Medical Imaging Foundation Models

Momentum

24 papers in the last four weeks, up 167% on the four weeks before. 0.2% of all new papers.

Jul 13Week of Sep 28

Latest papers 150

Jun 11, 2026cs.CV

Masked and Predictive Self-Supervised Foundation Models for 3D Brain MRI

Self-supervised foundation models have shown strong promise in medical imaging. However, existing MRI foundation-model studies have primarily emphasized segmentation and dense prediction tasks, while systematic investigation of self-supervised foundation models for MRI-based disease detection remains limited. In this work, we investigate two major self-supervised pretraining paradigms for MRI-based disease detection: reconstruction-based learning via Masked Autoencoders (MAE) and predictive representation learning via Joint Embedding Predictive Architectures (JEPA). We study the role of auxiliary objectives by introducing a novel spectral-domain reconstruction loss for MAE to enhance sensitivity to fine-grained anatomical structure, and by integrating variance--covariance regularization (VCR) within our JEPA framework to encourage decorrelated latent representations. Our models are pretrained on heterogeneous single-contrast MRI volumes in a contrast-agnostic setting, without modality concatenation. Across five downstream disease detection tasks, our results highlight the importance of self-supervised objective design for medical foundation model pretraining, demonstrating that the downstream benefit of each objective is determined by its relevance to the task's structure. Specifically, spectral regularization yields the largest improvements when the downstream discriminative signal is characterized by strong high-frequency anatomical structures, while covariance regularization is most beneficial when discriminative information spans multiple decorrelated feature dimensions. MAE with spectral-domain supervision consistently achieves superior downstream performance for MRI-based disease detection. These findings suggest that self-supervised objectives in medical imaging encode specific biases, and their downstream benefit is fundamentally conditioned on the task's structure.
Jun 11, 2026cs.AI

Hallucination in Medical Imaging AI: A Cross-Modality Analytical Framework for Taxonomy, Detection, and Mitigation under Regulatory Constraints

AI systems are being deployed across medical imaging faster than their failure modes are understood. At this point in time, the failure of greatest clinical concern is hallucination: clinically plausible but factually incorrect outputs, including fabricated anatomical structures, missed findings, incorrect laterality, and invented measurements in generated reports, with direct consequences, for example, for biopsy decisions, staging, and treatment planning. This structured narrative synthesizes peer-reviewed studies, benchmark datasets, and FDA regulatory guidance across five imaging modalities to produce a cross-modality analysis of hallucination taxonomy, etiology, detection, and mitigation. Specifically, we address three questions in this study: (1) how can existing taxonomies be unified across modalities?, (2) how do medical-specialized foundation models hallucinate less than general-purpose ones?, and (3) which mitigation strategies are effective and compatible with FDA lifecycle oversight? We note that three taxonomic frameworks together cover the imaging pipeline in a way no single framework does alone. We also highlight that general-purpose foundation models outperform medical-specialized models on hallucination-specific benchmarks, indicating that narrow domain fine-tuning can introduce overfitting-induced confabulation. At the same time, the oversight of radiologists remains essential; for instance, a very high percentage of of AI-generated flags required expert correction before clinical use. Physics-informed architectural constraints, Chain-of-Thought prompting, and human-in-the-loop safeguards each address different failure modes and is effective when combined. All findings are mapped to the FDA's Total Product Lifecycle and Predetermined Change Control Plan frameworks, which treat hallucination management as a lifecycle obligation rather than a pre-deployment checklist.
Jun 10, 2026cs.CV

Frozen Foundation-Model Embeddings Discard Small-Lesion Signal in Chest Radiography: Implications for Pre-Deployment Evaluation

Frozen vision-transformer (ViT) foundation-model embeddings increasingly serve as the substrate for downstream chest-radiography (CXR) pipelines, yet where small-scale, low-contrast signal is retained or lost in the frozen forward pass has not been systematically quantified across architectures, pretraining domains, and objectives. We probed five frozen ViTs (RAD-DINO, DINOv2-B/14, DINOv3 ViT-7B, BiomedCLIP, MedSigLIP) and a frozen DINO-pretrained ResNet-50 architectural control across three large CXR cohorts (NIH-CXR14, MIMIC-CXR, Emory-CXR; aggregate pool n=492,724) and ChestX-Det10 (n=3,543; 1,462 small-lesion bounding boxes across Calcification, Nodule, Mass). Each model was evaluated with a small-scale-perturbation panel and a region-aware bounding-box-stratified probe on real lesions, comparing three pooling modes from the same forward pass: classification token (CLS), patch-mean (mean over all final-layer patch tokens), and bounding-box-restricted patch-local. On the perturbation panel, CLS embeddings sat at the chance floor (area under the ROC curve [AUC] 0.500-0.524); patch-mean was indistinguishable from CLS on iso-blur and reticular-fine cells but rose with CLS on larger directional-blur footprints, while disease AUC on globally decided tasks ranged 0.642-0.913. Patch-local probes recovered AUC ~1.0 from the same forward pass (per-model mean improvement +0.412 to +0.488); the ResNet-50 control reproduced the chance floor. On ChestX-Det10, image-level CLS classification showed within-class small-versus-large stratum gaps up to +0.243 AUC; bounding-box-level patch-local pooling on the same forward pass recovered AUC >= 0.899 on every (model x class) cell. Frozen ViT embeddings silently suppress small-scale signal at the global-aggregation step; the signal is recoverable from patch tokens conditional on a region of interest.
Jun 9, 2026eess.IV

