Single-Subject Gait Dataset

Recent momentum

+167%

8 papers in the last 28 days · 0.1% of indexed attention

Twelve weeks of publication activity for this topic as it is defined today.

Weekly history

Recent digests

What was published in this topic, kept on the site without email delivery.

Period ending 2026-09-21

3 new papers

A weekly snapshot of new work published in Single-Subject Gait Dataset.

Period ending 2026-09-14

3 new papers

A weekly snapshot of new work published in Single-Subject Gait Dataset.

30 papers

Latest in Single-Subject Gait Dataset

Sep 14, 2026cs.RO

Assistance Torque Estimation via Dynamics-Aware Optimization for Lower-Limb Exoskeleton in Complex Environments

Ground-truth human joint torque estimation relies on motion capture systems, which suffer from limited outdoor usability and significant deployment expenses. Furthermore, direct scaling of ground-truth joint torques to obtain motor torque commands is not necessarily the optimal strategy. To address the aforementioned limitations, inspired by the human motion generation process, this paper proposes a novel assistance torque estimation method based on the dynamic model. From an optimization perspective, the proposed method directly generates motor-assist torque and lowers the cost of data acquisition. Then, a data-driven assistance torque prediction network is trained to enable accurate real-time prediction under complex outdoor environments. Experimental results demonstrate that optimized (estimated) assistance torque exhibits better phase consistency with gait trajectories and better alignment with task characteristics. Relative to the Zero torque condition, the predicted torque can decrease metabolic rate by 11.8%-17.7%, heart rate by 8.9%-14.3%, and peak muscle activation levels by 28.2%-54.0%, respectively. This provides a new perspective for low-cost adaptive exoskeleton assistance.
Xiao-Yin Liu, Guotao Li, Weiqun Wang +1
Sep 14, 2026cs.LG

3D Digital Twin Visualization of Multiclass GRF-Based Gait Disorder Classification

Automated gait analysis requires accurate classification and interpretable outputs. We propose an integrated framework for classifying healthy gait and multiple musculoskeletal impairment groups using bilateral ground reaction force (GRF) and center-of-pressure (COP) signals. The signals were normalized over the stance phase and standardized using training-set statistics. The model achieved a validation accuracy of 99.00% and a test accuracy of 90.07% under a session-level split. Class-specific ϵ\epsilon-LRP identified positive and negative contributions across both sides, multiple signal components, and different stance phases. Separately, the processed GRF signals and model predictions were synchronized within a Blender-based 3D visualization, enabling sample-level inspection of gait trials and classification results. The proposed framework integrates classification, explainability, and 3D visualization to improve model transparency. The source code is available in the following repository: https://github.com/nyoico/grf-gait-3d-visualization.git
Nayoung Son, Minwoo Shin
Sep 14, 2026cs.RO

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.
Hyungseok Ryu, Pilwon Hur
Sep 13, 2026cs.RO

A Personalized Dynamic Balance Evaluation Paradigm for Hip Exoskeleton-Assisted Walking under Unexpected Ground Perturbations

Hip exoskeletons may improve recovery from unexpected gait perturbations, yet personalizing assistance remains difficult because balance is multidimensional and human-in-the-loop experiments are small-sample and noisy. We present a participant-specific composite balance cost that integrates seven biomechanical sub-metrics spanning margin of stability, center-of-mass dynamics, and whole-body angular momentum. The sub-metrics are converted to direction-aligned, dimensionless cost features, and nonnegative fusion weights are learned on the simplex. Coupled with an empirical-Bayes hierarchical model, the learned-composite selector estimates each tested condition's posterior probability of being best, P(best), and a high-probability candidate set with size K0.8K_{0.8}. The framework was evaluated with three participants walking at 1.1 m/s during unilateral belt-slip perturbations across 46 hip-assistance conditions. In the full-budget analysis (B = 4 repeats per condition), the selector concentrated 80% of the posterior probability within 1 to 5 of 46 conditions, compared with 2 to 12 for equal-weight fusion and 4 to 37 for principal component analysis fusion. This smaller candidate set could shorten personalization experiments and limit participants' exposure to repeated perturbations in future studies. Selected-condition trials showed lower observed composite costs than no-torque trials, with nominal p < 0.05 for P2 and P3. Leave-one-repeat-out refits yielded positive mean held-out rank correlations for all participants and moderate stability of the learned weights and candidate sets. These proof-of-concept results support participant-specific composite balance evaluation for candidate selection in perturbation-based human-in-the-loop experiments.
Yun Chen, Oluwasegun T. Akinniyi, Qiang Zhang
Sep 9, 2026cs.CV

Freezing of Gait Prediction Under Spatial Occlusion: An IMU-Supervised Cross-Modal Distillation Approach

