Wearable Devices

Recent momentum

-42%

11 papers in the last 28 days · 0.2% of indexed attention

Twelve weeks of publication activity for this topic as it is defined today.

Weekly history

Recent digests

What was published in this topic, kept on the site without email delivery.

Period ending 2026-09-21

5 new papers

A weekly snapshot of new work published in Wearable Devices.

Period ending 2026-09-14

3 new papers

A weekly snapshot of new work published in Wearable Devices.

Period ending 2026-09-07

3 new papers

A weekly snapshot of new work published in Wearable Devices.

120 papers

Latest in Wearable Devices

Jun 10, 2026cs.RO

Improving Human Diving Endurance with a Field-Deployable, Untethered Exoskeleton

Human endurance in underwater locomotion is fundamentally restricted by high energetic demands to overcome drag and the finite supply of self-contained breathing gas. While exoskeleton technology can reduce the metabolic cost of humans in terrestrial locomotion, its potential to enhance human endurance during underwater diving remains entirely unexplored. Here, we present DiveMate, a field-deployable, untethered exoskeleton designed to improve human diving endurance via adaptive kick assistance in real-world underwater environments. During naturalistic diving, DiveMate increases the travel distance using a given energy (breathing gas) by 42.9% and extends dive duration by 54.9% through reducing gas consumption rate. Marked reductions in muscle activation indicate a decrease in physiological exertion, with the net gas consumption rate decreasing by 47.0%. Kinematic characteristics and regularity improvements further underpin efficient energy economy. These results suggest that applying exoskeleton assistance is beneficial for improving human diving endurance and augmenting their ability to explore the aquatic world. This study extends the application frontier of exoskeletons and provides a potential reference for the design and assessment of future underwater assistive devices.
Zhihao Zhou, Zhenmeng Ju, Rui Yang +8
Jun 5, 2026cs.CV

OpenGlass: Ultra-Low-Power On-Device AI Eyewear with Event-based Vision

Smart eyewear enables unobtrusive, context-aware interaction through multimodal sensors and on-device intelligence, but is severely limited by power, memory, and compute constraints in a compact form factor. Open-hardware platforms supporting event-based vision and embedded ML at this scale are rare. This work introduces an open-source smart glasses platform for rapid prototyping of novel sensors and algorithms. Its modular design uses a flexible FPC interposer to support both event-based and frame-based cameras without full PCB redesign. A hardware-software co-designed power management system combines a configurable PMIC with event-driven wake-up via an nRF5340 coordinator, keeping the GAP9 RISC-V SoC powered down between inferences. The prototype achieves up to 11.5 hours of continuous on-device ML from a 200 mAh battery. As a demonstration, an egocentric hand gesture recognition pipeline was evaluated on the LynX dataset using polarity-separated event histograms from a Prophesee GENX320 camera. R(2+1)D achieved the best cross-subject accuracy of 83.94% (macro F1 = 0.781) under leave-two-subjects-out validation, with 78.3 ms end-to-end inference latency on the GAP9. Temporal augmentation and removal of ambiguous classes provided the largest gains (+8.9 pp). All hardware designs, firmware, and models are released open source.
Pietro Bonazzi, Julian Moosmann, Ahmet Celik +2
Jun 3, 2026cs.RO