FlexiBrain: Resolution-Agnostic Voxel-Level Encoding for Native fMRI

The success of large-scale deep learning models in neuroscience is fundamentally constrained by severe data heterogeneity. Native fMRI data aggregated from diverse sources exhibit substantial variation in both spatial and temporal resolutions. Consequently, most existing frameworks rely on lengthy, rigid preprocessing pipelines that enforce uniformity across datasets. This practice introduces two critical limitations: (1) potential degradation of subject-specific anatomical information; (2) significant computational overhead, often requiring hours of processing per subject. Here, we propose FlexiBrain, a resolution-agnostic voxel-level encoding framework for native fMRI based on Mamba-JEPA. FlexiBrain defines patch sizes in real-world physical units and employs a dynamic patch resizing, thereby bypassing destructive spatial standardization while enabling direct ingestion of data in native space. We instantiate the framework using an efficient Mamba-JEPA backbone to model high-dimensional 4D fMRI signals. Across five diverse downstream neuroscience tasks, FlexiBrain consistently outperforms recent state-of-the-art methods, achieving gains of up to 12 percentage points without external data augmentation. Importantly, FlexiBrain functions as a seamless plug-in module, substantially reducing preprocessing costs and accelerating the development of robust voxel-level fMRI foundation models. Code is available at https://github.com/OneMore1/FlexiBrain.
Jun 8, 2026cs.CV

A multi-agent system for spine MRI report generation from multi-sequence imaging

Spinal pathology is a leading cause of pain and disability worldwide. Spine MRI is central to clinical evaluation, yet its interpretation remains complex and time-consuming, requiring integration of information across multiple imaging sequences and anatomical regions. Despite recent advances in automated MRI analysis, effectively combining multi-sequence data while preserving sequence-specific diagnostic information remains an open challenge. Here we present SpineAgent, a multi-agent framework for spine MRI report generation built upon a multi-sequence foundation model trained on routine clinical data from 32,047 patients and 453,683 MRI series, comprising a total of 13,441,191 MRI slices. To accommodate diverse modalities of sequences, we first pre-train two DINOv3-based encoders separately on T1- and T2-weighted sequences. We then introduce a continual training strategy that learns a synthesizer to embed images of other sequences using the T1 and T2 encoders, producing patient-level embedding that integrates various signals across MRI sequences. Using these embeddings, SpineAgent achieves state-of-the-art performance, and demonstrates strong generalizability under cross-manufacturer and cross-cohort evaluation. Beyond classification, SpineAgent enables pathology localization by identifying findings-relevant slices and segmenting pathological regions. It also supports multimodal image-report retrieval, providing a solid foundation for scalable and explainable MRI report generation. We further integrate these validated capabilities of SpineAgent into 37 specialized agents. Finally, we incorporate their outputs as structured tokens within a Medical Report Agent trained end-to-end for report generation. Through both automated metrics and expert evaluation by five radiologists, SpineAgent achieves leading performance in spine MRI report generation.
Jun 6, 2026cs.CV

Self-Supervised Vision Transformers for CBCT-Based Detection of Temporomandibular Joint Osteoarthritis

Temporomandibular joint osteoarthritis (TMJ OA) is a prevalent degenerative condition whose osseous changes are often subtle on cone-beam CT (CBCT), making automated detection challenging. We study how well the DINO family of self-supervised vision transformers -- DINOv1, DINOv2, DINOv2+reg, and RAD-DINO (a radiology-pretrained variant) -- transfers to CBCT, asking how much backbone adaptation is needed and of what kind. We propose a simple slice-based pipeline using Vision Transformer (ViT) backbones: axial CBCT slices are encoded per-slice by a frozen or partially adapted ViT and aggregated via attention-based multiple instance learning (MIL) for patient-level binary OA/Normal classification. Through systematic ablation across unfreezing strategies and aggregation designs on a multi-source CBCT dataset, we find that partial unfreezing of the final two transformer blocks is the decisive factor, improving AUC from 0.671 (fully frozen DINOv2) to 0.902. This outperforms DINOv1 (0.867), DINOv2+reg (0.774), and a supervised ImageNet ViT-B/16 baseline (0.843). Our results provide practical guidance for adapting DINO-family foundation models in low-data medical imaging settings, showing that adaptation strategy is a stronger driver of performance than backbone choice alone.
Jun 6, 2026cs.CV

How Much MRI Preprocessing Is Enough? A Cost-Utility Study for Brain MRI Foundation Models

MRI preprocessing defines the input distribution seen by brain MRI foundation models, yet it is usually treated as routine data cleaning rather than a modeling choice. We ask how much preprocessing is worth its computational cost for self-supervised 3D MRI pretraining. Keeping the corpus, 3D ViT backbone, masking protocol, and downstream evaluations fixed, we compare a graded P0-P7 preprocessing spectrum for masked autoencoding (MAE) and joint-embedding predictive learning (JEPA) on 20,000 heterogeneous brain MRI volumes, then transfer the encoders to IDH prediction, MCI classification, brain age regression, and GLI/PED tumor segmentation. The results do not support a simple "more is better" rule. P0/P1 are numerically unstable, making P2 the lowest-cost feasible level; beyond P2, choosing the best feasible preprocessing level improves aggregate utility by only 3.4 percentage points for MAE and 1.8 percentage points for JEPA, with most paired gains statistically unresolved. Stronger preprocessing is beneficial only in selected regimes: IDH improves modestly, AGE and GLI/PED are often near or best at P2, and MCI shows the clearest empirical P7 gain. Cross-level MCI transfer further shows that much of the P7 advantage can be recovered by applying stronger preprocessing downstream, without requiring P7 throughout pretraining. These findings recast MRI preprocessing as a downstream-aware cost-utility decision rather than a default escalation pipeline. Code is available at https://github.com/PangJiangShuan/PreBrain.
Jun 5, 2026cs.CV

