Wearable Devices

Recent momentum

emerging

0 papers in the last 28 days · 0.0% of indexed attention

Twelve weeks of publication activity for this topic as it is defined today.

Weekly history

Recent digests

What was published in this field, kept on the site without email delivery.

Period ending 2026-09-21

11 new papers

A weekly snapshot of new work published in Wearable Devices.

Period ending 2026-09-14

9 new papers

A weekly snapshot of new work published in Wearable Devices.

Period ending 2026-09-07

10 new papers

A weekly snapshot of new work published in Wearable Devices.

Inside this field

Focused directions

276 papers

Latest in Wearable Devices

Jun 14, 2026cs.LG

An Exploratory Study of Blood Glucose Estimation from Photoplethysmography Signals using Machine Learning

Diabetes and extreme blood sugar levels are some of the major health problems faced by humans today across the world. While Continuous Glucose Monitoring (CGM) has emerged as an effective technology for management of diabetes as well as for monitoring blood sugar levels, this technology has traditionally been invasive (that is, requiring the piercing of the skin) and carries the risk of irritation, induration, etc. This highlights the need for accurate and non-invasive CGM methods that can be deployed at scale. With the emergence of various sensing technologies and their integration in wearables like the smart-watch, we now have the capability to continuously monitor body signals like the Photoplethysmogram (PPG) in a non-invasive manner. Having the ability to continuously monitor blood glucose through CGMs and continuously monitor PPG signals through a smart-watch offers an opportunity to get dense data on these two, opening the possibility of building machine learning and deep learning based models to estimate blood glucose level from PPG signals. In this work, we first present a paired dataset comprising continuous PPG signals from a smartwatch along with glucose values recorded using a CGM device. We also present the results of some preliminary experimental explorations performed on our dataset. These preliminary results suggest that some predictive signals may exist, though more exploration is needed with more data from a larger number of individuals. The dataset can be accessed at https://zenodo.org/records/20577959
Ruhani Bhatia, Vijval Ekbote
Jun 14, 2026cs.CV

Fusion-E2Pulse: A Multimodal Event-RGB Fusion Network for Non-contact Pulse Wave Reconstruction

Non-contact pulse wave reconstruction hinges on the precise recovery of waveform morphology, including the dicrotic notch. Conventional Red-Green-Blue (RGB)-based methods, which extract physiological signals from recorded facial videos, are constrained by the integral imaging mechanism of standard cameras, where the exposure process induces a smoothing effect that attenuates subtle vascular pulsation details. Conversely, neuromorphic event cameras, while offering exceptional sensitivity to intensity fluctuations, are inherently susceptible to noise and artifacts induced by minor motion. To exploit the synergy between frame-based integration and event-based differential sensing, we propose a novel multimodal network named Fusion-E2Pulse. This framework utilizes filtered RGB signals as structural priors to suppress motion artifacts, while leveraging the high-sensitivity of event streams to recover fine-grained morphological details. Experimental results demonstrate that Fusion-E2Pulse achieves state-of-the-art performance, effectively balancing noise suppression and morphological fidelity, achieving a mean absolute error of 0.78 bpm for heart rate estimation, a waveform correlation of 0.89, and a systolic phase duration error of 16.74 ms, validating its efficacy in reconstructing fine-grained pathological features.
Qian Feng, Hao Guo, Yan Niu +2
Jun 13, 2026eess.SP

CAP: Towards PPG Universal Representation Learning with Patient-level Supervision

Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support. Yet existing approaches to universal PPG representation learning largely focus on signal-level objectives and often overlook patient-level health context, which limits generalization to complex clinical tasks and heterogeneous cohorts. To address this gap, we construct a large-scale paired PPG-EHR multimodal dataset by distilling fragmented medical histories and clinical records into cohesive, patient-level electronic health records (EHR). Building on this resource, we propose Clinical Anchored Pretraining for PPG (CAP). During pretraining, CAP performs cross-modal contrastive alignment that anchors PPG representations to patient-level clinical semantics, guiding the encoder beyond waveform fitting toward modeling consistency in a patient's overall physiological state. During downstream adaptation, the pretrained PPG encoder provides clinically grounded representations that strengthen inductive bias and improve robustness and transferability. Experiments demonstrate that CAP consistently outperforms strong baselines on four diverse downstream tasks. CAP achieves a particularly large gain on respiratory rate prediction (up to +87.6% relative improvement over the state-of-the-art baseline) and delivers an average relative +26.7% across all tasks. We further enhance the interpretability of our approach through comprehensive analyses, including ablations and multiple complementary visualizations of the learned representations. The code for our experiments is available at: https://github.com/gody123gody/CAP .
Chenyang He, Xinyi Shao, Shun Huang +4
Jun 13, 2026eess.SP

ECG-LDC: A Hardware-Efficient Low-Dimensional Computing Framework for ECG Arrhythmia Classification

Continuous cardiac monitoring in wearable devices demands classifiers that are simultaneously accurate, energy-efficient, and deployable on resource-constrained hardware. While deep neural network approaches have demonstrated high classification accuracy for electrocardiogram (ECG) arrhythmia detection, their substantial parameter counts and reliance on multiply-accumulate-intensive operations make them impractical for low-cost edge platforms. In this work, we propose ECG-LDC, a hardware-software co-design framework that adapts Low-Dimensional Computing (LDC) for real-time ECG arrhythmia classification. ECG-LDC employs a dual-encoder architecture with dedicated value and feature codebooks to independently encode morphological waveform features and RR-interval temporal features, enabling effective capture of both intra-beat and inter-beat cardiac dynamics. The framework encompasses data preprocessing, model training, and a hardware accelerator architecture prototyped on the Pynq-Z2 platform. Implemented using binary representations and XOR/XNOR-based operations, ECG-LDC achieves 97.18%97.18\% accuracy with a memory footprint of only 3.86 kB3.86\ \text{kB}. ECG-LDC sacrifices approximately 1.8%1.8\% accuracy versus SOTA TinyML classifiers but achieves 1111~570× 570\times reduction in memory usage; among FPGA-based five-class arrhythmia classifiers, it delivers the highest accuracy with up to 2.4×2.4\times fewer LUTs and zero DSP block utilization, affirming its suitability for real-time arrhythmia detection on resource-constrained wearable platforms.
Anh Tran, Khanh Tran, Cuong Do
Jun 12, 2026cs.RO

Multimodal Physiological Assessment of Contact-Rich Physical Human-Robot Interaction Under Varying Environmental Conditions

Physical human-robot interaction (pHRI) in real-world settings exposes operators to fluctuating environmental conditions during contact-rich tasks. Traditional task-centric evaluations overlook the physiological burdens imposed by these stressors. Therefore, we conducted a multimodal empirical study involving contact-rich tracing tasks under 18 distinct combinations of temperature, acoustic noise, and illuminance. Synchronously, we recorded electrodermal activity (EDA), surface electromyography (sEMG), eye-tracking data, and subjective environmental comfort ratings. Evaluating these physiological signals alongside execution data revealed hidden physiological costs not captured by objective performance. The results revealed that task performance remained stable across all environmental conditions. Autonomic workload, indexed by tonic skin conductance level (SCL), increased with temperature, while physical and cognitive workload were unaffected. Perceived environmental comfort showed no significant association with tracing error or completion time. These findings reveal a compensatory mechanism where operators maintain consistent performance by increasing their physiological effort to suppress thermal discomfort. Such insight motivates the development of physiology-aware control architectures that leverage real-time physiological metrics to reduce operator workload in unstructured environments.
Yanyi Chen, Xi Wang, Min Deng
Jun 12, 2026cs.LG

Leveraging Physiological Signals to Predict Exam Outcomes with Machine Learning

This study investigates the application of machine learning models to predict exam outcomes using physiological data collected during examination sessions. Physiological stress indicators, including electrodermal activity, heart rate, and skin temperature, were analyzed to uncover their association with academic performance. A variety of machine learning approaches were employed, ranging from standard models like logistic regression, random forest, and support vector machines to more advanced architectures, including transformers, long short-term memory (LSTM), and gated recurrent unit (GRU) models. This diversity aimed to capture the complex interactions within the data effectively. A key focus was assessing the adaptability of transformers in processing numerical data and evaluating their performance in this novel context. Standard performance metrics, such as accuracy, precision, recall, and F1-score, were used to compare model efficacy. The experimental results demonstrate that while deep learning models generally excel at capturing complex relationships in physiological data, simpler models like random forests can sometimes achieve superior performance while offering computational efficiency and interpretability. Furthermore, transformers demonstrated notable versatility, showcasing performances comparable to those of the LSTM and GRU models. This research underscores the importance of experimenting with a broad class of models that align with the objectives of the problem at hand, balancing precision, efficiency, and interpretability. By elucidating the relationships between physiological signals and academic performance, this study contributes to understanding stressors affecting students' mental health. It further promotes leveraging physiological data to enhance student well-being and academic outcomes.
Lala Yamazaki, Ramchandra Rimal
Jun 12, 2026cs.LG

A Comparative Study of Deep Learning Architectures for Multi-Horizon Behavioural Forecasting for Mobile Health

Wearable devices and smartphones generate rich behavioural time series that can support proactive health interventions, yet systematic comparisons of modern forecasting architectures for these data are lacking. In particular, it remains unclear how models generalise across populations, how different architectures respond to participant-level fine-tuning and how forecasting accuracy degrades across multi-day horizons. We benchmark six deep learning architectures, two zero-shot Foundation Models (FM) and statistical baselines on three public datasets encompassing over 800 participants, reporting per-feature metrics for step counts, screen time and sleep duration across 1-8 day horizons. We further conduct a per-feature personalisation study across all six architectures and assess FM transferability across dataset sizes and temporal granularities. Our key findings are: (i) no single architecture dominates, PatchTST leads among trained models while the three runners-up (TCN, MLP, Transformer) show no meaningful performance difference; (ii) the FM TimesFM matches or exceeds trained models zero-shot, especially in low-data regimes and (iii) participant-level fine-tuning reduces per-feature RMSE by 16-60%, with sleep benefiting most and step counts least. These results provide practical guidance on architecture selection, FM applicability and personalisation strategies for mobile health forecasting. To the best of our knowledge, this is the first study to jointly evaluate modern deep learning, FMs and personalisation for multi-horizon behavioural forecasting from wearables.
Pavlos Nicolaou, Kleanthis Malialis, Artemis Kontou +1
Jun 11, 2026eess.IV

Full-Self Diagnostics (FSD): Physics-Grounded Visual Biomarker Inference from Smartphone Video via Inverse Problems and Operator Learning