Parkinson's disease is a progressive neurodegenerative disorder characterised by gradual deterioration of movement control. Automated freezing-of-gait (FOG) detection supports the objective assessment of gait-related motor impairment. Two common approaches are used for FOG prediction: (i) analysing video recordings of the patient's movements and (ii) analysing data collected using inertial measurement unit (IMU) wearable sensors attached to the patient's lower limbs. Video-based approaches may suffer detection errors during continuous turning-in-place tasks because the lower limbs undergo substantial geometric self-occlusion, degrading pose-estimation accuracy. IMU-based approaches are generally less affected by visual occlusion; however, they are difficult to deploy outside clinical or laboratory settings, as the sensors must be attached securely and remain in place throughout the assessment. Motivated by this, we propose a cross-modal subspace distillation framework to mitigate the limitations of unimodal FOG detection by combining IMU accuracy with video-based practicality. We extract invariant latent topologies from a pre-trained kinematic oracle to structurally supervise a non-encoded visual architecture during training. To resolve periods of severe spatial occlusion, a dual-stream visual model probabilistically fuses skeletal graph nodes and continuous spatial pixels, dynamically shifting reliance to uninterrupted pixel boundaries as joint tracking confidence drops. Evaluated against a public, multi-modal sequence dataset of Parkinson's individuals executing continuous 360360^\circ turns, empirical results demonstrate that applying sensory boundary topologies strictly mitigates tracking evaluation entropy. Our constrained optimisation confirms that highly precise FOG prediction bounds can be achieved over zero-wearable inference environments.
Chandan Biswas, Aryan Singh, Anabik Pal
Sep 9, 2026cs.CV

Recovering Biomechanical Signals from Missing Keypoints Using Temporal Interpolation in Monocular Gait Analysis

Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-driven model reduction. While prior work on recovering missing joints focuses on complex learned models, the effectiveness of simple temporal methods remains underexplored. We evaluate knee-angle estimation under a missing-ankle-keypoint condition and test a first-order temporal interpolation scheme as a recovery mechanism. Across 527 frames of monocular walking video (428 with valid baseline detections), removing the ankle keypoint increased mean angular error to 23.4° +/- 46.7° and collapsed signal variance to near zero. Temporal interpolation reduced error to 1.1° +/- 6.7° and restored variance and smoothness to within a few percent of baseline. These results indicate that gait signals possess sufficient temporal redundancy for a simple, computationally trivial interpolation scheme to recover a critical missing joint, without resorting to learned reconstruction models. The findings support low-complexity, real-time-compatible designs for gait analysis in resource-constrained or occlusion-prone monocular settings.
Shubham Jariwala
Sep 8, 2026cs.CV

SynthGait-19K: A Physically Grounded Synthetic Video Dataset for Gait Parameter Estimation

Accurate estimation of clinically meaningful gait parameters from monocular video is important for scalable mobility assessment, yet progress is limited by the small scale, restricted viewpoints, and limited visual diversity of existing datasets. We introduce SynthGait-19k, a physically grounded synthetic video dataset containing 19,272 walking videos derived from 6,427 MoCap sequences across 437 subjects, with paired SMPL motion and annotations for six gait parameters. To construct the dataset, we develop Gait2Vid, which unifies heterogeneous MoCap recordings through SMPL and synthesizes diverse RGB walking videos under controllable viewpoints and scene appearances. We assess the generated videos for consistency with their conditioning gait kinematics and validate extracted gait events against force-platform measurements. Using SynthGait-19K, we benchmark direct RGB, pose-based, biomechanical, and human-mesh-recovery approaches and analyze viewpoint, training-data scale, and synthetic-to-real domain shift. We also introduce GaitXFormer as a direct RGB reference model for estimating gait parameters. Synthetic supervision transfers effectively to real videos across both GaitXFormer and a pose-based architecture, demonstrating utility across different representations. We further find that spatial gait parameters are more sensitive to visual domain shift and that improved HMR reconstruction alone does not necessarily translate to improved downstream gait estimation.
Soroush Mehraban, Xin Lei Lin, Vida Adeli +5
Aug 27, 2026cs.CV

Who Remains, What Changes: Identity Anchored Composed Gait Retrieval

Gait recognition has achieved remarkable progress, yet existing methods remain confined to rigid visual matching and often overlook the potential of natural language instructions for interactive retrieval. In this paper, we introduce Composed Gait Retrieval (CoGR), a novel task that retrieves a target gait sequence based on a reference sequence and a natural language modification query. To address the absence of existing datasets for this task, we design an automated annotation pipeline powered by large vision-language models (VLMs) to construct the first gait-language datasets: Language-Augmented CCPG and Language-Augmented CASIA-B. Building on this, we propose ComposeGait, an identity-anchored composition framework designed to prevent the identity drift that arises when generic composed retrieval follows the instruction but returns the wrong person. Its Part-aware Identity Adapter (PIA) aggregates multi-frame, part-aware identity evidence into a sample-specific ID token. We inject the ID tokens into both branches of a shared Q-Former to preserve identity, while excluding the ID-token outputs from the final retrieval embeddings. Joint identity and task-adapted composed-retrieval objectives optimize this space end to end. We evaluate ComposeGait on both benchmarks and show that it achieves the best R@1 among the compared methods, reaching 72.38% on Language-Augmented CCPG and 83.61% on Language-Augmented CASIA-B. These results establish ComposeGait as a strong baseline for CoGR. The datasets and code will be made publicly available.
Jingchen Fei, Zengbin Wang, Yukun Liu +3
Aug 3, 2026cs.LG

Deep Learning-Based Estimation of Ground Reaction Forces in Parkinsonian Gait Using an Optimized Set of IMU Data

