Wearable Health Monitoring

Momentum

9 papers in the last four weeks, up 80% on the four weeks before. 0.1% of all new papers.

Jul 13Week of Sep 28

Latest papers 75

Jun 29, 2026cs.LG

Accelerometry-Derived Digital Biomarkers for Cardiometabolic Risk: A Population-Representative Tabular Benchmark with Uncertainty Quantification

Structured tabular data dominates clinical medicine, yet existing benchmarks fail to reflect real-world properties like complex survey sampling, demographic oversampling, and subgroup fairness. We introduce the NHANES Accelerometry Cardiometabolic Benchmark, derived from NHANES 2003-2006, comprising 1,381 adults with hip-worn accelerometry, fasting laboratory biomarkers, dietary intake, and anthropometrics. We evaluate three tabular learning methods -- ridge regression, XGBoost, and the foundation model TabPFN v2 -- to predict glycated haemoglobin (HbA1c), fasting triglycerides, and C-reactive protein (CRP) from activity phenotypes and lifestyle covariates. TabPFN v2 achieves the best overall performance (HbA1c R^2=0.156, CRP R^2=0.383), while triglycerides remain largely unpredictable (R^2 < 0.05), consistent with known genetic dominance. We apply split conformal prediction to generate distribution-free 90% prediction intervals and evaluate demographic coverage equity across sex and race/ethnicity subgroups. Marginal coverage aligns with the 90% target for CRP and HbA1c but falls below for triglycerides. At the subgroup level, we observe localized undercoverage (e.g., HbA1c for Mexican American participants), illustrating the gap between marginal guarantees and the conditional coverage required for clinical fairness. Code and data are at https://github.com/felizzi/nhanes-accel-cardiometabolic-benchmark.
Jun 29, 2026physics.med-ph

Physically-Constrained Harmonic Separation for Robust Heart and Respiratory Rate Estimation from Wrist Photoplethysmography

Wrist-worn photoplethysmography (PPG) enables continuous monitoring of cardiopulmonary physiology, but reliable heart rate (HR) and respiratory rate (RR) estimation in free-living conditions remains challenging due to non-stationary motion artifacts that spectrally overlap with physiological dynamics. Existing signal-processing methods degrade under strong motion, while unconstrained deep learning approaches often lack physiological interpretability and identifiable structure. We propose a Physically-Constrained Harmonic Separation (PCHS) framework that formulates HR and RR estimation from wrist PPG as an analysis-by-synthesis problem, where accelerometer measurements condition artifact separation rather than directly regressing vital signs. A physics-guided harmonic generator decomposes the observed signal into quasi-periodic physiological components and a motion-related residual, enabling HR recovery from the fundamental frequency and RR prediction from respiratory-driven modulations of the harmonic parameters. Robust reconstruction objectives, separation constraints, and uncertainty-aware weighting stabilize the decomposition under motion. Experiments on the motion-intensive PPG-DaLiA dataset demonstrate that PCHS outperforms state-of-the-art methods while yielding interpretable signal decompositions that effectively disentangle physiological activity from motion artifacts.
Jun 23, 2026cs.LG

Retrieval-Augmented Personalization with Foundation Models for Wearable Stress Detection

Personalization in wearable-based stress detection remains challenging due to substantial inter-individual variability in physiological and behavioral responses. While traditional approaches rely on user-specific fine-tuning or costly self-supervised pre-training on large datasets, we propose a lightweight alternative based on retrieval-augmented personalization. Our method leverages frozen, out-of-domain foundation models to retrieve similar patterns from a target user's history and encode them into a compact personalized embedding that modulates representations extracted by a lightweight transformer network. We evaluate our approach on the WESAD stress detection dataset with N=15 users, comprising wrist-worn physiological (EDA, BVP, temperature) and activity (accelerometer) signals, and report gains of +3.92% in accuracy and +4.76% in macro F1-score over a non-personalized transformer baseline, approaching supervised fine-tuning performance without requiring any labeled user data. We further show that temporal retrieval, where only prior user samples are available, achieves performance close to full intra-user retrieval, demonstrating robustness to limited user history. Finally, we explore personalization in a cross-dataset retrieval setting, leveraging embeddings from the K-Emocon dataset to personalize representations for stress detection on the WESAD dataset.
Jun 16, 2026cs.AI

WEQA: Wearable hEalth Question Answering with Query-Adaptive Agentic Reasoning

Language models are remarkably capable at medical question answering, in some cases surpassing the accuracy of general physicians. However, answering questions about wearable health data remains challenging and understudied, as these ubiquitous sensors produce continuous, high-dimensional, and longitudinal data, which is non-trivial to align with text-centric distributions in LLM pretraining. The diversity of sensor modalities and user intents cannot be effectively handled by a fixed reasoning workflow or a single pretrained foundation model. To address these challenges, we propose WEQA, a query-adaptive agent framework that unifies LLM reasoning with specialized wearable analytical and modeling tools. An LLM controller is employed to synthesize execution plans and dynamically route each query to the appropriate combination of sensor analysis and pretrained models, and perform grounded response auditing with external knowledge. We also curate a benchmark spanning four open wearable datasets comprising analytic and predictive tasks in three different health domains. Experiments show that our framework is 24% more accurate than LLM and agentic baselines, and a blinded study with 12 medical experts and 8 users shows substantial gains in usefulness and clinical soundness.
Jun 16, 2026cs.HC