We present Full-Self Diagnostics (FSD), a unified mathematical framework for recovering latent physiological states from unconstrained 9-second facial videos captured by consumer smartphones. The approach integrates five mutually reinforcing components: (1) a physics-based forward model derived from the radiative transfer equation and chromophore absorption that maps camera observables to biomarker concentrations; (2) an information-theoretic observability theory proving that multi-channel visual signals (spectral, pulse, respiratory, micro-expression, and oculomotor) contain strictly increasing mutual information with physiological state; (3) a stable, Tikhonov-regularized inverse problem with domain-uniform identifiability guarantees; (4) an operator-learning formulation that enables generalization across devices, resolutions, and populations; and (5) a supervised learning procedure, interpretable as stochastic variational inference, that continuously refines the model from paired biosensor ground truth with performance improving proportionally to one over the square root of the number of paired observations. Empirical validation on 38812 real-world paired scans across 59 subjects demonstrates practical performance. Self-collected data from the lead author (glucose range 35-550 mg/dL) yields MARD of 29.86 percent with 97.57 percent of predictions in Clarke Error Grid Zones A+B and only 0.27 percent in the dangerous Zone E. A well-managed diabetic participant achieves MARD of 17 percent in the narrower 70-180 mg/dL band. These results confirm that consumer-grade facial video encodes sufficient structured information for clinically relevant, non-invasive biomarker inference under fully unconstrained conditions, with performance scaling predictably as more paired data becomes available.
Jonathan Thomas, Harsh Thaker
Jun 11, 2026cs.CV

Explaining RhythmFormer: A Systematic XAI Analysis of Periodic Sparse Attention for Remote Photoplethysmography

Remote photoplethysmography (rPPG) transformers achieve low heart-rate error on benchmarks, yet their decisions remain opaque--a growing concern as rPPG moves toward clinical heart rate estimation. Existing rPPG XAI is dominated by qualitative heatmap inspection without quantitative faithfulness metrics or physiology-grounded validation, leaving a gap between visual plausibility and auditable evidence. We address this gap. First, we adapt four attribution methods (raw attention, rollout, flow, Beyond Intuition) to RhythmFormer's bi-level routing attention with top-kk selection. Second, we introduce a skin coverage metric quantifying how much attribution mass falls on skin regions. Third, we adapt the SaCo faithfulness coefficient from its original classification setting to rPPG regression by using the MAE between original and perturbed predicted rPPG waveforms as the perturbation impact. Applying these tools, we quantify a multi-hop leakage effect under sparse top-kk routing: attention rollout and flow almost completely restores the connections that individual refined-attention layers explicitly set to zero. Beyond Intuition mitigates this via its value-projection-weighted rollout and gradient-supported mask, attaining the highest median refined skin coverage (0.830.83 vs. 0.570.57 for vanilla rollout) and faithfulness (F=0.92F=0.92) among the evaluated methods on UBFC-rPPG. Validation across diverse datasets and model variants is needed. A case study on a low-SaCo outlier further shows all four methods recovering consistently once an artefactual region is replaced, suggesting consistent SaCo behavior across attribution families in this illustrative case. Together, these metrics move XAI for rPPG toward auditable numerical evidence about spatial alignment and perturbation faithfulness, i.e. trustworthy rPPG XAI.
Louis Chen, Torbjörn E. M. Nordling
Jun 11, 2026cs.AI

Is It You or Your Environment? A Bayesian Inference Framework for Genomically-Anchored Personalized Physiological Interpretation

Personalized health AI systems face a fundamental cold-start problem: machine learning models for physiological interpretation require weeks of individual behavioral data before they can distinguish constitutional variation from environmentally driven deviation. We propose a solution grounded in causal inference and Bayesian prior design. An individual's genomic profile serves as an exogenous genetic anchor -- a domain-informed, personalized prior that is fixed at conception, immune to reverse causation, and available before a single behavioral observation is collected. The anchor initializes a Bayesian belief state over an individual's physiological set point G-hat = mu + sum(beta_i * g_i), where beta_i are GWAS-derived effect sizes and g_i are risk-allele counts. Each incoming physiological measurement P produces a non-constitutional deviation delta = P - G-hat that separates the signal attributable to environment and state from the constitutionally fixed baseline. As behavioral data accrue, the prior decays according to G-hat_t = w(t)*G-hat_genomic + [1-w(t)]*P-bar_t, transitioning from genome-dominated to empirical-baseline-dominated inference. The same observed HRV of 55 ms generates a suppression hypothesis for a person whose prior predicts 80 ms, and an enhancement hypothesis for a person whose prior predicts 30 ms -- a reversal impossible without a personalized anchor. We develop this architecture across six physiological domains, grading genomic priors by evidence strength, distinguishing robustly replicated anchors (FTO, FADS1/2, FKBP5) from contested candidate genes (SLC6A4, MAOA, DRD2). We address the inference boundary between association, Mendelian randomization, and individual token causation, and define four constraints for deployment: evidence-graded priors, dynamic decay, ancestry-matched effect sizes, and attribution rather than deterministic output.
Aruna Dey, Suraj Biswas
Jun 11, 2026cs.HC

Ride, Track, and Recover: Pilot Randomized Trial of a Wearable Digital Self-Management Intervention During a Veteran Endurance-Cycling Program

Post-traumatic stress disorder (PTSD) in veterans is characterized by persistent hyperarousal and comorbid anxiety and depressive symptoms that are difficult to monitor and manage outside clinical settings. Thirteen veterans participating in a Project Hero cycling event in Texas were randomized by computer-generated sequence in a naturalistic setting to two arms: (1) digital intervention plus physical activity, or (2) physical activity only, plus a third at-home monitoring control cohort consisting of 7 veterans selected from the broader Project Hero veteran community. Continuous smartwatch sensing combined heart rate and accelerometer features to detect hyperarousal events, which were confirmed in real time by participants. Weekly self-report measures of anxiety, depression, and PTSD severity were collected. Generalized additive mixed models characterized nonlinear trajectories over time. Baseline-normalized hyperarousal trajectories differed significantly across conditions, with the digital intervention group (n=7) showing structured stabilization compared to late-study escalation in the physical-only group (n=3). Both cycling groups exhibited acute symptom improvements during the endurance event; however, the digital intervention group demonstrated a higher overall maintenance of gains. The at-home control group (n=4) showed gradual symptom declines. Perceived precision of ML detections varied substantially across individuals and was positively associated with symptom severity, with higher-severity participants confirming a greater proportion of detected events. These results suggest that coupling wearable detection with digital self-management tools may support stabilization of hyperarousal and symptom improvement while emphasizing the importance of personalization and human-centered design in wearable mental health systems.
Alan Ta, Nilsu Salgin, Caleb Armstrong +2
Jun 11, 2026stat.AP

Event-Aligned Analysis of Multi-Rater Pain Assessments Using Continuous Wearable Physiology

Pain is assessed differently by patients, nurses, and clinicians, yet most computational approaches assume a single ground-truth label - effectively ignoring who is doing the rating. We introduce a rater-aware, event-aligned framework that converts sparse, rater-specific pain ratings into discrete pain-change events and aligns continuous wearable physiological signals to these events, preserving rater identity throughout. Applied to multimodal wearable data collected during spine-related pain procedures, the framework identifies substantial disagreement across rater groups and provides preliminary, exploratory evidence of rater-dependent physiological differences preceding reported pain increases. These findings suggest that pain-physiology relationships may not be rater-invariant, and that aggregating assessments across raters may mask meaningful physiological patterns. A rater-aware, event-aligned perspective is therefore a promising direction for interpreting wearable data in real-world clinical pain assessment.
Saba A. Farahani, Elahe Khatibi, Thomas D. Hughes +3
Jun 10, 2026cs.AI

Reducing the Complexity of Deep Learning Models for EEG Analysis on Wearable Devices

Wearable healthcare devices are the fastest-growing Internet of Things (IoT) sector. Many automated healthcare services rely on two crucial biological signals, namely ECG and EEG, which reflect the activity of the heart and brain, respectively. Although deep neural networks are considered the primary way to process and analyze these signals, the very tight energy and computational power constraints in wearable devices are far below the computational, energy, and memory bandwidth demands of DNN models, thereby impeding the deployment of deep learning in many practical wearable services. This paper investigates the feasibility of deploying state-of-the-art DNN models in resource-constrained wearable devices. Notably, we explore the trade-off between accuracy and computational complexity of DNNs when parameter quantization and electrode reduction methods are used. Our investigation centers on several state-of-the-art DNN models designed for EEG signal analysis, specifically for detecting epileptic seizures. Our findings demonstrate that, when applied judiciously, these techniques can significantly reduce the complexity of the DNNs under consideration with minimal adverse effects on accuracy. These results reveal the explicit trade-offs between accuracy and complexity reduction encountered when adapting DNN-based online EEG analysis for wearable devices.
Farough Shayeste Roodi, Parham Zilouchian Moghaddam, Mahdi Mohammadi-nasab +3
Jun 10, 2026cs.LG

LLM-Powered Personalized Glycemic Assessment in Type 2 Diabetes with Wearable Sensor Data

Type 2 Diabetes (T2D) poses an increasing global health threat, demanding effective glycemic assessment to support personalized and improved diabetes care. Wearable sensors such as continuous glucose monitors (CGM) and fitness trackers offer many valuable insights for glycemic assessment. However, effectively analyzing these data requires integration with essential individual-level context. Existing methods are often based on traditional machine learning (ML) and rely primarily on historical blood glucose measurements and overlook personalized information, which limits their performance across diverse diabetes populations. Recent advances in large language models (LLMs) have demonstrated their ability to integrate diverse data modalities while modeling sequential dependencies, motivating the exploration of their potential for personalized glycemic assessment. In this paper, we propose GlyLLM, an LLM-powered framework for modeling CGM-based glycemic dynamics through the integration of wearable sensor data and structured metadata. GlyLLM can leverage the extensive prior knowledge of pre-trained LLMs and achieve sensor-text semantic abstraction at decision time. Experiments on two related tasks on the AI-READI dataset demonstrate that our model outperforms traditional ML methods by an average of 13.66% in Root Mean Squared Error (RMSE) for glucose forecasting and 13.08% in Area Under the Receiver Operating Characteristic (AUROC) for diabetes categorization. Additionally, our ablation study shows that diabetes surveys and biometric tests are more critical than other health information for glycemic assessment. Our work presents a promising step toward harnessing the power of LLMs to advance personalized glycemic assessment in T2D care.
Yifan Gao, Yanmin Gong, Yun Shi +1
Jun 10, 2026cs.CV

Illumination-Robust Camera-Based Heart-Rate Estimation for Physiological Sensing in Robots