DALE-CT: Depth-Aware Foundation Models for Computed Tomography

Recent breakthroughs in self-supervised learning (SSL), such as the Latent-Euclidean Joint-Embedding Predictive Architecture (LeJEPA), alongside successes in integrating visual encoders with language models, have driven the demand for adaptable, high-capacity vision encoders in Computed Tomography (CT). In this work, we explore 2D slice-based architectures as a flexible alternative to native 3D models for processing volumetric CT data. Using the CT-RATE dataset, we trained DALE-CT (Depth-Aware Latent-Euclidean Computed Tomography), a 2D model family built entirely from scratch using LeJEPA, and compared its performance against a continually pre-trained DINOv2 baseline. To enhance representation quality, we developed a novel 3D depth-aware pre-training strategy anchored by dense auxiliary supervision from both automated anatomical masks and human-annotated abnormalities. Under linear probe evaluation with Multiple Instance Learning (MIL) for multi-abnormality detection, the frozen backbone of this dual-supervised model (DALE-CT-2S) achieves a Macro AUROC of 0.833. This performance demonstrates near-parity with state-of-the-art 3D vision-language models, achieved entirely from scratch with significantly less data and no textual supervision. To ensure reproducibility, all training code, evaluation scripts, and model weights have been made publicly available.
Jun 3, 2026eess.IV

Tractogram foundation model

Diffusion MRI (dMRI) tractography is the only noninvasive approach for mapping white-matter pathways in the living human brain. It represents each brain as a tractogram: a large, unordered set of three-dimensional streamlines that includes information about both local streamline geometry and whole-brain anatomical organization. This structure makes tractograms a natural but challenging target for representation learning. Existing methods treat streamline classification and subject-level prediction as separate problems: streamline classifiers focus on geometric patterns, whereas subject-level prediction often depends on hand-crafted features. As a result, current methods do not learn reusable representations that connect streamline anatomy with whole-brain inter-subject variation. Here we introduce TractFM, a tractogram foundation model that learns reusable representations directly from whole-brain streamline sets. TractFM combines a local streamline encoder with a permutation-equivariant tractogram encoder, allowing all streamlines from a subject to be contextualized jointly in a single forward pass. Pretraining on dense anatomical tract parcellation, i.e., assigning anatomical labels to individual streamlines, yields two complementary representations: contextualized streamline-level embeddings for tract parcellation and compact subject-level descriptors for downstream prediction of subject phenotypes. Across three tractography algorithms and five dMRI datasets, TractFM transfers to both streamline-level and subject-level tasks. Its frozen representations achieve accurate tract parcellation and predict age and sex across independent datasets. These results show that whole-brain geometric context, learned once, can generalize across tractography pipelines, datasets, and prediction tasks.
Jun 3, 2026cs.CV

Enhancing MedSAM with a Lightweight Box Predictor for Medical Image Segmentation

Semantic segmentation in medical imaging is a critical yet challenging task due to data scarcity and high variability across modalities. While foundation models like the Segment Anything Model (SAM) show promise, they often struggle with medical images without specific adaptation. Moreover, point prompts, despite being the most natural form of user interaction, provide insufficient spatial context for reliable segmentation, particularly when target structures are irregular or poorly contrasted. In this paper, we propose an enhanced segmentation framework that integrates a lightweight Box Predictor module into the MedSAM architecture. The Box Predictor estimates an approximate bounding box from a single user click using localized image embedding features, providing spatial guidance that reduces the ambiguity of point prompts, while introducing only 1.6M additional parameters and negligible inference overhead. We introduce a two-stage training pipeline where the Box Predictor is trained independently before being integrated into MedSAM. To validate the generalization capability of our method, we conduct extensive evaluations on four diverse datasets (FLARE22, BRISC, BUSI, LungSegDB) spanning distinct imaging modalities, including CT, MRI, and Ultrasound. Our method improves segmentation accuracy and robustness across varied anatomical structures and imaging domains, achieving Dice scores of 0.89 (BUSI), 0.93 (FLARE22), 0.88 (BRISC), and 0.98 (LungSegDB). Code is available at https://github.com/Amirhosseinmovahedi/MedSAM-BoxPredictor
Jun 2, 2026cs.CV

CoralBay: A Self-Supervised CT Foundation Model

Self-supervised learning has enabled large-scale pre-training on 2D natural images, producing general-purpose visual representations that transfer effectively across tasks. However, many medical imaging modalities, such as CT scans, are inherently three-dimensional and differ fundamentally from natural images in both structure and semantics. Volumetric modalities capture spatial continuity, organ anatomy, and intensity-based tissue properties (e.g., Hounsfield Units), which are not adequately modeled by 2D pre-training. To bridge this gap, we introduce CoralBay, a self-distillation framework that extends DINO by using a hierarchical 3D Swin backbone and applying self-distillation to concatenated multi-scale features, enabling data-efficient self-supervised learning of rich spatial representations that encode both global semantics and fine-grained local structure. As a result, CoralBay transfers effectively to a wide range of downstream radiological tasks, demonstrating strong and consistent performance across diverse anatomical targets. In addition, we contribute to the open-source \eva framework by introducing a public, reproducible 3D radiology leaderboard that unifies multiple datasets and establishes a standardized benchmark for evaluating volumetric representation learning methods.
Jun 1, 2026cs.AI