Talking to Your Data: Exploring Embodied Conversation as an Interface for Personal Health Reflection

Personal health data from wearables are typically presented through dashboards of charts and summary statistics, requiring users to actively interpret patterns and implications. We explore an alternative interaction paradigm: engaging with personal health data through an embodied conversational agent that facilitates objective data reflection in dialogue with the user. We present a system that combines lightweight preprocessing of wearable data with a Unity-based embodied character. Internally, the system follows a dual-agent design in which an Observer agent extracts descriptive statistics and temporal trends, and a Presenter agent communicates these findings through "spoken statistics," intentionally refraining from clinical advice to isolate the impact of the interaction modality. We evaluate this approach through a simulated-self user study (N=5) using a within-subject design. Participants adopted health personas and goals derived from the LifeSnaps dataset to compare traditional dashboard exploration with embodied conversational reflection. Our evaluation focuses on perceived understanding, the specificity of generated actions, and the cognitive shift from passive viewing to active sensemaking. The paper contributes a functional prototype, a design pattern for objective health data narrative generation, and early empirical insights into how embodiment affects the interpretation of personal health metrics.
Jun 14, 2026cs.LG

An Exploratory Study of Blood Glucose Estimation from Photoplethysmography Signals using Machine Learning

Diabetes and extreme blood sugar levels are some of the major health problems faced by humans today across the world. While Continuous Glucose Monitoring (CGM) has emerged as an effective technology for management of diabetes as well as for monitoring blood sugar levels, this technology has traditionally been invasive (that is, requiring the piercing of the skin) and carries the risk of irritation, induration, etc. This highlights the need for accurate and non-invasive CGM methods that can be deployed at scale. With the emergence of various sensing technologies and their integration in wearables like the smart-watch, we now have the capability to continuously monitor body signals like the Photoplethysmogram (PPG) in a non-invasive manner. Having the ability to continuously monitor blood glucose through CGMs and continuously monitor PPG signals through a smart-watch offers an opportunity to get dense data on these two, opening the possibility of building machine learning and deep learning based models to estimate blood glucose level from PPG signals. In this work, we first present a paired dataset comprising continuous PPG signals from a smartwatch along with glucose values recorded using a CGM device. We also present the results of some preliminary experimental explorations performed on our dataset. These preliminary results suggest that some predictive signals may exist, though more exploration is needed with more data from a larger number of individuals. The dataset can be accessed at https://zenodo.org/records/20577959
Jun 13, 2026eess.SP

CAP: Towards PPG Universal Representation Learning with Patient-level Supervision

Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support. Yet existing approaches to universal PPG representation learning largely focus on signal-level objectives and often overlook patient-level health context, which limits generalization to complex clinical tasks and heterogeneous cohorts. To address this gap, we construct a large-scale paired PPG-EHR multimodal dataset by distilling fragmented medical histories and clinical records into cohesive, patient-level electronic health records (EHR). Building on this resource, we propose Clinical Anchored Pretraining for PPG (CAP). During pretraining, CAP performs cross-modal contrastive alignment that anchors PPG representations to patient-level clinical semantics, guiding the encoder beyond waveform fitting toward modeling consistency in a patient's overall physiological state. During downstream adaptation, the pretrained PPG encoder provides clinically grounded representations that strengthen inductive bias and improve robustness and transferability. Experiments demonstrate that CAP consistently outperforms strong baselines on four diverse downstream tasks. CAP achieves a particularly large gain on respiratory rate prediction (up to +87.6% relative improvement over the state-of-the-art baseline) and delivers an average relative +26.7% across all tasks. We further enhance the interpretability of our approach through comprehensive analyses, including ablations and multiple complementary visualizations of the learned representations. The code for our experiments is available at: https://github.com/gody123gody/CAP .
Jun 11, 2026cs.HC

Ride, Track, and Recover: Pilot Randomized Trial of a Wearable Digital Self-Management Intervention During a Veteran Endurance-Cycling Program

Post-traumatic stress disorder (PTSD) in veterans is characterized by persistent hyperarousal and comorbid anxiety and depressive symptoms that are difficult to monitor and manage outside clinical settings. Thirteen veterans participating in a Project Hero cycling event in Texas were randomized by computer-generated sequence in a naturalistic setting to two arms: (1) digital intervention plus physical activity, or (2) physical activity only, plus a third at-home monitoring control cohort consisting of 7 veterans selected from the broader Project Hero veteran community. Continuous smartwatch sensing combined heart rate and accelerometer features to detect hyperarousal events, which were confirmed in real time by participants. Weekly self-report measures of anxiety, depression, and PTSD severity were collected. Generalized additive mixed models characterized nonlinear trajectories over time. Baseline-normalized hyperarousal trajectories differed significantly across conditions, with the digital intervention group (n=7) showing structured stabilization compared to late-study escalation in the physical-only group (n=3). Both cycling groups exhibited acute symptom improvements during the endurance event; however, the digital intervention group demonstrated a higher overall maintenance of gains. The at-home control group (n=4) showed gradual symptom declines. Perceived precision of ML detections varied substantially across individuals and was positively associated with symptom severity, with higher-severity participants confirming a greater proportion of detected events. These results suggest that coupling wearable detection with digital self-management tools may support stabilization of hyperarousal and symptom improvement while emphasizing the importance of personalization and human-centered design in wearable mental health systems.
Jun 11, 2026stat.AP