Physiological awareness is important for service, social, and assistive robots that interact with humans in everyday environments. Remote photoplethysmography (rPPG) enables non-contact heart-rate (HR) estimation from an RGB camera, making it a promising sensing modality for robot-mounted vision systems. However, illumination variation remains a major barrier to robust deployment. This paper presents an end-to-end spatial-temporal transformer framework for remote HR estimation on a new dataset with varied illumination. Our estimator integrates PRNet-based 3D face alignment, clip-level illumination augmentation, the Residual Temporal Standardization Module, and controlled hybrid temporal-frequency supervision. The training objective combines a Soft-Shifted Pearson waveform loss with a spectral Kullback-Leibler divergence loss, where a tuned weight (β\mathbfβ) controls the contribution of frequency-domain heart-rate guidance. Experiments on a static all-level mix protocol covering three illumination levels show that β=5\mathbfβ=5 provides the strongest result among the tested beta settings, achieving a best-run HR mean absolute error (MAE) of 0.79 bpm and an HR correlation of 0.982. Compared with the PhysFormer baseline evaluated on our dataset, our estimator reduces HR MAE by 93.6 %, while increasing HR correlation from 0.088 to 0.982, making it usable when illumination varies.
Zhi Wei Xu, Torbjörn E. M. Nordling
Jun 10, 2026cs.RO

Improving Human Diving Endurance with a Field-Deployable, Untethered Exoskeleton

Human endurance in underwater locomotion is fundamentally restricted by high energetic demands to overcome drag and the finite supply of self-contained breathing gas. While exoskeleton technology can reduce the metabolic cost of humans in terrestrial locomotion, its potential to enhance human endurance during underwater diving remains entirely unexplored. Here, we present DiveMate, a field-deployable, untethered exoskeleton designed to improve human diving endurance via adaptive kick assistance in real-world underwater environments. During naturalistic diving, DiveMate increases the travel distance using a given energy (breathing gas) by 42.9% and extends dive duration by 54.9% through reducing gas consumption rate. Marked reductions in muscle activation indicate a decrease in physiological exertion, with the net gas consumption rate decreasing by 47.0%. Kinematic characteristics and regularity improvements further underpin efficient energy economy. These results suggest that applying exoskeleton assistance is beneficial for improving human diving endurance and augmenting their ability to explore the aquatic world. This study extends the application frontier of exoskeletons and provides a potential reference for the design and assessment of future underwater assistive devices.
Zhihao Zhou, Zhenmeng Ju, Rui Yang +8
Jun 9, 2026eess.SP

DMT: Demographic Conditioning, Morphology-Enhanced Transformer for Cuffless Blood Pressure Estimation from PPG Signals

Blood pressure (BP) is a key marker for cardiovascular risk assessment and therapeutic decision-making, and Photoplethysmography (PPG) enables low-cost, wearable-friendly cuffless BP estimation. However, even with recent progress, many PPG-based models are trained with BP regression alone and may rely on amplitude-dominated shortcuts. In addition, demographic covariates that systematically modulate vascular compliance are often incorporated only via late fusion, limiting subject-specific representation learning. We propose a Transformer-based network for cuffless BP estimation from PPG signal, leveraging self-attention to capture long-range dependencies across multiple cardiac cycles. To account for subject-specific vascular differences, the model is conditioned on demographics via FiLM-style feature modulation applied through the attention and feed-forward sublayers of Transformer blocks. In addition, we add an auxiliary morphology head to guide the model to attend to BP-relevant waveform morphology associated with arterial stiffness and wave reflection. Under calibration-based evaluation protocols on the large-scale PulseDB dataset, the proposed method achieves MAE of 4.56 mmHg for systolic BP and 2.62 mmHg for diastolic BP, reducing errors by 47% and 50% compared with prior demographic-enhanced PPG baselines. The resulting lightweight, single-sensor model supports scalable and clinically grounded cuffless BP estimation in calibration-enabled deployment settings.
Yidan Shen, Neville Mathew, Maham Rahimi +4
Jun 8, 2026cs.AI

Next-Token Prediction Learns Generalisable Representations of Sleep Physiology

Foundation models offer a promising route to compress multi-modal physiological signals into compact representations of human health, with broad applications across sleep medicine, cardiology, neurology and other healthcare domains. Existing models have typically been trained with masked-reconstruction or contrastive objectives. However, masked reconstruction may be poorly suited to the stochastic nature of these signals, while contrastive approaches rely on positive-pair definitions despite the semantic invariances of physiological signals being poorly understood. In this work, we show that next-token prediction is a simple and scalable alternative. We develop Hypnos, a multi-modal sleep foundation model trained using eight different sensing modalities (e.g. EEG, ECG, respiratory signals) drawn from over 20,000 overnight polysomnography recordings. We tokenize each modality into streams of discrete tokens using residual vector quantization, then train a large auto-regressive RQ-Transformer to jointly predict the next token across all modalities in parallel. After training, Hypnos can be applied to continuous streams of sensor data from any subset of supported modalities, generating embeddings for downstream tasks. Across a range of benchmarks, Hypnos significantly outperforms existing foundation models. In sleep stage classification, we match the performance of strong supervised baselines on held-out test sets whilst using 100×100\times less labelled data. Hypnos even generalises to daytime physiology, surpassing a dedicated ECG foundation model at detecting atrial fibrillation. Our results demonstrate that next-token prediction is a strong self-supervised objective for representation learning from multi-modal physiological signals.
Jonathan F. Carter, Lionel Tarassenko
Jun 7, 2026cs.LG

A spectral audit framework reveals task-dependent aperiodic reliance across EEG and ECG deep learning

Deep learning on physiological time series is interpreted through domain-specific features -- oscillatory rhythms in EEG, morphological complexes in ECG -- yet these signals sit atop a broadband aperiodic 1/f-like envelope that covaries with arousal, age, and pathology. We introduce a spectral audit framework combining aperiodic/periodic decomposition, phase-preserving Fourier interventions, sham controls, and simulation validation. Aperiodic reliance was task-dependent and architecture-general: across six neural architectures, flattening drops exceeded 0.42 balanced-accuracy points for sleep-wake classification, reached 0.07-0.13 for clinical abnormality detection, and remained minimal for motor imagery. Six of seven EEG foundation models showed FDR-significant aperiodic reliance on clinical EEG; age/sex and recording-era controls reduced but did not eliminate the effect. Applying the audit to PTB-XL ECG revealed neural drops of 0.32--0.36 persisting after demographic matching, confirming this confound class extends beyond EEG. Aperiodic controls should become standard for interpretable physiological time-series deep learning.
Jasmeet Singh Bindra, Siddharth Panwar
Jun 7, 2026cs.IT

The Bioelectrical Information Theory: Investigating the theoretical compression limit of bioelectrical signals under artificial intelligence

Bioelectrical signals are increasingly acquired at scales that challenge the bandwidth of brain-computer interfaces. However, their compression is still often framed as a problem of waveform preservation, limited by the entropy of the raw signal. Here we propose an information-theoretic framework in which the effective information of bioelectrical data is determined not only by signal fidelity, but also by physiological structure, model capacity and downstream task requirements. We formulate bioelectrical compression as a three-level hierarchy. At the signal level, noise is reduced to the information they carry about latent physiological sources. At the physiological level, parametric encoders map purified signals into compact, structured and quantized representations. At the semantic level, task-irrelevant information is discarded, while deep learning models exploit causal dependencies to replace marginal entropy with conditional entropy. This perspective reframes the compression limit of bioelectrical signals as a model- and task-conditioned quantity rather than a fixed property of the waveform. As increasingly expressive models become integrated with neural and physiological interfaces, bioelectrical compression may shift from transmitting signals to transmitting only the residual information required for task-level interpretation.
Jiawen Zou, Bo Yan
Jun 5, 2026cs.CV

OpenGlass: Ultra-Low-Power On-Device AI Eyewear with Event-based Vision

Smart eyewear enables unobtrusive, context-aware interaction through multimodal sensors and on-device intelligence, but is severely limited by power, memory, and compute constraints in a compact form factor. Open-hardware platforms supporting event-based vision and embedded ML at this scale are rare. This work introduces an open-source smart glasses platform for rapid prototyping of novel sensors and algorithms. Its modular design uses a flexible FPC interposer to support both event-based and frame-based cameras without full PCB redesign. A hardware-software co-designed power management system combines a configurable PMIC with event-driven wake-up via an nRF5340 coordinator, keeping the GAP9 RISC-V SoC powered down between inferences. The prototype achieves up to 11.5 hours of continuous on-device ML from a 200 mAh battery. As a demonstration, an egocentric hand gesture recognition pipeline was evaluated on the LynX dataset using polarity-separated event histograms from a Prophesee GENX320 camera. R(2+1)D achieved the best cross-subject accuracy of 83.94% (macro F1 = 0.781) under leave-two-subjects-out validation, with 78.3 ms end-to-end inference latency on the GAP9. Temporal augmentation and removal of ambiguous classes provided the largest gains (+8.9 pp). All hardware designs, firmware, and models are released open source.
Pietro Bonazzi, Julian Moosmann, Ahmet Celik +2
Jun 5, 2026cs.LG

A robust PPG foundation model using multimodal physiological supervision

Photoplethysmography (PPG), a non-invasive measure of changes in blood volume, is widely used in both wearable devices and clinical settings. Recent PPG foundation models either use open-source ICU datasets with pretraining paradigms that require curated data and thus complicate generalization to field-like data, or use closed-source field-like PPG data. In contrast, we propose a PPG foundation model that does not require high-quality or field-like pretraining data, and instead leverages accompanying electrocardiogram and respiratory signals in ICU datasets to select contrastive samples during pretraining. Our approach allows the model to retain and learn from noisy PPG segments, improving robustness at inference. Our model, pretrained on 3x fewer subjects than existing state-of-the-art approaches, achieves performance improvements on 14 out of 15 diverse downstream tasks, including field-like daily activity and heart rate prediction. Our results demonstrate that multimodal supervision can integrate complementary physiological information to improve the robustness of PPG foundation models and enhance their generalization to consumer-grade data.
Eloy Geenjaar, Vince Calhoun, Scott Daly +4
Jun 4, 2026cs.LG

