Magnetic Resonance Imaging

Recent momentum

emerging

0 papers in the last 28 days · 0.0% of indexed attention

Twelve weeks of publication activity for this topic as it is defined today.

Weekly history

Recent digests

What was published in this field, kept on the site without email delivery.

Period ending 2026-09-21

11 new papers

A weekly snapshot of new work published in Magnetic Resonance Imaging.

Period ending 2026-09-14

9 new papers

A weekly snapshot of new work published in Magnetic Resonance Imaging.

Period ending 2026-09-07

7 new papers

A weekly snapshot of new work published in Magnetic Resonance Imaging.

Inside this field

Focused directions

351 papers

Latest in Magnetic Resonance Imaging

Sep 22, 2026cs.CV

Anatomy-Aware Synthesis of Post-Contrast Breast MRI from Pre-Contrast Images

We developed an anatomy-aware deep learning framework to synthesize post-contrast breast MRI from pre-contrast images, emphasizing tumor and background parenchymal enhancement (BPE) regions. This retrospective study included 649 patients with 6,251 paired pre-contrast and post-contrast images. The framework integrates breast mask consistency, lesion-region supervision, and BPE-region supervision into an image-to-image translation model. Evaluation included quantitative image quality metrics, a reader study with two breast radiologists, and downstream Ki-67 classification. The proposed method outperformed Pix2Pix, Pix2PixHD, diffusion-based synthesis, and mask-supervised baselines in whole-image and regional evaluations. Ki-67 classification showed no statistically significant performance differences across real- and synthetic-image training and testing settings, although this does not establish equivalence. These findings suggest that anatomy-aware supervision improves synthesis fidelity and support further investigation of synthetic post-contrast MRI for contrast-free imaging workflows.
Zhengbo Zhou, Dooman Arefan, Lin Gu +2
Sep 21, 2026cs.CV

MIGA:Shared-Geometry Gaussian Representation with Implicit Amplitude Modeling for Accelerated 3D Multi-Echo MRI

Three-dimensional multi-echo MRI provides rich anatomical and quantitative information, but repeated volumetric encoding prolongs acquisition and motivates k-space undersampling. Reconstructing undersampled multi-echo data requires exploiting shared anatomy while preserving echo-dependent signal variation; full-volume modeling also introduces substantial computational and memory demands. We propose MIGA, a scan-specific framework comprising shared anisotropic Gaussian geometry, a coordinate-conditioned multi-output amplitude network, and explicit echo-specific phase variables. The Gaussian geometry provides common spatial support across echoes, the implicit network models spatially structured amplitude variations, and the phase variables retain echo-specific complex signal information. All components are jointly optimized using only the acquired multi-coil k-space, requiring no fully sampled training data. Experiments showed that MIGA consistently outperformed the comparison methods across imaging tasks and acceleration factors, with larger improvements under stronger undersampling. MIGA also achieved a favorable quality-cost balance among the evaluated full-volume multi-echo methods. These results support the effectiveness of combining shared Gaussian geometry with implicit echo-dependent amplitude modeling for accelerated 3D multi-echo MRI reconstruction.
Jingran Xu, Yuanyuan Liu, Yanjie Zhu
Sep 21, 2026cs.CV

WebMRIQC: A Web-Based Implementation of MRIQC for Accessible MRI Image Quality Assessment in Resource-Constrained Settings

Reliable quality control (QC) of magnetic resonance imaging (MRI) is essential for reliable diagnostic neuroimaging, yet standard manual assessment is subjective and time-consuming. MRIQC has established standardized automated extraction of image-quality metrics (IQMs), but its reliance on local computational imaging skills and capacity including high-performance computing, limits its adoption in resource-constrained settings (RCS). We present WebMRIQC (webmriqc.mailab.io), an open-source browser-based platform that wraps the validated MRIQC engine behind a zero-installation web interface. WebMRIQC automates the DICOM-to-BIDS conversion of de-identified MRI scans, executes the unmodified containerized MRIQC pipeline on a shared compute node governed by a fair-share job queue, and returns an interactive in-browser dashboard. The dashboard grounds every IQM in published quality thresholds, benchmarks each scan against the normative distribution of high-resource open datasets, and supports cross-site multicentre implementation of optimized scan protocols in RCS.We describe the system architecture and a validation framework establishing measurement equivalence between WebMRIQC and native MRIQC across thirteen IQMs on the BraTS-Africa and BraTS 2021 datasets. Preliminary results indicate strong agreement for contrast-, signal and noise-based metrics, demonstrating that web-based implementation lowers the barrier to standardized MRI QC and provides a foundation for harmonized, regionally adapted quality benchmarks across RCS imaging sites. The code is publicly available here https://github.com/CAMERA-MRI/WebMRIqc.
Philip Nkwam, Ifeoluwa Oladeji, Sekinat Zurakat-Aderibigbe +9
Sep 21, 2026cs.CV

Evaluating the Generalization of Neuroimaging Foundation Models on African Brain MRI

Neuroimaging foundation models pretrained on large, predominantly western cohorts are increasingly proposed as general-purpose backbones for brain MRI analysis. Yet, their ability to generalize to underrepresented clinical populations remains largely untested. We evaluate four recent foundation models (BrainIAC, Neuro-JEPA, NeuroVFM, and Primus) on a three-way diagnostic classification task (Control, Dementia, Parkinson's disease) using a cohort of 88 subjects from a Nigerian clinical brain MRI dataset, across four modality configurations (T1w, T2w, T1w+T2w, FLAIR), and compare against an end-to-end trained ViT3D baseline. The frozen backbones collapse to majority-class predictions, while Neuro-JEPA on FLAIR shows modest but still limited discrimination. In contrast, the end-to-end trained ViT3D achieves higher accuracy and MCC on every task (up to 53.4% accuracy, MCC=0.27) and is the only model with non-trivial recall. Our findings suggest that these frozen neuroimaging foundation models are insufficient for fine-grained diagnostic classification in small, non-western clinical cohorts, motivating parameter-efficient adaptation and broader multi-site external validation for equitable deployment in global health settings.
Oluwatobi Iyanuoluwa Akinmuleya, Olatokun Shamsudeen Akano, Samuel Danquah Ankapong +2
Sep 17, 2026cs.CV

A Dual-Stream Regulated Reconstruction and Segmentation Network with Hierarchical Artifact-Prior Modeling for Ultra-Low-Field Pediatric Neuroimaging

Automated quality assessment, enhancement, and segmentation of multiple structures in 0.064T0.064\,\mathrm{T} ultra-low-field pediatric MRI are limited by a low signal-to-noise ratio, weak anatomical boundaries, and frequent artifacts. We present a unified framework for the LISA 2026 Challenge that performs all three tasks together within one inference pipeline. A network with two coupled streams, built on a 3D U-Net, first reconstructs an enhanced uLF volume and then combines the original and enhanced images for subcortical segmentation. To improve boundary stability, we add an auxiliary class covering brain tissue outside the target structures, derived from whole brain masks. A head conditioned on an artifact graph predicts the seven artifact ratings from reconstruction residuals and frozen segmentation features. We address the scarcity of dense annotations using diffeomorphic registration from atlas to target for label propagation and to regularize anatomical reconstruction. We report validation results across all three tasks.
Bahram Jafrasteh, Leo Milecki, Qingyu Zhao
Sep 17, 2026cs.CV

Fast Cross-Strength Multi-Contrast Brain MRI Translation using Latent Bridge Matching

Magnetic Resonance Imaging (MRI) acquired at different field strengths exhibits pronounced variation in noise, resolution, homogeneity, and contrast, which limits comparability across acquisition settings and complicates downstream analysis. We address this with a unified conditional model for controllable field-to-field synthesis, built on the framework of conditional latent bridge matching. Our single model achieves highly competitive results across the validation phase for all three tasks of the MRIxFields2026 challenge without task-specific architectures or training. We achieve fast generation with only a single inference step, producing all modality and field-strength combinations for 3030 axial slices in under 9090 seconds, as well as cross-modality-strength translation for a full volume in under 7070 seconds, on a single NVIDIA A5000 GPU. We further provide extensive ablations regarding different components of our solution. Code: https://gitlab.com/siddharthsrivastava/mrixfields-2026
Siddharth Srivastava, Till Bretschneider
Sep 17, 2026cs.CV

Bridging Modalities on the Cortex: Surface-based MRI to PET Translation with a Diffusion Bridge

Cortical hypometabolism measured by Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is a highly sensitive biomarker for dementia diagnosis. However, high costs, radiation exposure, and limited accessibility constrain its clinical utility. While cross-modal synthesis from Magnetic Resonance Imaging (MRI) offers a promising alternative, existing volumetric generation methods do not explicitly account for the highly folded cortical geometry, where disease-related patterns predominantly reside. To address this, we introduce a novel surface-based diffusion bridge framework DB-SUiT for MRI-to-PET translation that operates natively on the cortical manifold. A conditional Spherical U-shaped vision Transformer (SUiT) is specifically designed to model the intricate cross-modal relationships while preserving surface topology. It combines spherical convolutional encoders for multi-scale surface feature extraction with bottleneck Transformers to capture long-range spatial dependencies, while incorporating demographic and subcortical conditions to refine the synthesis. Evaluated on two datasets, including subjects with different dementia types, DB-SUiT demonstrates high-fidelity synthesis that substantially outperforms other baselines. In automated dementia classification, synthesized PET surfaces improve performance over MRI by 14.2% and PET volumes by 11.3%, approaching the performance of real PET surfaces. In a blinded reader study, synthetic PET achieved 85.5% diagnostic accuracy, compared with 75.8% for MRI and 95.2% for real PET. This further demonstrates cross-cohort and cross-pathology generalization, as the model was evaluated without retraining on an external cohort that included a dementia subtype not represented during training. Our code is available at https://github.com/ai-med/DB-SUiT.
Yitong Li, Alexandra Samoylova, Fabian Bongratz +4
Sep 16, 2026eess.SP

Stable Filters for Generative Modeling of Graph Signals

Generating signals on graphs requires permutation-equivariant models that exhibit stability with respect to relative structural perturbations. While recent graph-aware Schrödinger bridge models incorporate topology information directly into their reference dynamics, it is unclear how perturbations of the graph propagate through these dynamics and affect the resulting generated distributions. In this paper, we analyze the structural stability of graph-aware continuous-time generative models whose drift combines a graph filter with a learned graph neural network. We derive explicit Wasserstein stability bounds that quantify the effect of relative graph perturbations on the generated distributions. Motivated by these bounds, we introduce a principled framework for designing stable graph filters that preserve the smoothing behavior of graph heat diffusion, while boosting structural stability. Experiments on synthetic and fMRI signals show our stable filters enhance structural robustness while matching or exceeding the generative quality of the heat equation baseline.
Martin Schmidt, Gonzalo Mateos
Sep 15, 2026cs.CV