OLIVE: Online Low-Rank Incremental Learning for Efficient Adaptive Exoskeletons

Wearable exoskeleton systems hold promise for restoring mobility in individuals with physical impairments, yet most existing controllers rely on static gait policies that lack the ability to adapt to dynamic real-world environments or individual user characteristics. We present \olive (\underline{O}nline \underline{L}ow-rank \underline{I}ncremental Learning for Efficient Adapti\underline{ve} Exoskeletons), a parameter-efficient online adaptation framework that continuously personalizes exoskeleton control during deployment. \olive decomposes the adaptive component of the control policy into a low-rank residual form~\dW=\At\Bt⊤\dW = \At\Bt^\top with rank~r!≪!min⁡(d,k)r!\ll!\min(d,k), reducing online update cost from O(dk)\mathcal{O}(dk) to O(r(d+k))\mathcal{O}(r(d{+}k)) while preserving the stability of a pretrained base controller~\Wz\Wz. Parameters are updated via a reward-shaped policy gradient driven purely by on-body sensor feedback (EMG, IMU, vibration), eliminating dependence on offline reference trajectories. A gating mechanism modulates the strength of personalization based on contextual state, and a dynamic rank scheduler adapts the update dimensionality to terrain complexity -- allocating minimal capacity on simple flat terrain and expanding to higher-rank updates on demanding uneven surfaces -- enabling robust performance across diverse activities: flat walking, stair navigation, slopes, and uneven terrain. Experiments on the wearable platform demonstrate that \olive achieves +13, +22, and +15 percentage-point improvements in gait smoothness, effort reduction, and motion stability over the strongest baseline, converging within ∼\sim1{,}800 walking steps at 7.4,ms end-to-end latency. Our code implementation is available at https://github.com/FastLM/OLIVE.
Dong Liu, Yanxuan Yu, Ben Lengerich +2
Jun 2, 2026cs.CV

AmbientEye: A Dataset for Pupil Segmentation under Natural Ambient Infrared Illumination

Eye tracking is essential for smart glasses, as it provides insight into user attention for ambient intelligence applications. However, most existing eye-tracking systems rely on active infrared (IR) illumination, creating practical barriers to all-day outdoor use due to power consumption. In this paper, we investigate whether passive IR cameras alone, without any active IR light source, can enable reliable pupil detection in unconstrained outdoor environments, where ambient sunlight serves as the sole illumination source. To support this investigation, we introduce AmbientEye, a large-scale dataset of 2,606,225 eye images collected from 35 participants from 19 countries. It is captured outdoors under natural sunlight with two off-axis camera configurations and two sun-orientation conditions. We provide high-quality pupil annotation through SAM2 automatic segmentation, followed by refinement by human annotators. We benchmark a state-of-the-art pupil segmentation algorithm on our dataset and compare its performance with that on existing datasets under controlled IR illumination. Results reveal a substantial drop in pupil segmentation performance from 0.928 on controlled IR datasets to 0.767 on AmbientEye. This performance gap highlights the challenge of the ambient-light setting. This positions AmbientEye as a first benchmark for an unexplored and highly practical eye-tracking scenario.
Mingyu Han, Hyunyoung Han, Nitheekulawatn Thommakoon +4
Jun 1, 2026cs.RO

Impact of a Soft Wearable Back-Support Device on Postural Stability during Trip-Like Perturbations

The effectiveness of a soft wearable back-support device in enhancing postural stability was investigated under trip-like perturbations using two experimental paradigms: perturbed standing and perturbed walking. Healthy subjects completed trials under three different back-support conditions: no device, device worn with low stiffness, and device activated with high stiffness. Whole-body stability was quantified using the minimum Margin of Stability (MOS) at the point of maximal instability. Results demonstrated increased MOS during device use, indicating enhanced postural stability. In standing, MOS increased significantly with device stiffness, whereas in walking, both device conditions improved MOS relative to no device but did not differ significantly from each other. These findings highlight the potential of soft wearable back-support devices with adjustable stiffness to improve reactive balance control against external perturbations, with important implications for fall prevention. Future research should explore personalized stiffness optimization and evaluate efficacy in populations at elevated risk of falls.
Yuanhao Chen, Rohan Khatavkar, Soubhagya Nayak +2
Jun 1, 2026cs.LG

ArrythML: An Autoencoder-Based TinyML Approach for On-Device Arrhythmia Detection on Resource-Constrained Embedded Systems