PAMF: Prior-Aware Multimodal Fusion for Incomplete Time Series Data

In healthcare, multimodal time series tasks often operate on incomplete observations in practice, for example when ECG segments are lost because electrodes detach or an entire respiratory channel is unavailable during overnight monitoring. Such missingness typically appears in two structurally distinct patterns: within-modality missing, where values are absent within an otherwise observed modality, and modality-level missing, where an entire modality is unavailable. Existing methods typically represent unobserved data implicitly through masks or missing embeddings, without learning instance-specific missing information, and most are designed for only one missingness pattern. A natural approach is to explicitly estimate the missing data; however, existing imputation methods treat missingness uniformly despite their different structural priors, and the imputation process is often isolated from downstream tasks, preventing downstream tasks from guiding imputation toward more informative representations. To address these limitations, we present PAMF, a multimodal time-series framework that explicitly handles different missingness patterns while coupling imputation with downstream prediction through prior-aware flow matching and weight sharing. Specifically, the method initializes the flow-matching source state with type-specific priors to distinguish two missing types. It further connects imputation and classification through architecturally matched encoders with weight sharing, transferring task-relevant representations into the imputation process. Experiments on multiple multimodal healthcare time-series benchmarks show that the proposed method achieves the strongest overall downstream performance across diverse datasets and missing settings compared with existing baselines.
Ziwen Kan, Wugeng Zheng, Tianlong Chen +1
Jun 3, 2026cs.RO

OLIVE: Online Low-Rank Incremental Learning for Efficient Adaptive Exoskeletons

Wearable exoskeleton systems hold promise for restoring mobility in individuals with physical impairments, yet most existing controllers rely on static gait policies that lack the ability to adapt to dynamic real-world environments or individual user characteristics. We present \olive (\underline{O}nline \underline{L}ow-rank \underline{I}ncremental Learning for Efficient Adapti\underline{ve} Exoskeletons), a parameter-efficient online adaptation framework that continuously personalizes exoskeleton control during deployment. \olive decomposes the adaptive component of the control policy into a low-rank residual form~\dW=\At\Bt\dW = \At\Bt^\top with rank~r!!min(d,k)r!\ll!\min(d,k), reducing online update cost from O(dk)\mathcal{O}(dk) to O(r(d+k))\mathcal{O}(r(d{+}k)) while preserving the stability of a pretrained base controller~\Wz\Wz. Parameters are updated via a reward-shaped policy gradient driven purely by on-body sensor feedback (EMG, IMU, vibration), eliminating dependence on offline reference trajectories. A gating mechanism modulates the strength of personalization based on contextual state, and a dynamic rank scheduler adapts the update dimensionality to terrain complexity -- allocating minimal capacity on simple flat terrain and expanding to higher-rank updates on demanding uneven surfaces -- enabling robust performance across diverse activities: flat walking, stair navigation, slopes, and uneven terrain. Experiments on the wearable platform demonstrate that \olive achieves +13, +22, and +15 percentage-point improvements in gait smoothness, effort reduction, and motion stability over the strongest baseline, converging within \sim1{,}800 walking steps at 7.4,ms end-to-end latency. Our code implementation is available at https://github.com/FastLM/OLIVE.
Dong Liu, Yanxuan Yu, Ben Lengerich +2
Jun 2, 2026cs.CV

Spatial Artifact Coherence Determines Codec Robustness in Patch-Based rPPG

Remote photoplethysmography (rPPG) achieves low heart-rate error on uncompressed benchmarks yet is deployed over compressed video channels in telehealth, neonatal ICU, and driver fatigue applications. No prior work identifies the physical quantity determining when spatial decomposition outperforms global-projection methods under codec compression. We propose Spatial Artifact Coherence (SAC), defined as the ratio of off-diagonal to diagonal energy in the 4x4 inter-patch Green-channel covariance matrix (bandpass 0.75-2.5 Hz), and the PatchPCA algorithm family (four codec-aware rPPG algorithms). We evaluate 280 subjects across three public datasets, 11 codec degradation variants (MPEG-4, H.265, H.264, JPEG, chroma subsampling), and 13 algorithms via Wilcoxon tests (BH-FDR, q < 0.05, 904 tests). SAC explains 93.8% of between-variant variance in PCA advantage (r = +0.969), with zero overlap between codec families: non-MPEG-4 variants cluster at SAC 0.10-0.18 with 84-90% PCA win rates, while MPEG-4 variants cluster at SAC 0.48-0.59 with 61% win rate and a 5.8x reduction in mean improvement. Within subjects, 78% confirm the expected pattern (p < 10^-22, dz = 0.73). Within-variant subject-level SAC correlation is r = +0.099, confirming SAC classifies codec families rather than predicting individual outcomes. MPEG-4's effect is structural (macroblock DCT geometry, not noise amplitude), governed by source codec state, not resolution. P-Hybrid is identified as the most deployment-robust algorithm. Two necessary operating conditions for PatchPCA advantage are established: SAC < 0.30 and low-to-moderate motion, directly ruling out raw-to-MPEG-4 transcoding pipelines. SAC provides a physically grounded metric for codec-aware rPPG algorithm selection in clinical remote monitoring systems.
Achraf Ben Ahmed
Jun 2, 2026cs.CV

Template Collapse and Information-Theoretic Limits in Camera rPPG Pulse Morphology Restoration

Objective: Consumer face camera remote photoplethysmography (rPPG) enables passive cardiovascular monitoring, but whether single-cycle waveform morphology encoding arterial stiffness biomarkers is recoverable from this measurement has not been characterised. Methods: We evaluated 16 architectures spanning six families on 153 subjects across three datasets, introducing cross-subject Pearson r to distinguish subject-specific recovery from template collapse. Results: No architecture recovered subject-specific morphology (cross-subject r range 0.773--0.9999; ground-truth ceiling 0.601). Supervised Contrastive (SupCon) converged to log N = 4.844, constituting the strongest available empirical evidence that no discriminative morphological structure is extractable from single-cycle rPPG by the encoder families tested. The VAE decoder restores population-level harmonic content absent from the rPPG input (H2/H1: 0.310 output vs. 0.275 input), generalising zero-shot to UBFC (r = +0.708); a directional hallucination gap (p = 0.150) suggests partial signal reading. Anti-collapse objectives fail when input carries no discriminative structure. Significance: Consumer cameras cannot encode individual arterial morphology; cross-subject r is a necessary collapse diagnostic for waveform reconstruction benchmarks.
Achraf Ben Ahmed
Jun 2, 2026cs.CV

AmbientEye: A Dataset for Pupil Segmentation under Natural Ambient Infrared Illumination

Eye tracking is essential for smart glasses, as it provides insight into user attention for ambient intelligence applications. However, most existing eye-tracking systems rely on active infrared (IR) illumination, creating practical barriers to all-day outdoor use due to power consumption. In this paper, we investigate whether passive IR cameras alone, without any active IR light source, can enable reliable pupil detection in unconstrained outdoor environments, where ambient sunlight serves as the sole illumination source. To support this investigation, we introduce AmbientEye, a large-scale dataset of 2,606,225 eye images collected from 35 participants from 19 countries. It is captured outdoors under natural sunlight with two off-axis camera configurations and two sun-orientation conditions. We provide high-quality pupil annotation through SAM2 automatic segmentation, followed by refinement by human annotators. We benchmark a state-of-the-art pupil segmentation algorithm on our dataset and compare its performance with that on existing datasets under controlled IR illumination. Results reveal a substantial drop in pupil segmentation performance from 0.928 on controlled IR datasets to 0.767 on AmbientEye. This performance gap highlights the challenge of the ambient-light setting. This positions AmbientEye as a first benchmark for an unexplored and highly practical eye-tracking scenario.
Mingyu Han, Hyunyoung Han, Nitheekulawatn Thommakoon +4
Jun 2, 2026cs.CV

FCUS-rPPG: A Fast-Converging Unsupervised Framework for Remote Photoplethysmography via Gradient Oscillation Suppression

Remote photoplethysmography (rPPG) enables non-contact extraction of blood volume pulse (BVP) signals using consumer-grade cameras. Recent unsupervised rPPG methods learn BVP representations without requiring ground-truth physiological annotations, yet their optimization is often hindered by noisy and unstable gradients, resulting in slow convergence and limited cross-domain generalization. In this paper, we propose FCUS-rPPG, a fast-converging unsupervised rPPG framework with strong generalization capability. Motivated by the observation that BVP representations exhibit both multi-spectral covariation and low-dimensional manifold structure, we design a spectrally shared backbone that facilitates BVP feature disentanglement while improving optimization efficiency. To jointly enhance convergence stability and generalization performance, we further develop a unified optimization framework operating at the gradient, loss-landscape, and feature-representation levels. Specifically, a post-verification masking mechanism filters out misleading gradients according to the weak-amplitude physiological prior of BVP signals; a perturbation-based loss landscape smoothing strategy steers optimization toward more generalizable flat minima; and a noise-aware null-space regularization constrains feature updates to the orthogonal complement of the noise subspace, thereby mitigating noise-induced representation drift. Extensive experiments on five datasets demonstrate that FCUS-rPPG requires only one training epoch, whereas existing methods typically require tens to hundreds of epochs. Notably, FCUS-rPPG consistently achieves state-of-the-art (SOTA) performance in cross-dataset evaluations. This study provides an efficient and robust solution to the real-world deployment of unsupervised rPPG. The source code will be publicly available at https://github.com/JiaJieLee/FCUS-rPPG.
Jiajie Li, Yu Liu, Rencheng Song +2
Jun 1, 2026cs.RO

Impact of a Soft Wearable Back-Support Device on Postural Stability during Trip-Like Perturbations

The effectiveness of a soft wearable back-support device in enhancing postural stability was investigated under trip-like perturbations using two experimental paradigms: perturbed standing and perturbed walking. Healthy subjects completed trials under three different back-support conditions: no device, device worn with low stiffness, and device activated with high stiffness. Whole-body stability was quantified using the minimum Margin of Stability (MOS) at the point of maximal instability. Results demonstrated increased MOS during device use, indicating enhanced postural stability. In standing, MOS increased significantly with device stiffness, whereas in walking, both device conditions improved MOS relative to no device but did not differ significantly from each other. These findings highlight the potential of soft wearable back-support devices with adjustable stiffness to improve reactive balance control against external perturbations, with important implications for fall prevention. Future research should explore personalized stiffness optimization and evaluate efficacy in populations at elevated risk of falls.
Yuanhao Chen, Rohan Khatavkar, Soubhagya Nayak +2
Jun 1, 2026eess.SP

Diffusion-Based Heart Sound Generation: Evaluation with Physiological Signal Metrics, Classifiers, and Expert Listening