NeuroTS-Net: Multi-Class Semantic Segmentation of Pediatric Brain Tumors in Multi-Modal MRI

Pediatric brain tumors are a leading cause of cancer-related mortality in children, and their small, rare, and often low-contrast subregions make accurate manual delineation challenging. Reliable automated segmentation is therefore needed to support diagnosis, treatment planning, and response assessment. Accordingly, we introduce NeuroTS-Net, a three-dimensional encoder-decoder convolutional neural network architecture for multi-class semantic segmentation that incorporates a dual-scale raw-detail stream, adaptive low-resolution context selection, and detail-preserving multipath downsampling. These components preserve fine intensity and boundary information while efficiently modeling broader tumor context. NeuroTS-Net was trained on the BraTS 2026 pediatric dataset without external data or pretrained weights and evaluated against nnU-Net and MedNeXt under the same experimental protocol. NeuroTS-Net outperformed the baseline methods, achieving whole-tumor and tumor-core Dice scores of 0.938 and 0.937 on the internal validation set and 0.927 and 0.926 on the official challenge validation set. The code is open-sourced at: https://github.com/maenstru56/NeuroTS.
Darius Peteleaza, Razvan-Gabriel Dumitru, Bogdan Neamtu +3
Sep 15, 2026cs.CV

A Vision-Language Foundation Model for Precise and Comprehensive Brain Tumor Diagnosis from Preoperative Multimodal Data

We developed BrainVLM to classify all 12 World Health Organization (WHO) 2021 brain tumor types. BrainVLM integrates an uncertainty quantification strategy to indicate prediction reliability and a module for generating radiology reports to elucidate the clinical rationale. BrainVLM was trained on multi-modal data (MRI scans, demographics, and radiology reports) from 40,043 individuals. It was validated on 5,211 patients with pathologically confirmed brain tumors, including 3,877 held-out patients from the primary hospital and 1,334 patients from 11 independent hospitals. We further conducted two proof-of-concept studies to validate its clinical utility in AI-clinician workflows: 1) a blinded multireader study where 12 neuroradiologists across varying experience levels interpreted 248 retrospective cases with or without AI assistance, and 2) a real-world prospective study in which 1,009 patients were independently and blindly assessed by BrainVLM and radiologists before surgery. Additionally, we demonstrated BrainVLM's utility in preoperative molecular subgroup prediction for adult-type diffuse gliomas, using a multi-center cohort of 632 patients. In primary evaluation, BrainVLM achieved an area under the curve (macro-AUC) of 0.85 (95% CI: 0.84-0.86), and an F1 score of 0.82 (95% CI: 0.81-0.83), surpassing neuroradiologists (F1 = 0.80 (95% CI: 0.79-0.81)). In external validation across 11 centers, BrainVLM achieved an AUC = 0.80 (95% CI: 0.79-0.82) and F1 = 0.75 (95% CI: 0.73-0.78), compared with F1 = 0.71 (95% CI: 0.69-0.73) for neuroradiologists. In prospective real-world evaluation, BrainVLM maintained performance comparable to neuroradiologists.
Yinong Wang, Jianwen Chen, Zhou Chen +28
Sep 14, 2026cs.CV

Anatomical Grounding and Leakage-Aware Multimodal Contrastive Learning for Alzheimer's Disease Classification from Structural MRI

Deep networks trained on structural MRI for Alzheimer's disease (AD) staging often reach reasonable accuracy while attending to anatomically irrelevant regions, and multimodal models that add clinical tables frequently rely on variables that were used to assign the diagnostic label in the first place. We study both issues with a deliberately lightweight slice-based encoder (ResNet18 with a one-layer Transformer over slices) on 1,075 baseline T1-weighted scans from ADNI-1. First, we use FastSurfer segmentations as an anatomical reference: YOLOv8 models trained on segmentation-derived labels localize Alzheimer-relevant structures with mAP_50 above 0.96, and a Grad-CAM comparison shows that the image-only classifier frequently attends to the skull, orbits and background. Second, we adapt a CLIP-style image - tabular contrastive framework and organize ADNIMERGE variables along a label-leakage spectrum. Fusion with cognitive scores yields 87.3% three-way accuracy, which we treat as a leakage-driven upper bound rather than an imaging result; fusion with regional volumes yields 73.0%. We observe that the choice of contrastive target changes what the image encoder learns: on MCI vs. CN, the image-only head reaches 52.4% when the encoder is aligned to cognitive scores and 73.8% when aligned to volumes, although no tabular input is used at inference. Third, restricting the input to a per-subject crop of the medial temporal lobe raises image-only three-way accuracy from 58.7% to 65.1%. All results come from single runs on a small balanced test set, and we report confidence intervals and the protocol differences that prevent direct comparison with published numbers.
Paul-Gabriel Nicolae, Irina Georgiana Mocanu
Sep 14, 2026cs.HC

Can a Neural Encoding Model Replicate an fMRI Visualization Study?

Most knowledge of graphical perception comes from behavioral studies. Understanding from a neural perspective is much more limited due in part to neuroimaging studies' expensiveness and difficulty to conduct. In this paper, we evaluate whether Meta's Tribe V2 neural encoding model can recover neural contrasts from a visualization fMRI study. Specifically, we evaluate Tribe V2 through a conceptual replication of the visualization-viewing component of a prior comparison of Bubble charts and three-dimensional Surface charts in color and grayscale. We generate TRIBE-predicted cortical responses for the original stimuli and compare the resulting contrasts with those reported in the human study. The model reproduced the direction of 11 of 14 reported cortical effects, with agreement concentrated in visual-processing regions. This agreement characterizes the model's alignment with the prior human-generated fMRI results rather than independently confirming them. We discuss the limitations encountered when working with this model for in-silico replication and hope to encourage future work exploring this new avenue for neuroimaging studies in visualization. Supplemental materials are available at https://osf.io/8a96x/.
Erfan Nasirzadeh Orang, Zack While
Sep 14, 2026cs.CV

Unified CT and MRI Pancreas Segmentation for Label-Efficient Cross-Modality Subregion Transfer

Robust medical image segmentation across imaging modalities is challenging because of large differences in appearance and intensity distributions. Models trained on a single modality often show substantial performance drops when applied to unseen domains. In this work, we develop a unified 3D pancreas segmentation framework that applies domain-adversarial learning to 4,604 heterogeneous CT and MRI scans to learn anatomical representations. A shared nnU-Net encoder-decoder is trained for whole-pancreas segmentation, with a latent domain discriminator encouraging CT-MRI feature alignment. The learned encoder is subsequently transferred to pancreatic head-body-tail segmentation using limited MRI-only subregion annotations. An average Dice score of 87.31% on the in-distribution test set and Dice scores ranging from 84.20% to 88.09% across external OOD datasets were achieved in whole pancreas segmentation. Dice scores of 80.53% on MRI and 83.05% on CT were achieved for downstream subregion segmentation, without using CT subregion annotations. These results demonstrate that a unified anatomical representation can support both cross-modality pancreas segmentation and label-efficient downstream transfer.
Ziliang Hong, Hongyi Pan, Halil Ertugrul Aktas +7
Sep 14, 2026cs.LG

Observation-Anchored Selective Assimilation for Longitudinal Tumor-State Proxy Forecasting in Post-Treatment Glioma

Post-treatment MRI in patients with glioma provides serial observations for updating patient-specific tumor-state proxy estimates, but variable appearances and trajectories complicate forecasting. We formulate forecasting as an observation-aware digital-twin update in which an intermediate observation anchors the patient-specific state. Among 203 patients and 594 follow-up time points, a predefined no-new-treatment criterion retained 120 of 236 candidate triplets, split into 81/24/15 training/validation/test triplets at the patient level. Each time point was represented by a continuous voxel-wise tumor-state proxy map in [0,1] derived from MRI lesion labels. A SegMamba-based single-step forecaster predicted update proposals from multimodal source-state tensors. Observation-Anchored Selective Assimilation (OASA) retained the observed intermediate proxy as the state anchor and selectively applied updates through a validation-selected tiered case-level rule and voxel-wise soft gate. We compared initial-scan forecasting, rollout without assimilation, latest-observation persistence, direct prediction, OASA, OASA + calibration, and morphological dilation. Checkpoints, OASA rules, and calibration thresholds were selected using validation data only. Across three seeds on 15 held-out test triplets, OASA maintained Dice at τ\tau = 0.2 comparable to persistence (0.6071 ±\pm 0.0025 vs. 0.6070) while yielding numerically higher Dice at τ\tau = 0.5 (0.4269 ±\pm 0.0079 vs. 0.3981), with a small RMSE increase. Calibration increased Dice at τ\tau = 0.2 to 0.6178 ±\pm 0.0025, increased false-positive (FP) support (11,836\rightarrow18,663), and reduced false-negative (FN) support (22,107\rightarrow17,536). This reflects near-threshold support calibration rather than improved biological predictive capability. Code is publicly available at https://github.com/jsudg436/longitudinal-proxy-forecasting.
Yeonjae Jung, Minwoo Shin
Sep 14, 2026cs.CV

A Multimodal Explainable Deep Learning Framework for Alzheimer's Disease Diagnosis using 3D Magnetic Resonance Imaging and Clinical Data

Dementia is a major and growing global health burden, with Alzheimer's disease (AD) accounting for most cases. Timely and accurate diagnosis is central to managing this burden and increasingly depends on integrating complementary clinical and imaging information. Multimodal deep learning can combine these modalities for AD diagnosis, but how its explanations behave across modalities, fusion strategies, and cohorts remains unclear. We developed an explainable multimodal framework pairing a 3D CNN encoder for T1-weighted MRI with a feedforward network for harmonized clinical and demographic data, comparing varied model setups on three-way and pairwise diagnostic tasks using 6,479 internal records from the ADNI and 1,703 independent records from the OASIS-3. On ADNI, the tabular-only model achieved the highest three-class AUC-ROC of 0.879 and best discriminated cognitively normal (CN) versus mild cognitive impairment (MCI; 0.903), while cross-attention performed best for MCI versus AD (0.861); CN versus AD was highly discriminative overall. On OASIS-3, the vision-only model performed best (three-class AUC-ROC 0.910); CN versus MCI remained difficult, and no fusion strategy consistently outperformed single modalities across tasks and cohorts. SHAP and Integrated Gradients identified the MMSE as the dominant tabular feature in both cohorts, with global feature rankings agreeing strongly in ADNI (ρ=0.94\rho=0.94) and OASIS-3 (ρ=0.96\rho=0.96); CAM-based explanations, however, changed with model configuration and cohort. These findings show that multimodal performance and explanations are task, modality, fusion, and cohort-dependent: a dominant cognitive signal persisted across cohorts, but feature contributions and CAM explanations did not, underscoring the need to evaluate explainability under cohort shift rather than as a stable, intrinsic property.
Yusuf Brima, Marcellin Atemkeng, Lakshmana Rao Namamula +1
Sep 11, 2026cs.CV