Our work presents a method for ECG segmentation and arrhythmia detection using Tiny Machine Learning (TinyML) models for real-time, on-device inference on resource-constrained embedded systems. We develop INT8 quantized autoencoder-based TinyML models with minimal layers and parameters for embedded deployment. These models are evaluated using a custom dataset derived from the MIT-BIH Arrhythmia Database and validated in both PC-based simulations and on-device environments. For the evaluations, over 95,000 ECG segments are processed on an ESP32-S3 microcontroller running the TensorFlow Lite Micro runtime. Post-evaluation, detailed analysis, including annotation-wise and record-wise failure analysis, is conducted to characterize model behavior across diverse ECG morphologies and rhythm patterns and to explain missed detections. In several cases, apparent misclassifications may correspond to early or subtle anomaly patterns labeled as normal in the reference annotations, highlighting the model's sensitivity. A refined evaluation by filtering out ambiguous cases in the dataset shows that the best-performing DNN-based autoencoder achieves a recall of 84%, an F1-score of 79%, a model size of approximately 180 KB, and an inference latency of 9 ms on-device. These results demonstrate the feasibility of low-power, privacy-preserving embedded wearable systems capable of performing accurate arrhythmia detection entirely on-device.
Nagarajan S, Kurian Polachan
May 31, 2026cs.HC

pcbGPT: Automatic PCB Schematic Synthesis from Natural Language Requirements

Translating natural-language hardware requirements into correct printed circuit board (PCB) schematics remains difficult in embedded, IoT, and wearable development. Designers must choose compatible components, interpret datasheets, add support circuitry, and expose correct interfaces before layout and prototyping can begin, while many such circuits cannot be validated through straightforward simulation. We present pcbGPT, a grounded system for generating editable KiCad schematics from natural-language specifications. pcbGPT represents circuits in a Python DSL and combines tool-augmented synthesis with component-library search, datasheet-grounded design knowledge, execution-based checking, structural and semantic validation, and an interactive web workflow that supports iterative refinement and synchronization with KiCad projects. We evaluate the system on 20 embedded schematic-generation tasks with reference implementations, required components, and interface constraints that enable automatic comparison. The best model reaches overall pass@1 of 0.90 and pass@5 of 1.00; pass@1 is 1.00 on basic and easy tasks, 0.91 on medium tasks, and 0.72 on hard tasks. These results, together with failure analysis, show that pcbGPT can already generate useful, reviewable first-draft schematics for early prototyping, but is not yet reliable enough to replace expert review.
Tobias King, Steven Kehrberg, Michael Beigl +1
May 30, 2026cs.CV

SuperMemory-VQA: An Egocentric Visual Question-Answering Benchmark for Long-Horizon Memory

AI glasses present a compelling platform for AI agents to serve as personalized memory assistants. To be genuinely useful, such systems must move beyond short-term video comprehension and address memory gaps that humans experience for practical, personal, or social purposes over longitudinal egocentric video streams. However, existing egocentric datasets predominantly focus on action recognition or generic QAs from short clips, measuring perceptual capabilities rather than realistic human memory needs. We introduce SuperMemory-VQA, an egocentric visual question answering (VQA) dataset for evaluating AI assistants on practical, long-horizon memory tasks. It contains 52.9 hours of everyday activities recorded with AI glasses, including synchronized RGB video, audio transcription, eye gaze, IMU, and SLAM trajectories. Through a human-verified annotation pipeline, we construct grounded 4,853 question-answer pairs that span object and location memory, intent recall, visual scene recall, timeline reconstruction, conversational memory, and in-context retrieval. Each question is posed as multiple-choice with an explicit "unanswerable" option to test hallucination robustness. Benchmarking leading agentic frameworks and LLM backbones reveals that existing systems remain far from reliable on real-world memory tasks, highlighting the need for new architectures for grounded AI memory that can answer only when evidence is sufficient. A participant survey further supports that our questions are realistic, useful, and aligned with everyday memory needs.
Samiul Alam, Shakhrul Iman Siam, Michael J. Proulx +4
May 29, 2026cs.LG

Longitudinal Multimodal Sensing of Physical Activity and Well-Being in Older Adults