Publicly available phonocardiogram (PCG) datasets remain limited in size and pathological diversity, constraining both auscultation training and the generalisation of automated heart-sound classifiers. A class-conditional diffusion model for PCG generation is developed in the log-mel domain and synthetic fidelity is assessed using complementary (i) physiology-inspired plausibility metrics, (ii) downstream label-consistency evaluation, and (iii) expert listening. Experiments use the Phy-sioNet/Computing in Cardiology Challenge 2016 dataset (3240 recordings) with recording-level splits. After preprocessing and quality control, 16,749 non-overlapping 4 s clips are mapped to a normalised 1 x 128 x 128 log-mel representation to train a conditional 2D U-Net denoiser with classifier-free guidance. Signal-level plausibility is quantified on reconstructed waveforms using three lightweight metrics: an envelope-autocorrelation rhythm score, an amplitude-based explosion score, and the dominant cycle lag. Synthetic clips preserve similar dominant cycle durations but exhibit reduced envelope periodicity and increased transient burstiness relative to real clips. For downstream evaluation, a ResNet-50 classifier achieves 92.24% accuracy on the held-out real test set and 82.8% accuracy on class-balanced synthetic batches, indicating that generated signals retain discriminative structure relevant to normal/abnormal classification. In a pilot expert listening study (60 clips, two clinicians), most synthetic clips are judged as heart-sound-like, while abnormality sensitivity is low for both real and synthetic 4 s excerpts. Overall, the results provide a practical baseline for diffusion-based PCG generation while highlighting remaining challenges in retaining abnormal acoustic cues and reducing reconstruction-induced artefacts.
Xinqi Bao, Jia Bi, Xin Chen +2
Jun 1, 2026cs.LG

ArrythML: An Autoencoder-Based TinyML Approach for On-Device Arrhythmia Detection on Resource-Constrained Embedded Systems

Our work presents a method for ECG segmentation and arrhythmia detection using Tiny Machine Learning (TinyML) models for real-time, on-device inference on resource-constrained embedded systems. We develop INT8 quantized autoencoder-based TinyML models with minimal layers and parameters for embedded deployment. These models are evaluated using a custom dataset derived from the MIT-BIH Arrhythmia Database and validated in both PC-based simulations and on-device environments. For the evaluations, over 95,000 ECG segments are processed on an ESP32-S3 microcontroller running the TensorFlow Lite Micro runtime. Post-evaluation, detailed analysis, including annotation-wise and record-wise failure analysis, is conducted to characterize model behavior across diverse ECG morphologies and rhythm patterns and to explain missed detections. In several cases, apparent misclassifications may correspond to early or subtle anomaly patterns labeled as normal in the reference annotations, highlighting the model's sensitivity. A refined evaluation by filtering out ambiguous cases in the dataset shows that the best-performing DNN-based autoencoder achieves a recall of 84%, an F1-score of 79%, a model size of approximately 180 KB, and an inference latency of 9 ms on-device. These results demonstrate the feasibility of low-power, privacy-preserving embedded wearable systems capable of performing accurate arrhythmia detection entirely on-device.
Nagarajan S, Kurian Polachan
May 31, 2026cs.HC

pcbGPT: Automatic PCB Schematic Synthesis from Natural Language Requirements

Translating natural-language hardware requirements into correct printed circuit board (PCB) schematics remains difficult in embedded, IoT, and wearable development. Designers must choose compatible components, interpret datasheets, add support circuitry, and expose correct interfaces before layout and prototyping can begin, while many such circuits cannot be validated through straightforward simulation. We present pcbGPT, a grounded system for generating editable KiCad schematics from natural-language specifications. pcbGPT represents circuits in a Python DSL and combines tool-augmented synthesis with component-library search, datasheet-grounded design knowledge, execution-based checking, structural and semantic validation, and an interactive web workflow that supports iterative refinement and synchronization with KiCad projects. We evaluate the system on 20 embedded schematic-generation tasks with reference implementations, required components, and interface constraints that enable automatic comparison. The best model reaches overall pass@1 of 0.90 and pass@5 of 1.00; pass@1 is 1.00 on basic and easy tasks, 0.91 on medium tasks, and 0.72 on hard tasks. These results, together with failure analysis, show that pcbGPT can already generate useful, reviewable first-draft schematics for early prototyping, but is not yet reliable enough to replace expert review.
Tobias King, Steven Kehrberg, Michael Beigl +1
May 30, 2026cs.CV

SuperMemory-VQA: An Egocentric Visual Question-Answering Benchmark for Long-Horizon Memory

AI glasses present a compelling platform for AI agents to serve as personalized memory assistants. To be genuinely useful, such systems must move beyond short-term video comprehension and address memory gaps that humans experience for practical, personal, or social purposes over longitudinal egocentric video streams. However, existing egocentric datasets predominantly focus on action recognition or generic QAs from short clips, measuring perceptual capabilities rather than realistic human memory needs. We introduce SuperMemory-VQA, an egocentric visual question answering (VQA) dataset for evaluating AI assistants on practical, long-horizon memory tasks. It contains 52.9 hours of everyday activities recorded with AI glasses, including synchronized RGB video, audio transcription, eye gaze, IMU, and SLAM trajectories. Through a human-verified annotation pipeline, we construct grounded 4,853 question-answer pairs that span object and location memory, intent recall, visual scene recall, timeline reconstruction, conversational memory, and in-context retrieval. Each question is posed as multiple-choice with an explicit "unanswerable" option to test hallucination robustness. Benchmarking leading agentic frameworks and LLM backbones reveals that existing systems remain far from reliable on real-world memory tasks, highlighting the need for new architectures for grounded AI memory that can answer only when evidence is sufficient. A participant survey further supports that our questions are realistic, useful, and aligned with everyday memory needs.
Samiul Alam, Shakhrul Iman Siam, Michael J. Proulx +4
May 30, 2026cs.LG

A multimodal dataset of photoplethysmography and continuous behavioral responses to ASMR and nature videos

Autonomous Sensory Meridian Response (ASMR) is a somatosensory phenomenon characterized by pleasant tingling sensations and cardiovascular slowing. However, ASMR research has been hindered by a dearth of standardized, open-access multimodal datasets. To address this limitation, we present REST-ASMR (Response to Environmental & Sensory Triggers), a synchronized multimodal dataset designed to capture behavioral reports and physiological dynamics during ASMR, with nature-relaxation videos as control stimuli. The dataset includes high-resolution photoplethysmography (PPG), time-aligned audiovisual stimuli, and continuous subjective annotations from 34 participants. Technical validation showed high stimulus efficacy (97% responder rate), significant stimulus-specific inter-subject agreement (p < 0.05), and a robust PPG-derived ASMR-specific cardiovascular deceleration. Additionally, a Bidirectional Long-Short Term Memory model successfully predicted subjective ASMR tingle states, achieving video-level ASMR vs. Nature classification with perfect accuracy and a frame-level global mean accuracy of 75.51%, macro F1-score of 71.86%, and 100% Nature-baseline specificity, under a strict, leakage-free subject-video double-independent 4-fold cross-validation. REST-ASMR constitutes a dense temporal foundation for affective computing, multimodal research, and the development of personalized models of relaxation-related responses.
Tushar Das, Daigo Hozaki, Koushlendra Kumar Singh +1
May 29, 2026cs.LG

Longitudinal Multimodal Sensing of Physical Activity and Well-Being in Older Adults

Wearable and mobile sensing technologies enable continuous monitoring of human behavior and health in real-world settings. However, predictive modeling in longitudinal multimodal data remains challenging, particularly when targeting complex or clinically derived outcomes. In this work, we present a longitudinal multimodal study of 66 older adults conducted in real-world conditions and combining wearable sensing, behavioral monitoring, and clinical assessments. This setting provides a rare opportunity to study an underrepresented population in long-term, into-the-wild conditions. Building on this dataset, we investigate how the alignment between sensed signals and target variables affects predictive performance across health-related tasks. We design a unified evaluation framework spanning tasks with increasing levels of observability, including Activity Levels prediction, Sleep Duration estimation, and Sleep Apnea Severity classification. Our results reveal a clear gradient of predictability: highly observable behavioral targets achieve robust performance (macro-F1 65%), while more abstract outcomes remain challenging despite consistent improvements over baseline models. Moreover, through explainability analysis, we show that historical features consistently emerge as the most informative predictors, highlighting the central role of longitudinal information.
Flavio Di Martino, Mattia G. Campana, Marcello Magno +2
May 29, 2026cs.HC

UF-AMA: A unified framework for cross-domain emotion recognition via adaptive multimodal alignment

In recent years, emotion recognition based on physiological signals such as electroencephalogram (EEG) has gained considerable attention, as internal physiological data offer greater objectivity and reliability compared to external behavioral data like facial expressions. However, due to distribution shifts caused by individual and contextual differences, along with variations in sample quality across modalities, constructing a cross-domain multimodal emotion recognition model with high generalization and robustness remains a key challenge. In this study, we propose a Unified Framework with Adaptive Multimodal Alignment (UF-AMA) to address cross-subject and cross-session emotion recognition using multimodal physiological signals. First, we construct a cross-modal feature fusion network comprising Transformer encoders and multi-head cross-attention modules, enabling the deep integration of EEG signals and eye-tracking data. Subsequently, we introduce a confidence-aware screening mechanism that dynamically assesses the predictive reliability of each modality branch on target domain samples, partitions samples into different quality subsets, and accordingly applies global consistency alignment and cross-modal distillation. Finally, we propose a multi-level domain adaptation framework that jointly optimizes the marginal and conditional distributions of both local modality-specific and global fusion features, thereby reducing cross-domain distribution shifts at multiple granularities. Extensive experiments on the SEED and SEED-IV datasets demonstrate that UF-AMA achieves state-of-the-art (SOTA) performance in both cross-subject and cross-session tasks. The source code is available at: https://github.com/BetterCoderLab/UF-AMA.
Zheng Wang, Shuo Wang, Junhong Wang
May 29, 2026cs.LG

DEM: A Distilled Explanation Model for Interpretable Anomaly Detection in Physiological Sensor Networks

Anomaly detection in physiological sensor data from Wireless Body Area Networks (WBANs) can be caused by sensor faults, network disruptions, or missing data, leading to false alarms. Hence, it demands both high predictive accuracy and clinically interpretable explanations. Existing approaches rely either on black-box models that achieve strong performance but offer no transparency, or on post-prediction explanation methods such as SHAP and LIME. In this paper, we propose the Distilled Explanation Model (DEM), a three-stage glass-box framework that distills the non-linear knowledge of a gradient boosting expert into an interpretable decision tree operating on residuals relative to a linear baseline, so that the explanation is not an approximation but the prediction itself. DEM introduces a novel distillation fidelity metric that quantifies how faithfully the explanation tree captures the expert model's non-linear contribution, providing a principled measure of explanation trustworthiness absent from prior interpretable models. Evaluated across four physiological datasets, including MIMIC-IV, WESAD, eICU, and an in-house SmartNet WBAN corpus, DEM achieves an AUC of 0.9964 on clinical contextual anomaly detection and 0.9047 on wearable stress detection while producing human-readable if-then rules at a controllable depth. Inference requires 0.17ms per 1000 samples, rendering DEM 1235x faster than SHAP-based post-hoc explanation and suitable for real-time physiological monitoring. Ablation studies confirm that the XGBoost distillation step provides measurable gains over naive residual fitting, and depth-sensitivity analysis demonstrates an explicit, user-controlled accuracy-interpretability trade-off unique to DEM among existing intrinsically interpretable models.
Jyotirmoy Singh, Anushka Roy, Shreea Bose +1
May 29, 2026cs.LG