Brain-PACE: A Deep Siamese MRI Framework for Modelling Longitudinal Brain Acceleration

Brain age estimation has become a popular research proxy for assessing brain health and disease, yet longitudinal trajectories of brain ageing are still poorly defined, and clinical use is limited. Building on existing Siamese longitudinal frameworks, we develop Brain-Predicted Age Acceleration (Brain-PACE) to directly estimate the pace of structural brain ageing from paired T1-weighted MRI. Brain-PACE identified accelerated ageing in 42.642.6% of participants with mild cognitive impairment. Faster Brain-PACE was associated with greater functional and cognitive impairment (FAQ; r=0.35r=0.35, ADAS13; r=0.30r=0.30, CDR-SB; r=0.32r=0.32) and greater regional tau burden in the posterior cingulate (r=0.59r=0.59), precuneus (r=0.47r=0.47), and entorhinal cortex (r=0.37r=0.37). These associations were stronger than those observed when pace was calculated indirectly from repeated cross-sectional brain age estimates, suggesting that direct longitudinal modelling captures complementary information relevant to ongoing pathological change. Methodologically, Brain-PACE extends the LILAC framework by combining spatial attention with soft label distribution learning and a Cram'er distance objective, improving probabilistic performance and reducing prediction bias while providing measures of predictive uncertainty. Together, these findings support Brain-PACE as a complementary longitudinal imaging phenotype with sensitivity to relevant clinical and biological changes in early neurodegeneration.
Samuel Maddox (School of Computing Sciences, University of East Anglia), Jacob Newman (School of Computing Sciences +8
Sep 9, 2026eess.IV

Scale-Aware 3D Deep Learning for Robust Brain Metastasis Detection in Multimodal MRI

Detecting brain metastases in magnetic resonance imaging (MRI) remains challenging because lesions vary widely in size and appearance, with very small metastases occupying only a minute fraction of a three-dimensional input. We investigate whether combining different spatial fields of view (FOVs) improves lesion detection in multimodal MRI and present a scale-aware 3D deep-learning framework. The method uses independently trained 96396^3 and 64364^3 3D U-Nets whose whole-volume probability maps are combined by weighted late fusion. This design allows us to study the effect of spatial context separately from image resolution and modality choice. On a 97-patient development cohort, cross-FOV fusion improved lesion-level precision and F1 while substantially reducing false positives relative to the individual models. A same-FOV ensemble control showed that these gains were not explained solely by averaging independently trained networks, supporting a contribution from complementary spatial context. An exploratory cross-FOV agreement filter reduced false positives but did not improve overall F1. These results support cross-FOV probability fusion as a simple and computationally practical strategy for improving the precision-false-positive trade-off in 3D brain-metastasis detection.
Sylvain Jaume, Hongming Wang, Simon K. Warfield
Sep 9, 2026cs.CV

BrainTaskonomy: Learning How to Pretrain and What to Transfer in fMRI Foundation Models

fMRI foundation models increasingly aggregate heterogeneous data across brain states, cohorts, and acquisition settings, yet pretraining domains are commonly treated as a flat mixture and downstream tasks are adapted independently. We study whether measured learning relations can organize both stages without modifying the backbone. During pretraining, a lightweight Brain-DiT proxy estimates difficulty and directed facilitation across ten fMRI domains, yielding a priority-guided cumulative domain curriculum combined with high-to-low-noise timestep scheduling and joint consolidation. During adaptation, controlled first- and higher-order transfer across fifteen tasks constructs a directed taskonomy, from which budgeted integer programming (BIP) selects directly supervised source tasks and target-specific routes. The joint priority-domain and high-to-low-timestep curriculum reduces v-NMSE, PSD-NMSE, and FC-MSE by 6.5%, 16.3%, and 10.5%, respectively, relative to uniform sampling over both dimensions, and shows strong downstream performance across six in- and out-of-domain tasks. The taskonomy reveals asymmetric, target-dependent transfer, while exploratory sealed-test evaluation shows larger descriptive gains for BIP policies when higher-order route spaces are available than for matched random controls. Together, these findings support organizing fMRI pretraining and adaptation by measured learning relations rather than treating domains and tasks as independent flat sets.
Junfeng Xia, Wenhao Ye, Junxiang Zhang +3
Sep 8, 2026cs.CV

Longitudinal tracking of multiple sclerosis lesions in the spinal cord: A validation study

Longitudinal characterization of multiple sclerosis (MS) lesions remains constrained by the lack of frameworks capable of establishing consistent instance-level correspondences across time. Conventional segmentation approaches produce semantic lesion masks at each visit and therefore fail to capture the complex instance temporal patterns associated with lesion appearance, disappearance, splitting, or merging. This study presents a comparative evaluation of five strategies for automated tracking of spinal cord MS lesions in longitudinal MRI data from a multi-site cohort. The investigated strategies rely either on deformable registration or on a spinal anatomical reference system, and encompass overlap-based matching, coordinate-based Hungarian algorithm, gradient-boosted classification, and Siamese model classification. Tracking accuracy is quantified using instance-level true positives, false positives, and false negatives, allowing to assess the presence of one-to-many and many-to-one associations. Results show best performance for the registration-based overlap method. This study provides the first systematic analysis of lesion-instance correspondence in the spinal cord and outlines the strengths and limitations of registration-based and registration-free paradigms for longitudinal MS assessment. The code is available at http://github.com/ivadomed/longitudinal-sc-ms-lesion-tracking .
Pierre-Louis Benveniste, Julian McGinnis, Shannon Kolind +11
Sep 3, 2026cs.CV

RARF: Region-Aware Rectified Flows for 3D Brain MRI Inpainting

Medical image inpainting has the potential to improve automated brain MRI analysis by reconstructing healthy tissue within pathological regions. We introduce RARF, a task-agnostic region-aware rectified flow framework for masked data generation. We instantiate the framework for 3D brain MRI inpainting as our submission to the BraTS Inpainting Challenge 2026. RARF restricts the stochastic interpolation process to the inpainting region, while the observed voxels remain fixed and provide patient-specific anatomical context. A three-dimensional neural network receives the partially voided image, with Gaussian noise filling the missing region, together with the inpainting mask and the corresponding timestep. The model is trained using masked flow-matching and reconstruction-consistency objectives, combined with mask-aware preprocessing and data augmentation. During inference, the learned velocity field transports the initial noise toward a plausible reconstruction of the missing tissue, which is then combined with the unchanged observed anatomy. Experiments under the BraTS evaluation protocol show that the proposed approach produces competitive reconstructions while maintaining anatomical consistency. Source code is available at: https://github.com/TomasGuija/rarf.
Tomas Guija-Valiente, Blanca Rodriguez-Gonzalez, Norberto Malpica +1
Sep 3, 2026cs.CV

Tensor-based Brain Surface Modeling and Analysis

We present a unified computational approach to tensor-based morphometry in detecting the brain surface shape differences between two clinical groups based on magnetic resonance images. Our approach is novel in a sense that we combined surface modeling, surface data smoothing and statistical analysis in a coherent unified mathematical framework. The cerebral cortex has the topology of a 2D highly convoluted sheet. Between two different clinical groups, the local surface area and curvature of the cortex may differ. It is highly likely that such surface shape differences are not uniform over the whole cortex. By computing how such surface metrics differ, the regions of the most rapid structural differences can be localized. To increase the signal to noise ratio, diffusion smoothing based on the explicit estimation of Laplace-Beltrami operator has been developed and applied to the surface metrics. As an illustration, we demonstrate how this new tensor-based surface morphometry can be applied in localizing the cortical regions of the gray matter tissue growth and loss in the brain images longitudinally collected in the group of children.
Moo K. Chung, Keith J. Worsley, Steve Robbins +1
Sep 2, 2026eess.IV

Data-Efficient Networks for Multi-Contrast MRI Reconstruction based on a Generalized Content/Style Prior

Multi-contrast MR scans contain redundant structural information that can be leveraged during reconstruction and potentially accelerate acquisition times. This idea has inspired end-to-end guided reconstruction models, leveraging one or more contrasts to guide the reconstruction of a different contrast. However, these models require large paired multi-contrast raw datasets for training, limiting their application in low-data regimes. In this work, we propose a modular framework, namely CoSMo-RecNet, for learning guided reconstruction models in the low-data regime. At its core is a reusable multi-contrast representation based on a content/style model, which can be learned from large-scale, publicly accessible, unpaired multi-contrast image datasets, without available k-space data. Using this frozen model as a multi-contrast prior and using a set of reference contrasts, the reconstruction problem reduces to a much simpler refinement problem that can be solved by a lightweight unrolled network and thus learned from small, task-specific reconstruction datasets. We demonstrate the efficacy of CoSMo-RecNet by evaluating it on the low-field 0.3 T M4Raw dataset, showing stable reconstruction quality on decreasing the raw training data budget. CoSMo-RecNet achieved higher reconstruction quality with 5 training subjects or lower compared to a parameter-count-matched MoDL trained on 100 subjects. On a data-limited and severely out-of-distribution ultra-low-field 47 mT Halbach scanner dataset, CoSMo-RecNet was superior to other viable strategies, including classical reconstruction, transfer learning, and zero-shot reconstruction.
Chinmay Rao, Efe Ilıcak, Matthias J. P. van Osch +5
Sep 1, 2026cs.CV

SliceBridge: context-consistent repair of corrupted slice intervals in T1-weighted MRI