Event-Aligned Analysis of Multi-Rater Pain Assessments Using Continuous Wearable Physiology

Pain is assessed differently by patients, nurses, and clinicians, yet most computational approaches assume a single ground-truth label - effectively ignoring who is doing the rating. We introduce a rater-aware, event-aligned framework that converts sparse, rater-specific pain ratings into discrete pain-change events and aligns continuous wearable physiological signals to these events, preserving rater identity throughout. Applied to multimodal wearable data collected during spine-related pain procedures, the framework identifies substantial disagreement across rater groups and provides preliminary, exploratory evidence of rater-dependent physiological differences preceding reported pain increases. These findings suggest that pain-physiology relationships may not be rater-invariant, and that aggregating assessments across raters may mask meaningful physiological patterns. A rater-aware, event-aligned perspective is therefore a promising direction for interpreting wearable data in real-world clinical pain assessment.
Jun 10, 2026cs.AI

Reducing the Complexity of Deep Learning Models for EEG Analysis on Wearable Devices

Wearable healthcare devices are the fastest-growing Internet of Things (IoT) sector. Many automated healthcare services rely on two crucial biological signals, namely ECG and EEG, which reflect the activity of the heart and brain, respectively. Although deep neural networks are considered the primary way to process and analyze these signals, the very tight energy and computational power constraints in wearable devices are far below the computational, energy, and memory bandwidth demands of DNN models, thereby impeding the deployment of deep learning in many practical wearable services. This paper investigates the feasibility of deploying state-of-the-art DNN models in resource-constrained wearable devices. Notably, we explore the trade-off between accuracy and computational complexity of DNNs when parameter quantization and electrode reduction methods are used. Our investigation centers on several state-of-the-art DNN models designed for EEG signal analysis, specifically for detecting epileptic seizures. Our findings demonstrate that, when applied judiciously, these techniques can significantly reduce the complexity of the DNNs under consideration with minimal adverse effects on accuracy. These results reveal the explicit trade-offs between accuracy and complexity reduction encountered when adapting DNN-based online EEG analysis for wearable devices.
Jun 10, 2026cs.LG

LLM-Powered Personalized Glycemic Assessment in Type 2 Diabetes with Wearable Sensor Data

Type 2 Diabetes (T2D) poses an increasing global health threat, demanding effective glycemic assessment to support personalized and improved diabetes care. Wearable sensors such as continuous glucose monitors (CGM) and fitness trackers offer many valuable insights for glycemic assessment. However, effectively analyzing these data requires integration with essential individual-level context. Existing methods are often based on traditional machine learning (ML) and rely primarily on historical blood glucose measurements and overlook personalized information, which limits their performance across diverse diabetes populations. Recent advances in large language models (LLMs) have demonstrated their ability to integrate diverse data modalities while modeling sequential dependencies, motivating the exploration of their potential for personalized glycemic assessment. In this paper, we propose GlyLLM, an LLM-powered framework for modeling CGM-based glycemic dynamics through the integration of wearable sensor data and structured metadata. GlyLLM can leverage the extensive prior knowledge of pre-trained LLMs and achieve sensor-text semantic abstraction at decision time. Experiments on two related tasks on the AI-READI dataset demonstrate that our model outperforms traditional ML methods by an average of 13.66% in Root Mean Squared Error (RMSE) for glucose forecasting and 13.08% in Area Under the Receiver Operating Characteristic (AUROC) for diabetes categorization. Additionally, our ablation study shows that diabetes surveys and biometric tests are more critical than other health information for glycemic assessment. Our work presents a promising step toward harnessing the power of LLMs to advance personalized glycemic assessment in T2D care.
Jun 9, 2026eess.SP

DMT: Demographic Conditioning, Morphology-Enhanced Transformer for Cuffless Blood Pressure Estimation from PPG Signals

Blood pressure (BP) is a key marker for cardiovascular risk assessment and therapeutic decision-making, and Photoplethysmography (PPG) enables low-cost, wearable-friendly cuffless BP estimation. However, even with recent progress, many PPG-based models are trained with BP regression alone and may rely on amplitude-dominated shortcuts. In addition, demographic covariates that systematically modulate vascular compliance are often incorporated only via late fusion, limiting subject-specific representation learning. We propose a Transformer-based network for cuffless BP estimation from PPG signal, leveraging self-attention to capture long-range dependencies across multiple cardiac cycles. To account for subject-specific vascular differences, the model is conditioned on demographics via FiLM-style feature modulation applied through the attention and feed-forward sublayers of Transformer blocks. In addition, we add an auxiliary morphology head to guide the model to attend to BP-relevant waveform morphology associated with arterial stiffness and wave reflection. Under calibration-based evaluation protocols on the large-scale PulseDB dataset, the proposed method achieves MAE of 4.56 mmHg for systolic BP and 2.62 mmHg for diastolic BP, reducing errors by 47% and 50% compared with prior demographic-enhanced PPG baselines. The resulting lightweight, single-sensor model supports scalable and clinically grounded cuffless BP estimation in calibration-enabled deployment settings.
May 31, 2026eess.SP