GlucoFM: A Dual-Stream Foundation Model for Continuous Glucose Monitoring

Continuous glucose monitoring (CGM) provides a dense view of daily metabolic physiology, yet existing generic time-series and CGM-specific foundation models often encode glucose traces as entangled single-stream sequences, leaving the distinct temporal structure of glycemic dynamics only implicitly modeled. We present GlucoFM, a lightweight CGM foundation model that aligns irregular recordings to a 24-hour chronological grid, preserves observation masks, and decomposes glucose dynamics into slow physiological state and transient event streams, capturing low-frequency glycemic baselines and short-term deviations that may reflect acute physiological responses or sensor artifacts. GlucoFM is pretrained on 109,066 hours of unlabeled CGM recordings from 477 subjects with two complementary objectives: masked contextual latent prediction over fused daily representations and temporal dynamics prediction over state and event streams. Across four diverse cohorts and seven clinical prediction tasks, GlucoFM achieves the strongest subject-disjoint linear-probing performance among evaluated baselines, improving average PR-AUC by 4.1 points over the best CGM-specific foundation model. Its gains are most pronounced on core metabolic outcomes, leading PR-AUC on all diabetes-risk and ββ-cell dysfunction tasks and on 3 of 4 insulin-resistance tasks. GlucoFM also achieves the best overall cross-dataset transfer performance and strong few-shot adaptation among evaluated methods, and consistent gains when aggregating multiple days for subject-level prediction, highlighting physiology-aware decomposition as an effective inductive bias for transferable CGM representation learning.
Zechen Li, Keerthana Natarajan, Weizhi Zhang +11
May 29, 2026cs.LG

Adaptive data selection improves wearable prediction under low baseline performance

Adaptive sensing strategies that selectively sample data are increasingly used in wearable health systems to improve prediction performance under limited data budgets, yet their benefits across individuals remain poorly understood. Here, we evaluate adaptive selection of time windows for model training under fixed measurement budgets across multiple sensing modalities, including heart rate, activity, and ecological momentary assessment (EMA), in a longitudinal wearable dataset. We quantify performance gains relative to random sampling using both area under the receiver operating characteristic curve (AUROC) and F1 score. Adaptive strategies yield substantial improvements in AUROC for participants with low baseline performance (with gains up to 0.7), while offering limited or negative gains for participants with strong baselines. Across modalities, adaptive gain is strongly inversely correlated with baseline performance (Pearson r = -0.67; Spearman p = -0.62). At the participant level, most individuals benefit in AUROC (60-80% across modalities), although improvements in F1 are smaller and less consistent. These findings show that adaptive sensing is not uniformly beneficial, but instead provides the greatest value in underperforming settings. Our results support selective deployment strategies that tailor adaptive sensing based on baseline performance to improve efficiency in wearable health monitoring.
Ali Kargarandehkordi
May 28, 2026eess.AS

Mitigating Stethoscope-Induced Shortcuts in Respiratory Sound Classification under Federated Domain Generalization with Causality-Inspired Interventions

AI-driven respiratory sound classification (RSC) is promising for automated pulmonary disease detection, yet multi-site deployment is hindered by inter-stethoscope variability. We introduce a federated domain generalization (FedDG) formulation for RSC in which clients hold recordings from different stethoscopes and the model is evaluated on an unseen device. Our empirical analysis shows that stethoscope-induced style and disease-relevant content are partially entangled, making deterministic style removal unreliable. In response, we propose BTS-CAFE, a framework combining (i) causality-inspired device-style interventions with constraints designed to limit content distortion, (ii) counterfactual metadata augmentation to relieve device and demographic shortcuts, and (iii) gradient alignment to promote device-invariant decision boundaries across clients. Built on BTS with CLAP, a multimodal language-audio pretraining model, BTS-CAFE improves the out-of-distribution ICBHI Score by 3.69 points on average over five held-out devices relative to its backbone, and outperforms conventional data augmentation and federated learning baselines in simulated device leave-out evaluations on the ICBHI and SPRSound datasets.
Heejoon Koo, Yoon Tae Kim, Miika Toikkanen +1
May 28, 2026cs.RO

Joint Angle Estimation with Customized Wristband Based on Online Incremental Learning

Intelligent wearable technology plays an increasingly important role in human-computer interaction, motion, and health monitoring. To ensure comfort and practicality of use, one common form for motion monitoring is to utilize soft wearable sensors. However, many research applications regarding wearable sensors are simplistic and difficult to adapt to different situations. This study proposes a system for estimating the angle of the wrist joint using a customized wristband based on an online incremental learning approach. It is a two-stage estimation method: the first stage updates the model based on the wearer's wrist movement characteristics using online learning, integrating real-time data from an IMU as ground truth. The second stage utilizes the updated model for estimation of wrist joint angle solely with the wristband. In other words, model training is completed during data acquisition, allowing the trained model to be used for subsequent angle estimation. This method offers advantages in adapting to data drift caused by variations in different testing configurations, such as the left and right wrists of the same subject, deviations in the wearing position on the same wrist, and even differences among various subjects. The results indicate that the sensors exhibit good performance under strain variations, and the wrist joint trajectory estimation of the proposed system has an approximate error of 15 degree in different scenarios.
Shuo Wang, Xiaobin Chen, Xiaoming Tao
May 28, 2026cs.AI

VitalAgent: A Tool-Augmented Agent for Reactive and Proactive Physiological Monitoring over Wearable Health Data

Wearable devices enable continuous monitoring of physiological signals such as ECG and PPG, but existing mHealth systems are largely limited to task-specific prediction pipelines or reactive question answering over static summaries. They lack the ability to support temporal reasoning, persistent physiological context, and proactive monitoring over long-term signal streams. We propose VitalAgent, a tool-augmented agentic framework for ECG/PPG-based mHealth that supports both reactive question answering and proactive monitoring. VitalAgent is built on a longitudinal physiological memory and a tool-augmented reasoning interface that enables dynamic computation over raw signals. We further introduce VitalBench, a longitudinal physiological monitoring benchmark dataset comprising 1,862 QA pairs for reactive question answering and 90.2 hours of continuous ECG/PPG recordings for proactive monitoring, covering cardiac, physical activity, and stress-related tasks. Experiments demonstrate that VitalAgent achieves over 25% improvement over prompt-based and ReAct baselines in reactive evaluation and supports proactive alert monitoring over long-term physiological signals, highlighting the importance of dynamic tool use and long-term physiological monitoring.
Di Zhu, Yu Yvonne Wu, Hong Jia +3
May 28, 2026cs.LG

SigmaMedStat: Temporal Signal Modeling for ICU False Alarm Reduction

Alarm fatigue in intensive care units (ICUs) is a well documented patient safety crisis. Clinical monitors generate 350 or more alarms per patient per day, out of which 72-99% are clinically irrelevant. Staff desensitization to non-actionable alarms increases the risk of missed true emergencies. This paper presents SigmaMedStat, a machine learning system that evaluates the trustworthiness of physiological alarm signals before clinical action is taken. Four approaches were evaluated on the PhysioNet/Computing in Cardiology Challenge 2015 dataset of 498 four-channel ICU alarm recordings. Primary contribution is a temporal modeling framework that splits each 60 second recording into six consecutive 10-second chunks, and this in turn generates Continuous Wavelet Transform (CWT) scalograms per chunk, encodes each chunk with a shared EfficientNet-B0 encoder, and passes the resulting feature sequence to a two-layer Long Short-Term Memory (LSTM) network. Five-fold stratified cross-validation yields a mean AUC of 0.822 +/- 0.016 (95% CI: [0.790,0.853]), compared to 0.641 for a static EfficientNet baseline trained on the full 60-second window. Ablation studies confirm that temporal chunking and multi-channel signal fusion both contribute independently to classification performance. Per-alarm type analysis reveals that Ventricular Flutter is the most accurately classified alarm type (AUC 0.820) while Asystole remains the hardest (AUC 0.722). Error analysis identifies 65 false negatives and 85 high-confidence misclassifications as the primary failure modes. All code and results are publicly available at https://github.com/Arun-K-Ram/sigmamedstat.
Arunkumar Ramachandran
May 26, 2026cs.LG

Information-theoretic Multimodal Representation Learning for Electrocardiogram Signals

Electrocardiograms (ECGs) are widely used non-invasive measurements of cardiac activity and play a central role in clinical diagnosis. Recent multimodal approaches align ECG signals with clinical reports to incorporate diagnostic semantics, but clinical reports often fail to preserve the rich physiological structure of ECG waveforms, particularly across multiple levels of abstraction ranging from coarse diagnostic categories to fine-grained morphology. To address this limitation, we formulate ECG representation learning from an information-theoretic perspective and derive a tractable objective that jointly preserves signal structure and integrates clinical semantics. Based on this principle, we propose \textbf{MERIT} (Multimodal ECG Representation via Information Theory), a dual-branch pretraining framework combining masked ECG modeling with ECG--text contrastive alignment. Extensive experiments on PTB-XL and additional benchmarks demonstrate consistent improvements over prior methods, including gains exceeding 33% F1 on PTB-XL All and 55% F1 on SubClass classification. In zero-shot evaluation, MERIT further improves performance by up to +2.66% +2.66\% AUC and +2.11% +2.11\% F1 on PTB-XL SubClass, while also demonstrating robustness under multiple distribution-shift settings. Moreover, leveraging the learned ECG representations for ECG-conditioned clinical text generation with large language models improves text quality across several metrics, including ROUGE and METEOR. Together, these results demonstrate that MERIT learns more informative and clinically meaningful ECG representations, particularly for fine-grained clinical applications.
Phu X. Nguyen, Konstantinos Kontras, Wei Dai +5
May 26, 2026cs.RO

Inducing Calmness With Pocket-Sized Robotics: Reducing Movement and Heart Rate in Children through Hand-Held Tactile Interactions