Large AI Models in Dental Healthcare: From General-Purpose Systems to Domain-Specific Foundation Models

Background: Oral diseases affect nearly 3.5 billion people worldwide, yet the comparative clinical potential of large-scale AI models in dentistry remains poorly understood. Three distinct model categories have emerged: language-generative models, discriminative vision foundation models, and dental-specific foundation models, with no unified review examining their relationships and collective limitations. Methods: Following PRISMA-ScR guidelines, we systematically searched four databases (PubMed, Google Scholar, Scopus, arXiv), screened independently by two reviewers. After applying inclusion/exclusion criteria, 97 studies (2020-2026) were included. We propose a two-dimensional classification framework organizing models by architectural paradigm and dental specialization degree. Results: Language-generative models excel at text-based tasks (clinical reasoning, licensing exams, patient communication) but show inconsistent performance on image-dependent diagnostics. Adapted SAM and CLIP variants achieve strong tooth segmentation and lesion detection results. Dental-specific models (DentVFM, DentVLM, OralGPT) demonstrate strongest performance on complex multimodal tasks. Integrated pipelines consistently outperform single-model approaches. A data asymmetry is observed: dental-specific pretraining concentrates almost entirely in the vision domain, reflecting scarce large-scale dental text corpora. Conclusions: General-purpose and dental-specific models play complementary roles; the most effective systems combine both within structured pipelines. Safe autonomous deployment requires resolving three persistent barriers: hallucination in generative models, limited annotated dental datasets, and absent standardized clinical evaluation benchmarks.
May 29, 2026q-bio.NC

The Variance Brain Foundation Models Forgot: Third-Order Statistics Predict Cognition Where Billion-Parameter Models Fail

Brain foundation models (BFMs) are self-supervised Transformers pretrained on fMRI data. We posit that these models should capture each subject's cognitive performance from their fMRI signal. Yet across three state-of-the-art BFMs and every readout we test, they predict cognition worse than a linear regression from the ∼\sim80K parameters of the functional connectivity matrix (FC). The gap widens with scale: BrainLM's 650M model predicts cognition worse than its 111M. We attribute this to a \textbf{variance allocation problem}: BFM pretraining captures the variance components that dominate fMRI but not the higher-order structure that predicts cognition. Our per-cumulant analysis of the reconstructed signal shows that the second-order covariance is partially preserved, while the third-order co-skewness tensor is largely destroyed. To recover what BFMs lose, we design a linear pipeline that projects the fMRI signal into the subspace that best preserves its co-skewness and computes FC there. This \textbf{exceeds raw FC and every pretrained BFM} on every dataset and parcellation we test, outperforming prior state-of-the-art under controlled evaluation \textbf{with no pretraining and no GPU}. We \textbf{recover the raw-FC ceiling on BrainLM's forward pass} by finetuning with a loss targeted at this same subspace. This shows that the bottleneck is the pretraining objective, not the architecture or the model size.
May 29, 2026cs.CV

Astra: a generalizable report generation foundation model for 3D computed tomography

Interpreting computed tomography (CT) requires review of hundreds of volumetric slices and remains time-intensive and expertise-dependent. Automated CT report generation offers a promising route to improving clinical efficiency, yet the field still lacks a generalizable CT report generation foundation model that supports multi-region reporting and remains robust across external real-world cohorts. Intrinsic inconsistencies in reporting style and diagnostic terminology across cohorts make naive joint training difficult. Here we present Astra, a generalizable CT report generation foundation model developed on 90,678 thoracoabdominal CT-report pairs collected from five sites worldwide (CTRgDB), comprising 353,671 abnormalities spanning eight organ systems. By harmonizing report style and further refining diagnostic consistency via reinforcement learning, Astra achieves style-consistent and diagnostically accurate report generation across diverse anatomical regions and institutions. Evaluated on CTRgDB and six external cohorts, Astra achieves state-of-the-art performance with a 38.4% average improvement in fine-grained diagnostic metrics (P<0.001). Deployed at external clinical sites without any site-specific fine-tuning, Astra accelerated chest report drafting by 29.6% and improved abdominal report completeness by 11.3% among junior and mid-level radiologists (P<0.001). Furthermore, Astra demonstrates broad utility as a foundation for CT AI development, improving downstream diagnostic performance and scaling vision-language pretrain through high-quality report synthesis. Overall, Astra serves as a broadly accessible clinical assistant and a pivotal infrastructure for the next generation of AI-powered healthcare. The code for Astra is publicly available at https://github.com/zh-Wang-Med/Astra.
May 29, 2026eess.IV