Efficient Temporal Modeling for Mobile Sleep Staging via Lightweight Random Attention

Mobile sleep staging serves as a foundational infrastructure for in-home sleep monitoring and closed-loop modulation. But existing sequential models such as RNNs and Transformers are computationally expensive for mobile deployment. In this paper, we propose Random Attention (RA), a lightweight temporal modeling module based on fixed random projections, which replaces learnable sequence modeling with similarity-based aggregation. RA introduces little additional parameters beyond the epoch encoder while enabling effective temporal smoothing. We further provide a theoretical interpretation via the Random Attention Prior Kernel (RAPK), which decomposes RA into a global smoothing term and a feature similarity term, offering an interpretable view of temporal sleep structure. Experiments on Sleep-EDF-20 and Sleep-EDF-78 show that RA consistently improves epoch-wise baselines by 1-3% in accuracy and F1 score, while achieving competitive performance compared with LSTM, GRU, and Transformer models. RA also demonstrates strong generalization across different backbone encoders and improved robustness over conventional temporal smoothing methods. These results indicate that efficient sleep staging can be achieved through lightweight similarity-based temporal aggregation, making RA suitable for real-time wearable applications.
May 29, 2026cs.LG

Longitudinal Multimodal Sensing of Physical Activity and Well-Being in Older Adults

Wearable and mobile sensing technologies enable continuous monitoring of human behavior and health in real-world settings. However, predictive modeling in longitudinal multimodal data remains challenging, particularly when targeting complex or clinically derived outcomes. In this work, we present a longitudinal multimodal study of 66 older adults conducted in real-world conditions and combining wearable sensing, behavioral monitoring, and clinical assessments. This setting provides a rare opportunity to study an underrepresented population in long-term, into-the-wild conditions. Building on this dataset, we investigate how the alignment between sensed signals and target variables affects predictive performance across health-related tasks. We design a unified evaluation framework spanning tasks with increasing levels of observability, including Activity Levels prediction, Sleep Duration estimation, and Sleep Apnea Severity classification. Our results reveal a clear gradient of predictability: highly observable behavioral targets achieve robust performance (macro-F1 65%), while more abstract outcomes remain challenging despite consistent improvements over baseline models. Moreover, through explainability analysis, we show that historical features consistently emerge as the most informative predictors, highlighting the central role of longitudinal information.
May 29, 2026cs.LG

GlucoFM: A Dual-Stream Foundation Model for Continuous Glucose Monitoring

Continuous glucose monitoring (CGM) provides a dense view of daily metabolic physiology, yet existing generic time-series and CGM-specific foundation models often encode glucose traces as entangled single-stream sequences, leaving the distinct temporal structure of glycemic dynamics only implicitly modeled. We present GlucoFM, a lightweight CGM foundation model that aligns irregular recordings to a 24-hour chronological grid, preserves observation masks, and decomposes glucose dynamics into slow physiological state and transient event streams, capturing low-frequency glycemic baselines and short-term deviations that may reflect acute physiological responses or sensor artifacts. GlucoFM is pretrained on 109,066 hours of unlabeled CGM recordings from 477 subjects with two complementary objectives: masked contextual latent prediction over fused daily representations and temporal dynamics prediction over state and event streams. Across four diverse cohorts and seven clinical prediction tasks, GlucoFM achieves the strongest subject-disjoint linear-probing performance among evaluated baselines, improving average PR-AUC by 4.1 points over the best CGM-specific foundation model. Its gains are most pronounced on core metabolic outcomes, leading PR-AUC on all diabetes-risk and ββ-cell dysfunction tasks and on 3 of 4 insulin-resistance tasks. GlucoFM also achieves the best overall cross-dataset transfer performance and strong few-shot adaptation among evaluated methods, and consistent gains when aggregating multiple days for subject-level prediction, highlighting physiology-aware decomposition as an effective inductive bias for transferable CGM representation learning.
May 29, 2026cs.LG

Adaptive data selection improves wearable prediction under low baseline performance

Adaptive sensing strategies that selectively sample data are increasingly used in wearable health systems to improve prediction performance under limited data budgets, yet their benefits across individuals remain poorly understood. Here, we evaluate adaptive selection of time windows for model training under fixed measurement budgets across multiple sensing modalities, including heart rate, activity, and ecological momentary assessment (EMA), in a longitudinal wearable dataset. We quantify performance gains relative to random sampling using both area under the receiver operating characteristic curve (AUROC) and F1 score. Adaptive strategies yield substantial improvements in AUROC for participants with low baseline performance (with gains up to 0.7), while offering limited or negative gains for participants with strong baselines. Across modalities, adaptive gain is strongly inversely correlated with baseline performance (Pearson r = -0.67; Spearman p = -0.62). At the participant level, most individuals benefit in AUROC (60-80% across modalities), although improvements in F1 are smaller and less consistent. These findings show that adaptive sensing is not uniformly beneficial, but instead provides the greatest value in underperforming settings. Our results support selective deployment strategies that tailor adaptive sensing based on baseline performance to improve efficiency in wearable health monitoring.
May 28, 2026cs.AI