Periods of heightened arousal or restlessness can interfere with children's ability to focus, self-regulation, and physically calm. Technologies that encourage embodied self-regulation through tactile interaction may provide a simple and accessible means of promoting calmness. This paper investigates how interaction with a pocket-sized tactile device influences physiological and behavioral markers of calmness in typically developing children. Building on prior work examining heart rate modulation, we present new findings on how tactile interaction affects full-body movement and postural stability. We employ a device that engages children through a hand-held rhythmic vibration-matching game, designed to focus attention and encourage stillness. Eighteen children participated in a within-subjects study that involved two conditions: with and without tactile interaction with a hand-held device, while having their heart rate and body movement recorded. Results show that the tactile game interaction reduced physiological arousal (heart rate decreased by 3.56 bpm, p < 0.01) and physical restlessness (overall movement decreased by 38%, p < 0.05), with attention-related body regions showing the greatest change toward stillness (45% reduction in movement). These findings demonstrate that brief tactile game-like engagement with a hand-held device can down-regulate physiological activation, promoting the calm and focused states toward sustained attention and behavior regulation.
Morten Roed Frederiksen, Kasper Støy, Maja Matarić
May 26, 2026cs.CV

Beyond Motion Primitives: Behavioral Activity Recognition from Head-Mounted IMU

AR smart glasses need continuous behavioral context to offer proactive assistance, yet their most practical always-on sensor, the head-mounted Inertial Measurement Unit (IMU), detects only motion primitives such as walking or standing. We push beyond motion primitives to behavioral-level recognition, defining five categories that balance AR application need with sensor observability. To this end, we construct a 160K-sample Ego4D dataset with a four-tier quality assurance framework spanning 8 activity scenarios, and propose HiT-HAR, a 703K-parameter hierarchical model that outperforms prior head-mounted IMU models on five-class action and eight-class scenario recognition. We further map the observability frontier of head-mounted IMU through per-class separability analysis, identifying which behavioral categories are reliably observable (Locomotion), which benefit from temporal context (Object Transfer, Task Operation), and where scenario-dependent signal overlap poses remaining challenges. Our results indicate that architectural choices exploiting temporal context and scenario structure outperform simply scaling model size. The code and dataset are publicly available at https://github.com/Harvard-AI-and-Robotics-Lab/HiT-HAR.
Chung-Ta Huang, Leopold Das, Jeffrey Zhou +10
May 25, 2026cs.LG

HRVConformer: Neonatal Hypoxic-Ischemic Encephalopathy Classification from the Heart Rate signals

This paper presents the HRVConformer, a novel deep learning architecture for the classification of hypoxic-ischemic encephalopathy (HIE) using the instantaneous heart rate (HR) signal. Unlike conventional approaches that rely on handcrafted features, HRVConformer directly processes raw HR signals in an end-to-end manner, capturing both local and long-range dependencies through a hybrid Convolution-Transformer framework. By integrating convolutional layers for local feature extraction and Transformer-based attention mechanisms for global context modelling, the architecture effectively enhances signal representation and classification performance. The model was trained using supervised learning on a large HR dataset consisting of 1,573 one-hour epochs, including 259 one-hour expert-annotated epochs and a substantial set of weakly labelled data. A 314-hour validation set provided a robust performance estimation, while an independent 215-hour dataset with expert annotations was reserved for final testing. HR signals were extracted from electrocardiogram (ECG) recordings using an improved Pan-Tompkins algorithm, which significantly enhanced both signal quality and data availability. Experimental results demonstrate that the HRVConformer achieves an AUC of 83.23% and accuracy of 74.56% on the test set. These results surpass the performance of the Transformer, ResNet50 and fully convolutional networks baselines, highlighting the advantages of integrating convolutional and Transformer-based components for HR-based HIE classification. The proposed method provides a promising step toward a more accurate and automated assessment of HIE using HR signals. The code is available at: https://github.com/syu-kylin/HRVConformer.
Shuwen Yu, William P Marnane, Geraldine B. Boylan +1
May 23, 2026cs.LG

Synheart Capacity: A Theory-Driven Physiological Representation of Cognitive Capacity Dynamics from Wearable Signals

Human cognitive performance is constrained by limited mental resources, yet continuous computational estimation of cognitive capacity dynamics remains an open challenge. We propose a theory-driven multimodal learning framework that models capacity-related cognitive state as a two-dimensional physiological representation defined by voluntary resource allocation (mental effort) and overload-related strain (stress). The proposed architecture combines dual-stream encoding of cardiac (IBI/HRV) and electrodermal (EDA) signals with late fusion and task-specific output heads that independently estimate probabilistic effort and stress states. Evaluation on the SWELL-KW dataset using strict leave-one-subject-out cross-validation demonstrates cross-individual generalization (stress: 70.0% balanced accuracy; effort: 72.2%), with significant gains from multimodal integration and theory-guided supervision. Rather than collapsing physiological dynamics into a single workload label, the proposed effort--stress state-space enables structured differentiation between distinct cognitive regimes, including productive engagement and overload-related strain. Predicted state trajectories exhibit significant demand-sensitive shifts under controlled workload manipulations, with effort and stress responding differentially across interruption and time-pressure conditions. These results suggest that physiologically grounded multidimensional state representations may provide a foundation for adaptive systems capable of continuous capacity-aware monitoring and human-centered interaction.
Yisak Debele, Henok Ademtew, Israel Goytom
May 22, 2026cs.HC

Detecting Drunk Driving Using Off-the-Shelf Smartwatches

Alcohol-impaired driving remains a major yet preventable cause of road traffic injury and death, with many drivers underestimating their level of intoxication. Compared to in-vehicle systems, mobile drunk-driving detection using consumer smartwatches offers a scalable way to trigger preventive interventions and increase awareness without additional in-vehicle hardware. We introduce a system that leverages wrist accelerometer data and heart rate variability-derived physiological signals to detect alcohol-related driving impairment. We collected data in a randomized, controlled three-arm test-track study (n=54) and trained both logistic regression models with window-aggregated features and a two-tower 1D convolutional neural network (CNN), to detect alcohol-impaired driving. The CNN achieved a participant-averaged area under the receiver operating characteristic (AUROC) of 0.88 for detecting any alcohol intoxication and 0.86 for detecting driving above the WHO-recommended limit of 0.05 g/dL. To the best of our knowledge, this is the first work to (1) demonstrate drunk-driving detection using consumer smartwatches, (2) develop and evaluate such a system in a real vehicle on a closed test track, and (3) rigorously assess generalization to unseen participants. Together, these findings highlight the potential of wearable-based sensing to support scalable, measurement-driven prevention of alcohol-related traffic harm.
Robin Deuber, Lanlan Yang, Michal Bechny +9
May 22, 2026cs.LG

Federated Learning over Human-Body Communication for On-Body Edge Intelligence: A Survey, Taxonomy, and BODYFED-HBC Scheduling Vignette

Human-body communication (HBC) is a promising physical substrate for wearable body-area networks because it can localize communication around the body and reduce the burden of conventional radio links. Federated learning (FL) is a promising learning substrate because it can reduce raw-data centralization for physiological and behavioral sensing. Yet these two literatures remain weakly connected: FL for wearables usually abstracts the communication layer, whereas HBC research usually abstracts learning and model-update traffic. This article surveys the intersection of HBC, wireless body-area networks, wearable FL, Internet-of-Bodies privacy, and edge-intelligence optimization. We propose a taxonomy that distinguishes intra-body, body-hub, cross-user, and clinical-cloud FL deployments, and we identify the open problem of body-channel-aware FL: learning protocols whose client selection, update compression, and aggregation are controlled by posture-dependent HBC links, residual energy, sensor memory, and privacy risk. To make the research agenda concrete, we introduce BODYFED-HBC as a reference architecture and provide an optimization formulation and scheduling algorithm. We further specify a reproducible simulation vignette that combines public wearable datasets with empirical body-coupled-communication signal-loss models. The article concludes with open datasets, evaluation metrics, limitations, and research directions for computer scientists working above the hardware layer.
Koffka Khan
May 22, 2026cs.CV

LQ-rPPG: A Label-Quantized Coarse-to-Fine Learning Framework for Remote Physiological Measurement

Remote photoplethysmography (rPPG) enables non-contact measurement of physiological signals from facial videos, offering strong potential for remote healthcare and daily health monitoring. Driven by this potential, various deep learning-based rPPG methods have been proposed to improve rPPG estimation. However, previous deep learning-based rPPG methods have paid little attention to the quality of training labels and their impact on model learning. Contact-based PPG signals used as training labels often contain noise and variability caused by motion artifacts, inconsistent sensor contact, and morphological distortions. Such label inconsistency can lead models to overfit to the label noise and variability and consequently degrade generalization performance. To address this issue, we propose LQ-rPPG, a label-quantized coarse-to-fine learning framework for robust rPPG estimation. LQ-rPPG consists of a label quantization module and a coarse-to-fine rPPG estimation model. The label quantization module transforms continuous PPG signals into multi-bit quantized pseudo labels with reduced noise and variability. The coarse-to-fine estimation model progressively refines rPPG signals under hierarchical supervision guided by the multi-bit pseudo labels. This design alleviates overfitting to label-specific variations and enables the model to learn structured and consistent representations. As a result, LQ-rPPG achieves robust and generalizable rPPG estimation even under challenging conditions. Experiments on multiple benchmark datasets demonstrate that LQ-rPPG achieves strong performance in both intra- and cross-dataset evaluations, while reducing parameters and multiply-accumulate operations by 88% and 29%, respectively, and increasing throughput by 191%. The code is available at https://github.com/Anonymous-repo-code/LQ-rPPG.
Jun Seong Lee, Samyeul Noh, Changki Sung +1
May 21, 2026cs.LG

CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment

Assessing cognitive load continuously and at low latency would help adaptive human-computer interaction, but it remains hard because labeled data are scarce and models generalize poorly across subjects. Recent ECG foundation models, pre-trained on millions of clinical diagnostic ECG recordings, yet they do not apply directly to wearable devices when the sensor configuration and the task both differ. We present CogAdapt, a framework that adapts a clinical ECG foundation model to wearable cognitive load assessment. CogAdapt has two parts. LeadBridge is a learnable adapter that maps 3-lead wearable signals to a 12-lead-compatible representation. ProFine is a progressive fine-tuning strategy that unfreezes encoder layers in stages while limiting representational drift in the pre-trained model. On two public datasets (CLARE and CL-Drive) under leave-one-subject-out cross-validation, CogAdapt reaches macro-F1 of 0.626 and 0.768, improving over from-scratch baselines by 11.2 and 16.1 percentage points. The results show that a clinical ECG pretraining can support subject-independent cognitive load assessment from wearable sensors.
Amir Mousavi, Erfan Nourbakhsh, Mohammad Sadegh Sirjani +5
May 21, 2026cs.AI