Accurate gait analysis in Parkinson's disease (PD) typically relies on laboratory-based systems to capture biomechanical data, such as ground reaction forces (GRFs). Estimating GRFs using inertial measurement units (IMUs) provides a feasible alternative. However, this approach remains challenging in pathological gait like PD due to its high variability and complexity. Moreover, existing monitoring approaches often require multiple body-mounted sensors, which limit practicality and reduce patient compliance. To date, no study has investigated the application of deep learning approaches to address this challenge. This study proposes, for the first time, a deep learning framework to estimate bilateral vertical GRFs (vGRFs) in PD using an optimized set of wearable IMUs. A hybrid CNN-BiLSTM model was trained separately on data from 61 PD patients and 65 healthy controls (HC) using 13 IMUs. The model achieved high intra-subject accuracy (R2R^2 = 0.98) and strong inter-subject generalization (R2R^2 = 0.93 for HC, R2R^2 = 0.91 for PD). Sensor configuration was found to significantly influence estimation accuracy, with optimal sensor placement varying between PD patients and HC. For PD patients, estimation accuracy dropped markedly when reducing to a single IMU. The optimal configuration for PD used four IMUs. We identified a minimal setup with only two IMUs still enabled robust estimation. This compact setup offers a practical and scalable solution. Overall, the proposed approach supports the development of wearable vGRF-based gait analysis systems for Parkinsonian gait and potentially other pathological conditions, enabling accessible clinical assessments, remote monitoring, and personalized rehabilitation.
Run Lin, Yingtian Tang, Jiawen Xu +6
Aug 1, 2026cs.CV

The 1st AI Children Challenge

The First AI Children Challenge aims to advance real-world applications of computer vision and AI in child healthcare, child education, and pediatrics. The 2026 CV4CHL edition featured the first track in this domain: Children Gait Visual Analysis. The main goal of Children Gait Visual Analysis is the fine-grained analysis of children's gait behaviors from keypoint sequences. This is still a big challenge for human action recognition. Experienced medical doctors can distinguish these subtle nuances, but none of the people test AI models in this domain. To bridge this gap, we introduce thousands of 2D children keypoint sequences walking around videos across various age groups of children (3-16 years old). There is a significant opportunity for batch analysis of these videos to provide clinically relevant insights into medical diagnosis. The Challenge will be launched with two problem tracks: Edinburgh Visual Gait Score (EVGS) Scoring and Classification of Gait Patterns in Bilateral Spastic Cerebral Palsy. Each track is chosen in consultation with board-certified pediatricians based on the value of potential solutions. With the first available dataset for such tasks and ground truth for each track, the challenge enabled participants to evaluate their solutions. Final rankings will be revealed after the competition concludes, fostering reproducibility and mitigating overfitting.
Boyi Li, Yifan Shen, Houze Yang +7
Jul 31, 2026cs.CV

MHRGait: Gait Recognition from Momentum Human Rig Pose

Gait recognition is shaped by its input representation. Silhouettes encode projected body shape, skeletons encode sparse joint coordinates, and 3D meshes encode dense surface geometry. In each case, identity-bearing articulation is observed through geometric carriers that also vary with clothing, skeletal scale, or body shape. We investigate whether gait can instead be recognized from compact articulated controls. We introduce Momentum Human Rig (MHR) pose as a gait representation, describing each frame using 184 semantically organized body and hand parameters estimated from monocular video. MHRGait groups these heterogeneous controls by anatomy, models their intra-frame coordination and temporal evolution, and produces compact body and hand descriptors. We further introduce MHRGait++, which combines MHR pose with silhouettes through modality-balanced distance fusion, preventing descriptor count from determining modality importance. Experiments on four benchmarks show that MHRGait attains the best overall performance among compared model-based methods on CCPG and SUSTech1K and transfers effectively across datasets, while its recognition network requires only 2.76M parameters and 0.69 GFLOPs for a 30-frame input. MHRGait++ consistently improves silhouette recognizers with a favorable accuracy-efficiency trade-off. These results establish rig-space articulation as an effective standalone gait representation and a complementary cue to projected body shape. Our code is available at https://github.com/duanhuiran/MHRGait.
Huiran Duan, Qian Zhou, Xianda Guo +4
Jul 24, 2026cs.RO

A Replay-Constrained Simulation Framework for Personalization of Powered Knee--Ankle Prosthesis Controllers

Personalization of impedance controllers for powered prosthetic legs is critical to accommodating individual gait biomechanics but remains challenging. Existing methods rely on time-intensive human-in-the-loop exploration and/or constrain optimization to low-dimensional, single-joint parameter subspaces. Sim-to-real transfer has enabled high-dimensional locomotion control for legged robots, but in assistive device control the human partner remains un-modelable. We present a replay-constrained simulation framework: a MuJoCo-based simulator reproduces prosthetic knee-ankle dynamics while replaying recorded hip kinematics and feedback-based ground reaction forces from individual walking data, bypassing the need to model complex human neuromuscular control mechanisms. We demonstrate the framework with a deep reinforcement learning policy that personalizes phase-dependent stiffness, damping, and equilibrium angle at both joints simultaneously, maximizing a biomimicry-based reward computed solely from onboard prosthesis measurements. Experiments with three participants with transfemoral amputation during level-ground walking at 0.8~m/s demonstrate strong simulation-to-hardware predictive validity (Pearson r=0.96r=0.96--0.9970.997). The best-performing policy on hardware was consistently predicted within the top five simulation policies for all participants. The learned controllers improved overall biomimicry rewards by 42--59% relative to the unpersonalized baseline. The framework supports scalable high-dimensional personalization of powered prosthetic legs and is amenable to extension to higher-dimensional controller parameterizations such as neural-network controllers.
Duong Le, Ryan Posh, Shihao Cheng +2
Jul 16, 2026cs.RO

