhancement performance. In addition, to mitigate the spectral bias of mainstream flow-matching models that often over-smooth high-frequency details, we explicitly incorporate the physical mechanisms of magnetic fields to introduce a Field-Aware Spectral Rectification Mechanism (FASRM), tailoring customized spectral corrections to distinct field strengths. Finally, to resolve the fundamental data bottleneck, we organize and publicly release a comprehensive paired multi-field MRI dataset, which is an order of magnitude larger than existing datasets. Extensive experiments demonstrate our method's superiority over state-of-the-art approaches, achieving an average improvement of approximately 1.81 dB in PSNR and 9.47% in SSIM. Codes and datasets are available at: https://github.com/linyiyang98/UniField.
Yiyang Lin, Chenhui Wang, Zhihao Peng +1
Mar 4, 2026cs.CV

MPFlow: Multi-modal Posterior-Guided Flow Matching for Zero-Shot MRI Reconstruction

Zero-shot MRI reconstruction relies on generative priors, but single-modality unconditional priors produce hallucinations under severe ill-posedness. In many clinical workflows, complementary MRI acquisitions (e.g. high-quality structural scans) are routinely available, yet existing reconstruction methods lack mechanisms to leverage this additional information. We propose MPFlow, a zero-shot multi-modal reconstruction framework built on rectified flow that incorporates auxiliary MRI modalities at inference time without retraining the generative prior to improve anatomical fidelity. Cross-modal guidance is enabled by our proposed self-supervised pretraining strategy, Patch-level Multi-modal MR Image Pretraining (PAMRI), which learns shared representations across modalities. Sampling is jointly guided by data consistency and cross-modal feature alignment using pre-trained PAMRI, systematically suppressing intrinsic and extrinsic hallucinations. Extensive experiments on HCP and BraTS show that MPFlow matches diffusion baselines on image quality using only 20% of sampling steps while reducing tumor hallucinations by more than 15% (segmentation dice score). This demonstrates that cross-modal guidance enables more reliable and efficient zero-shot MRI reconstruction.
Seunghoi Kim, Chen Jin, Henry F. J. Tregidgo +2
Jan 19, 2026eess.IV

Pixelwise Uncertainty Quantification of Accelerated MRI Reconstruction

Parallel imaging techniques reduce magnetic resonance imaging (MRI) scan time but image quality degrades as the acceleration factor increases. In clinical practice, conservative acceleration factors are chosen because no mechanism exists to automatically assess the diagnostic quality of undersampled reconstructions. This work introduces a general framework for pixel-wise uncertainty quantification in parallel MRI reconstructions, enabling automatic identification of unreliable regions without access to any ground-truth reference image. Our method integrates conformal quantile regression with image reconstruction methods to estimate statistically rigorous pixel-wise uncertainty intervals. We trained and evaluated our model on Cartesian undersampled brain and knee data obtained from the fastMRI dataset using acceleration factors ranging from 2 to 10. An end-to-end Variational Network was used for image reconstruction. Quantitative experiments demonstrate strong agreement between predicted uncertainty maps and true reconstruction error. Using our method, the corresponding Pearson correlation coefficient was higher than 90% at acceleration levels at and above four-fold; whereas it dropped to less than 70% when the uncertainty was computed using a simpler a heuristic notion (magnitude of the residual). Qualitative examples further show the uncertainty maps based on quantile regression capture the magnitude and spatial distribution of reconstruction errors across acceleration factors, with regions of elevated uncertainty aligning with pathologies and artifacts. The proposed framework enables evaluation of reconstruction quality without access to fully-sampled ground-truth reference images. It represents a step toward adaptive MRI acquisition protocols that may be able to dynamically balance scan time and diagnostic reliability.
Ilias I. Giannakopoulos, Lokesh B Gautham Muthukumar, Yvonne W. Lui +1
Jan 17, 2026eess.SP

Accelerated MR Elastography Using Learned Neural Network Representation

To develop a deep-learning method for achieving fast high-resolution MR elastography from highly undersampled data without the need of high-quality training dataset. We first framed the deep neural network representation as a nonlinear extension of the linear subspace model, then used it to represent and reconstruct MRE image repetitions from undersampled k-space data. The network weights were learned using a multi-level k-space consistent loss. To further enhance reconstruction quality, phase-contrast specific magnitude and phase priors were incorporated, including the similarity of anatomical structures and smoothness of wave-induced harmonic displacement. Experiments were conducted using both 3D gradient-echo spiral and multi-slice spin-echo spiral MRE datasets. Compared to the conventional linear subspace-based approaches, the nonlinear network representation method was able to produce superior image reconstruction with suppressed noise and artifacts from a single in-plane spiral arm per MRE repetition (e.g., 2mm isotropic resolution in 1 min with a total R=10), yielding comparable stiffness estimation to the fully sampled data. This work demonstrated the feasibility of using deep network representations to model and reconstruct MRE images from highly-undersampled data, a nonlinear extension of the subspace-based approaches.
Xi Peng