Wearable and mobile sensing technologies enable continuous monitoring of human behavior and health in real-world settings. However, predictive modeling in longitudinal multimodal data remains challenging, particularly when targeting complex or clinically derived outcomes. In this work, we present a longitudinal multimodal study of 66 older adults conducted in real-world conditions and combining wearable sensing, behavioral monitoring, and clinical assessments. This setting provides a rare opportunity to study an underrepresented population in long-term, into-the-wild conditions. Building on this dataset, we investigate how the alignment between sensed signals and target variables affects predictive performance across health-related tasks. We design a unified evaluation framework spanning tasks with increasing levels of observability, including Activity Levels prediction, Sleep Duration estimation, and Sleep Apnea Severity classification. Our results reveal a clear gradient of predictability: highly observable behavioral targets achieve robust performance (macro-F1 65%), while more abstract outcomes remain challenging despite consistent improvements over baseline models. Moreover, through explainability analysis, we show that historical features consistently emerge as the most informative predictors, highlighting the central role of longitudinal information.
Flavio Di Martino, Mattia G. Campana, Marcello Magno +2
May 29, 2026cs.LG

DEM: A Distilled Explanation Model for Interpretable Anomaly Detection in Physiological Sensor Networks

Anomaly detection in physiological sensor data from Wireless Body Area Networks (WBANs) can be caused by sensor faults, network disruptions, or missing data, leading to false alarms. Hence, it demands both high predictive accuracy and clinically interpretable explanations. Existing approaches rely either on black-box models that achieve strong performance but offer no transparency, or on post-prediction explanation methods such as SHAP and LIME. In this paper, we propose the Distilled Explanation Model (DEM), a three-stage glass-box framework that distills the non-linear knowledge of a gradient boosting expert into an interpretable decision tree operating on residuals relative to a linear baseline, so that the explanation is not an approximation but the prediction itself. DEM introduces a novel distillation fidelity metric that quantifies how faithfully the explanation tree captures the expert model's non-linear contribution, providing a principled measure of explanation trustworthiness absent from prior interpretable models. Evaluated across four physiological datasets, including MIMIC-IV, WESAD, eICU, and an in-house SmartNet WBAN corpus, DEM achieves an AUC of 0.9964 on clinical contextual anomaly detection and 0.9047 on wearable stress detection while producing human-readable if-then rules at a controllable depth. Inference requires 0.17ms per 1000 samples, rendering DEM 1235x faster than SHAP-based post-hoc explanation and suitable for real-time physiological monitoring. Ablation studies confirm that the XGBoost distillation step provides measurable gains over naive residual fitting, and depth-sensitivity analysis demonstrates an explicit, user-controlled accuracy-interpretability trade-off unique to DEM among existing intrinsically interpretable models.
Jyotirmoy Singh, Anushka Roy, Shreea Bose +1
May 29, 2026cs.LG

Adaptive data selection improves wearable prediction under low baseline performance

Adaptive sensing strategies that selectively sample data are increasingly used in wearable health systems to improve prediction performance under limited data budgets, yet their benefits across individuals remain poorly understood. Here, we evaluate adaptive selection of time windows for model training under fixed measurement budgets across multiple sensing modalities, including heart rate, activity, and ecological momentary assessment (EMA), in a longitudinal wearable dataset. We quantify performance gains relative to random sampling using both area under the receiver operating characteristic curve (AUROC) and F1 score. Adaptive strategies yield substantial improvements in AUROC for participants with low baseline performance (with gains up to 0.7), while offering limited or negative gains for participants with strong baselines. Across modalities, adaptive gain is strongly inversely correlated with baseline performance (Pearson r = -0.67; Spearman p = -0.62). At the participant level, most individuals benefit in AUROC (60-80% across modalities), although improvements in F1 are smaller and less consistent. These findings show that adaptive sensing is not uniformly beneficial, but instead provides the greatest value in underperforming settings. Our results support selective deployment strategies that tailor adaptive sensing based on baseline performance to improve efficiency in wearable health monitoring.
Ali Kargarandehkordi
May 28, 2026cs.RO

Joint Angle Estimation with Customized Wristband Based on Online Incremental Learning