VitalAgent: A Tool-Augmented Agent for Reactive and Proactive Physiological Monitoring over Wearable Health Data

Wearable devices enable continuous monitoring of physiological signals such as ECG and PPG, but existing mHealth systems are largely limited to task-specific prediction pipelines or reactive question answering over static summaries. They lack the ability to support temporal reasoning, persistent physiological context, and proactive monitoring over long-term signal streams. We propose VitalAgent, a tool-augmented agentic framework for ECG/PPG-based mHealth that supports both reactive question answering and proactive monitoring. VitalAgent is built on a longitudinal physiological memory and a tool-augmented reasoning interface that enables dynamic computation over raw signals. We further introduce VitalBench, a longitudinal physiological monitoring benchmark dataset comprising 1,862 QA pairs for reactive question answering and 90.2 hours of continuous ECG/PPG recordings for proactive monitoring, covering cardiac, physical activity, and stress-related tasks. Experiments demonstrate that VitalAgent achieves over 25% improvement over prompt-based and ReAct baselines in reactive evaluation and supports proactive alert monitoring over long-term physiological signals, highlighting the importance of dynamic tool use and long-term physiological monitoring.
May 21, 2026cs.LG

CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment

Assessing cognitive load continuously and at low latency would help adaptive human-computer interaction, but it remains hard because labeled data are scarce and models generalize poorly across subjects. Recent ECG foundation models, pre-trained on millions of clinical diagnostic ECG recordings, yet they do not apply directly to wearable devices when the sensor configuration and the task both differ. We present CogAdapt, a framework that adapts a clinical ECG foundation model to wearable cognitive load assessment. CogAdapt has two parts. LeadBridge is a learnable adapter that maps 3-lead wearable signals to a 12-lead-compatible representation. ProFine is a progressive fine-tuning strategy that unfreezes encoder layers in stages while limiting representational drift in the pre-trained model. On two public datasets (CLARE and CL-Drive) under leave-one-subject-out cross-validation, CogAdapt reaches macro-F1 of 0.626 and 0.768, improving over from-scratch baselines by 11.2 and 16.1 percentage points. The results show that a clinical ECG pretraining can support subject-independent cognitive load assessment from wearable sensors.
May 21, 2026cs.AI

Towards a General Intelligence and Interface for Wearable Health Data

While ubiquitous wearable sensors capture a wealth of behavioral and physiological information, effectively transforming these signals into personalized health insights is challenging. Specifically, converting low-level sensor data into representations capable of characterizing higher-level states is difficult due to high phenotypic diversity and variation in individual baseline health, physiology, and lifestyle factors. Moreover, collecting wearable data paired with health outcome annotations is laborious and expensive, and retrospective annotation remains practically unfeasible, contributing to a scarcity of data with high-quality labels. To overcome these limitations, we propose a foundation model for wearable health that is pretrained on more than one trillion minutes of unlabeled sensor signals drawn from a large cohort of five million participants. We demonstrate that the joint scaling of model capacity and pretraining data volume leads to systematic improvements in performance, as evaluated on a diverse set of 35 health prediction tasks, spanning cardiovascular, metabolic, sleep, and mental health, as well as lifestyle choices and demographic factors. We find that this population scale representation unlocks label-efficient few-shot learning and generative capabilities for robust daily metric estimation. To further leverage this learned representation, we deploy a classroom of LLM agents to autonomously search the space of downstream predictive heads built on the model embeddings, showing broad performance improvements that increase with LLM model capacity. Finally, we show how integrating these downstream predictors into a Personal Health Agent can support model responses that are more relevant, contextually aware, and safe, and we validate this via 1,860 ratings from a cohort of clinicians.
May 18, 2026cs.LG

Uncertainty Reliability Under Domain Shift: An Investigation for Data-Driven Blood Pressure Estimation in Photoplethysmography

Uncertainty quantification (UQ) is critical for safety-critical domains like healthcare, yet it is rarely evaluated under realistic out-of-distribution (OOD) conditions. Here, we assessed predictive performance and uncertainty reliability for deep learning-based blood pressure (BP) estimation from photoplethysmography (PPG) signals under both in-distribution (ID) and OOD settings. Using an XResNet1D-50 trained on PulseDB and tested on four external datasets, we compared deep ensembles (DE) and Monte Carlo dropout (MCD) with Gaussian negative log-likelihood (GNLL) and mean squared error (MSE) losses, optionally followed by post-hoc recalibration via conformal prediction (CP), temperature scaling (TS), and isotonic regression (IR). The key findings of our study are as follows: (1) DE provides stronger predictive robustness under domain shift than MCD, an advantage that becomes clear primarily under external shift. (2) Recalibrated GNLL-based methods yield the best uncertainty calibration (e.g., GNLL+DE+CP for systolic blood pressure (SBP), GNLL+DE+TS for diastolic blood pressure (DBP)), while MSE-based uncertainty requires recalibration to become practically useful. (3) Across settings, CP and TS offer the most consistent gains, with IR remaining competitive in several cases. Overall, our results identify DE-based methods as most robust for predictive performance under domain shift, GNLL as strongest for native UQ, and recalibration as essential for making MSE-based uncertainty practical. These findings highlight the need to jointly assess predictive accuracy and calibration on external data for trustworthy cuffless BP estimation
May 18, 2026cs.HC