A physics-informed foundation model for quantitative diffusion MRI

Understanding the human brain requires access to its microscopic tissue architecture. Diffusion magnetic resonance imaging (MRI) provides the only noninvasive window into whole-brain microstructure in vivo, yet reliable quantitative mapping remains confined to specialized research settings requiring dense sampling and optimized acquisition protocols. To address this gap, we present a physics-informed generative microstructure network (PIGMENT) that learns a universal generative prior of human brain microstructure and adapts it zero-shot to each participant's measured data to recover subject-specific maps. Trained on 11375 scans spanning multiple sites, vendors, and field strengths, PIGMENT enabled reliable quantitative mapping for tensor, kurtosis, and NODDI models across external datasets from five independent centers. It remains effective where conventional fitting becomes unreliable, recovering meaningful maps from extremely sparse acquisitions while supporting downstream tractography and structural connectivity mapping. PIGMENT estimates demonstrated strong biological validity, preserving submillimeter cortical microarchitectural patterns and early-childhood white matter developmental trajectories from 10-fold accelerated scans. Furthermore, PIGMENT enables reliable quantitative tensor mapping on cost-efficient low-field systems and the extraction of tumor-related biomarkers using ultra-fast clinical protocols. Together, these results establish PIGMENT as a physics-informed foundation model that extends quantitative diffusion MRI into regimes traditionally too sparse, heterogeneous, or clinically constrained for reliable analysis.
May 29, 2026cs.CV

Foundation VAEs for 3D CT Reconstruction, Augmentation, and Generation

Variational autoencoders (VAEs) compress high resolution CT volumes into compact latents while preserving clinically relevant structure. However, training CT-specific VAEs from scratch or heavily fine-tuning them incurs substantial computational and engineering cost, and often degrades under heterogeneous scanners, protocols, and diseases. This paper makes a progressive stride toward training-free medical VAEs by leveraging a critical observation: a single Foundation VAE, pretrained at scale on natural images and videos, can serve as a unified interface for CT Reconstruction, Augmentation, and Generation. With both encoder and decoder frozen, the Foundation VAE reconstructs CT volumes with preserved anatomy while suppressing acquisition noise; training segmentation models on these reconstructions improves surface accuracy by 3.9% NSD on average for pancreatic tumor and lung tumor. Within the same Foundation VAE latent space, a conditional latent diffusion model achieves 3.9% lower average FVD with 36.2% higher CT CLIP score, and improves multi-disease generation faithfulness across 18 types by 2.76% AUC. These results demonstrate Foundation VAEs as a practical interface for scalable CT representation reuse and faithful CT generation. Our code and demo are available at https://github.com/qic999/Foundation-VAE.
May 27, 2026eess.IV

Benchmarking Ultrasound Foundation Models for Fetal Plane Classification

Ultrasound is widely used in obstetric care due to its safety, accessibility, and real-time imaging. However, interpretation remains operator-dependent and susceptible to noise and artifacts. Deep learning models have shown strong performance to solve these problem, but they typically require large annotated datasets that are difficult to obtain in clinical ultrasound. Foundation models (FMs) offer an alternative, using a large number of ultrasound images to learn transferable representations that can generalize with limited labeled data. This work presents a comprehensive benchmark of ultrasound-specific FMs for fetal plane classification. We evaluated four ultrasound FMs (USFM, MOFO, UltraSAM, FetalCLIP) against two CNN baselines (ResNet50, EfficientNet-V2) and a ViT (DINOv3) pretrained on natural images. We trained all models under two complementary settings: full fine-tuning and linear probing with a frozen encoder. All models were trained using 5-fold patient-level cross-validation on a Spanish fetal ultrasound dataset and tested on both in-domain data and an external African cohort to assess cross-population generalization. We found that FetalCLIP achieved the best results in the linear probing setting (F1 = 0.9261 for in-domain, F1 = 0.9731 for out-of-domain), while USFM performed best in the full fine-tuning setting (F1 = 0.9476 for in-domain, F1 = 0.9515 for out-of-domain). MOFO and UltraSAM degraded most in both settings, underperforming natural image pretrained models in some cases. These findings highlight how the choice of pretrained model strongly affects fetal plane classification performance, since different pretraining objectives lead to different levels of transferability.
May 25, 2026cs.CV

EchoPilot: Training-Free Ultrasound Video Segmentation via Scale-Space Semantic Prompting and Reliability-Gated Memory

Ultrasound video segmentation is clinically valuable yet difficult due to speckle noise, weak boundaries, and rapid anatomical deformation. Recent promptable foundation models enable point-guided segmentation, but their direct deployment in ultrasound remains unreliable: a single point provides insufficient spatial context to resolve scale ambiguity, and greedy memory updates amplify early errors into severe temporal drift. We present EchoPilot, a training-free framework for ultrasound video segmentation under sparse first-frame interaction, requiring only a single point click and an anatomical category name. EchoPilot orchestrates a frozen medical vision-language model (VLM) for semantic localization, a vision foundation model (VFM) for dense geometric feature extraction, and a promptable video segmentor for mask prediction and propagation. To resolve initialization ambiguity, we propose Scale-Space Semantic Prompting, which first selects an optimal contextual view via a parameter-free S.E.E.D. (Semantic Energy-Entropy Density) criterion, and then synthesizes geometrically precise auxiliary point prompts from dense foundation features without additional user interaction. To reduce propagation drift, a Reliability-Gated Memory update is further introduced to selectively freeze the segmentor's memory bank under uncertain predictions, preventing error accumulation. We also contribute the first dynamic fetal placenta ultrasound video segmentation dataset with 671 annotated frames. Across three ultrasound video datasets, EchoPilot achieves state-of-the-art performance under the sparse-interactive setting, consistently outperforming training-free baselines and finetuned specialists.
May 21, 2026cs.CV

Universal CT Representations from Anatomy to Disease Phenotype through Agglomerative Pretraining