Intelligent wearable technology plays an increasingly important role in human-computer interaction, motion, and health monitoring. To ensure comfort and practicality of use, one common form for motion monitoring is to utilize soft wearable sensors. However, many research applications regarding wearable sensors are simplistic and difficult to adapt to different situations. This study proposes a system for estimating the angle of the wrist joint using a customized wristband based on an online incremental learning approach. It is a two-stage estimation method: the first stage updates the model based on the wearer's wrist movement characteristics using online learning, integrating real-time data from an IMU as ground truth. The second stage utilizes the updated model for estimation of wrist joint angle solely with the wristband. In other words, model training is completed during data acquisition, allowing the trained model to be used for subsequent angle estimation. This method offers advantages in adapting to data drift caused by variations in different testing configurations, such as the left and right wrists of the same subject, deviations in the wearing position on the same wrist, and even differences among various subjects. The results indicate that the sensors exhibit good performance under strain variations, and the wrist joint trajectory estimation of the proposed system has an approximate error of 15 degree in different scenarios.
Shuo Wang, Xiaobin Chen, Xiaoming Tao
May 28, 2026cs.AI

VitalAgent: A Tool-Augmented Agent for Reactive and Proactive Physiological Monitoring over Wearable Health Data

Wearable devices enable continuous monitoring of physiological signals such as ECG and PPG, but existing mHealth systems are largely limited to task-specific prediction pipelines or reactive question answering over static summaries. They lack the ability to support temporal reasoning, persistent physiological context, and proactive monitoring over long-term signal streams. We propose VitalAgent, a tool-augmented agentic framework for ECG/PPG-based mHealth that supports both reactive question answering and proactive monitoring. VitalAgent is built on a longitudinal physiological memory and a tool-augmented reasoning interface that enables dynamic computation over raw signals. We further introduce VitalBench, a longitudinal physiological monitoring benchmark dataset comprising 1,862 QA pairs for reactive question answering and 90.2 hours of continuous ECG/PPG recordings for proactive monitoring, covering cardiac, physical activity, and stress-related tasks. Experiments demonstrate that VitalAgent achieves over 25% improvement over prompt-based and ReAct baselines in reactive evaluation and supports proactive alert monitoring over long-term physiological signals, highlighting the importance of dynamic tool use and long-term physiological monitoring.
Di Zhu, Yu Yvonne Wu, Hong Jia +3
May 26, 2026cs.CV

Beyond Motion Primitives: Behavioral Activity Recognition from Head-Mounted IMU

AR smart glasses need continuous behavioral context to offer proactive assistance, yet their most practical always-on sensor, the head-mounted Inertial Measurement Unit (IMU), detects only motion primitives such as walking or standing. We push beyond motion primitives to behavioral-level recognition, defining five categories that balance AR application need with sensor observability. To this end, we construct a 160K-sample Ego4D dataset with a four-tier quality assurance framework spanning 8 activity scenarios, and propose HiT-HAR, a 703K-parameter hierarchical model that outperforms prior head-mounted IMU models on five-class action and eight-class scenario recognition. We further map the observability frontier of head-mounted IMU through per-class separability analysis, identifying which behavioral categories are reliably observable (Locomotion), which benefit from temporal context (Object Transfer, Task Operation), and where scenario-dependent signal overlap poses remaining challenges. Our results indicate that architectural choices exploiting temporal context and scenario structure outperform simply scaling model size. The code and dataset are publicly available at https://github.com/Harvard-AI-and-Robotics-Lab/HiT-HAR.
Chung-Ta Huang, Leopold Das, Jeffrey Zhou +10
May 22, 2026cs.HC