Towards a General Intelligence and Interface for Wearable Health Data

While ubiquitous wearable sensors capture a wealth of behavioral and physiological information, effectively transforming these signals into personalized health insights is challenging. Specifically, converting low-level sensor data into representations capable of characterizing higher-level states is difficult due to high phenotypic diversity and variation in individual baseline health, physiology, and lifestyle factors. Moreover, collecting wearable data paired with health outcome annotations is laborious and expensive, and retrospective annotation remains practically unfeasible, contributing to a scarcity of data with high-quality labels. To overcome these limitations, we propose a foundation model for wearable health that is pretrained on more than one trillion minutes of unlabeled sensor signals drawn from a large cohort of five million participants. We demonstrate that the joint scaling of model capacity and pretraining data volume leads to systematic improvements in performance, as evaluated on a diverse set of 35 health prediction tasks, spanning cardiovascular, metabolic, sleep, and mental health, as well as lifestyle choices and demographic factors. We find that this population scale representation unlocks label-efficient few-shot learning and generative capabilities for robust daily metric estimation. To further leverage this learned representation, we deploy a classroom of LLM agents to autonomously search the space of downstream predictive heads built on the model embeddings, showing broad performance improvements that increase with LLM model capacity. Finally, we show how integrating these downstream predictors into a Personal Health Agent can support model responses that are more relevant, contextually aware, and safe, and we validate this via 1,860 ratings from a cohort of clinicians.
Girish Narayanswamy, Maxwell A. Xu, A. Ali Heydari +37
May 21, 2026cs.CV

AnyMo: Geometry-Aware Setup-Agnostic Modeling of Human Motion in the Wild

As wearable and mobile devices become increasingly embedded in daily life, they offer a practical way to continuously sense human motion in the wild. But inertial signals are highly dependent on the sensing setup, including body location, mounting position, sensor orientation, device hardware, and sampling protocol. This setup dependence makes it difficult to learn motion representations that transfer across devices and datasets, and limits the broader use of wearable IMUs beyond closed-set recognition. We introduce AnyMo, a geometry-aware framework for setup-agnostic human motion modeling. AnyMo uses physics-grounded IMU simulation over dense body-surface placements to generate diverse and plausible synthetic signals, pre-trains a graph encoder from paired synthetic placement views and masked partial observations, tokenizes multi-position IMU into full-body motion tokens, and aligns these tokens with an LLM for motion-language understanding. We evaluate AnyMo on three complementary tasks: zero-shot activity recognition across 14 unseen downstream datasets, cross-modal retrieval, and wearable IMU motion captioning, where it improves average Accuracy/F1/R@2 by 11.7%/11.6%/22.6% on HAR, increases zero-shot IMU-to-text and text-to-IMU retrieval MRR by 15.9% and 28.6%, respectively, and improves zero-shot captioning BERT-F1 by 18.8%. These results support AnyMo as a generalist model for wearable motion understanding in the wild. Project page: https://baiyuchen.com/project/AnyMo.
Baiyu Chen, Zechen Li, Wilson Wongso +5
May 21, 2026eess.IV

Time-varying rPPG signal separation via block-sparse signal model

Remote photoplethysmography (rPPG) enables non-contact measurement of cardiac pulse signals by analyzing subtle color changes in facial videos. Nevertheless, extracting rPPG signals remains challenging because of their extremely weak signal strength and susceptibility to illumination noise. In this paper, we propose an rPPG signal extraction method that exploits the quasi-periodic characteristics of rPPG signals. Our approach models quasi-periodicity of the rPPG signal, which arises from the stable cardiac cycle, as a block-sparse structure in the time-frequency domain. To incorporate a block-sparse model and enable adaptive signal separation under illumination fluctuations, we construct a time-varying signal separation framework. Experiments using a public dataset demonstrate the effectiveness of our method.
Kosuke Kurihara, Yoshihiro Maeda, Daisuke Sugimura +1
May 21, 2026cs.CV

Physiology and Anatomy Aware Inverse Inference of Myocardial Infarction for Cardiac Digital Twin

Accurate localization of myocardial infarction is essential for risk stratification. While LGE-MRI remains the gold standard, it is resource-intensive. Integrating cine MRI with ECG enables a more detailed representation of infarct properties. Existing inverse MI inference methods overlook realistic scar morphology and cardiac repolarization, reducing sensitivity to subtle ECG variations and interpretability of infarct-induced electrophysiological changes. In this paper, we propose a novel framework for noninvasive MI localization using cardiac digital twins. To bridge the domain gap between simulation and reality, we introduce an anatomy-aware stochastic infarct synthesis strategy to synthesize realistic, irregular scars with border zones, mimicking ischemic transmural progression. We then construct a virtual cohort to simulate QRS-T waveforms, capturing both depolarization and repolarization dynamics. Furthermore, we design a Physiology and Anatomy Aware Network (PAA-Net) that jointly encodes 3D myocardial geometry and multi-lead ECGs to infer infarct areas with varying localizations, sizes, spatial extents, and transmuralities. Experimental results demonstrate that our framework significantly outperforms existing methods in inverse inference, achieving Dice scores of 0.7391 and 0.5503 for scar and border zone segmentation, respectively, while further enhancing the interpretability of the ECG-infarct relationship. Our code will be released upon acceptance.
Mengxiao Wang, Yilin Lyu, Julia Camps +6
May 20, 2026cs.CV

R2AoP: Reliable and Robust Angle of Progression Estimation from Intrapartum Ultrasound

Accurate estimation of the Angle of Progression (AoP) from intrapartum transperineal ultrasound is critical for objective assessment of labor progression, yet remains highly sensitive to imaging noise, boundary ambiguities, and the geometric amplification of local segmentation errors. We propose R2AoP, a reliable and robust AoP estimation framework that integrates structurally informed segmentation and confidence-guided geometric modeling to achieve stable and reproducible measurements. A three-branch local-structure-enhanced backbone improves the delineation of the pubic symphysis (PS) and fetal head (FH), while confidence-weighted contour fitting explicitly suppresses the influence of unreliable boundary points in AoP computation. To further improve performance under heterogeneous acquisition conditions, we introduce a lightweight geometry-reliable test-time adaptation strategy as an auxiliary component, enabling stable inference without target annotations. Extensive evaluations on multi-center benchmarks demonstrate consistent reductions in AoP error and boundary metrics compared with state-of-the-art AoP methods. Our source code is available at https://github.com/baiyou1234/R2AoP.
Yuanhan Wang, Yifei Chen, Beining Wu +7
May 20, 2026cs.RO

Perception of Social Robots as Communication Partners in Healthcare for Older Adults

Addressing the global caregiver shortage through socially assistive robots necessitates a deep understanding of their psychological and physiological impacts on older adults during human-robot interaction (HRI). This study addresses whether social robots can serve as effective interaction partners compared to humans, and if "positive prompts" can similarly enhance these interactions. We conducted a comparative study with 35 participants (aged 70+). Our multi-modal analysis, integrating facial expression data, heart rate variability, and subjective questionnaires, revealed no significant differences in overall stress levels between human and robot interactions. Facial expression analysis confirmed that the robot was accepted as a valid interaction partner, while physiological data showed slightly lower heart rates during robot interactions, suggesting a more relaxed state compared to human-led sessions. These findings indicate that social robots can engage older adults without inducing psychological strain and are capable of alleviating caregiver burden by performing structured tasks, such as health-sensing surveys. Future work should address the identified "appearance-content mismatch" in robot design to facilitate even more natural and effective interactions.
Hana Yamamoto, Carlotta Julia Mayer, Charlotte Raithel +5
May 19, 2026cs.HC

AffectAI-Capture: A Reproducible Multimodal Protocol for Small-Group Meeting Research

We present AffectAI-Capture, a protocol for collecting synchronized multimodal data in four-person meeting-like interactions, combining eye tracking, wearable physiology, close-talk and room audio, multi-view video, event logging, and structured self-report. Sessions use fixed task blocks grounded in established group-interaction paradigms, while acquisition and post-processing are organized around a single authoritative event timeline and standardized outputs. We describe the experimental rationale, synchronization philosophy, data organization, and practical trade-offs. Pilot-level validation of audio quality and video synchronization has been conducted using controlled bench tests; full protocol sessions with participants remain ongoing work. The contribution is a reproducible protocol architecture linking task design, instrumentation, timing provenance, and data packaging for affective, behavioral, and meeting-analytics research.
Meisam Jamshidi Seikavandi, Alice Modica, Anna Obara +6
May 19, 2026physics.med-ph

Cross-View Attention Fusion Net: A Prior-Guided Dual-View Representation Learning for Cardiac Output Estimation from Short-Term PPG Signals

Accurate cardiac output (CO) estimation from photoplethysmography (PPG) is promising for unobtrusive hemodynamic monitoring, but remains difficult since CO is jointly determined by cardiac function and vascular tone. Conventional feature-based models use physiologically meaningful PPG descriptors, yet depend on accurate pulse detection and may miss latent temporal relationships. In contrast, fully end-to-end deep learning models learn directly from raw PPG but often underuse established PPG-derived prior information. Here, we introduce the Cross-View Attention Fusion Network (CVAF-Net), a prior-guided dual-view deep learning model for CO estimation from short, fixed-length PPG segments. CVAF-Net processes raw PPG as a temporal view and a feature sequence map (FSM) as a structured prior-guided view, and fuses the two representations through cross-view attention. The model was independently evaluated using 5-, 15-, and 30-s segments from three datasets: simulated pulse waves (3323 subjects), vasoconstriction provocation (79 subjects), and resting/cycling activities (10 subjects), and was compared with multiple machine learning and deep learning benchmarks. CVAF-Net outperformed most benchmark methods and achieved performance comparable to a state-of-the-art Transformer-based model, with a mean absolute error (MAE) of 0.19 L/min (MAPE: 3.95%) on simulated data and high accuracy in real-world settings (minimum MAE: 1.20 L/min). Importantly, CVAF-Net reduced FLOPs by twelvefold compared with the leading Transformer-based model. Plausibility analysis showed physiologically consistent CO estimates, with expected correlations with age (ρ=0.274ρ= -0.274), heart rate (ρ=0.894ρ= 0.894), and systemic vascular resistance (ρ=0.740ρ= -0.740). These findings indicate that CVAF-Net provides an accurate, computationally efficient, and generalizable approach for continuous wearable-based CO monitoring.
Yaowen Zhang, Bo Cui, Libera Fresiello +3