Medical Image Localization
Momentum
8 papers in the last four weeks, up 60% on the four weeks before. 0.1% of all new papers.
Latest papers 66
Prototype-based medical image classifiers present three clinical limitations: they treat findings as independent, silently amplify unsafe physician feedback, and require full retraining whenever a new finding is needed. We present GRAPE (Graph-Augmented Prototype Explanations), a unified architecture that addresses all three challenges. First, a Graph Attention Task Head models anatomical concept co-occurrence, boosting macro-F1 by +13.8,pp over the prototype baseline on TBX11K. Second, a Concept-Mismatch Safety Check - the first such mechanism in prototype-based medical classifiers - warns when the model's dominant finding inside a doctor-drawn region conflicts with the claimed label, catching 85% of erroneous annotations versus 51% for MC-Dropout with no extra inference cost. Third, Open-Vocabulary Prototype Anchoring aligns visual prototypes to clinical text, allowing a new finding to be added from a single labeled image without modifying any other component. On NIH ChestX-ray14, one Effusion example recovers full-supervision localization accuracy; on TBX11K, prototype maps achieve 2.6x better lesion localization than end-to-end baselines. All three capabilities add only +1~ms latency at interactive batch size. The project page is https://github.com/KurbanIntelligenceLab/GRAPE.
Pseudo-Text-Conditioned 3D Grounding DINO for Organ Localization in Abdominal CT
Reliable organ localization in abdominal CT can provide spatial priors for downstream trauma analysis. We propose CT-3GDINO, a lightweight 3D detector that adapts a Grounding-DINO-style query-based architecture to fixed organ localization using frozen pseudo-text class tokens instead of a real text encoder. The model combines a Swin3D visual backbone, bidirectional feature enhancement, pseudo-text-guided query selection, and a cross-modality decoder to predict normalized 3D boxes for liver, spleen, left kidney, right kidney, and bowel. We train and evaluate on 193 matched RSNA/RATIC CT volumes with segmentation-derived boxes. The best multi-scale model, trained from scratch, achieves 0.5830 overall top-1 class-wise mAP over 3D IoU thresholds from 0.1 to 0.7, outperforming fixed- and trainable-backbone classification-pretrained variants with 0.5570 and 0.4657 mAP. Performance is strong for coarse localization, with 0.9649 AP at IoU 0.1, but remains limited for strict box alignment, with 0.1552 AP at IoU 0.7. These results establish CT-3GDINO as an open-source baseline for pseudo-text-conditioned 3D organ localization and motivate future work on localization-aware pretraining, richer multimodal conditioning, and injury-focused detection.
LayersReg: A Layer-by-Layer Progressive Regressor for Reliable Intraoperative 3D/2D Registration
3D/2D registration serves as a cornerstone technique in surgical navigation. Traditional iterative optimization algorithms suffer from low efficiency and high failure rates in intraoperative settings. Deep learning-based methods reformulate registration from iterative optimization to a regression problem that maps image appearance features to spatial pose, typically achieving improved real-time performance and accuracy. However, such learnable methods are confined to memory-driven retrieval of specific pose features rather than understanding the task of image alignment itself, which limits their generalization in complex scenarios. We propose LayersReg, a pioneering regression paradigm that endows the model with 3D anatomical awareness and searches for the correct pose in a progressive, layer-by-layer manner. Inspired by the iterative pose-searching optimization criterion of classical registration, LayersReg searches for correlations between the moving and fixed images in feature space, capturing the trend of pixel flow and thereby converging iteratively toward the correct spatial pose transformation. We further design a coupling of node-wise regression with the progressive registration framework to enhance the model's perception of spatial pose changes. Experimental results demonstrate that under large offsets and multimodality conditions, LayersReg achieves high accuracy on both X-ray/CT registration (0.68°, 1.41 mm) and slice localization (0.73°, 1.55 mm) tasks, outperforming existing state-of-the-art methods while meeting the intraoperative demands for precision and real-time capability.