Detecting Drunk Driving Using Off-the-Shelf Smartwatches

Alcohol-impaired driving remains a major yet preventable cause of road traffic injury and death, with many drivers underestimating their level of intoxication. Compared to in-vehicle systems, mobile drunk-driving detection using consumer smartwatches offers a scalable way to trigger preventive interventions and increase awareness without additional in-vehicle hardware. We introduce a system that leverages wrist accelerometer data and heart rate variability-derived physiological signals to detect alcohol-related driving impairment. We collected data in a randomized, controlled three-arm test-track study (n=54) and trained both logistic regression models with window-aggregated features and a two-tower 1D convolutional neural network (CNN), to detect alcohol-impaired driving. The CNN achieved a participant-averaged area under the receiver operating characteristic (AUROC) of 0.88 for detecting any alcohol intoxication and 0.86 for detecting driving above the WHO-recommended limit of 0.05 g/dL. To the best of our knowledge, this is the first work to (1) demonstrate drunk-driving detection using consumer smartwatches, (2) develop and evaluate such a system in a real vehicle on a closed test track, and (3) rigorously assess generalization to unseen participants. Together, these findings highlight the potential of wearable-based sensing to support scalable, measurement-driven prevention of alcohol-related traffic harm.
Robin Deuber, Lanlan Yang, Michal Bechny +9
May 22, 2026cs.LG

Federated Learning over Human-Body Communication for On-Body Edge Intelligence: A Survey, Taxonomy, and BODYFED-HBC Scheduling Vignette

Human-body communication (HBC) is a promising physical substrate for wearable body-area networks because it can localize communication around the body and reduce the burden of conventional radio links. Federated learning (FL) is a promising learning substrate because it can reduce raw-data centralization for physiological and behavioral sensing. Yet these two literatures remain weakly connected: FL for wearables usually abstracts the communication layer, whereas HBC research usually abstracts learning and model-update traffic. This article surveys the intersection of HBC, wireless body-area networks, wearable FL, Internet-of-Bodies privacy, and edge-intelligence optimization. We propose a taxonomy that distinguishes intra-body, body-hub, cross-user, and clinical-cloud FL deployments, and we identify the open problem of body-channel-aware FL: learning protocols whose client selection, update compression, and aggregation are controlled by posture-dependent HBC links, residual energy, sensor memory, and privacy risk. To make the research agenda concrete, we introduce BODYFED-HBC as a reference architecture and provide an optimization formulation and scheduling algorithm. We further specify a reproducible simulation vignette that combines public wearable datasets with empirical body-coupled-communication signal-loss models. The article concludes with open datasets, evaluation metrics, limitations, and research directions for computer scientists working above the hardware layer.
Koffka Khan
May 21, 2026cs.AI

Towards a General Intelligence and Interface for Wearable Health Data

While ubiquitous wearable sensors capture a wealth of behavioral and physiological information, effectively transforming these signals into personalized health insights is challenging. Specifically, converting low-level sensor data into representations capable of characterizing higher-level states is difficult due to high phenotypic diversity and variation in individual baseline health, physiology, and lifestyle factors. Moreover, collecting wearable data paired with health outcome annotations is laborious and expensive, and retrospective annotation remains practically unfeasible, contributing to a scarcity of data with high-quality labels. To overcome these limitations, we propose a foundation model for wearable health that is pretrained on more than one trillion minutes of unlabeled sensor signals drawn from a large cohort of five million participants. We demonstrate that the joint scaling of model capacity and pretraining data volume leads to systematic improvements in performance, as evaluated on a diverse set of 35 health prediction tasks, spanning cardiovascular, metabolic, sleep, and mental health, as well as lifestyle choices and demographic factors. We find that this population scale representation unlocks label-efficient few-shot learning and generative capabilities for robust daily metric estimation. To further leverage this learned representation, we deploy a classroom of LLM agents to autonomously search the space of downstream predictive heads built on the model embeddings, showing broad performance improvements that increase with LLM model capacity. Finally, we show how integrating these downstream predictors into a Personal Health Agent can support model responses that are more relevant, contextually aware, and safe, and we validate this via 1,860 ratings from a cohort of clinicians.
Girish Narayanswamy, Maxwell A. Xu, A. Ali Heydari +37
May 21, 2026cs.CV