Structural magnetic resonance imaging (MRI) images are sometimes corrupted over a contiguous set of slices, where acquisition, motion, hardware, or reconstruction effects leave a single slice or short interval inconsistent with its neighbors while the rest of the image remains usable. Such localized corruption can bias downstream morphometric analysis, yet discarding or reacquiring an otherwise usable image is costly. We formulate this as an image restoration problem: given the location of the affected interval, reconstruct those slices from the surrounding anatomical and imaging context. We propose SliceBridge, a framework for restoring corrupted slice intervals in T1-weighted MRI using rectified flow matching conditioned on the surrounding intact slices and their relative slice positions. Through-plane consistency is encouraged by coupling the slices within the interval through interval-correlated initial noise, a shared flow time, and synchronized sampling. The restored interval is then inserted back, leaving all other slices unchanged. We trained and validated the model on 9,877 T1-weighted brain MRI volumes from four datasets and evaluated it on 581 external subjects using clean interval withholding and controlled corruptions. Compared with a matched model that reconstructed target slices independently, SliceBridge reduced error in slice-to-slice changes within repaired intervals by 32.9%-41.3% across interval lengths and achieved higher SSIM at every interval length. In controlled-corruption cases, SliceBridge reduced the median error in regional brain volume estimates produced by a downstream segmentation model from 1.95% in corrupted volumes to 1.05%.
Jiheng Li, Michael E. Kim, Trent Schwartz +6
Sep 1, 2026cs.CV

Conditional Flow Matching for Cross-Field MRI Harmonisation

Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data across sites. We address cross-field brain-MRI translation for the MRIxFields2026 challenge, and in particular its Task~3: a single model that translates between any directed pair of the five field strengths and across three contrasts. We phrase the problem as a conditional flow matching path: because the source and target volumes are spatially registered, we learn a velocity field that carries the source slice directly to the target slice, rather than starting from noise. To learn this mapping from only three paired subjects, the unified model is trained in three stages: a degradation-bridge pretraining that distills a restoration prior from the abundant unpaired retrospective cohort, a cross-field finetuning over all directed pairs on the paired cohort, and an adversarial refinement that sharpens the output. At inference, we integrate the learned velocity with a second-order Heun solver in a handful of steps. A restoration prior learned without any paired data already reaches a mean SSIM of 0.837, and each subsequent training stage improves on it. A single 6.3M-parameter model thereby covers all 60 field-pair and contrast combinations, with inference in five solver steps per slice. On the challenge evaluation set the model reaches a mean SSIM of 0.909, averaged over the three contrasts, outperforming regression and diffusion baselines built on the identical network on all three challenge metrics.
Baris Imre, Aram Salehi, Levente Baljer +3
Sep 1, 2026cs.CV

BrainDiff: Longitudinal Report Generation for Multimodal Brain MRI

Neuroradiologists rarely read a brain MRI in isolation, yet automated brain-MRI report generation has been built almost entirely for single studies. Temporal analysis has been explored on chest radiography and chest CT, but to our knowledge, longitudinal reporting for brain MRI, where interval change is often subtle and spatially distributed, remains unaddressed. We present BrainDiff, the first longitudinal vision-language system for brain MRI. BrainDiff outperforms both frontier general-purpose and single-study neuroimaging models on the same patient pairs. Moreover, BrainDiff retains 91% of internal RadGraph-XL entity+relation F1 (rg_er) on an external, cross-hospital cohort. Beyond the system, we contribute three analyses. First, we identify two independent grounding levers: a counterfactual objective with prior-report dropout, which increases measured image reliance by ~47%, and a staged curriculum. Together, these interventions raise image reliance 2.5-fold from the baseline. Second, we provide a factorial over prior-report availability and image identity, isolating a visual contribution of +0.0387 rg_er, which grows when the prior report is withheld. Third, a cheap change-decodability test for candidate backbones shows that interval change is decodable far more weakly than single-study pathology (0.60 vs. 0.77 AUROC). Code is publicly available at https://github.com/jhuldr/BrainDiff.
Krish Patel, Peirong Liu
Aug 31, 2026cs.CV

Whole-Body MRI Classification via Prompt-Based Clinical Conditioning

Combining whole-body magnetic resonance imaging (WB-MRI) with clinical variables has the potential to improve systemic disease diagnosis by leveraging complementary sources of patient information. However, structured clinical variables are often incomplete or missing, limiting the applicability of conventional multimodal fusion methods that assume fixed inputs. In this work, we propose TACTIC (Tabular-Attribute Conditioned Transformer for Image Classification), a prompt-based multimodal framework that integrates WB-MRI and structured clinical data through conditional visual feature learning. By encoding clinical attributes as prompts, TACTIC supports an arbitrary number of tabular inputs and naturally handles missing data without requiring imputation or fixed input structures. We evaluate TACTIC on five WB-MRI classification tasks spanning systemic and oncologic applications, including diabetes, chronic obstructive pulmonary disease (COPD), breast cancer, prostate cancer, and metastasis diagnosis. Across all tasks, TACTIC consistently improves performance over image-only baselines when clinical information is available while maintaining strong predictive capability under incomplete tabular inputs. Our results demonstrate the effectiveness of prompt-based models as a flexible approach for improving WB-MRI analysis using clinical context. The model weights and code are available at https://github.com/lauradaza/TACTIC
Laura Daza, Marta Hasny, Cristina González +1
Aug 30, 2026cs.CV

On the Role of MRI Sequences in Cross-Dataset Generalization for Brain Tumor Segmentation

Brain tumor segmentation in magnetic resonance imaging (MRI) is a critical task for diagnosis and treatment planning. Despite the success of deep learning architectures such as U-Net and its variants, performance degradation across datasets remains a major challenge, particularly under domain shift and limited annotated data. To address this issue, this study systematically evaluates how individual MRI sequences influence model robustness across two well-known datasets. A ResUNet-based framework is employed, where each modality is trained independently to isolate its effect under a controlled cross-dataset evaluation protocol with tumor size stratification, without target-domain training, or with limited domain adaptation. Results show that the T2f/FLAIR sequence achieves the best cross-dataset performance, with Dice scores exceeding 75%. It consistently outperforms other modalities across most tumor size ranges, while multi-sequence training further improves performance. Additionally, even limited target-domain adaptation yields rapid initial gains, reducing the need for extensive annotations and costly retraining. Our source code is publicly available at https://github.com/henrique-zan/brain_tumor_segmentation/.
Henrique Zan Grande, João G. Pitol, Lucas B. Schuck +3
Aug 24, 2026cs.CV

AnaDiffusion: Anatomically CompositionalLatent Diffusion for Controllable 3D Brain MRI Generation

3D brain MRI generation has made significant advances in medical imaging, simulation, and controllable anatomical analysis. However, existing generative models typically synthesize 3D volumes monolithically, often overlooking regional anatomical structures and limiting local controllability. To address these limitations, we introduce AnaDiffusion, an anatomically compositional latent diffusion framework that factorizes the generation process into distinct, anatomically meaningful regions, followed by part-to-whole assembly and global refinement. Our approach first trains part diffusion models to capture local structural priors. We then inject an assembled anatomical composite of the parts into the whole-brain latent representation and continue denoising. This mechanism enables the model to resolve global context while preserving the injected anatomy. As a result, AnaDiffusion produces both explicit part assets and a globally coherent volume, thereby enabling controllable part editing without requiring subject-specific dense segmentation maps at inference time while maintaining consistent part-to-whole brain structure. On the subject-disjoint ADNI test split, AnaDiffusion achieves the lowest FID across the whole brain, left and right hemispheres, cerebellar-brainstem complex, and seam regions. It also achieves the best cerebellar and second-best ventricular and brainstem absolute Cohen's d values among the evaluated methods. In localized editing experiments, paired MS-SSIM demonstrates high target transfer and off-target preservation, supporting controllable part replacement with minimal unintended anatomical alterations.
Huiwen Han, Lulin Liu, Bangya Liu +8
Aug 13, 2026cs.CV

How Good are Foundation Models in Longitudinal MRI Disease Progression Reasoning?

Magnetic Resonance Imaging (MRI) interpretation is fundamental to clinical decision-making, requiring radiologists to integrate multi-view anatomical planes across sequential timepoints while precisely localizing interval changes. However, existing vision-language benchmarks remain confined to single-timepoint, single-view interpretation, failing to capture the temporal-spatial reasoning essential to radiologic practice. We introduce the Time-Aware Multi-View MRI Benchmark, an evaluation framework unifying multi-view anatomical input, temporal reasoning across longitudinal scans, and structured localization guidance. The benchmark comprises 3,920 expert-verified question-answer pairs derived from 890 patients across over 3,200 longitudinal MRI timepoints, drawn from seven clinical cohorts covering glioblastoma, neurodegeneration, vestibular schwannoma, and brain metastases, in open-ended, multiple-choice, and binary formats, requiring models to identify anatomical regions of maximal change, characterize progression across sequences and views, and provide structured guidance specifying boundaries, imaging features, and confounders. Experiments across 16 vision-language models reveal moderate temporal alignment but systematic failure on change direction recognition and volumetric quantification, while multi-view inputs improve spatial localization yet degrade temporal reasoning in compact architectures. Our benchmark provides a systematic framework for evaluating progression tracking, interval change localization, and temporal ordering, which are essential for clinical deployment. Code, evaluation splits, and the dataset are available at: https://github.com/wafaAlghallabi/Time-Aware-MRI.
Wafa Al Ghallabi, Ritesh Thawkar, Sara Ghaboura +6
Aug 13, 2026cs.CV

Mr3D-VL: A generalist vision language foundation model for Multiparametric 3D Magnetic Resonance Imaging

Multi-parametric magnetic resonance imaging (mpMRI) is a cornerstone for brain tumor diagnosis and treatment, yet current AI models face critical limitations: their lack of natural language interaction and interpretability impedes spatial information integration and cross-modal reasoning required clinically. Key challenges arise from significant physical meaning differences across modalities, spatial misalignment due to scan intervals, and the need for complex multi-feature interpretation in tasks like glioma grading. While visual-language models (VLMs) show promise in cross-modal understanding, existing methods focus mainly on 2D image modeling, neglecting direct perception of 3D volumetric space. Although 3D VLMs have been proposed for report generation and feature alignment in 3D CT imaging, mpMRI applications demand collaborative inference across multiple imaging modalities-a requirement unmet by current solutions. To address this, we introduce Mr3D-VL, a dedicated visual-language foundation model for multi-parametric 3D MRI. With 4 billion parameters, it employs an unsupervised pre-trained shared 3D encoder and 4D rotational positional embedding for dual modality-spatial integration. Its cross-modal projection layer uses a multi-resolution feature implantation strategy to enhance feature perception across resolutions. Experimental results show significant improvements over existing 4B/7B/30B domain-specific and general-purpose models in text generation tasks, achieving a BERTScore of 0.856 for report generation, with question-answering accuracy at 0.713 and multiple-choice accuracy at 0.912.
Zhi Qiao, Xintong Wu, Yichu He +1
Aug 12, 2026cs.CV