BenchX: Benchmarking AI Models for Cancer Detection and Localization with Demographic and Protocol Biases
Artificial intelligence (AI) has achieved remarkable success in medical imaging, but it is widely recognized that these models often perform inconsistently across real-world clinical settings. Such inconsistencies occur when patient demographics and imaging protocols vary, for example, in detecting small tumors, analyzing scans from different contrast phases, or evaluating patients of different ages or sexes. To quantify these inconsistencies, we develop a large-scale, open benchmark of 85,355 CT scans that systematically evaluates 12 tumor-detection AI models across tumor size, location, patient subgroup, and imaging protocol. We leverage large language models (LLMs) to extract and organize subgroup information from clinical data, which makes the analysis both scalable and reproducible. Our benchmark reveals that current state-of-the-art AI models, optimized for average accuracy, perform poorly in rare or underrepresented subgroups, such as young, female African Americans. However, collecting sufficient annotated data for these rare cases is often impractical. The benchmark provides a foundation for building more reliable and robust AI models for tumor detection and highlighting the need for rigorous, subgroup-level evaluation in medical imaging and computer vision. Datasets, code
Female-RHINO: A Real-Time Scanner-Integrated Framework for Automated Quantitative Uterine MRI Analysis and Structured Reporting
Standardized assessment of uterine MRI remains challenging due to anatomical variability, observer dependence, and the lack of workflow-integrated automated analysis tools. This work presents Female-RHINO: (R)eproductive (H)ealth (I)maging A(N)alysis T(O)ol, a real-time AI-assisted framework for automated quantitative uterine MRI analysis and structured reporting during image acquisition. We present an end-to-end system that integrates inline communication with the MRI scanner and deep learning-based analysis to derive quantitative uterine biomarkers from sagittal T2-weighted pelvic MRI. The framework combines segmentation and anatomical landmark detection models trained and evaluated on more than 500 multi-center datasets spanning diverse protocols, vendors, and patient populations. It performs volumetry, detects and quantifies common incidental findings such as fibroids and Nabothian cysts, and extracts six anatomical landmarks for biometric assessment. Results are compiled into a structured clinician-oriented report with integrated visualizations, without manual interaction. Evaluation on independent retrospective and prospective cohorts demonstrated robust performance across varying acquisition settings. Mean Dice similarity coefficients were 0.82 for the uterus and 0.80 for fibroids, with lower but consistent agreement for Nabothian cysts. Landmark detection achieved a mean radial error of 3.7 mm. End-to-end processing was completed in under 70 seconds, enabling availability of results during the ongoing scan. Prospective deployment yielded immediate, standardized, and reproducible analyses supported by inter-observer agreement. The proposed system enables real-time scanner-integrated AI for automated uterine MRI analysis and reporting, with potential to improve standardization, efficiency, and clinical workflow in pelvic imaging.
NoduLoCC2026: Lung Nodule Localization and Classification Contest from Chest X-Ray Images
We propose NoduLoCC2026, a challenge on lung nodule detection and localization in chest X-ray images. We have provided a dataset for both tasks and received submissions from 5 international teams. The participating teams' solutions are presented in this work along with results on an external dataset used for testing. Proposed methods show good performance on the classification task. The best method shows a balanced accuracy score of 0.72 and AUC-ROC of 0.79. We highlight the limitations of current approaches for the localization task, with the best approach having predicted the correct number of nodules on 53% of the test images with a median distance of 12.83mm, showing that it is a more challenging task than the first one. The challenge website is available via https://gt-i2mdp.github.io/website/nodule_challenge.html.
Contour-Constrained Deformable Registration with Parameter Characterization for Head and Neck Surgical Guidance
With 890,000 annual new cases globally, head and neck squamous cell carcinoma has one of the highest recurrence rates among solid malignancies. Although frozen section analysis is the standard of care for intraoperative margin assessment, accurately relocating detected positive margins on the resection bed remains challenging due to imprecise alignment between resected specimens and their resection bed, compounded by post-resection mucosal tissue shrinkage. We present a biomechanics-driven deformable registration framework that corrects post-resection tissue deformation to provide intraoperative guidance. Our approach registers 3D specimen meshes to intraoperative resection bed point clouds using a deformable registration approach based on regularized Kelvinlet basis functions. The registration matches surface point clouds, fiducial landmarks, and boundary contour constraints that directly penalize perpendicular distance-to-agreement between specimen and resection bed boundaries. Across nine specimens from skin, buccal mucosa, and tongue sites, the overall mean target registration error was mm using rigid registration, which decreased to mm (26.19% reduction) using deformable registration without contour constraint. The proposed contour-constrained deformable registration further reduced the error to mm, a 49.41% reduction relative to rigid registration. We observed the largest reduction in the most clinically challenging tongue specimens. We also performed a systematic two-stage parameter search to characterize the relative importance of surface alignment, fiducial correspondences, contour constraint, and strain energy regularization. This search revealed that contour weighting dominates registration accuracy for tissue types with large lateral deformation, while the algorithm operates over a broad range of parameter combinations.
Toward Training-Free Zero-Shot Anomaly Detection in 3D Medical Images: A Batch-Based Approach Using 2D Foundation Models
Zero-shot anomaly detection (ZSAD) is attractive for medical imaging because clinical systems must handle heterogeneous acquisition protocols, changing patient populations, and pathologies for which annotated training data may be unavailable. Most existing zero-shot anomaly detection methods are designed for 2D images, and their direct extension to 3D medical volumes is limited by the scarcity of large-scale volumetric foundation models or by the difficulty of utilizing volumetric context. We propose CS3F, a training-free batch-based framework for ZSAD in 3D medical images using 2D foundation models. Each volume is decomposed along multiple anatomical axes and encoded slice-wise by a 2D vision transformer. These are then converted into localized volumetric tokens by pooling neighboring slice features. Anomaly scores are obtained from cross-subject mutual similarity: tokens that lack close analogues in other subjects are assigned higher anomaly scores. To reduce the attenuation of focal lesion signals caused by depth pooling, we introduce a coarse-to-fine tokenization strategy that enables fine-resolution volumetric scoring without exhaustive matching. CS3F is evaluated on brain MRI across metastases, glioma, and stroke, as well as validated on lung CT to test generalizability beyond atlas-aligned brain MRI. The results show that frozen 2D foundation models can support anomaly localization in 3D medical images, and that the benefit of fine tokenization depends strongly on lesion contrast and imaging modality.