AnyMo: Geometry-Aware Setup-Agnostic Modeling of Human Motion in the Wild

As wearable and mobile devices become increasingly embedded in daily life, they offer a practical way to continuously sense human motion in the wild. But inertial signals are highly dependent on the sensing setup, including body location, mounting position, sensor orientation, device hardware, and sampling protocol. This setup dependence makes it difficult to learn motion representations that transfer across devices and datasets, and limits the broader use of wearable IMUs beyond closed-set recognition. We introduce AnyMo, a geometry-aware framework for setup-agnostic human motion modeling. AnyMo uses physics-grounded IMU simulation over dense body-surface placements to generate diverse and plausible synthetic signals, pre-trains a graph encoder from paired synthetic placement views and masked partial observations, tokenizes multi-position IMU into full-body motion tokens, and aligns these tokens with an LLM for motion-language understanding. We evaluate AnyMo on three complementary tasks: zero-shot activity recognition across 14 unseen downstream datasets, cross-modal retrieval, and wearable IMU motion captioning, where it improves average Accuracy/F1/R@2 by 11.7%/11.6%/22.6% on HAR, increases zero-shot IMU-to-text and text-to-IMU retrieval MRR by 15.9% and 28.6%, respectively, and improves zero-shot captioning BERT-F1 by 18.8%. These results support AnyMo as a generalist model for wearable motion understanding in the wild. Project page: https://baiyuchen.com/project/AnyMo.
Baiyu Chen, Zechen Li, Wilson Wongso +5
May 19, 2026cs.CV

You Don't Need Attention: Gated Convolutional Modeling for Watch-Based Fall Detection

Existing deep learning approaches for wearable fall detection systems rely on self-attention mechanisms that impose quadratic computational overhead, distributing weights across all time steps. This global weight distribution impairs the precise localization of the brief impact signatures that characterize falls within short, fixed-length windows. To overcome this challenge, we propose Gated-CNN, a lightweight dual-stream architecture that processes accelerometer and gyroscope streams through independent one-dimensional convolutional feature extractors, followed by (i) a sigmoid gating module that selectively suppresses uninformative background activations while amplifying fall-discriminative features, (ii) a global average pooling layer that compresses each stream into a compact fixed-length descriptor, and (iii) a shared classification head that fuses both descriptors for binary fall prediction. For offline evaluation, we evaluate the model across five wrist-mounted inertial measurement unit (IMU) datasets, achieving average F1-scores of 93%, 93%, 90%, 91%, and 90% on SmartFallMM, WEDA-Fall, FallAllD, UMAFall, and UP-Fall, outperforming Transformer baselines. For real-time evaluation, we deployed the model on a Google Pixel Watch 3 and tested across 12 participants. The model achieves an average F1-score of 97% and an accuracy of 98% with zero missed falls, showing that sigmoid gating offers a more structurally aligned and computationally efficient alternative to attention for commodity smartwatch-based fall detection.
Sana Alamgeer, Ronish Kumar, Awatif Yasmin +2
May 18, 2026cs.HC

Multi-site PPG: An In-the-Wild Physiological Dataset from Emerging Multi-site Wearables

Wearables are widely used for mobile health monitoring, and photoplethysmography (PPG) is a key sensing modality for heart rate and related physiological measurements. However, public in-the-wild PPG datasets remain largely wrist-centric or limited to short, controlled studies, constraining research on emerging wearable form factors. We present Multi-site PPG, an in-the-wild physiological dataset collected from four custom-developed unobtrusive wearables: a smart earring, ring, watch, and necklace. Each device records green and infrared reflective PPG, 3-axis acceleration, and temperature with timestamps for cross-device alignment, while a Polar H10 chest strap provides reference electrocardiogram (ECG). Participants wore the devices for multiple days during daytime activities while continuing their normal routines. The dataset contains over 350 hours of raw data and 230-290 hours of modeling-ready 8-second windows per wearable. We benchmark heuristic, supervised, and self-supervised heart-rate estimation methods, showing substantial body-site differences: the best methods achieve mean absolute errors (MAEs) of 2.30 bpm on the earring, 5.13 bpm on the ring, 8.37 bpm on the watch, and 8.68 bpm on the necklace. We further analyze motion effects and evaluate multi-site and PPG-accelerometer fusion, demonstrating the dataset's value for robust physiological sensing across emerging wearable form factors.
Jiayi Shao, Jiaying Ye, Shengyao Liu +4
May 17, 2026cs.AI