Assessing Physical Frailty and Fall-Risk Indicators with Social Robots: An in situ Evaluation with Older Adults

Frailty assessments are crucial to evaluate the risk of adverse events and the health and social care needs of older adults, yet their administration remains resource-intensive and typically relies on coarse clinical outcomes, such as task completion times, which may overlook biomechanical indicators of functional decline. To address this, we present a robotic framework that guides older adults through standardised frailty and fall-risk tests while capturing clinical scores and additional frailty-related metrics, offering a deeper insight into a user's condition. The system uses a Behaviour Tree architecture that coordinates perception, decision-making, interaction, and measurement modules. Using vision-based skeleton tracking, the robot evaluates established clinical tests, including the Short Physical Performance Battery (SPPB) and the Timed Up and Go (TUG). The framework was co-designed with healthcare professionals and evaluated in situ during six months in a rehabilitation centre's research lab with N=81 older adults. Robot-derived measurements were compared against therapist assessments and clinical reference instruments, including a gait analysis walkway and an inertial measurement unit (IMU). Results showed excellent agreement for most test completion times and gait-related parameters (ICC>0.9ICC > 0.9). And, substantial agreement for the overall SPPB score comparing the robot and the therapist (k=0.67k = 0.67) and moderate agreement comparing the robot and the IMU (k=0.55k=0.55). The findings highlight that social robots can provide reliable and objective frailty assessments in healthcare settings while enabling the collection of relevant mobility indicators beyond conventional outcomes.
Aniol Civit, Antonio Andriella, Alba Martínez +4
Jul 12, 2026cs.RO

Learning Roller-Skating Motions of Humanoid Robots Based on Adversarial Motion Priors

Humanoid roller-skating is difficult because the robot must coordinate whole-body balance, rolling contacts, and velocity-dependent posture regulation. This paper presents an adversarial motion prior based reinforcement learning framework for two humanoid roller-skating gaits: Pump Glide skating and Push Glide skating. The two gait datasets are collected independently through motion capture and retargeted to the humanoid robot separately. The retargeted data are then smoothed and resampled into reference motion states for AMP training. The two gaits are learned by independent AMP training pipelines with separate reference datasets, separate policies, and independent reward architectures. Simulation experiments are designed to evaluate gait quality, velocity tracking, turning, and gait-specific reward ablations.
Yunkang Cheng, Yutong Wu, Menghan Li +2
Jul 8, 2026cs.RO

Generating Personalized Lower-Limb Kinematics Across Walking Speeds Using Subject-Conditioned Diffusion

Personalizing exoskeleton assistance requires user-specific gait data across many locomotor tasks, yet collecting this data demands repeated motion capture sessions that are costly, time-intensive, and especially burdensome for clinical populations. This challenge is most acute across walking speeds, where gait changes substantially and deviates further in clinical gait. This work introduces a subject-conditioned residual diffusion framework that generates personalized lower-limb kinematics at unseen walking speeds from a subject's gait sequence at a single seen speed. Given sagittal-plane hip, knee, and ankle trajectories at a seen speed and a desired unseen speed, the model generates a residual that transforms the seen trajectory into the unseen one, using a transformer denoiser conditioned on the subject's gait and the two speeds through feature-wise linear modulation. Trained only on able-bodied data, the model achieved a mean absolute error (MAE) of 3.4° on held-out able-bodied subjects. Without any stroke-specific fine-tuning, it achieved a 6.0° MAE on out-of-training-distribution stroke subjects, retaining subject identity for clinical gait. The framework reduced the MAE by over 70% relative to supervised feed-forward baselines, and a single seen speed matched the accuracy of four speeds within 0.4°. These results demonstrate that subject-conditioned residual diffusion can synthesize personalized gait across speeds from minimal data, reducing the collection burden for downstream exoskeleton personalization.
Diya Dinesh, Adrian Krieger, Changseob Song +3
Jul 5, 2026cs.CV

A non-invasive video-based method for individual identification of wildlife using gait dynamics

Gait is a distinctive behavioral characteristic that enables non-invasive individual identification without requiring physical interaction with an animal. While gait-based analysis has been extensively studied in humans, its application to wildlife remains limited due to environmental variability and the lack of scalable identification methods. This paper presents a fully automated, video-based pipeline for wildlife gait analysis and individual identification using deep spatiotemporal representation learning. The proposed pipeline uses the Segment Anything Model 3 (SAM3) to generate high-quality RGB and binary silhouette masks, robustly isolating animals from complex natural backgrounds. Segmented video sequences are processed using a convolutional neural network (ResNet18) for spatial feature extraction and a transformer-based video model (VideoPrism) for temporal motion modeling. Both models are fine-tuned using a classification objective and subsequently used as feature extractors to generate discriminative gait representations. Cosine similarity is then used to compare gait signatures, enabling similarity-based clustering of individuals without reliance on physical markings or invasive tagging. Experiments conducted on multi-source wildlife video data across multiple species demonstrate strong intra-individual consistency and clear inter-individual separation. Quantitative results using cosine similarity distributions and silhouette scores confirm the effectiveness of the proposed method. These findings demonstrate that gait dynamics provide a viable, non-invasive approach for individual identification in wildlife and highlight the potential of video-based deep learning pipelines for scalable ecological monitoring.
Muhammad Aamir, Matthew Wijers, Sangyun Shin +2
Jul 3, 2026cs.RO