CEVAR: Centerline Embedding Extraction for Endovascular Aneurysm Repair
Long-term mortality rates after endovascular aneurysm repair (EVAR) remain elevated due to post-EVAR rupture caused by loss of seal in stent graft sealing zones. Structured CT review using centerline measurements improves detection, but current workflows require manual centerline editing and expert operators. We propose a transformer framework for automated, protocol-driven sealing zone assessment that combines 3D centerline tracking with embedding-based geometric prediction. Two state-of-the-art image-to-graph models are evaluated for aorto-iliac centerline extraction from follow-up CT and for measurement of stent position, vessel diameters, and seal lengths according to EVAR4C protocol. Across the full test set and a challenging no-contrast subset, the proposed fully automatic method outperforms the commercial semi-automatic workflow.
HSQ-VLM: A Novel Spatially-Constrained Quadrant Segmentation VLM Model for Explainability in Diabetic Retinopathy
Diabetic Retinopathy (DR) is an aggressive retinal disease and a leading cause of global blindness, yet its clinical management is currently hindered by the black-box nature of diagnostic AI. While deep learning models achieve high classification accuracy, there is a critical lack of explainability methods capable of detailing the exact anatomical landmarks and lesion distributions that lead to a clinical decision for DR. Therefore, we propose HSQ-VLM, a novel quadrant segmentation pipeline on fundus images that utilizes a Landmark-Anchored Cartesian Cross-Attention mechanism to unify visual feature extraction with structured clinical reasoning. Unlike traditional methods that rely on arbitrary image partitioning, our pipeline implements 4-quadrant Topological Latent Partitioning (TLP) to dynamically align retinal features with a fovea-centered coordinate system. This allows the Vision-Language Model to generate natural language reports that quantify pathology with anatomical precision. On a dataset of 3,500 high-resolution fundus images, this innovative methodology achieved a lesion detection sensitivity of 99.6% for hemorrhages and 96.4% for microaneurysms, while demonstrating a significant reduction in boundary-ambiguity errors compared to standard segmentation baselines.
Frozen Foundation-Model Embeddings Discard Small-Lesion Signal in Chest Radiography: Implications for Pre-Deployment Evaluation
Frozen vision-transformer (ViT) foundation-model embeddings increasingly serve as the substrate for downstream chest-radiography (CXR) pipelines, yet where small-scale, low-contrast signal is retained or lost in the frozen forward pass has not been systematically quantified across architectures, pretraining domains, and objectives. We probed five frozen ViTs (RAD-DINO, DINOv2-B/14, DINOv3 ViT-7B, BiomedCLIP, MedSigLIP) and a frozen DINO-pretrained ResNet-50 architectural control across three large CXR cohorts (NIH-CXR14, MIMIC-CXR, Emory-CXR; aggregate pool n=492,724) and ChestX-Det10 (n=3,543; 1,462 small-lesion bounding boxes across Calcification, Nodule, Mass). Each model was evaluated with a small-scale-perturbation panel and a region-aware bounding-box-stratified probe on real lesions, comparing three pooling modes from the same forward pass: classification token (CLS), patch-mean (mean over all final-layer patch tokens), and bounding-box-restricted patch-local. On the perturbation panel, CLS embeddings sat at the chance floor (area under the ROC curve [AUC] 0.500-0.524); patch-mean was indistinguishable from CLS on iso-blur and reticular-fine cells but rose with CLS on larger directional-blur footprints, while disease AUC on globally decided tasks ranged 0.642-0.913. Patch-local probes recovered AUC ~1.0 from the same forward pass (per-model mean improvement +0.412 to +0.488); the ResNet-50 control reproduced the chance floor. On ChestX-Det10, image-level CLS classification showed within-class small-versus-large stratum gaps up to +0.243 AUC; bounding-box-level patch-local pooling on the same forward pass recovered AUC >= 0.899 on every (model x class) cell. Frozen ViT embeddings silently suppress small-scale signal at the global-aggregation step; the signal is recoverable from patch tokens conditional on a region of interest.
DualGate-Net: A Prior-Gated Dual-Encoder Framework for Histopathology Cell Detection
Cell detection in histopathology images strongly depends on surrounding tissue context, where visually similar cells may belong to different classes under different microenvironments. Recent tissue-aware methods incorporate contextual priors, but often rely on static fusion strategies that may propagate noisy information. In this work, we propose DualGate-Net, a prior-aware dual-encoder framework that combines a ConvNeXtV2-based local encoder and a SegFormer-based global encoder through a learnable prior-gated fusion mechanism. The proposed module adaptively regulates the influence of tissue priors across spatial locations, while an auxiliary foreground reconstruction branch preserves high-frequency cellular structures during training. In addition, auxiliary cellness-guided cues are incorporated to further improve localization robustness. Experiments on the OCELOT benchmark demonstrate consistent improvements, achieving macro F1-scores of 0.7722 on the validation set and 0.7345 on the test set, highlighting the effectiveness of adaptive prior integration for robust histopathology cell detection.