Multi-site PPG: An In-the-Wild Physiological Dataset from Emerging Multi-site Wearables

Wearables are widely used for mobile health monitoring, and photoplethysmography (PPG) is a key sensing modality for heart rate and related physiological measurements. However, public in-the-wild PPG datasets remain largely wrist-centric or limited to short, controlled studies, constraining research on emerging wearable form factors. We present Multi-site PPG, an in-the-wild physiological dataset collected from four custom-developed unobtrusive wearables: a smart earring, ring, watch, and necklace. Each device records green and infrared reflective PPG, 3-axis acceleration, and temperature with timestamps for cross-device alignment, while a Polar H10 chest strap provides reference electrocardiogram (ECG). Participants wore the devices for multiple days during daytime activities while continuing their normal routines. The dataset contains over 350 hours of raw data and 230-290 hours of modeling-ready 8-second windows per wearable. We benchmark heuristic, supervised, and self-supervised heart-rate estimation methods, showing substantial body-site differences: the best methods achieve mean absolute errors (MAEs) of 2.30 bpm on the earring, 5.13 bpm on the ring, 8.37 bpm on the watch, and 8.68 bpm on the necklace. We further analyze motion effects and evaluate multi-site and PPG-accelerometer fusion, demonstrating the dataset's value for robust physiological sensing across emerging wearable form factors.
May 15, 2026cs.LG

Towards Family-Grouped Hierarchical Federated Learning on Sub-5KB Models: A Feasibility Study of Privacy-Preserving ECG Monitoring for Ultra-Resource-Constrained Wearables

Cardiovascular disease remains the leading cause of death worldwide, and early detection of arrhythmias through continuous ECG monitoring on wearable devices can prevent life-threatening events. Federated Learning (FL) enables privacy-preserving collaborative training by keeping raw ECG data on device, yet standard FL incurs prohibitive communication overhead and standard deep learning models cannot fit on ultra-low-power microcontrollers. We propose Family-Grouped Hierarchical Federated Learning (Family-FL), a three-tier architecture that uses the family as a natural privacy boundary for intra-family aggregation before global synchronization. We further design a hardware-constrained Tiny CNN-LSTM architecture with only 669 parameters, INT8-quantized to occupy merely 4.65KB Flash and 2.95KB RAM, meeting the constraints of STC32G12K128-class microcontrollers. Experiments on the MIT-BIH Arrhythmia Database (mean of 5 independent runs with different seeds) demonstrate that Family-FL reduces communication volume by 76.7% compared to FedAvg while maintaining comparable accuracy. Family-FL-Tiny achieves 91.9 +/- 1.2% accuracy with macro-F1 of 0.483 +/- 0.031, reducing total communication to 0.31% of FedAvg. The model achieves reliable ventricular arrhythmia detection (per-class F1 = 0.80), the most clinically critical abnormality for home-based preliminary screening. These results demonstrate the technical feasibility of privacy-preserving federated learning on ultra-resource-constrained microcontrollers through simulation-based evaluation. We honestly discuss limitations: no hardware deployment, single-dataset validation (MIT-BIH, 47 subjects), reduced rare-class sensitivity, and absence of formal differential privacy guarantees.
May 14, 2026cs.HC

A Formative Study of Brief Affective Text as a Complement to Wearable Sensing for Longitudinal Student Health Monitoring

Wearable devices capture physiological and behavioral data with increasing fidelity, but the psychological context shaping these outcomes is difficult to recover from sensor data alone, limiting the utility of passive sensing for digital health goals such as early detection of distress, personalized intervention, and timely clinical outreach. We examined whether ultra-brief naturalistic concern text could serve as a scalable complement to passive sensing. In a year-long study of 458 university students (3,610 person-waves) tracked with Oura rings, participants responded bimonthly to an open-ended prompt about what concerned them most; responses had a median length of three words. We compared dictionary-based, general pretrained, and domain-adapted NLP approaches using within-person mixed-effects models across nine sleep and physical activity outcomes to determine which method best recovers physiologically relevant signal from brief naturalistic text. Weeks dominated by academic concern framing were associated with lower physical activity; weeks characterized by emotional exhaustion language were associated with poorer sleep quality and lower heart rate variability. General pretrained embeddings performed as well as or better than domain-adapted models across most outcomes, with differences between the two generally small and within the range of estimation noise. Zero-shot classification of concern topics showed no consistent evidence of association with outcomes; affective dimensions across all three methods showed more associations, though these did not survive correction for multiple comparisons, offering preliminary evidence that emotional register may carry more signal than topical content. These findings offer design guidance: ultra-brief affective prompts enrich the psychological interpretability of passive physiological data at minimal burden.
May 13, 2026cs.LG

Uncertainty-Driven Anomaly Detection for Psychotic Relapse Using Smartwatches: Forecasting and Multi-Task Learning Fusion