DRBA: Dynamic Robotic Balance Assistant -- An assist-as-needed gait and balance rehabilitation robot for versatile training

The decline of human balance control due to aging and pathological conditions increases fall risk, a major concern in geriatric care and rehabilitation. Gait training is essential for balance recovery, enhancing walking ability and postural control. However, existing overground robotic gait trainers have limitations: body weight support systems are bulky and impractical for daily use, while end-effector-based systems often compromise transparency, altering natural gait dynamics. This paper presents the Dynamic Robotic Balance Assistant (DRBA), a novel gait trainer providing assist-as-needed body weight and balance support for various training scenarios. DRBA integrates a 3-degree-of-freedom (3-DoF) robotic arm for pelvic support with flexible motion, a compact sit-to-stand assistance module, and user-following and fall detection algorithms to ensure minimal interference and responsive support. Experimental results demonstrated high transparency, with minimal impact on natural gait dynamics. A patient trial with nine elderly patients with varying medical conditions and balance impairments (ranging from severe to mild) further validated DRBA's effectiveness. The results showed that DRBA-assisted training increased step length and walking speed compared to therapist-assisted gait training. Additionally, DRBA enabled users to perform tasks beyond their unaided ability, expanding rehabilitation possibilities. These findings highlight DRBA's potential to enhance rehabilitation outcomes by facilitating higher training intensity and enabling task-oriented exercises.
Yifan Wang, Li Li, Youlong Wang +9
Jul 1, 2026cs.RO

[Preprint] Dynamic Modeling, Gait Synthesis, and Control of a Novel Subsurface Bore Propagator

In this article, we present dynamic modeling, gait synthesis, and feedback control design for a modular novel subsurface robot, designed for human-free subsurface exploration and excavation. The subsurface propagator design is based on two major aspects: 1) anchor and propel movement like an earthworm and 2) excavation similar to tunnel boring machines. This design is decoupled into five separate modules: one drill head to excavate and create cavity for propagation, two modules to anchor the robot, and two modules to enable propagation of the body. In order to design a controller for each of the modules, dynamic models using the Euler-Lagrange framework are developed. These mathematical models are used as a baseline to design controlled decoupled operation of the different joint movements. The operation of robotic assembly is constructed via a centralized state machine for gait synthesis with integration of the designed feedback controller. The controllers are tested on the real robot geometry to aid sim-to-real integration: A physics-based Unity simulation using a CAD model of the robot and integration of the trained controller via ROS verifies the performance of the robot. The experimental results demonstrate that the proposed design, controllers and the gait synthesis strategy together are capable of anchoring the robot in place and creating an total advancement of 30,mm into the soil after completing 3 gait cycles.
Lina van Brügge, Shruti Kotpalliwar, Anton Koval +2
Jul 1, 2026cs.RO

Learning Gait-Aware Quadruped Locomotion with Temporal Logic Specifications

Reinforcement learning (RL) for quadruped locomotion commonly depends on fixed, hand-crafted, and Markovian reward functions that limit both interpretability of learned policies and lack explicit control over gait behaviors. We introduce a framework where distinct gaits are specified using parameterized constraints expressed in Signal Temporal Logic (STL). These include safety bounds, gait synchronization constraints, command tracking, and actuation bounds. From these specifications, we develop a reward shaping mechanism that provides learning agents a dense, continuous reward landscape that encodes desired behavior. We define parametric STL templates for three speed regimes (walking-trot, trot, bound), calibrate their parameters from reference rollouts, and compute rewards from using smooth approximations of STL robustness over the rollouts. The generated rewards can be used to provide shaped gradients compatible with Proximal Policy Optimization (PPO). We instantiate the approach on Google's Barkour quadruped robot in MuJoCo XLA (MJX). We use parallelization within the simulator to improve training speeds and use domain randomization to robustify learned policies. We show that compared to a baseline of hand-crafted rewards, the STL-shaped rewards yield tighter velocity tracking and more stable training. Videos can be found on our project website: https://stl-locomotion.github.io/.
Merve Atasever, Cagan Bakirci, Alfredo Reina Corona +2
Jun 20, 2026cs.RO

Durability-Aware Multi-Objective Optimization of the Jansen Linkage: Trading Gait Quality Against Joint Wear

The Jansen linkage is a single-degree-of-freedom planar leg mechanism whose eleven "holy numbers" were evolved by Theo Jansen to optimize the foot-path gait alone, with no regard for the wear of its revolute joints. This paper introduces a durability objective into the design of the Jansen leg. A parametric forward-kinematic model (two-circle-intersection solver), an inverse-dynamic model (constraint-Jacobian / Lagrange-multiplier formulation of a seven-body, ten-joint system, independently cross-verified by a reduced-DOF energy method), and an Archard wear model are coupled to evaluate, for any set of link lengths, both gait quality and the per-cycle sliding wear at every pin. Because the wear is computed on ideal, clearance-free revolute joints, the resulting wear figures are a relative comparative ranking rather than an absolute life prediction. A bi-objective problem -- composite gait error versus total joint wear, subject to step-length, ground-clearance, duty-factor and assembly constraints -- is solved with NSGA-II. Under the adopted gait metric the classical Jansen design is Pareto-dominated: for a representative design, link-length adjustments within +/-29% simultaneously flatten the stance (-28%), smooth the stance velocity (-58%) and reduce total joint wear by ~56%. A sensitivity study shows the wear advantage is robust across a crank-speed x payload envelope (48%-56%) and identifies the link lengths that most strongly govern wear. A variance-based global (Sobol) analysis confirms that two link lengths dominate the wear variance, and a Monte-Carlo manufacturing-tolerance study shows the wear advantage degrades gracefully under realistic fabrication error. The framework provides a practical route to longer-lived walking linkages and a baseline for future wear-clearance-impact coupled studies.
Jichao Wang
Jun 16, 2026cs.RO