CDPM-Align: Multi-Scale Guidance-Aligned Diffusion Pretraining for Robust Few-Shot Anatomical Landmark Detection
Anatomical landmark detection is a fundamental task in medical image analysis supporting a wide range of diagnostic and interventional workflows. Although recent methods have achieved sub-millimetric localisation, accuracy alone is not sufficient for clinical deployment, requiring reliability and robustness in prediction. Despite its clinical relevance, the impact of representation learning in this context is still underexplored. In this work, we introduce CDPM-align, a multi-scale guidance-aligned conditional diffusion pre-training for anatomical landmark detection. Our experimental setup focuses on a few images and a few annotation regimes. Specifically, we employ three popular heterogeneous small-scale benchmark datasets for representation learning via conditional generative pre-training. Furthermore, we consider low-annotation scenarios for the downstream task of landmark detection, with 10 and 25 annotated images, reflecting realistic trade-offs between clinical effort and resource constraints for annotations. Our results confirm that generative pre-training enables the model to learn a robust representation. This improves both accuracy and uncertainty on the downstream tasks, advancing towards safe and efficient clinical deployment.
A unified multi-task framework enables interpretable chest radiograph analysis
While multimodal deep learning has advanced medical imaging analysis, existing black-box systems \textcolor{black}{may remain confined to isolated tasks, often overlooking} the trust-sensitive nature of clinical diagnosis as a multi-task process. We propose IMT-CXR (Interpretable Multi-task Transformer for Chest X-ray Analysis), a framework that emulates radiologists' diagnostic workflow through three evidence-driven stages: 1) Disease recognition; 2) Attribute characterization (e.g., size, location, severity quantification); 3) Evidence-integrated report generation with traceable decision pathways. The framework employs a unified transformer architecture optimized via medical-domain instruction tuning, sequentially executing four clinical tasks: multi-label disease classification, lesion localization, anatomical segmentation, and radiology report generation. Experimental validation demonstrates competitive performance on ten CXR benchmarks under direct inference and fine-tuning settings. In a blinded evaluation of 160 historical reports from four medical centers, three radiologists rated 66% of AI-generated reports as comparable to or surpassing original clinical reports in diagnostic clarity, highlighting the framework's translational potential. By establishing traceable diagnostic pathways from anatomical findings to conclusions, this work bridges the gap between AI technical metrics and clinical utility, advancing trustworthy AI systems in medical imaging.
Attenuation-Resilient Alternating Optimization for Laparoscopic Liver Landmark Detection
Liver surface landmark detection is a fundamental prerequisite for anatomical guidance in laparoscopic liver surgery. However, it remains unreliable in practice due to two pervasive challenges: illumination attenuation in underexposed regions and the structural mismatch between pixel-wise localization and continuous curvilinear geometry. To address these limitations, we propose A2ONet, an attenuation-resilient alternating optimization network for robust liver landmark detection. To mitigate illumination attenuation, A2ONet embraces an illumination field compensation (IFC) block that adaptively enhances dark regions while preserving structural consistency. Meanwhile, we introduce a lightweight frequency-orientation selective filter (FOSF) to suppress repetitive texture interference and preserve salient curvilinear cues. Building upon these resilient representations, we design an alternating seg-curve optimization (ASCO) decoder that iteratively couples dense segmentation with explicit curve modeling, enabling mutual guidance to optimize both structural continuity and endpoint localization. Extensive evaluations on L3D-2K, L3D, and P2ILF demonstrate consistent improvements over competitive methods, establishing a more reliable foundation for intraoperative anatomy guidance. Our code will be available at https://github.com/hyperiondk115/A2ONet.
Aligning Cellular Sheaves with Classifier Attention for Interpretable Weakly-Supervised Pathology Localization
Weakly-supervised classification of whole-slide images with attention-based multiple instance learning (ABMIL) on top of foundation features now reaches near-saturation on Camelyon16 slide-level performance, but the corresponding attention maps are an imperfect localization signal: in clinical interpretation, a model that classifies correctly without firing on the actual lesion is hard to trust. We address this gap with cellular sheaves, which equip each vertex and edge of a graph with a finite-dimensional vector space and consistent linear maps between them, providing a principled way to detect local disagreement on graph-structured data. We apply cellular sheaves to weakly-supervised tumour localization on whole-slide images, combining a sheaf disagreement field with ABMIL. The natural training objective, encouraging consistency between similar features, produces a disagreement field that tracks tissue-level texture rather than diagnostic content. We propose attention-conditional consistency, which uses the classifier's attention to define which neighbouring patches should agree. Joint training of the classifier and the sheaf under this objective produces a disagreement field with patch-level AUC 0.940 on Camelyon16 and raises the attention head from its ABMIL-alone level of 0.717 to 0.953. Two-stage ablation with the classifier frozen at its ABMIL values reaches only 0.727 on the disagreement field and leaves attention at 0.717, confirming that the gain comes from the projector co-adapting under both objectives, not from the loss change in isolation. The trained model transfers without retraining to annotated slides from Camelyon17, maintaining Delta AUC 0.932 +/- 0.083 and attention AUC 0.955 +/- 0.099. The result is an attention map and a sheaf-disagreement map that fire on the same diagnostic regions, giving clinicians two complementary explanations for each slide-level prediction.