GenFAR: A generalized representation of brain structure, derived from 49,246 multi-cohort MRIs via deep learning

Deep learning models for neuroimaging have largely been developed for individual tasks, limiting knowledge transfer across applications. Here we introduce GenFAR, a modular deep learning framework that learns general, clinically informed features from brain MRIs. We trained this modular architecture on 49,246 individuals across 11 cohorts, using 17 diverse classification and regression tasks spanning cognition, clinical, diagnosis, demographics, and biomarkers. This yields aggregated, focused feature sets that capture rich, clinically- and biologically-relevant brain representations. We developed a sequential learning approach where tasks progressively build on previously learned representations. Through an analysis of 5,000 task sequences, we identified an optimal sequence length of six tasks and introduced a Donor Score metric to quantify each task's contribution to downstream performance. This analysis revealed five consistently strong donor tasks (Age, AD/MCI, MMSE, Hypertension, Hyperlipidemia) that formed the base of our sequential model. We demonstrated the utility of our learned representation, in various tasks beyond those included in the training set, to serve as the foundation for specialized secondary predictors. We further showed that using the learned feature representation can substantially increase the sample efficiency of secondary deep learning training tasks and models, as well as improve their accuracy.
Vishnu M. Bashyam, Guray Erus, Junhao Wen +29
Aug 12, 2026cs.CV

Evaluating and Calibrating Diffusion Model-derived Uncertainty for Quantitative MRI Mapping

Quantitative MRI (qMRI) provides standardised tissue parameter maps, but the reliability of deep learning-based qMRI mapping methods is often not explicitly characterised. In this work we systematically evaluate uncertainty maps for quantitative MRI derived from multiple inferences of a data-consistent diffusion model-based qMRI framework. Evaluation on synthetic test data assessed error-awareness, high-error detection, selective prediction, and Gaussian interval calibration. Diffusion model-derived uncertainty was positively associated with the mapping error, while risk-coverage analysis showed that excluding high-uncertainty voxels reduced the retained error. However, the raw uncertainty was poorly calibrated for quantitative interval interpretation. Calibration was substantially improved using a post-hoc procedure combining prediction-value-dependent bias correction with scalar uncertainty scaling. Qualitative evaluation on a healthy volunteer showed spatially meaningful uncertainty patterns. These results indicate that diffusion model-derived uncertainty is informative for reliability assessment and selective prediction, but requires calibration for quantitative interval interpretation.
Shishuai Wang, Stefan Klein, Juan A. Hernandez-Tamames +1
Aug 12, 2026eess.IV

A comparison of CNN architectures for Alzheimer's disease detection in single-view MRI scans

Alzheimer's disease is a leading cause of death with no cure. Therefore, early detection is critical to slow progression and preserve quality of life. Diagnosis relies on medical history, cognitive tests, physical exams, and MRI brain scans, making deep learning suitable for Alzheimer's classification. This work proposes a benchmark that evaluates ten different convolutional neural network (CNN) architectures (including ResNet, DenseNet, MobileNet, EfficientNet, and VGG family models) under the same held-out test split protocol. A two-stage transfer learning and full fine-tuning pipeline is introduced to perform training using a class-balanced subset (3,900 images) derived from the OASIS medical imaging dataset, comprising 86,437 single-view MRI brain scans labeled into four classifications of Alzheimer's disease: Non-Demented, Very Mild Dementia, Mild Dementia, and Moderate Dementia. The best results were achieved by VGG16, with a 0.9637 validation accuracy and a 0.9533 test accuracy score. A key finding documented in this work is the difficulty of classifying the transition from Non-Demented to Very Mild Demented stages, observed consistently across all ten architectures.
Hiram Zuniga, Ulises Orozco-Rosas, Kenia Picos
Aug 11, 2026cs.CV

Gaussian Meta-Space Augmentation for Stacking Ensembles in Multimodal IPMN Risk Stratification

Pancreatic cancer is among the most lethal malignancies; risk stratification of intraductal papillary mucinous neoplasms (IPMNs) offers a crucial opportunity for early intervention but typically requires invasive tissue biopsy. Dominant vision-based approaches, including radiomics and deep learning, provide promising but initially separate discrimination opportunities. Similarly, multisequence MRI (T1W/T2W) and anatomically decomposed (head, body and tail) analysis of the pancreas provide additional and potentially complementary signals. Effective fusion of this information is crucial in ordinal IPMN dysplasia risk prediction and can be accomplished via a meticulously regularized and calibrated ensemble stacking combiner. We present cUPMI, a class-conditional Gaussian augmentation of a combiner's log-probability meta-features, and test it on various prediction paradigms. In our multi-center analysis, we find cUPMI adds limited value to properly regularized L2-logistic binary classification stacks, but consistently regularizes higher-capacity tree combiners in the binary and radiomics-only setting (RF +0.015 and XGBoost +0.024 binary AUC, positive in all seeds). Its cleanest ordinal benefit appears for XGBoost on an 8-stream radiomics task (3-class no < low < high, +0.022 QWK in all seeds). Separately, fold-locked fusion of radiomics and 2.5D CNN streams yields the strongest overall model, an RF stack reaching QWK 0.595 (95% CI [0.54, 0.64]) and binary AUC 0.839, surpassing radiomics, 2.5D ResNet, and 3D DenseNet-121 baselines.
Max A. Nelson, Eminenur Sen Tasci, Zhixiang Wang +12
Aug 11, 2026cs.CV

Modelling Geographic Atrophy Progression using Implicit Neural Representations

Age-related Macular Degeneration (AMD) is the major cause of blindness in the Western world. Its late dry phase is characterised by irreversible atrophic areas, namely Geographic Atrophy (GA). Longitudinal Fundus Autofluorescence (FAF) image acquisitions are currently the main tool for assessing lesion growth over time at the image level. However, due to its highly individualised progression, the evolution of late AMD remains poorly understood. In this work, we propose using Implicit Neural Representations (INRs) to model GA progression at the individual level in a low-data setting. Our approach generates both FAF and GA segmentation at both past and future time points. Among the comparison models, our method achieves competitive segmentation quality across different scenarios, yielding the lowest Mean Absolute Error (MAE) for the GA lesion area and the highest DICE score, without sacrificing FAF image quality. The code is available at https://github.com/SimoneSarrocco/ga-progression-with-inrs.
Simone Sarrocco, Paul Friedrich, Florentin Bieder +4
Aug 10, 2026cs.CV

Frozen Brain-MRI Foundation Models Are Site Fingerprints

Frozen foundation-model (FM) embeddings are increasingly used as off-the-shelf brain-MRI representations, on the assumption that they capture anatomy. We audit what they actually encode and find that acquisition site is a large, intrinsic component of the representation. Across two independent cohorts (ABIDE-I, ABIDE-II), three frozen 3-D encoders (brain-pretrained, CT-pretrained, and randomly initialized), and every network depth, site is linearly decodable at roughly 0.9 balanced accuracy at deep layers, exceeding the decodability of every clinical or demographic variable (sex, age, autism diagnosis) at every layer. The effect is intrinsic rather than learned: a randomly initialized encoder is already a ~0.9 site classifier on both cohorts and across three architecture families (Swin, ViT, ResNet), and site is decodable at ~0.95 directly from the raw downsampled image with no encoder, so the fingerprint reflects low-level image statistics that any encoder preserves rather than a product of pretraining. Residualizing measured population covariates leaves site decodability essentially unchanged, indicating an acquisition- rather than population-driven effect. A nonlinear probe matches the linear one, so the fingerprint is fully linearly accessible. The site subspace is removable post hoc by iterative null-space projection or ComBat (site decodability 0.94 -> 0.07/0.00), and is a site-attribution concern for shared or federated embeddings; but for dense segmentation this removal is not free, because site and anatomy occupy an entangled linear subspace (a matched-rank random-direction projection is Dice-neutral, whereas removing the site subspace is destructive). We recommend site-audited use of frozen brain-MRI FMs and release an open audit toolkit.
Saman Rahbar
Aug 10, 2026cs.CV

MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models

Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (ΔΔPSNR <1<1,dB, ΔΔSSIM <0.02<0.02; paired TOST p=[[p]]p=[[p]]): mean PSNR is 27.3,dB vs. 27.0,dB and mean SSIM is 0.95 vs. 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The codebase is available at https://github.com/lisafis/MRIComp4Flow .
Lisa K. Fischer, Mykhailo Riabets, Daniel Rueckert +3
Aug 10, 2026cs.CV

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.
Mojtaba Safari, Shansong Wang, Zach Eidex +4
Aug 10, 2026cs.CV

MPISuperRes-PnP: A Super-Resolution Zero-Shot Plug-and-Play Reconstruction Algorithm for Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is an emerging medical imaging modality. MPI is based on the non-linear response of magnetic nanoparticles to an applied magnetic field and avoids ionizing radiation. The measured signal is the voltage induced in receive coils by the particles' response. Reconstructing the particle concentration from the signal constitutes the imaging task. Even using state-of-the-art measurement-based reconstruction, the associated spatial grid is very coarse, hence super-resolution (SR) techniques are important. In this work, we propose an approach for SR in MPI inspired by energy minimization. Different methods have been proposed for SR in MPI, ranging from upscaling of the associated system matrix to interpolation of the reconstruction. Here we incorporate SR into the reconstruction task via an energy minimization formulation. Following the plug-and-play approach to energy minimization we derive a splitting scheme and a SR method for MPI where the arising Gaussian denoising task is treated with a pre-trained learned Gaussian denoiser in a zero-shot fashion. This way, we incorporate benefits of deep learning without training and avoid the need of training data. Further, we provide a quantitative and qualitative evaluation of the proposed method. Hyper-parameter are selected via an extended parameter search. The found parameters are applied for reconstruction on real data. We show the applicability of our method on synthetic and on real data (MPIData: EquilibriumModelWithAnisotropy and 2D-OpenMPI Data). The proposed method employs a deep-learning denoiser without training -- thus it does not require presently scarcely available MPI training data. The denoiser behaves conservatively, i.e., no hallucination artifacts were observed. The SR approach is generic such that it can be applied in future MPI contexts involving different regularizers or different imaging tasks.
Vladyslav Gapyak, Thomas März, Andreas Weinmann
Aug 10, 2026cs.CV