Digital phenotyping enables continuous passive monitoring of behavior and physiology, offering a promising paradigm for early detection of psychotic relapse. In this work, we develop and systematically study two smartwatch-based frameworks for daily relapse detection. The first forecasts cardiac dynamics and flags deviations between predicted and observed features as indicators of abnormality. The second adopts a multi-task formulation that fuses sleep with motion and cardiac-derived signals, learning time-aware embeddings and predicting measurement timing. Both pipelines use Transformer encoders and output a daily anomaly score, derived from predictive uncertainty estimated via an ensemble of multilayer perceptrons to improve robustness to real-world wearable variability. While each framework independently demonstrates strong predictive power, we show that they capture complementary physiological signatures. Consequently, we propose a late-fusion strategy that synergistically combines the anomaly signals from both architectures into a unified decision score. We benchmark our methodology on the 2nd e-Prevention Grand Challenge dataset, where our fused model achieves a 8% relative improvement over the competition-winning baseline. Our results, supported by extensive ablation studies, suggest that the integration of diverse digital phenotypes, cardiac, motion, and sleep, is essential for the high-fidelity detection of psychotic relapse in real-world settings.
May 11, 2026physics.med-ph

Attractor-Vascular Coupling Theory: Formal Grounding and Empirical Validation for AAMI-Standard Cuffless Blood Pressure Estimation from Smartphone Photoplethysmography

This work proposes Attractor-Vascular Coupling Theory (AVCT), a mathematical framework showing that cardiac attractor geometry encodes blood pressure (BP) information sufficient for AAMI-standard estimation, and validates the theory through a calibrated cuffless BP model using photoplethysmography (PPG). AVCT is grounded in Cardiac Stability Theory and operationalized using Takens delay embedding and attractor morphology extraction. Two theorems, one proposition, and one corollary formally justify the use of PPG attractor features for BP estimation and predict the feature-importance hierarchy. A LightGBM model trained on pulse transit time (PTT) and Cardiac Stability Index (CSI) attractor features under single-point calibration was evaluated using strict leave-one-subject-out cross-validation (LOSO-CV) on 46 subjects from BIDMC ICU (n = 9) and VitalDB surgical data (n = 37), comprising 29,684 windows. The model achieved systolic BP (SBP) mean absolute error (MAE) of 2.05 mmHg and diastolic BP (DBP) MAE of 1.67 mmHg, with correlations r = 0.990 and r = 0.991, satisfying the AAMI/IEEE SP10 requirement of MAE below 5 mmHg. Median per-subject MAE was 1.87/1.54 mmHg, and 70%/76% of subjects individually satisfied AAMI criteria. A PPG-only ablation using nine smartphone attractor features matched the ECG+PPG model within 0.05 mmHg, demonstrating that clinical-grade BP tracking is achievable using only a smartphone camera while surpassing prior generalized LOSO-CV results using fewer sensors. All four AVCT predictions were quantitatively confirmed, with 91.5% error reduction from uncalibrated to calibrated estimation (epsilon_cal = 0.915). Unlike post-hoc explainable AI methods, AVCT predicts features satisfying the architectural faithfulness criterion of the Explainable-AI Trustworthiness (EAT) framework and grounding BP estimation in nonlinear dynamical systems theory.
May 11, 2026eess.SP

A Nonlinear Complexity Index for Wearable PPG Cardiovascular Stability: Multiscale Validation, Systematic Evaluation Correction, and Bayesian Parameter Optimization

Cardiovascular stability estimation from wearable photoplethysmography (PPG) requires a principled nonlinear framework, yet major gaps persist in heuristic parameter selection and evaluation protocols that inflate reported performance. We introduce a Stability-Constrained Cardiovascular Stability Index (SCSI) grounded in Cardiac Stability Theory and validate it across 176,742 segments from four heterogeneous PPG datasets at three temporal scales. Cross-dataset analysis demonstrates a large Kruskal-Wallis effect size (eta2 = 0.351, p < 0.001), strong cross-scale consistency (kappa > 0.97), and significant correlation with respiratory rate across 53 ICU records (Spearman r = 0.346, p = 0.011). We identify three evaluation artifacts that inflate heuristic AUC from a true baseline of 0.573 to 0.752: segment-level cross-validation leakage, test-set normalization leakage, and pooled-AUC overweighting that conceals per-patient failure. Correcting these artifacts and applying Bayesian optimization over 15 joint parameters yields SCSI with cross-validation AUC of 0.720. On 18 held-out records, SCSI achieves pooled AUC of 0.757 (95% CI: 0.686-0.828) and negative predictive value of 0.966 for tachypnea screening, while per-record AUC of 0.497 +/- 0.207 is disclosed for transparency. External validation on 42 elective-surgery records yields AUC of 0.621, confirming cross-population generalization. Ablation analysis identifies the nonlinear complexity module as the dominant component. A sparse three-component architecture is proposed as the minimal deployable configuration. The corrected protocol provides a reproducible benchmark for future wearable cardiovascular stability indices.
May 10, 2026cs.LG