GLeVE: Graph-Guided Lesion Grounding with Proposal Verification in 3D CT
Grounding radiology report descriptions to 3D CT volumes is essential for verifiable clinical interpretation, yet remains challenging due to the semantic-spatial gap between free-text narratives and volumetric anatomy. Existing report-assisted and vision-language grounding methods typically rely on phrase-level alignment or dense pixel supervision, resulting in limited lesion-wise correspondence and suboptimal localization accuracy. We propose GLeVE, a graph-guided lesion grounding framework with anatomical prior verification and octree-based autoregressive refinement. GLeVE treats each lesion description as an atomic semantic unit and encodes organ attribution, attributes, and inter-lesion relations through relation-aware graph reasoning to produce discriminative lesion-wise queries. Anatomy-aware proposal generation with region-level verification enforces one-to-one text-lesion alignment, while hierarchical octree refinement progressively improves boundary delineation. Experiments on AbdomenAtlas 3.0 demonstrate consistent gains over classical multimodal foundation models and report-supervised baselines in both segmentation accuracy and lesion-level localization.
Physiology and Anatomy Aware Inverse Inference of Myocardial Infarction for Cardiac Digital Twin
Accurate localization of myocardial infarction is essential for risk stratification. While LGE-MRI remains the gold standard, it is resource-intensive. Integrating cine MRI with ECG enables a more detailed representation of infarct properties. Existing inverse MI inference methods overlook realistic scar morphology and cardiac repolarization, reducing sensitivity to subtle ECG variations and interpretability of infarct-induced electrophysiological changes. In this paper, we propose a novel framework for noninvasive MI localization using cardiac digital twins. To bridge the domain gap between simulation and reality, we introduce an anatomy-aware stochastic infarct synthesis strategy to synthesize realistic, irregular scars with border zones, mimicking ischemic transmural progression. We then construct a virtual cohort to simulate QRS-T waveforms, capturing both depolarization and repolarization dynamics. Furthermore, we design a Physiology and Anatomy Aware Network (PAA-Net) that jointly encodes 3D myocardial geometry and multi-lead ECGs to infer infarct areas with varying localizations, sizes, spatial extents, and transmuralities. Experimental results demonstrate that our framework significantly outperforms existing methods in inverse inference, achieving Dice scores of 0.7391 and 0.5503 for scar and border zone segmentation, respectively, while further enhancing the interpretability of the ECG-infarct relationship. Our code will be released upon acceptance.
Look-Closer-Then-Diagnose: Confidence-Aware Ultrasound VQA via Active Zooming
Vision-Language Models (VLMs) have significantly advanced medical visual question answering, yet their performance in ultrasound remains suboptimal. In clinical practice, sonographers explicitly focus on lesion regions to formulate reports, though diagnostic interpretations sometimes vary due to inherent subjectivity. However, existing VLMs are not explicitly structured to interactively zoom into lesions prior to diagnosis; moreover, they typically treat annotations as unbiased ground truths, failing to account for their inherent subjectivity and ambiguity. In this paper, we propose a framework specifically designed to consider the sonographer's cognitive workflow. We first introduce a structured Zoom-then-Diagnose paradigm, which replicates the interactive search process to enable lesion-focused reasoning. Furthermore, within the Group Relative Policy Optimization (GRPO) framework, we introduce an uncertainty-aware reward derived from stochastic group-wise rollouts to estimate prediction consistency as a proxy for model confidence. Together, these two components encourage the model to reinforce accurate predictions on clear cases while remaining cautious under ambiguity. Experiments across liver, breast, and thyroid datasets show that our framework improves lesion localization by 39.3%, demonstrating that our model has learned the ability to actively look closer and diagnose.
Segmentation, Detection and Explanation: A Unified Framework for CT Appearance Reasoning
Recent progress in deep learning has significantly advanced CT image analysis, particularly for segmentation tasks. However, these advances are largely confined to image-level pattern recognition, with most methods lacking explicit anatomical or contextual reasoning. Large vision-language models introduce linguistic context into image analysis, yet most approaches typically focus on a single task, which is insufficient for clinical workflow analysis that requires multiple fine-grained types of analysis, such as anatomy detection and segmentation. In this paper, we propose a unified autoregressive framework that integrates language-guided visual reasoning into CT interpretation. Our method introduces task-routing tokens that trigger detection and segmentation heads conditioned on the hidden states of a large vision-language model, enabling coherent generation of visual outputs (e.g., masks and bounding boxes) and textual reasonings. To progressively enhance localisation accuracy and semantic clarity, we further design a "closer-look" mechanism that allows the model to perform progressive coarse-to-fine visits to regions of interest under refined fields of view. To support model training and evaluation, we curated a new multimodal CT dataset containing pixel-wise masks, bounding boxes, spatial prompts, and structured descriptions for visual objects constructed through an AI-assisted annotation process with human verification. Experiments on public benchmarks demonstrate consistent improvements over the SoTA, achieving up to 1.0% Dice on BTCV and 1.7% Dice on MosMed+, while additionally providing appearance reasoning outputs. The code and dataset will be available.