Computed tomography (CT) is a central to three-dimensional medical imaging, yet CT-based artificial intelligence remains fragmented across task-specific models for segmentation, classification, registration, and report analysis. Here we present FlexiCT, a family of CT foundation models trained by agglomerative continual pretraining on 266,227 CT volumes from 56 publicly available datasets, forming a large-scale public resource for CT representation learning. FlexiCT uses agglomerative pretraining across three stages: two-dimensional axial pretraining, three-dimensional anatomical pretraining and report-guided semantic alignment. This training strategy supports slice-level, volume-level and vision-language analysis. Across five downstream task families (segmentation, classification, registration, vision-language understanding and clinical retrieval), FlexiCT matches or exceeds prior task-specific approaches on multiple benchmarks. Its embeddings further organize CT scans along gradients associated with various tumor stages, suggesting that CT foundation models can capture imaging features relevant to disease phenotype characterization. Project page and code are available at: https://ricklisz.github.io/flexict.github.io and https://github.com/ricklisz/FlexiCT.
May 21, 2026cs.CV

Learning Emergent Modular Representations in Multi-modality Medical Vision Foundation Models

Multi-modality medical vision (MV) foundation models (FM) are fundamentally challenged by pronounced Non-IID feature statistics across heterogeneous imaging modalities. Monolithic self-supervised optimization on such data induces conflicting gradients, driving representations to collapse toward modality-dominant shortcuts. This work reframes this failure as an imbalance between specialization and coordination in emergent modularity, and proposes Director-Experts (DEX), a modular network that explicitly regulates these dynamics in stacked modules. Each DEX module comprises a pool of experts, dynamically adapted by our image-wise activation strategy, autonomously specializing in modality-dominant statistics, together with a director, updated via our group exponential moving average, which distills multi-expert knowledge into a shared space for semantic integration across modalities, thus driving the emergence of modular representations. We curate a new benchmark, Medical Vision Universe, over 4 million images across 10 modalities, which provides a FM-level pre-training with the broadest coverage of distinct imaging modalities to our DEX. Extensive evaluations on 26 downstream tasks demonstrate improved optimization behavior and transferability, indicating DEX as a principled step toward general-purpose multi-modality medical AI. Our code and dataset will be opened at https://github.com/YutingHe-list/DEX.
May 20, 2026eess.IV

An Open Multi-Center Whole-Body FDG PET/CT Foundation Model for Tumor Segmentation

The synergistic interpretation of anatomical information from computed tomography (CT) and metabolic information from positron emission tomography (PET) is important to oncologic imaging. However, existing deep learning methods for PET/CT remain largely task-specific, are often trained on single-center cohorts, or adopt dual-branch fusion schemes that delay cross-modal interaction and underutilize early spatial correspondence between PET and CT. To address these limitations, we present an open-source, multi-center, whole-body FDG PET/CT foundation model utilizing 4,997 harmonized scans from four public datasets. Our framework employs hierarchical UNet-shaped backbones with early channel-wise concatenation, enabling anatomical and metabolic features to interact from the first embedding layer onward. We further introduce a masked autoencoding objective based on zero-mean imputation, combined with a weighted global reconstruction loss. This design avoids non-physical intensity discontinuities at masked-region boundaries that arise from learnable mask tokens. On downstream AutoPET lesion segmentation, the proposed models demonstrate strong label efficiency: with only 10% of the labeled training data, they achieve performance comparable to models trained from scratch on the full dataset. Under extreme 5-shot linear probing, joint PET/CT pretraining also achieves higher Dice scores than separated-modality pretraining. This multi-center foundation model demonstrates label efficiency and cross-modality representation learning for PET/CT tumor segmentation. It provides a robust, open-source basis for advancing automated oncologic imaging, significantly reducing the need for large-scale manual annotations in clinical practice.
May 19, 2026cs.CV

Synergistic Foundation Models for Semi-Supervised Fetal Cardiac Ultrasound Analysis: SAM-Med2D Boundary Refinement and DINOv3 Semantic Enhancement

We present a semi-supervised framework for joint segmentation and classification of fetal cardiac ultrasound images. Built upon the EchoCare multi-task backbone, our method integrates SAM-Med2D for boundary refinement and leverages DINOv3 to enhance pseudo-label quality. We introduce view-specific hard masking along with a two-stage optimization strategy: an EMA phase to consolidate segmentation capabilities, followed by a Classification Fine-Tuning phase that freezes segmentation parameters and resets the classification head to recover classification performance without compromising segmentation gains. Evaluated on the FETUS 2026 leaderboard, our method achieves a Dice Similarity Coefficient at 79.99%, Normalized Surface Distance at 61.62%, and F1-score at 41.20%, validating the effectiveness of our approach for prenatal congenital heart disease screening. Source code is publicly available at: https://github.com/2826056177/zcst_fetus2026.
May 13, 2026cs.CV