Continual Online Personalization of Exoskeleton Control via Manifold-Aware Experience Replay

Personalizing exoskeleton control remains a critical challenge for clinical users with gait disabilities. Online adaptation (OA) offers an effective solution by adapting in real time to subject variability, device fit, and diverse locomotor tasks. However, OA involves a continual stream of user state data, which can lead to catastrophic forgetting of previously learned locomotor contexts. Here, we develop a manifold-aware experience replay-based online personalization framework designed to maintain user-specific representations across diverse tasks during OA of exoskeleton control. By replaying previously experienced tasks from a replay buffer, we preserve the personalized exoskeleton assistance across all learned tasks. Furthermore, we capture a gait manifold that distinguishes between different locomotor tasks, removing the need for explicit task labeling when selecting target replay bins. We evaluated our framework on emulated hemiplegic gait, which largely deviates from able-bodied patterns, across multiple forgetting scenarios with speed and incline transitions. Our manifold-aware replay framework achieved 40% and 60% improvements in torque and gait phase tracking accuracy, respectively, compared to a baseline framework without replay, which exhibited catastrophic forgetting during task transitions. This demonstrates that our proposed framework personalizes exoskeleton control in real time across diverse locomotor contexts in daily ambulation of clinical populations.
Changseob Song, Inseung Kang
Jun 4, 2026cs.CV

LLM-Conditioned Synthesis of Pathological Gaits via Structured Gait-Language Representations

Pathological gait datasets remain scarce due to privacy, recruitment, cost, and movement variability. Our work presents a multimodal LLM-guided framework for pathology-aware 3D gait data synthesis from structured textual descriptions. The proposed method generates fixed-length synthetic skeleton-based gait sequences for pathological gait classification tasks. The framework combines motion tokenisation, pathology-aware language conditioning, LLM-based semantic augmentation, and language-to-gait generation. A key contribution is the proposed pathological tokeniser, which is designed to preserve pathology-specific motion characteristics during discrete representation learning. Experiments suggest that the proposed synthetic sequences improve downstream classification for recurrent classifiers when combined with real data. The best result is obtained using a GRU classifier trained with real and synthetic samples, achieving 92.77% accuracy under a leave-one-subject-out protocol.
Mritula Chandrasekaran, Sanket Kachole, Jarek Francik +1
May 29, 2026cs.CV

Text-guided Feature Disentanglement for Cross-modal Gait Recognition

Gait recognition is a biometric technique that identifies individuals based on their walking patterns, offering advantages in long-range, non-intrusive scenarios. However, real-world scenarios often involve heterogeneous sensing modalities such as LiDAR and RGB cameras, making LiDAR-Camera Cross-modal Gait recognition (LCCGR) a critical yet challenging task due to the substantial modality gap between 2D videos and 3D point cloud sequences. To address this challenge, we propose TCFDNet, a Text-guided Cross-modal Feature Disentanglement Network, which leverages modality-aware textual priors as semantic anchors to guide the learning of disentangled modality-shared representations. Specifically, we construct a Gait Modality Text Dictionary (GMTD) using large language models to generate rich semantic descriptions of gait across modalities and viewpoints. A CLIP-based Multi-grained Feature Encoder then aligns visual and textual features within a unified vision-language space. Furthermore, the Text-guided Feature Disentanglement (TFD) module selects the topk matched textual descriptions to reconstruct modality-specific representations and derive modality-shared features via residual decomposition and orthogonality constraints. To mitigate the fragility of the disentangled shared features, we propose a Feature Stability Enhancement (FSE) module, which models spatial and channel-wise correlations to improve feature robustness. In addition, a cross-modal patch exchange strategy is introduced to further improve generalization. Extensive experiments on SUSTech1K and FreeGait datasets demonstrate that TCFDNet achieves new state-of-the-art results and validate the effectiveness of the proposed modules.
Zhiyang Lu, Ming Cheng
May 24, 2026cs.LG

Gait2Hip-60: A Unified Deep Learning Benchmark for Predicting Hip Muscle Forces and Joint Moments from Multi-Cadence Gait Kinematics