Diffusion Attention Expert Model for Predicting and Semi-automatic Localizing STAS in Lung Cancer Histopathological Images
Accurate intraoperative and postoperative diagnosis of spread through air spaces (STAS) is essential for guiding surgical decisions and postoperative management in lung cancer. However, histopathological assessment is labor-intensive and is prone to missed or incorrect diagnoses. We propose a Diffusion Attention Expert Model (DAEM) to detect STAS in frozen sections (FSs) and paraffin sections (PSs). Its diffusion attention expert module leverages full attention aggregation to learn multi-scale features from histopathological images, while a dual-branch architecture strengthens multi-scale feature representation. On an internal dataset, DAEM achieves AUCs of 0.8946 for FSs and 0.9112 for PSs. Validation on external multi-center datasets from eight institutions demonstrates strong generalizability and interpretability. Using tumor microenvironment (TME) features in PSs, we further enable semi-automatic measurement of STAS location and its distance from the primary tumor. Several quantitative TME metrics are identified as potential biomarkers for STAS, including micropapillary-type STAS. Overall, DAEM offers a clinically actionable framework for STAS assessment by enabling accurate and interpretable detection on FSs and PSs, supporting postoperative risk stratification through quantitative TME-based analysis.
Evidential Reasoning Advances Interpretable Real-World Disease Screening
Disease screening is critical for early detection and timely intervention in clinical practice. However, most current screening models for medical images suffer from limited interpretability and suboptimal performance. They often lack effective mechanisms to reference historical cases or provide transparent reasoning pathways. To address these challenges, we introduce EviScreen, an evidential reasoning framework for disease screening that leverages region-level evidence from historical cases. The proposed EviScreen offers retrospection interpretability through regional evidence retrieved from dual knowledge banks. Using this evidential mechanism, the subsequent evidence-aware reasoning module makes predictions using both the current case and evidence from historical cases, thereby enhancing disease screening performance. Furthermore, rather than relying on post-hoc saliency maps, EviScreen enhances localization interpretability by leveraging abnormality maps derived from contrastive retrieval. Our method achieves superior performance on our carefully established benchmarks for real-world disease screening, yielding notably higher specificity at clinical-level recall. Code is publicly available at https://github.com/DopamineLcy/EviScreen.
Towards Real-Time Autonomous Navigation: Transformer-Based Catheter Tip Tracking in Fluoroscopy
Purpose: Mechanical thrombectomy (MT) improves stroke outcomes, but is limited by a lack of local treatment access. Widespread distribution of reinforcement learning (RL)-based robotic systems can be used to alleviate this challenge through autonomous navigation, but current RL methods require live device tip coordinate tracking to function. This paper aims to develop and evaluate a real-time catheter tip tracking pipeline under fluoroscopy, addressing challenges such as low contrast, noise, and device occlusion. Methods: A multi-threaded pipeline was designed, incorporating frame reading, preprocessing, inference, and post-processing. Deep learning segmentation models, including U-Net, U-Net+Transformer, and SegFormer, were trained and benchmarked using two-class and three-class formulations. Post-processing involved two-step component filtering, one-pixel medial skeletonization, and greedy arc-length path following with contour fall-back. Results: On manually-labeled moderate complexity fluoroscopic video data, the two-class SegFormer achieved a mean absolute error of 4.44 mm, outperforming U-Net (4.60 mm), U-Net+Transformer (6.20 mm) and all three-class models (5.19-7.74 mm). On segmentation benchmarks, the system exceeded state-of-the-art CathAction results with improvements of up to +5% in Dice scores for three-segmentation. Conclusion: The results demonstrate that the proposed multi-threaded tracking framework maintains stable performance under challenging imaging conditions, outperforming prior benchmarks, while providing a reliable and efficient foundation for RL-based autonomous MT navigation.
ImplantMamba: Long-range Sequential Modeling Mamba For Dental Implant Position Prediction
In the design of surgical guides for implant placement, determining the precise implant position is a critical step. However, the implant region itself is often characterized by a lack of distinctive texture in medical images. Consequently, artificial intelligence (AI) models must infer the correct implant position and angulation (slope) primarily by analyzing the texture of the surrounding teeth, which poses a significant challenge. To address this, we propose ImplantMamba, a network architecture designed for long-range sequential modeling to integrate texture information from adjacent teeth. Our approach explicitly couples the regression of the implant position with its slope. The core of ImplantMamba is a hybrid encoder that combines Convolutional Neural Networks (CNNs) with Mamba layers. This design enables the network to hierarchically extract local anatomical features through CNNs while simultaneously modeling global contextual dependencies across the entire scan volume via Mamba's selective scan operations, leading to a more comprehensive understanding of the implant site. Furthermore, we introduce a Slope-Coupled Prediction Branch (SCP). This branch is designed to connect the prediction of implant position with the slope, ensuring internal consistency and anatomical plausibility by thereby enforcing a coherent relationship between the predicted implant location and its angulation. Extensive experiments on a large-scale dental implant dataset demonstrate that the proposed ImplantMamba achieves superior performance compared to existing methods.