VoxCor: Training-Free Volumetric Features for Multimodal Voxel Correspondence

Cross-modal 3D medical image analysis requires voxelwise representations that remain anatomically consistent across imaging contrasts, scanners, and acquisition protocols. Recent work has shown that frozen 2D Vision Transformer (ViT) foundation models can support such representations, but typical pipelines extract features along a single anatomical axis and adapt those features inside a registration solver for one image pair at a time, leaving complementary viewing directions unused and producing representations that do not transfer to new volumes. We introduce VoxCor, a training-free fit--transform method for reusable volumetric feature representations from frozen 2D ViT foundation models. During an offline fitting phase, VoxCor combines triplanar ViT inference with a compact closed-form weighted partial least squares (WPLS) projection that uses fitting-time voxel correspondences to select modality-stable anatomical directions in the triplanar feature space. At transform time, new volumes are mapped by triplanar ViT inference and linear projection alone, without fine-tuning or registration. Voxel correspondences can then be queried directly by nearest-neighbor search. We evaluate VoxCor on intra-subject Abdomen MR--CT and inter-subject HCP T2w--T1w tasks using deformable registration, voxelwise k-nearest-neighbor segmentation, and segmentation-center landmark localization. VoxCor improves the hardest cross-subject, cross-modality transfer settings, reduces encoder sensitivity for dense correspondence transfer, and yields registration performance competitive with handcrafted descriptors and learned 3D features. This positions VoxCor as a reusable feature layer for downstream multimodal analysis beyond pairwise registration. Code, configuration files, and implementation details are publicly available on GitHub at guneytombak/VoxCor.
May 13, 2026cs.CV

MedCore: Boundary-Preserving Medical Core Pruning for MedSAM

Medical segmentation foundation models such as SAM and MedSAM provide strong prompt-driven segmentation, but their image encoders are still too large for many clinical settings. Compression is also risky in medicine because a model can keep high Dice while losing boundary fidelity. We propose MedCore, a structured pruning framework for MedSAM. The main idea is to preserve two kinds of structures: structures that became important during SAM-to-MedSAM adaptation, and structures that have high boundary leverage. We identify the first type by a dual-intervention score that compares zeroing a group with resetting it to its original SAM weight. We identify the second type by boundary-aware Fisher estimation. We also introduce a boundary leverage principle, which shows that compression-induced boundary displacement is controlled by logit perturbation on the boundary divided by the logit spatial gradient. This principle explains why boundary metrics can degrade even when Dice remains high. On polyp segmentation benchmarks, MedCore reduces parameters by 60.0% and FLOPs by 58.4% while achieving Dice 0.9549, Boundary F1 0.6388, and HD95 5.14 after recovery fine-tuning. It also reaches 86.6% parameter reduction and 90.4G FLOPs with strong boundary quality. Our analysis further shows that MedSAM lies in a head-fragile boundary regime: head-pruning steps have 2.887 times larger 95th-percentile boundary leverage than MLP-pruning steps, and this logit-level effect is consistent with BF1 and HD95 degradation. Our code is available at https://github.com/cenweizhang/MedCore.
May 9, 2026cs.CV

MultiMedVision: Multi-Modal Medical Vision Framework

Multi-modal medical imaging enables comprehensive diagnostics, yet current foundation models process 2D (e.g. X-ray) and 3D (e.g. CT) data with separate, dimensionality-specific architectures. We present MultiMedVision, a unified framework for joint 2D/3D representation learning built on a Sparse Vision Transformer. Our model uses 3D Rotary Positional Embeddings and variable-length sequence packing to process mixed-modality batches natively within a shared latent space, without modality-specific adapters or treating 3D volumes as 2D slice sequences. Trained with a self-supervised objective on chest X-rays (MIMIC-CXR) and CT scans (CT-RATE), and using a single shared encoder with 5x less data, MultiMedVision achieves competitive performance on both 2D benchmarks (Macro AUROC 0.82 on MIMIC, 0.84 on CheXpert) and 3D tasks (0.85 on CT-RATE). Analysis of the learned representations reveals coexisting modality-specific and shared feature subspaces, demonstrating that unified cross-dimensional representation learning is feasible without sacrificing modality-specific performance.
May 8, 2026cs.CV

Benchmarking Foundation Models for Renal Lesion Stratification in CT

The rapid proliferation of open-source medical foundation models (FMs) raises a practical question: how well do their pre-trained representations transfer to clinically relevant but data-scarce classification tasks? Particularly in CT-based renal lesion classification, a push toward greater generalizability would be meaningful, as the field is constrained by inherently limited training data. We addressed this through a benchmark of three medical FMs on this specific task. This six-class problem spans common entities like cysts and clear cell renal cell carcinoma, alongside rare subtypes. Using a frozen feature-probing protocol, we compared FM embeddings against a handcrafted radiomics classifier and a 3D ResNet-50 trained from scratch. Models were trained on a composite dataset of 2,854 lesions and evaluated on an external test set of 234 lesions from The Cancer Imaging Archive. Our results reveal two key findings. First, FM performance (AUC 0.70-0.77) matched the from-scratch ResNet (AUC 0.72) while drastically reducing hardware demand, requiring only seconds on a CPU after feature extraction. However, the conventional radiomics baseline significantly outperformed all deep learning approaches, achieving an AUC of 0.88 (all p ≤\leq 0.002). This suggests that current generalist FM embeddings do not yet capture the fine-grained texture and shape heterogeneity driving histological subtype discrimination. Despite their potential in data-scarce settings, medical FMs did not surpass established models for renal lesion stratification, leaving radiomics as the current state-of-the-art.
May 8, 2026cs.CV

DINO-MVR: Multi-View Readout of Frozen DINOv3 for Annotation-Efficient Medical Segmentation