Task-Adaptive 3D Cross-Field MRI Translation via Field-Conditioned Content-Style Pretraining

Magnetic field strength is a major source of domain shift in magnetic resonance imaging (MRI), affecting signal-to-noise ratio, tissue contrast, spatial detail, and the visibility of anatomical boundaries. The MRIxFields 2026 challenge investigates this problem through cross-field MRI translation across acquisitions at 0.1T, 1.5T, 3T, 5T, and 7T. Its three tasks, Any-to-7T, 0.1T-to-High, and Any-to-Any synthesis, require the generation of target-field image characteristics while preserving subject-specific anatomy. This problem is particularly challenging because paired acquisitions of the same subject across multiple field strengths are rarely available for training. We propose a 3D unpaired cross-field MRI translation framework based on field-conditioned content-style pretraining. The proposed framework first learns controllable field-to-field translation across all available field strengths by disentangling anatomical content from field-dependent contrast characteristics. The pretrained backbone is then adapted to task-specific target domains. Our model comprises a 3D content encoder, a 3D style encoder, a field-conditioned style generator, an AdaIN-modulated decoder, and a multi-field discriminator. Adversarial learning encourages realistic target-field appearance, while cycle-consistency, identity, content, style, and diversity constraints promote anatomical fidelity and controllable translation. We evaluate the proposed method on MRIxFields data spanning five field strengths and three MRI modalities. Experiments on paired test data demonstrate that the framework can adapt to the three challenge settings while preserving three-dimensional anatomical structure in the synthesized volumes. The implementation code is publicly available at https://github.com/Idea89560041/3D-MRI-Field-Translation.
Haowen Pang, Yingqi Hao, Pengli Zhu
Aug 9, 2026cs.AI

Decoding Phenotypes: A Framework for Fusing Genomic Language Models and Neuroimaging

Neuroimaging and genetic testing are two important clinical references for nervous system diseases, offering complementary diagnostic information. However, integrating genomic and neuroimaging data for precise disease diagnosis is challenging due to cross-modality heterogeneity. Existing imaging-genetics approaches mainly encode genetic information as hard-coded labels, which lose the local sequence context around disease-associated variants. To address this limitation, we propose GeneFuse, a multimodal learning framework that aligns genetic representations from pre-trained Genomic Language Models (GLMs) with features extracted from images. GeneFuse integrates two components: (1) Genotype-Conditioned Feature Modulation (GCFM), a FiLM-inspired module that uses genomic embeddings to modulate image feature maps; and (2) Uncertainty-aware Genomic Residual Fusion (U-GRF), a fusion strategy that uses imaging-derived predictive uncertainty to gate the contribution of genotypic features. We evaluate GeneFuse on early cognitive decline identification (NC vs. MCI) and dementia screening (NC vs. AD). In the APOE-centered setting, GeneFuse achieves AUROCs of 0.77 and 0.83, outperforming existing imaging-genetics fusion methods. These results indicate that GLM-derived genomic embeddings provide additional information to imaging.
Tianli Tao, Ziyang Wang, Emma Robinson +2
Aug 9, 2026cs.CV

MRI super-resolution in ten sampling steps using a diffusion bridge model

Objective. MRI provides excellent soft-tissue contrast, but long acquisition times can cause patient discomfort and lead to motion artifacts, forcing a trade-off between spatial resolution and scan time. Diffusion-based super-resolution (SR) reconstructs high-resolution (HR) images from low-resolution (LR) inputs, but typically needs many sampling steps and initializes from a Gaussian prior ill-suited to image restoration. We developed an efficient diffusion framework that reconstructs HR MRI directly from LR data. Approach. We propose super-resolution diffusion bridge model (SR-DBM), a super-resolution diffusion bridge model that casts SR as a stochastic transport between the LR and HR image distributions. Through a Doob's h-transform of a mean-reverting stochastic differential equation, SR-DBM pins the process to the paired HR and LR images at its endpoints, initializing reconstruction from the measured anatomy rather than from Gaussian noise. The HR image is recovered by a deterministic reverse trajectory in which a network predicts the clean image at each of only ten sampling steps. We evaluated SR-DBM on ultra-high-field 7T brain T1 MP2RAGE maps and pelvic T2-weighted prostate images against nine comparison methods using PSNR, SSIM, GMSD, and LPIPS. Main results. SR-DBM attained the highest PSNR and SSIM and the lowest GMSD on both datasets (brain: 27.66+-1.52 dB, 0.96+-0.02, 7.96+-1.86$; prostate: 27.87+-2.29 dB, 0.80+-0.05, 8.38+- 1.44), with statistically significant gains over every comparison method (two-sided Wilcoxon signed-rank test with Holm correction, p<0.05). The strongest baseline, SR-EMamba, ranked second. Qualitatively, SR-DBM produced the smallest residual errors and best preserved fine structures and lesions.
Mojtaba Safari, Hang Yu, Zach Eidex +10
Aug 9, 2026cs.CV

Parcel2Progression: An Anatomy-aware Longitudinal Framework for Alzheimer's Disease Diagnosis

Alzheimer's disease (AD) progression is a longitudinal process with subtle pathological cues in the early stages. Yet, computational constraints have limited most neuroimaging models to either compromise spatial information or limit the number of longitudinal scans. We aim to overcome this bottleneck and fully leverage high-resolution, variable-length T1w structural MRI (4D sMRI) scan sequences. We introduce Parcel2Progression (P2P), a Longitudinal Transformer Framework which tackles this challenge using an Atlas-guided Parcel Encoder that tokenizes 3D scans into a set of richer anatomically grounded representations. A Longitudinal Transformer then integrates irregular, arbitrary-length longitudinal visits with patient age. This synergy delivers two key advantages: (1) parcel-specific interpretability, and (2) computational tractability for long-term analysis, which scales linearly with the number of scans compared to a naive quadratic 4D ViT cost. P2P outperforms prior works and baselines in both MCI (Mild Cognitive Impairment) to AD conversion prediction and AD vs. CN (Cognitively Normal) classification tasks across ADNI, AIBL, and MIRIAD datasets. Leveraging longitudinal scans boosts performance over single-scan baselines by up to 5% and 7% in balanced accuracy for AD classification and MCI conversion prediction tasks, respectively. Interpretability analysis using parcel saliencies and attention rollouts reveals clinically consistent atrophy patterns in AD and MCI subjects. We also demonstrate the frameworks' reliability in anomaly detection using a synthetic dataset, and test the model's generalizability for other neurodegenerative diseases like Frontotemporal Dementia.
Madhumitha Venkatesh, Shanawaj S Madarkar, Konda Reddy Mopuri
Aug 9, 2026cs.CV

CUPA-T2*: Covariance-Aware Uncertainty Propagation and Alignment for T2* Mapping in Accelerated MRI

Quantitative T2* maps have strong potential for biomarker discovery but are limited by long scan times, rendering them impractical in clinical settings. Significant acceleration can be achieved through undersampling in k-space combined with learning-based reconstruction. However, reconstruction artifacts and noise can propagate into downstream T2* fitting, degrading its accuracy. We introduce CUPA-T2*, a framework that explicitly propagates voxel-wise inter-echo uncertainty from stochastic Monte Carlo dropout reconstructions to downstream T2* fitting via covariance-aware sampling. T2* fitting is performed with a heteroscedastic MLP and a correlation-based regularizer that encourages alignment between predicted variance and reconstruction uncertainty. Experiments on accelerated brain MRI data show tissue-dependent behavior: CUPA-T2* achieves competitive overall T2* fitting performance and improves white-matter performance at higher accelerations. Compared with a heteroscedastic baseline, the proposed framework substantially increases alignment between reconstruction uncertainty and predicted T2* variance, while also revealing a trade-off with calibration (ECE) and selective prediction performance (AURC). CUPA-T2* enables reconstruction uncertainty-aware T2* fitting and delivers voxel-wise uncertainty maps to support the interpretation of quantitative T2* estimates.
Gideon N. L. Rouwendaal, Natascha Niessen, Hannah Eichhorn +3
Aug 9, 2026cs.CV

Anatomically Consistent Cross-Contrast Super-Resolution of Anisotropic Brain T2w MRI

T2-weighted (T2w) brain MRI provides fluid-sensitive soft-tissue contrast that is important for neuro-oncology and radiotherapy planning. However, T2w scans are acquired with anisotropic voxels and appear blurred or stair-stepped on coronal and sagittal views, which obscures small structures and weakens any downstream 3D analysis. We propose VIPP-SR (View-Independent Patched Projection Super-Resolution), a cross-contrast guided super-resolution framework that restores the inter-plane resolution of an existing anisotropic T2w volume without an isotropic ground-truth T2w. VIPP-SR first trains a view-independent patched generator (VIP-GAN) to learn local T1c-to-T2w anatomical correspondence from high-resolution axial slices. The trained generator is then applied to axial, coronal, and sagittal views of the T1c volume to generate three orthogonal T2w estimates. Shape-preserving patching and deepest-skip removal reduce view-specific shortcuts, thereby constraining the generator to learn patch-local representations and enabling the zero-shot inter-plane transfer. Central to VIPP-SR, a projection-based optimization then enforces anatomical consistency across the three view-specific volumes, fusing them by balancing inter-plane self-consistency against per-view data fidelity. The generator is trained on BraTS-MET and evaluated on both the held-out BraTS-MET testing set and the BraTS-GLI cohort without retraining, assessing the cross-cohort generalizability. The results validate that VIPP-SR improves downstream segmentation over the real anisotropic T2w baseline, raising mean-label Dice from 0.330 to 0.465 on BraTS-MET and, zero-shot, from 0.473 to 0.563 on BraTS-GLI and ablation studies identify inter-plane self-consistency as the main source of the gain.
Mengqi Shen, Haicheng Wang, Meghna Trivedi +4
Aug 8, 2026cs.CV