Bridging visual saliency and large language models for explainable deep learning in medical imaging
The opaque nature of deep learning models remains a significant barrier to their clinical adoption in medical imaging. This paper presents a multimodal explainability framework that bridges the gap between convolutional neural network (CNN) predictions and clinically actionable insights for brain tumor classification, leveraging large language models (LLMs) to deliver human-interpretable diagnostic narratives. The proposed framework operates through three coupled stages. First, nine CNN architectures are extended with a dual-output hybrid formulation that simultaneously optimises a classification head and a segmentation head, enabling spatially richer feature learning. Second, visual saliency attribution methods, namely Grad-CAM, Grad-CAM++, and ScoreCAM, are applied to generate class-discriminative heatmaps, which are subsequently refined into binary tumor masks via an adaptive percentile thresholding pipeline. Third, the resulting masks are mapped onto the Harvard-Oxford cortical atlas to translate pixel-level evidence into named neuroanatomical structures, and the extracted findings are encoded into a structured JSON file that conditions three LLMs (Grok3, Mistral, and LLaMA) to generate coherent, radiological-style diagnostic reports. Evaluated on a dataset of 4,834 contrast-enhanced T1-weighted brain MRI images spanning three tumor classes, InceptionResNetV2 achieved the highest classification performance and Grad-CAM++ yielded the best segmentation overlap. Among the language models, Grok3 led in lexical diversity and coherence, while LLaMA achieved the highest readability score. By integrating visual, anatomical, and linguistic modalities into a unified pipeline, the framework produces explanations that are technically grounded and meaningfully interpretable, advancing the transparency and clinical accountability of artificial intelligence assisted brain tumor diagnosis.
Tracing Like a Clinician: Anatomy-Guided Spatial Priors for Cephalometric Landmark Detection
Clinicians trace cephalometric radiographs following a structured anatomical workflow, yet no prior system encodes this into computation. We present a five-phase anatomy-guided pipeline producing confidence-weighted spatial priors that shape HRNet-W32 training, achieving 1.04 mm mean radial error on 25 landmarks across 1,502 radiographs from 7+ imaging devices. A training x inference prior matrix isolates the mechanism: anatomical priors maintain a 1% validation-to-test gap versus 88% without priors (1.94 mm), despite identical validation convergence. The matrix establishes that all trained models are inference-independent, the expanded architecture alone provides no benefit, random priors yield partial but unstable improvement (1.72 mm), and only image-specific anatomically correct priors produce the 1.04 mm result -- functioning as a training-time regularizer requiring no automated prior generation at deployment. Five-fold cross-validation (p=0.0015), patient-level permutation testing (p<0.0001, n=151), quantified Grad-CAM analysis (88% vs. 74% in-zone activation, p<0.001), and clinical measurement validation (skeletal classification kappa=0.79-0.84, zero Class II<->III reversals, ICC>0.95) provide converging evidence. Cross-domain experiments on echocardiography, cervical spine, and hand radiography support the hypothesis that prior effectiveness scales with the spatial entropy of the landmark distribution.
Reconstruction Interval Z-Phase Dependence of AI Detection Sensitivity in CT Lung Nodule Screening
Background: Sensitivity of AI-assisted lung nodule detection systems is known to vary with CT acquisition parameters including radiation dose, reconstruction kernel, and slice thickness. However, the dependence of detection probability on nodule position within the reconstruction cycle -- the z-phase -- has not, to the author's knowledge, been characterized for deep learning-based detection systems. Methods: A retrospective analysis was performed using the LIDC-IDRI dataset. Detection results from a previously validated 154-case perturbation study were re-analyzed. For each consensus nodule (>=4-reader agreement), z-phase was defined as the fractional position of the nodule center within the reconstruction cycle, folded to [0, 0.5]. Detection sensitivity was stratified by z-phase bin, reconstruction interval (1mm, 3mm, 5mm), and by the ratio of reconstruction interval to nodule diameter (d/D). Results: At 5mm reconstruction interval, sensitivity was 71.6% vs 84.8% at 1mm baseline. Within the 5mm condition, sensitivity varied by 17.6 percentage points across z-phase bins. Stratified by d/D ratio, sensitivity was 92.4% for d/D < 0.5, 78.0% for 0.5 <= d/D < 1.0, and 61.4% for d/D >= 1.0, with a systematic z-phase effect present only in the d/D >= 1.0 stratum. Conclusions: AI detection sensitivity depends on the ratio of reconstruction interval to nodule diameter. When this ratio approaches or exceeds 1.0 -- as occurs for 3-6mm nodules at 5mm reconstruction -- z-phase becomes the dominant source of per-study detection variance. This stochastic effect is invisible to protocol-level quality metrics and not reflected in AI confidence scores.