Biosignal Fingerprinting: A Cross-Modal PPG-ECG Foundation Model

Cardiovascular disease remains the leading cause of global mortality, yet scalable cardiac monitoring is hindered by the gap between diagnostic-rich ECG and ubiquitous wearable PPG. Bridging this gap requires representations that are compact, transferable across modalities and devices, and deployable without task-specific retraining. Here we introduce biosignal fingerprints: compact latent representations of cardiovascular state derived from a cross-modal foundation model, the Multi-modal Masked Autoencoder (M2AE), trained on over 3.4 million paired ECG and PPG signals. M2AE integrates modality-specific encoders with a shared bottleneck and dual decoders, jointly optimized using reconstruction and cross-modal contrastive objectives, yielding generalizable fingerprints that retain intra- and inter-modality features. Like a biometric fingerprint, these representations uniquely encode an individual's cardiovascular state in a modality-agnostic, privacy-preserving form reusable across clinical tasks without exposing raw waveform data or requiring model retraining. Across 7 downstream tasks, spanning cross-modal reconstruction, cardiovascular disease classification, hypertension detection, mortality prediction, and demographic inference, biosignal fingerprints achieve competitive or superior performance compared to leading domain-specialist foundation models in frozen settings, including an AUROC of 0.974 for five-class CVD classification and 0.877 for hypertension detection, with a maximum improvement of 27.7% in AUROC across 5 classification tasks. Critically, strong performance is maintained with only a single modality, enabling deployment in resource-constrained, single-sensor environments typical of real-world wearable monitoring, with direct implications for continuous cardiovascular monitoring across clinical and consumer health settings.
May 9, 2026cs.LG

WavesFM: Hierarchical Representation Learning for Longitudinal Wearable Sensor Waveforms

Wearable sensors enable the continuous acquisition of high-resolution physiological waveforms, such as photoplethysmography and accelerometry, under free-living conditions. However, inferring health-related phenotypes from these signals presents significant challenges due to high sampling frequencies, multimodal dependencies, and extreme sequence lengths (e.g., weeks of recordings), compounded by a scarcity of ground-truth labels. To address these challenges, existing self-supervised learning (SSL) methodologies typically follow two paradigms: (1) learning rich morphological representations from short waveform segments while collapsing longitudinal dynamics through simple aggregation, or (2) modeling behavioral patterns from coarse, hand-crafted features (e.g. heart rate, step counts) spanning longer horizons but foregoing subtle, predictive signatures in raw waveforms. To bridge this gap, we propose WavesFM, a foundation model utilizing a two-stage SSL framework for longitudinal physiological data. Specifically, we decompose the learning problem into two stages: first, a segment-level encoder is pretrained to extract local embeddings from short waveforms; subsequently, a temporal encoder is trained to model the sequence of these embeddings across a multi-day horizon. This hierarchical approach overcomes the computational complexity of high-resolution, long-sequence data, allowing the overall model to capture both local signal semantics and the complex circadian and inter-day variations governing physiological dynamics. Pretrained on over 6.8M hours (N=324k individuals) of recordings for the first stage and 5.3M hours (N=10k) for the second stage, WavesFM demonstrates superior performance across 58 diverse tasks spanning demographics, lifestyle, health conditions, and medications.
May 8, 2026cs.LG

Emergent Symbolic Structure in Health Foundation Models: Extraction, Alignment, and Cross-Modal Transfer

Health foundation models (FMs) learn useful representations from wearable sensors, but interpreting what they encode and transferring that knowledge across modalities after training remains difficult. We present a post-training framework that decomposes frozen embeddings into interpretable directions, referred to as symbols, and use these symbols to align the embedding spaces without retraining. We evaluate the framework on three FMs for photoplethysmography (PPG) and accelerometer data, independently pretrained on ~20M minutes of unlabeled data from ~172K participants, and analyzed on a held-out cohort of 30K subjects. We find that extracted symbols associate selectively with health conditions and physiological attributes, and these associations are partially shared across modalities and architectures. Cross-modal transfer via symbols retains more than 95% of in-domain performance, is nearly symmetric across domain directions, and saturates with limited paired data, together indicating that alignment recovers a shared low-dimensional subspace rich in physiological information. Overall, these results suggest that health FM embeddings contain an interpretable symbolic organization that is shared across modalities and supports cross-domain transfer without joint training.
May 5, 2026eess.SP

Domain-Adaptive Arrhythmia Classification Using a Hybrid Transformer on Wearable Heart Signals

Cardiovascular disease remains the leading cause of death globally, underscoring the need for effective, accessible monitoring solutions, particularly through wearable devices that enable continuous, real-time tracking of heart rhythms in home settings. However, deploying deep learning models trained on clinical electrocardiogram (ECG) datasets to wearable devices remains challenging, as differences in recording equipment, signal quality, and patient populations introduce domain shifts that degrade model performance. We propose a hybrid transformer model that processes continuous ECG signals alongside seven heart rate variability (HRV) features, where the raw signal path captures beat-level morphological patterns and the HRV path encodes rhythm regularity statistics, allowing the model to jointly leverage complementary information from both representations. To enhance the model's ability to generalize across domains, we employ representation learning techniques, including Maximum Mean Discrepancy (MMD), a non-parametric kernel-based metric that quantifies the distance between feature distributions of different domains, to align feature distributions between source and target domains, addressing the challenge of domain shifts between public datasets and wearable device data. By leveraging five public ECG datasets for training, the model learns robust, generalized representations that mitigate domain-specific biases. When tested on wearable device data with an unseen domain, the model achieved an F1-macro 95% and balanced accuracy of 96.15%. These results demonstrate minimal performance degradation, with only a 2% drop in F1-macro compared to seen-domain evaluation, highlighting the model's generalization capabilities and its potential for reliable, real-time heart monitoring applications in home and ambulatory settings.