Estimating hip muscle forces and joint moments during gait typically relies on musculoskeletal simulation, which is informative but time-consuming and difficult to apply in clinical settings. This study developed a deep learning framework to predict these hip dynamics parameters directly from lower-limb gait kinematics and compared three representative sequence models under a unified protocol. Gait data were collected from 60 healthy adults under three metronome-guided cadence conditions. Ten bilateral lower-limb joint angles were used as inputs, and OpenSim-derived hip muscle forces and hip joint moments were used as reference outputs. Three deep learning models of LSTM, Transformer, and Mamba were trained and evaluated using the same subject-level split, preprocessing pipeline, and metrics. The best model was then directly tested on an external cohort of 9 patients with osteonecrosis of the femoral head (ONFH) without retraining. In the healthy-subject benchmark, Transformer achieved the best subject-level mean performance for both hip muscle force prediction (RMSE = 1.33 N/kg, MAE = 0.57 N/kg, R2 = 0.819) and hip joint moment prediction (RMSE = 0.11 Nm/kg, MAE = 0.07 Nm/kg, R2 = 0.862), with similar advantages across walking cadences. In zero-shot external validation, Transformer retained moderate predictive ability in ONFH for hip muscle force prediction (RMSE = 1.51 N/kg, MAE = 0.70 N/kg, R2 = 0.537) and hip joint moment prediction (RMSE = 0.17 Nm/kg, MAE = 0.12 Nm/kg, R2 = 0.569). These findings support the feasibility of estimating hip dynamics from gait kinematics, identify Transformer as a strong baseline, and highlight the need for broader pathological validation and improved generalization before clinical application.
Jiaqi Zhang, Ji Hou, Qing Sun +2
May 15, 2026cs.LG

From Observed Viability to Internal Predictive Approximation: A Single-Subject Latent-Space Analysis of Gait Dynamics Under Occlusal Constraint

Understanding adaptive biomechanical systems requires distinguishing observable performance, static multivariate representation, longitudinal displacement, and internal approximation of observed change. This study introduces Level 5, which examines whether the M1-M2 transformation observed in a single-subject gait dataset can be approximated within a selected PCA representation. Gait was recorded with instrumented insoles in a participant with Parkinson's disease under six occlusal observational probes during two sessions eleven weeks apart. A simplified feed-forward neural network was trained to approximate M2 PC1-PC2 coordinates from M1 coordinates, occlusal-probe descriptors, and the longitudinal-transition indicator. In the core analysis aligned with Level 4, the model preserved the Euclidean centroid-displacement hierarchy dOC3 < dONL < dOC2.5. In the extended six-probe analysis, it preserved the broad structure of the exploratory ordering. Held-out M2 and leave-condition-out analyses provided internal tests beyond the full-dataset fit, while a within-session analysis described probe positions relative to ONL. The term predictive is used only in a restricted methodological sense. The model does not provide prospective clinical prediction, patient-level forecasting, or generalization to unseen individuals. Occlusal conditions are treated as observational probes applied during measurement, not as continuous causal drivers of longitudinal evolution. The findings are exploratory, retrospective, representation dependent, and non causal. They do not establish causal occlusal effects, validated viability thresholds, therapeutic superiority, distinct physiological states, or generalizable predictive validity.
Jacques Raynal, Pierre Slangen, Elsa Raynal +1
May 14, 2026cs.CV

Local Spatiotemporal Convolutional Network for Robust Gait Recognition

Gait recognition, as a promising biometric technology, identifies individuals through their unique walking patterns and offers distinctive advantages including non-invasiveness, long-range applicability, and resistance to deliberate disguise. Despite these merits, capturing the intrinsic motion patterns concealed within consecutive video frames remains challenging due to the complexity of video data and the interference of external covariates such as viewpoint changes, clothing variations, and carrying conditions. Existing approaches predominantly rely on either static appearance features extracted from individual silhouette frames or employ complex sequential models (\eg, LSTM, 3D convolutions) that demand substantial computational resources and sophisticated training strategies. To address these limitations, we propose a Local Spatiotemporal Convolutional Network (LSTCN), a structurally simple yet highly effective dual-branch architecture that endows standard two-dimensional convolutional networks with the capacity to extract temporal information. Specifically, we introduce a Global Bidirectional Spatial Pooling (GBSP) mechanism that reduces the dimensionality of gait tensors by decomposing spatial features into horizontal and vertical strip-based local representations, enabling the temporal dimension to participate in standard 2D convolution operations. Building upon this, we design a Local Spatiotemporal Convolutional (LSTC) layer that jointly processes temporal and spatial dimensions, allowing the network to adaptively learn strip-based gait motion patterns. We further extend this formulation with asymmetric convolution kernels that independently attend to the temporal, spatial, and joint spatiotemporal domains, thereby enriching the extracted feature representations.
Xiaoyun Wang, Cunrong Li, Wu Wang
May 11, 2026cs.CV

Quantifying Rodda and Graham Gait Classification from 3D Markerless Kinematics derived from a Single-view Video in a Heterogeneous Pediatric Clinical Cohort