Adapting foundation models to medical segmentation typically requires either backbone fine-tuning or high-capacity task-specific decoders, both of which are difficult to fit reliably when annotations are scarce. We show that frozen DINOv3 features already contain useful structural and boundary cues for medical segmentation, and that the main bottleneck lies in how these features are read out. We propose DINO-MVR, a Multi-View Readout framework for annotation-efficient medical segmentation. DINO-MVR trains only lightweight MLP probes on features from the final three transformer blocks of a frozen DINOv3 backbone, without updating the backbone itself. At inference, each input is interpreted through complementary resolutions and test-time augmentations, whose probability maps are combined by entropy-weighted fusion and refined with simple spatial regularization. For volumetric inputs, Gaussian z-axis smoothing further improves inter-slice consistency. Under fixed evaluation protocols on endoscopy, dermoscopy, and MRI benchmarks, DINO-MVR achieves strong readout-only performance, including 0.895 Dice on Kvasir-SEG, 0.897 Dice on ISIC 2018, and 0.908 Dice on BraTS FLAIR whole-tumor segmentation. With only five annotated BraTS patients, it recovers 98.4% of the performance obtained by the 40-patient BraTS reference run. These results suggest that frozen self-supervised vision backbones can support accurate medical segmentation when paired with an effective multi-view readout.
May 8, 2026cs.CV

Pan-FM: A Pan-Organ Foundation Model with Saliency-Guided Masking for Missing Robustness

Foundation models (FMs) have shown great promise in medical imaging, but most FMs are trained on unimodal data within isolated domains, such as brain MRI alone. Human aging and disease arise through coordinated biological processes across organs, therefore motivating multimodal FMs that learn whole-body representations. A key challenge, however, is that real-world multimodal biomedical data are often missing not at random, which can reduce power, limit generalizability, and introduce bias. We propose Pan-FM, a pan-organ foundation model pre-trained on imaging from seven organs (Brain, Heart, Adipose, Liver, Kidney, Spleen, and Pancreas) under realistic missing-organ scenarios. Pan-FM uses a unified backbone that handles organ missingness during both training and inference, and is pre-trained with masking-based self-distillation. We find that naive multimodal pre-training leads to dominant-organ shortcut learning bias, with the model over-relying on dominant organs such as adipose and heart. To address this, we introduce Saliency-Guided Masking (SGM), which uses the model attention distribution to adaptively mask dominant organs during pre-training, thus encouraging more balanced cross-organ, whole-body learning. Notably, SGM introduces negligible computational overhead and can be seamlessly integrated into existing self-supervised learning frameworks to improve multi-organ representation learning. On the UK Biobank, Pan-FM achieves stronger prediction across 13 disease categories and 14 single disease entities than single-organ and multi-organ baselines, with improved robustness under missing-organ settings. Pan-FM serves as a scalable solution to realistic modality-missingness in multimodal learning in system neuroscience and as a step toward more generalizable whole-body FMs.
May 7, 2026cs.CV

Knowledge Transfer Scaling Laws for 3D Medical Imaging

Vision foundation models are increasingly moving beyond 2D to volumetric domains such as 3D medical imaging, where unified pretraining across different imaging modalities (i.e. CT, MRI, and PET) could provide foundational models for diverse clinical tasks. However, training such models requires mixing heterogeneous imaging domains, and current mixture strategies remain largely heuristic. In this work, we observe that different medical imaging domains scale at variable rates during pretraining, and knowledge transfer between domains is strongly asymmetric: training on one domain can substantially improve another, but the reverse may be much weaker. Interestingly, both MAE reconstruction loss and cross-domain transfer follow predictable power-law trends with domain-specific behaviors. Motivated by these findings, we formulate data allocation as a scaling-law optimization problem. The derived allocations reveal an interpretable hub-and-island structure: highly transferable domains emerge as hubs that benefit many others and deserve strategic allocation, while isolated domains act as islands requiring direct investment. Empirically, transfer-aware allocation outperforms data-proportional sampling by up to 58% and generalizes well to unseen budgets with r=0.989. Downstream validation on disease classification and organ/lesion segmentation further confirms that the derived transfer-aware mixtures provide stronger pretrained representations for clinical 3D medical imaging tasks.
May 6, 2026cs.CV

Deep Reprogramming Distillation for Medical Foundation Models

Medical foundation models pre-trained on large-scale datasets have shown powerful versatile performance. However, when adapting medical foundation models for specific medical scenarios, it remains the inevitable challenge due to the gap induced by the discrepancy between pre-training and downstream tasks, the real-world computation, and speed constraints. Relevant techniques that probably handle this challenge more or less suffer from some intrinsic limitations. For example, knowledge distillation (KD) assumes that teacher and student models share the same task, training strategy, and model structure family, while prevalent parameter-efficient fine-tuning (PEFT) fails to achieve personalized and lightweight deployment. Even the combination of PEFT and KD still struggles to resolve model structures and training strategies inconsistencies between teacher and student models, leading to inefficient knowledge transfer. In this study, we propose a novel framework called Deep Reprogramming Distillation (DRD) to combat the general adaptation challenge. Specifically, DRD introduces the novel reprogramming module that on the one side overcomes the domain and task discrepancy between pretraining and downstream scenarios, and on the other side builds the student-friendly efficient distillation from foundation models to lightweight downstream models. Furthermore, to mitigate variability under different training conditions, we design a centered kernel alignment (CKA) distillation method to promote robust knowledge transfer. Empirical results show that DRD surpasses previous PEFT and KD methods across 18 medical downstream tasks under different foundation models, covering various scenarios including 2D/3D classification and 2D/3D segmentation.