A continually expandable foundation model for brain MRI

Brain magnetic resonance imaging (MRI) is central to neuroscience and clinical assessment, but models are commonly developed for individual diseases, populations or imaging protocols. Foundation models promise more general representations, yet they are usually pretrained once and can lose earlier capabilities when updated with new data. Here we show that Alcmaeon, a three-dimensional brain MRI foundation model pretrained without manual labels on more than 425,000 volumes and derived imaging maps, can be expanded sequentially across clinical domains. Alcmaeon combines volumetric encoding and latent diffusion generation with Graph-Blueprint Pruning (GBP), which protects network modules important to earlier domains while leaving the remaining capacity trainable. Across expansion from healthy ageing and neurodegeneration to developmental, psychiatric and tumour imaging, GBP showed less forgetting than sequential adaptation and elastic weight consolidation across voxel-level reconstruction measures, with its largest advantage after adaptation to tumour imaging. The blueprints provided an inspectable record of how model capacity was protected and reused. Representations from different model levels supported image synthesis, disease classification, survival modelling and postoperative prediction, although no single representation was optimal for every task. These findings provide a route towards brain MRI foundation models that can grow with emerging data while retaining earlier capabilities.
Michail Mamalakis, Carmen Jimenez-Mesa, Yonghao Li +8
Aug 8, 2026eess.IV

DisMorph\texttt{DisMorph}: learning to disentangle technical distortions from true biological change

Longitudinal MRI enables sensitive measurement of structural brain change for studying aging and neurodegenerative disease. Deformable image registration is a key tool for estimating such change by computing a dense deformation that captures geometric differences between longitudinal scans. However, MRI scanners introduce geometric distortions that vary across acquisition systems and protocols, such as gradient non-linearity (GNL) distortion. Existing registration methods estimate a single field that conflates biological and technical effects, potentially biasing downstream morphometric measurements if distortions remain (partially) uncorrected. We propose DisMorph\texttt{DisMorph}, a registration framework trained entirely on synthetic data that explicitly decomposes longitudinal deformation into technical and anatomical transforms. It predicts two dense deformations, each encoding one effect. During training, a novel generative model synthesizes both effects separately to provide disentanglement supervision, while domain randomization promotes generalization across imaging protocols. We evaluate our method in three complementary settings. On simulated data with known ground truth, our method detects anatomical change more accurately and consistently than conventional registration. On real image pairs that differ only by GNL distortion, our method assigns most geometric change to the distortion field, demonstrating specificity in the absence of anatomical change. On longitudinal Alzheimer's disease (AD) pairs, our method detects anatomical change in AD-related brain structures while identifying residual distortion left after standard correction. By disentangling MRI-induced distortion from biological change in the longitudinal deformation, our method paves the way for more accurate longitudinal morphometry in clinical settings where maintaining acquisition consistency is challenging.
Jingru Fu, Kathleen E. Larson, Douglas N. Greve +2
Aug 7, 2026cs.CV

Foundation Models Adaptation for Multi-View Multi-modal Cardiac MRI Segmentation and Direct Ejection Fraction Estimation

Foundation models have shown strong transferability in cardiac MRI (CMR), but their effectiveness for heterogeneous multi-view and multi-sequence CMR analysis remains unclear. In this work, we explore the effectiveness of fine-tuning and combining different CMR foundation models for the Universal Multi-Sequence, Multi-Center and Multi-View CMR Segmentation (CMR-Multi) Challenge. CineMA was fine-tuned for cine and late gadolinium enhancement (LGE) segmentation across short-axis and long-axis views. For direct left-ventricular ejection fraction (LVEF) estimation, we used two recent frozen CMR foundation models to extract embedding vectors that were then combined using attention-based multiple-instance learning for LVEF regression. In the challenge validation set, cine segmentation achieved Dice scores of 0.862, 0.883, and 0.902 for short-axis, two-chamber and four-chamber cine MRI, respectively. LGE segmentation achieved Dice scores between 0.621 and 0.846 across views. The direct LVEF regression model achieved an MAE of 4.96 percentage points and a Pearson correlation of 0.91. These results indicate that foundation models can be effectively adapted and combined for multi-view CMR analysis, while accurate LGE scar segmentation remains a challenging task.
Sina Amirrajab, Cian M Scannell, Volker Vehof +2
Aug 7, 2026cs.LG

A foundation-model approach to pediatric headache classification from rs-fMRI

Headache is the most common neurological disorder in children and substantially affects quality of life. We investigated whether resting-state functional MRI (rs-fMRI) can support pediatric headache classification using machine learning. We encoded rs-fMRI data using NeuroSTORM, a recent foundation model, and fine-tuned it to distinguish healthy controls from children with headache and subsequently classify headache subtypes. We compared NeuroSTORM with a standard neuroscience approach using functional-connectivity (FC) matrices derived from brain activity as predictors. Using 189 rs-fMRI scans from 110 individuals collected across two visits (prevalence of any headache: 74%), NeuroSTORM achieved an area under the receiver operating characteristic curve (AUROC) of 0.82 (95% CI, 0.82-0.82) and an area under the precision-recall curve (AUPRC) of 0.93 (95% CI, 0.93-0.94) for discriminating headache from non-headache. In contrast, models trained on FC matrices showed lower performance (AUROC, 0.67 [95% CI, 0.67-0.67]; AUPRC, 0.85 [95% CI, 0.85-0.85]). In multiclass classification of healthy controls, chronic migraine, and non-chronic headaches (e.g., post-viral headache, new daily persistent headache, post-traumatic headache), NeuroSTORM achieved a macro-AUROC of 0.69 (95% CI, 0.68-0.69). Results suggest that the approach can distinguish chronic migraine but has difficulty differentiating other headache subtypes from chronic migraine. Overall, under limited-data conditions, NeuroSTORM appears to capture latent rs-fMRI representations that transfer to headache-related tasks without relying on FC features. These findings provide proof of concept for fMRI-based prediction of pediatric headache and highlight potential future utility for subtype identification and individualized treatment strategies.
Guilherme S. Imai Aldeia, Clara Moon, Julie Shulman +5
Aug 7, 2026eess.IV

Pre- to Post-Contrast Synthesis of Breast DCE-MRI using Latent Bridge Matching

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is central to breast cancer imaging, but gadolinium administration increases scan burden and motivates contrast-reduced alternatives, including synthetic contrast generation. We propose a latent bridge matching (LBM) framework for synthesizing peak-enhanced breast DCE-MRI from pre-contrast images in the MAMA-SYNTH challenge setting. Instead of starting from Gaussian noise as in conventional latent diffusion models (LDMs), the proposed model learns a conditional bridge between paired pre-contrast and peak-enhanced VAE latents. A latent UNet predicts the remaining correction from intermediate bridge states to the peak-enhanced latent, enabling iterative refinement while keeping the trajectory anchored to patient-specific anatomy. We evaluated two LBM conditioning variants on 91 DUKE validation cases. For the tumor-conditioned variant, tumor masks were used as conditioning inputs. Tumor-conditioning improved performance compared with pre-contrast conditioning, reducing MSE from 1.023 to 0.940 and FRD from 7.523 to 4.716, while increasing tumor SSIM from 0.355 to 0.429. The tumor-conditioned LBM also outperformed the evaluated LDM baseline on this validation cohort. These results suggest that latent bridge matching is a promising pre-contrast-anchored formulation for virtual contrast enhancement, while further work is needed to validate generalization and remove dependence on ground-truth tumor masks at inference.
Sina Amirrajab, Zohaib Salahuddin, Henry C Woodruff +1
Aug 7, 2026cs.CV

International Transfer of Stochastic Cortical Self-Reconstruction

Stochastic cortical self-reconstruction (SCSR) enables personalized mapping of gray matter atrophy, a hallmark of neurodegenerative disorders such as Alzheimer's disease (AD), onto high-resolution cortical surfaces. Unlike conventional normative modeling approaches, which typically operate at a coarse regional level and remain inherently constrained by the covariates included during training, SCSR estimates an individualized healthy reference directly from the observed cortical thickness at the vertex level. This allows the detection of subtle, subject-specific deviations from healthy cortical shape. In this work, we investigate the generalization and transferability of SCSR, originally trained on UK Biobank (UKB) data, to an independent Chinese population dataset. Specifically, we evaluate the ability of SCSR-derived Z-scores to discriminate between healthy scans, individuals with mild cognitive impairment (MCI), and patients with AD, while also assessing model robustness across the lifespan. We compare four training strategies: direct application of the UKB-trained model, fine-tuning on Chinese data, training from scratch, and joint training on UKB and Chinese cohorts. As reconstruction backbones, we consider both a multilayer perceptron (MLP) and a Spherical UNet (SUNet). Our results demonstrate that SCSR provides robust detection of cortical atrophy in the Chinese population across all evaluated models. The highest discriminative performance was achieved by the fine-tuned SUNet model (average pairwise AUC = 0.848), followed closely by the UKB-trained SUNet. Moreover, reconstruction errors remained low across the lifespan, even when the training population exhibited a substantially narrower age distribution, indicating strong cross-population transferability.
Fabian Bongratz, Zhizheng Zhuo, Chao Zhang +3
Aug 6, 2026cs.CV

Do 3D Medical Foundation Models See Through MRI Artifacts? A Controlled Study of Representation Robustness

Self-supervised 3D medical foundation models are increasingly used as general-purpose feature extractors, yet their sensitivity to MRI artifacts remains poorly understood. We present a controlled evaluation of representation robustness across five pretrained 3D encoders spanning different architectures, objectives, pretraining domains, and dataset scales. Using BraTS-Africa cases with four MRI sequences, we generate seven frequency- and image-domain artifacts at five predefined corruption settings. Robustness is assessed using linear centered kernel alignment (CKA), RankMe, and UMAP, complemented by an independent segmentation-consistency analysis. We find that robustness is strongly model- and artifact-dependent. 3DINO exhibits the most consistently stable representations, while BrainIAC is highly sensitive to several corruptions; NeuroVFM, BrainFM, and Neuro-SimCLR show intermediate but distinct artifact-specific profiles. Across many conditions, CKA decreases substantially while RankMe remains comparatively stable, indicating that artifacts often distort representation geometry without causing dimensional collapse. Segmentation consistency also degrades under corruption, particularly for ghosting and Rician noise, but aligns only partially with representation-level robustness. These findings show that larger-scale or domain-specific pretraining alone does not guarantee artifact invariance and motivate explicit robustness evaluation before deploying 3D foundation models in heterogeneous MRI settings.
Julia Anna Mielcarz, Daniel Klaaby, Mostafa Mehdipour Ghazi
Aug 6, 2026cs.RO