Cerebral Palsy (CP) is a neurological disorder of movement and the most common cause of lifelong physical disability in childhood. Approximately 75% of children with CP are ambulatory, and accurate gait assessment is central to preserving walking function, which deteriorates by mid-adulthood in a quarter to half of adults with CP. The Rodda and Graham classification system quantifies sagittal-plane gait deviations using ankle and knee z-scores derived from 3D Instrumented Gait Analysis (3D-IGA), but 3D-IGA is expensive and limited to specialized centers, while observational assessment shows only moderate inter-rater agreement. We developed a markerless gait analysis pipeline that quantifies Rodda and Graham knee and ankle z-scores directly from single-view clinical gait videos. Across 1,058 bilateral limb samples from 529 trials of 152 children (88 male, 63 female; age 12.1 ±\pm 4.0 years; 60 distinct primary diagnoses, cerebral palsy the most common at n=54n=54), the sagittal-view model achieved R2=0.80±0.02R^2 = 0.80 \pm 0.02 and CCC =0.89±0.02= 0.89 \pm 0.02 for knee z-scores and R2=0.57±0.02R^2 = 0.57 \pm 0.02 and CCC =0.72±0.02= 0.72 \pm 0.02 for ankle z-scores against 3D-IGA. Binary screening for excess knee flexion achieves AUROC =0.88= 0.88, correctly identifying 83% of affected children, and applying Rodda and Graham rules yields 43±143 \pm 1% 7-class accuracy with macro-AUROC =0.78±0.01= 0.78 \pm 0.01, ankle prediction error remaining the primary bottleneck. Beyond cross-sectional screening, continuous z-scores support longitudinal trajectory tracking across visits, providing a quantitative substrate for monitoring disease progression and treatment response unavailable from observational scales. These results demonstrate the feasibility of video-based z-score estimation, excess-flexion screening, and longitudinal trajectory tracking as a path toward scalable, objective gait assessment in low-resource clinical settings.
Lauhitya Reddy, Seth Donahue, Jeremy Bauer +8
May 4, 2026cs.RO

Adaptive Gait Generation for Multi-Terrain Exoskeletons via Constrained Kernelized Movement Primitives

Lower limb exoskeletons (LLEs) present the potential to make motor-impaired individuals walk again. Their application in real-world environments is still limited by the lack of effective adaptive gait planning. Indeed, current exoskeletons are meant to walk only on a flat and even terrain. Generating environment-aware, physiologically consistent gait trajectories in real-time is an open challenge. To overcome this, we propose a novel Kernelized Movement Primitives (KMP)-based framework for adaptive gait generation (AGG) across multiple indoor terrains. The proposed approach learns a probabilistic representation of human gait in both the joint and task spaces from a limited number of human demonstrations, representing natural gait characteristics and ensuring kinematic feasibility. In addition, the learned trajectories are adapted using environmental information extracted from an onboard RGB-D camera by treating the AGG as a linearly constrained optimization problem with via-points. The proposed method has been thoroughly validated first in simulations for gait generation in different scenarios, such as flat-ground walking, slopes, stairs, and obstacles crossing. Finally, the effectiveness and robustness of the method have been demonstrated with experiments on a commercial LLE in real-world scenarios. The results obtained demonstrate the feasibility of an environment-aware gait planning system for a new generation of intelligent lower limb exoskeletons for assisting people with disabilities in their every-day life.
Edoardo Trombin, Miroljub Mihailovic, Matheus Henrique Ferreira Moura +3
May 1, 2026cs.LG

Observable Performance Does Not Fully Reflect Adaptive System Organization: A Multi-Level Analysis of Gait Dynamics Under Occlusal Constraint

In biomechanical systems, observable performance is often used as a proxy for underlying organization, although similar outputs may arise from different adaptive configurations. This study considers the vertical dimension of occlusion (VDO) as a constraint applied to an adaptive neuromechanical system. A single-case design in a patient with Parkinson's disease enabled repeated intra-individual gait observations under six occlusal probes. Three complementary analytical levels were examined: (i) an aggregated scalar score of observable performance, (ii) a conceptual dynamical systems framework, and (iii) an exploratory UMAP representation of 55 standardized biomechanical variables from 270 M1 observations. The revised Level 1 analysis showed that the relative ranking of OC2.5 and OC3 depended on score construction, while their scalar distributions remained close. The Level 3 embedding showed substantial overlap among all six probes and did not identify independently separated condition-specific clusters. OC2.5 and OC3 displayed limited centroid displacement but broad observation-level overlap. The principal result is therefore representational non-identifiability: neither the aggregated score nor the selected low-dimensional embedding uniquely identifies an occlusal-condition-specific system state. VDO is interpreted as a constraint parameter rather than a causal determinant. The findings are exploratory, model dependent, and non causal. They do not establish distinct physiological states, an optimal VDO, clinical thresholds, or diagnostic, predictive, mechanistic, or prescriptive validity.
Jacques Raynal, Pierre Slangen, Elsa Raynal +1
Mar 12, 2026cs.RO

Human Motion Data Alone Does Not Guarantee Plausible Gait Biomechanics

Motion imitation learning (IL) is increasingly used in robotics and human gait modeling, yet its ability to recover biomechanically consistent joint moments without explicit kinetic information remains unclear. In this study, we examined whether motion imitation alone can estimate reasonable biological joint moments. We compare motion-only IL (MOIL) against a kinetics-aware IL (KAIL) framework that incorporates ground reaction forces (GRF) and center of pressure (CoP) in imitation rewards, with an ablation study to examine the contribution of each kinetic term. Experiments were conducted using walking data from a non-disabled participant at three speeds (0.9, 1.2, and 1.5 m/s). While both MOIL and KAIL achieved comparable kinematic tracking accuracy, MOIL exhibited substantially larger errors in GRF, CoP, and joint moment estimates relative to inverse dynamics references. In contrast, KAIL produced kinetics more consistent with biomechanical values. These findings highlight a fundamental limitation of MOIL approaches, which may lead to erroneous interpretations of gait biomechanics and downstream applications by failing to estimate consistent human-like gait kinetics.
Xinyi Liu, Jangwhan Ahn, Edgar Lobaton +2