Echo-α: Large Agentic Multimodal Reasoning Model for Ultrasound Interpretation
Ultrasound interpretation requires both precise lesion localization and holistic clinical reasoning, yet existing methods typically excel at only one of these capabilities: specialized detectors offer strong localization but limited reasoning, whereas multimodal large language models (MLLMs) provide flexible reasoning but weak grounding in specialized medical domains. We present Echo-α, an agentic multimodal reasoning model for ultrasound interpretation that unifies these strengths within an invoke-and-reason framework. Echo-α is trained to coordinate organ-specific detector outputs, integrate them with global visual context, and convert the resulting evidence into grounded diagnostic decisions beyond detector-only inference. This behavior is established through a nine-task supervised curriculum and then refined by sequential reinforcement learning under different reward trade-offs, yielding Echo-α-Grounding for lesion anchoring and Echo-α-Diagnosis for final diagnosis. On multi-center renal and breast ultrasound benchmarks, Echo-α outperforms competitive baselines on both grounding and diagnosis. In particular, on cross-center test sets, Echo-α-Grounding attains 56.73%/43.78% [email protected] and Echo- α-Diagnosis reaches 74.90%/49.20% overall accuracy on renal/breast ultrasound. These results suggest that agentic multimodal reasoning can turn specialized detectors into verifiable clinical evidence, offering a practical route toward ultrasound AI systems that are more accurate, interpretable, and transferable. The repository is at https://github.com/MiliLab/Echo-Alpha.
GAZE: Grounded Agentic Zero-shot Evaluation with Viewer-Level Tools and Literature Retrieval on Rare Brain MRI
Vision-language models (VLMs) read an image and produce text in a single forward pass, whereas radiologists typically inspect an image several times and consult the literature before writing a report. We introduce GAZE (Grounded Agentic Zero-shot Evaluation), a framework that lets a medical VLM work in this iterative way by calling viewer-level tools (zoom, windowing, contrast, edge detection) and two retrieval tools backed by the U.S. National Library of Medicine (PubMed for medical literature, Open-i for radiological images), with structured outputs validated against a schema and full tool-call traces recorded for auditability. On NOVA, a benchmark of 906 brain MRI cases covering 281 rare neurological conditions, GAZE reaches 58.2 mean average precision (mAP) at intersection-over-union (IoU) 0.3 for lesion localisation and 34.9% Top-1 diagnostic accuracy under a joint protocol that scores captioning, diagnosis, and localisation from the image alone, without task-specific fine-tuning. Before any tool is used, structured prompting and schema-validated outputs already improve over the published Gemini 2.0 Flash baseline (20.2 to 29.4 [email protected]), so framework design is itself an experimental variable. Tool use helps rare pathologies disproportionately: the fraction of cases with IoU > 0.3 rises from 17% to 58% for diagnoses with three or fewer examples versus 25% to 68% for common conditions (10 cases), with gains tracking engagement (Gemini 3 Flash: Cohen's d = 0.79, 11.8 tool calls per case; Gemini 2.0 Flash: tools used in 8.2% of cases, no significant benefit). Retrieval ablations additionally reveal a model-dependent trade-off in which gains in diagnosis can coincide with losses in localisation, reinforcing the case for joint evaluation of diagnosis, localisation, and captioning in medical VLMs.
Autonomous Skeletal Landmark Localization towards Agentic C-Arm Control
Purpose: Automated C-arm positioning ensures timely treatment in patients requiring emergent interventions. When a conventional Deep Learning (DL) approach for C-arm control fails, clinicians must revert to manual operation, resulting in additional delays. Consequently, an agentic C-arm control framework based on multimodal large language models (MLLMs) is highly desirable, as it can incorporate clinician feedback and use reasoning to make adjustments toward more accurate positioning. Skeletal landmark localization is essential for C-arm control, and we investigate adapting MLLMs for autonomous landmark localization. Methods: We used an annotated synthetic X-ray dataset and a real X-ray dataset. Each X-ray in both datasets is paired with several skeletal landmarks. We fine-tuned two MLLMs and tasked them with retrieving the closest landmarks from each X-ray. Quantitative evaluations of landmark localization were performed and compared against a leading DL approach. We further conducted qualitative experiments demonstrating: (1) how an MLLM can correct an initially incorrect prediction through reasoning, and (2) how the MLLM can sequentially navigate the C-arm toward a target location. Results: On both datasets, fine-tuned MLLMs demonstrate competitive performance across all localization tasks when compared with the DL approach. In the qualitative experiments, the MLLMs provide evidence of reasoning and spatial awareness. Conclusion: This study shows that fine-tuned MLLMs achieve accurate skeletal landmark localization and hold promise for agentic autonomous C-arm control. Our code is available athttps://github.com/marszzibros/C-arm-localization-LLMs.git