A Master-Slave Robot Manipulator for Needle-Based Teleoperation in MRI Chamber

We present a MR safe, master-slave robot manipulator for abdominal interventions in the MRI chamber. A human operated 2+1-DoF master controller manipulator transmits motion and force to a 2+1-DoF slave manipulator via fluid transmission. Jointly, a digital master controller provides multimodal control capability beyond common split axis or mode switchable hybrid human-digital controller configurations found in previous studies. High input impedance, low-leakage, elastomeric fluid actuators are delegated to remote angulation control. Low-friction graphite piston cylinders are delegated to needle insertion axis remote actuation given the sub-newton force transparency and sub-millimeter motion transmission over bedside fluid piping lengths. The device enables real-time MRI guided interventions allowing manual, digital, hybrid, and collaborative control modes. Collaborative tasks such as assisted tissue penetration, fault-driven virtual fixture, and motion compensation through feedback control are presented in this paper. Preliminary MR scanner results demonstrate manipulator functional viability for an in-vivo pig experiment in bedside, manual control mode configuration.
Omar Curiel, Jing-Yuan Huang, Po-Chih Chen +6
Aug 6, 2026cs.CV

Curia-MAE: Multi-Modal Multi-Anatomy MAE Pre-Training for 3D Medical Image Segmentation

Radiology foundation models learn transferable representations that can be adapted to new tasks by training only small layers on top of a frozen encoder. Dense prediction tasks such as 3D segmentation are, however, underrepresented in their evaluation, and, with the encoder kept frozen, pre-trained models still fall short of nnU-Net, the state-of-the-art reference trained from scratch. To close this gap we extend convolutional MAE pre-training with a robust reconstruction objective, a feature regularizer, and a local-global similarity objective. Using this method, we propose Curia-MAE, a multi-modal, multi-anatomy MAE model pre-trained on 300,000 CT and MRI images covering a large number of anatomical sites. On eight anatomy- and lesion-focused segmentation benchmarks, Curia-MAE improves frozen-encoder performance over a strong MAE baseline, while remaining competitive under full finetuning and superior on lesion tasks, where labeled data is scarce. These results indicate that a single frozen encoder can be reused across diverse segmentation tasks, reducing the cost of adapting and deploying such models in clinical workflows. Curia-MAE pre-trained model weights are made publicly available at https://huggingface.co/raidium/Curia-MAE.
Théo Danielou, Antoine Saporta, Léo Alberge +1
Aug 5, 2026cs.CV

YOLO-PVC: 2D-to-3D Consolidation of Slice-wise Detections for Volumetric Liver Tumor Localization in MRI

Slice-wise 2D object detectors are increasingly applied to volumetric data due to their computational efficiency and scalability, yet they often yield fragmented and unstable predictions along the depth axis. We propose YOLO-PVC, a lightweight and model-agnostic framework for 2D-to-3D consolidation of slice-wise detections. The method enforces depth continuity, aggregates bounding box coordinates using robust percentile statistics, and further refines axial extent through a lightweight MLP-based calibration module. Unlike naïve stacking or averaging strategies, YOLO-PVC explicitly addresses missing detections and outlier slices along the depth dimension. Experiments on 3D liver MRI volumes across three tumor categories demonstrate consistent improvements over multiple aggregation baselines. The heuristic PVC achieves an overall IoU3D\mathrm{IoU}_{3D} of 0.6650.665, while the calibrated variant further improves performance to 0.7100.710, with high planar overlap (BEV IoU0.78\mathrm{BEV\ IoU} \approx 0.78). These results demonstrate that structured geometric consolidation provides an effective and practical solution for volumetric liver tumor localization in clinical MRI.
Talha Waqas, Mounir Lahlouh, Kawther Taibouni +4
Aug 4, 2026eess.IV

Unsupervised Adversarial Domain Adaptation for Uterine layer Segmentation: From Labeled Cine to Unlabeled Dynamic EPI MRI

Uterine peristalsis is a key physiological phenomenon responsible for various functions across the menstrual cycle, intimately linked to uterine wall microstructure. Alterations in uterine motion and tissue properties are implicated in the etiology of gynecological diseases, yet these processes have been studied in isolation. We introduce a dynamic multi-echo gradient echo EPI framework for simultaneous characterization and correlation of uterine peristaltic activity and time-resolved T2* changes at 0.55T. Inherent susceptibility artifacts, reduced resolution, and burden of manual uterine layer annotation are addressed by an unsupervised adversarial domain adaptation framework, transferring segmentation knowledge from labeled cine MRI to unlabeled dynamic EPI. We implemented Unet-LSTM with multi-scale domain discriminators that exploits temporal layer dynamics. A Dice score of 0.88 and Jaccard index of 0.80 was achieved. Mean T2* values were 108ms, 76ms, and 124ms for the myometrium, junctional zone, and endometrium. A negative correlation between junctional zone area and T2* was observed in 14/39 cases, providing first insights into oxygenation patterns associated with junctional zone contraction and motion, demonstrating feasibility of assessing the interplay between contractility and dynamic T2* changes.
Smiti Tripathy, Milauni Desai, Jordina Aviles Verdera +1
Aug 4, 2026cs.CV

Towards Reliable and Reproducible Fetal Brain Biometry: A Deep Learning Approach Using MRI

Fetal brain biometry is essential for quantitative assessment of brain development, supporting gestational age estimation, developmental monitoring, and detection of abnormalities. In clinical practice, measurements are manually performed, making them time-consuming and prone to variability. While automated approaches have been proposed, reproducible methods remain limited, particularly those providing anatomically interpretable landmark localization. We present a fully automated deep learning-based framework for reliable and reproducible brain biometry from 3D super-resolution-reconstructed fetal brain MRI. The proposed four-step pipeline derives biometric parameters by jointly estimating linear measurements and their corresponding anatomical landmarks. A 3D convolutional neural network is trained to regress landmark coordinates from brain segmentation label maps, followed by measurement-specific geometric optimization to refine landmark positions and compute measurements. The pipeline is evaluated on two publicly available fetal MRI datasets comprising 150 volumes (gestational age range: 20-37 weeks) acquired across different scanners and protocols, assessing five key biometric measurements across varying acquisition settings and providing a comprehensive evaluation of both measurement accuracy and landmark localization using quantitative metrics and visual assessment. Compared with the only available automated pipeline, the proposed method achieves comparable or improved accuracy for most measurements. In conclusion, we introduce a straightforward pipeline for reliable biometry estimations, with efficiency, interpretability and scalability that support integration into clinical workflows.
Francesca Maccarone, Marina Di Stefano, Giorgio Longari +7
Aug 4, 2026eess.IV

Predictive Enhancement Calibration for Latent Breast MRI Virtual Contrast Enhancement

Virtual contrast enhancement (VCE) synthesizes enhanced breast MR images from pre-contrast acquisitions. Modern latent generators offer strong image priors, but their bounded natural-image autoencoders conflict with the non-canonical intensity scale of MRI. We show that the upper bound can alter radiomic fidelity before generation, while scaling source and target independently creates a coordinate inconsistency. We propose Predictive Enhancement Calibration (PEC), which represents each pair in a shared, case-adaptive coordinate during training and predicts its unavailable upper endpoint from the pre-contrast image at inference. We integrate PEC with a pretrained FLUX latent flow transformer via parameter-efficient reference conditioning. Target round trips first isolate representation loss before generation; near-matched conditional models then compare PEC with fixed-wide and separate coordinates under comparable training budgets and backbone settings. On the fixed internal MAMA100 development cohort, PEC improves all eight point estimates in this source-only VCE setting, with paired evidence strongest for MSE and LPIPS.\noindent\textbf{Code:} https://github.com/tanlei0/pec-breast-mri-vce
Qin Lei, Hao Wu
Aug 4, 2026cs.NE

NeuroMosaic: Anatomically Grounded Multimodal Large Language Modeling for Molecularly Aware Glioma Reasoning from 3D MRI and Clinical Narratives

Multimodal medical large language models remain structurally weak for neuro-oncology because volumetric evidence is compressed into generic visual tokens and diagnostic conclusions often lack an auditable link to MRI regions. We present NeuroMosaic, a 3D multimodal language model that converts multi-sequence brain MRI into anatomy-indexed regional tokens, aligns them with clinical narrative and molecular concepts, and generates evidence-linked outputs. The architecture combines a multi-resolution volumetric tokenizer, a neuroanatomical graph router, a molecular concept memory, and selective risk control. Across four glioma cohorts, NeuroMosaic achieved an internal subtype macro-F1 of 0.827 and external macro-F1 values of 0.784, 0.761, and 0.742. On UPenn-GBM, it improved over the strongest matched-input baseline by 3.6 percentage points (95% CI: 1.8 to 5.4, adjusted p = 0.0018), with IDH, 1p/19q, and MGMT AUROCs of 0.918, 0.861, and 0.781. Evidence pointing accuracy reached 0.703, and targeted evidence deletion reduced correct-answer probability by 0.187, compared with 0.046 for random deletion. These results establish anatomy-indexed routing as a measurable mechanism for accurate, grounded, and calibrated volumetric medical-language reasoning.
Yantong Liu, Zheyu Zhang, Runpeng Liu +3
Aug 4, 2026cs.CV

CRIL-U-Net: Compact Ratio-Interaction Learning for Focal Cortical Dysplasia Segmentation from T1w and FLAIR MRI

Focal cortical dysplasia (FCD) type II is an important structural cause of drug-resistant focal epilepsy, but its small size, heterogeneous appearance, and subtle MRI characteristics make automated segmentation challenging. Conventional multimodal networks commonly concatenate T1-weighted (T1w) and fluid-attenuated inversion recovery (FLAIR) images, requiring subsequent layers to learn useful cross-modal relationships implicitly. We propose CRIL-U-Net, a 3D U-Net incorporating a Compact Ratio-Interaction Learning module that combines local spatial features, voxel-wise cross-modal mixing, and bidirectional ratio-inspired interactions. CRIL-U-Net was compared with a conventional 3D U-Net and an input self-attention U-Net using five-fold cross-validation on 85 FCD subjects and 25 healthy controls. Each architecture was trained independently using Dice-binary cross-entropy (Dice-BCE) and Focal Tversky-Focal (FTF) losses. With FTF, CRIL-U-Net achieved the highest mean Dice score (0.196 +/- 0.262), compared with 0.136 +/- 0.224 for the U-Net and 0.135 +/- 0.214 for the attention comparator. It produced nonzero lesion overlap in 44 of 85 cases, compared with 36 for the U-Net. Under FTF, CRIL-U-Net significantly outperformed both comparison architectures after false-discovery-rate correction. These findings suggest that compact cross-modal representation learning can improve FCD segmentation within a controlled U-Net setting when combined with an imbalance-aware objective, although the remaining zero-overlap rate of 48.2% highlights the need for further validation and methodological development.
Soumen Ghosh, Amit Soni Arya, Tilottama Goswami +3