Prediction of Challenging Behaviors Associated with Profound Autism in a Classroom Setting Using Wearable Sensors

Autism Spectrum Disorder (ASD) is characterized by challenges with social interaction and communication and by restricted or repetitive patterns of thought and behavior, with significant variability in presentation. Approximately a quarter of children with ASD are classified as having profound autism, who often exhibit challenging behaviors, such as self-injurious behavior, aggression, elopement, or pica, that pose serious safety risks and disrupt learning in educational settings. Prior work has applied wearable sensors and machine learning to detect challenging behaviors, but has been largely confined to controlled laboratory environments. This work demonstrates that predicting challenging behavior episodes is feasible in a real-world special education classroom. We collected approximately 110.7 hours of labeled multimodal wearable data comprising accelerometry, electrodermal activity (EDA), and skin temperature from 9 children and young adults aged 10 to 21 years across standard classroom sessions. We fine-tuned state-of-the-art foundation models for multimodal wearable time-series analysis and show that challenging behavior episodes can be predicted up to 10 minutes in advance with an AUC-ROC of 0.78. These results establish a concrete foundation for developing proactive in-class intervention systems that enable teachers to minimize the safety risks of challenging behaviors in special education classrooms
Yadhu Kartha, Conor Anderson, Jenny Foster +6
May 17, 2026cs.CV

SafeLens: Deliberate and Efficient Video Guardrails with Fast-and-Slow Screening

The rapid growth of online video platforms and AI-generated content has made reliable video guardrails a key challenge for safety and real-world deployment. While most videos can be screened through fast pattern recognition, a small subset requires deeper reasoning over temporally complex content and nuanced policy constraints. Existing approaches typically rely on large vision-language models applied uniformly across all inputs, resulting in high inference costs and inefficient allocation of computation. We propose SafeLens, a video guardrail framework that introduces a fast-and-slow inference architecture for efficient and accurate content moderation with variable computational cost across inputs. Additionally, we construct a high-quality dataset by applying influence-guided filtering to the SafeWatch Dataset, retaining only 2.4% of the original data. To further address limitations of training-time scaling, we enable test-time reasoning by augmenting the filtered data with structured Chain-of-Thought traces. Across real-world and AI-generated video benchmarks, SafeLens achieves state-of-the-art performance, outperforming strong open-source video guardrails (e.g., SafeWatch-8B, OmniGuard-7B) and closed-source models (e.g., GPT-5.4, Gemini-3.1-pro) while significantly reducing inference cost, demonstrating that efficient design serves to be more effective than scaling data or model size alone.
Shahriar Kabir Nahin, Hadi Askari, Muhao Chen +1
May 17, 2026cs.CV

EgoIntrospect: An Egocentric Dataset and Benchmark for User-Centric Internal State Reasoning

Despite extensive efforts on egocentric video datasets and benchmarks, understanding users' internal states, which is crucial for enabling seamless AI assistant experiences, remains largely overlooked. In this work, we introduce EgoIntrospect, the first egocentric dataset captured in user-driven scenarios with self-annotations that explicitly reveal users' interactive intentions with AI assistants. EgoIntrospect was collected using a cross-device setup, providing synchronized video, audio, gaze, motion, and physiological signals. It consists of 180 hours of recordings from 60 subjects, with an average recording duration of 3 hours per subject. Leveraging EgoIntrospect, we formalize a suite of tasks centered on user internal states, including affective experience, interactive intent, and cognitive memory. We further process the annotations to construct benchmarks that evaluate the ability of modern multimodal large language models to reason about users' internal states from egocentric observations. Experiments on our benchmark suggest that existing multimodal large language models struggle to effectively leverage multimodal signals to infer users' subjective internal states. The dataset and annotations will be made publicly available to advance research in egocentric vision and wearable AI assistants. Project page: https://ego-introspect.github.io/
Zeyu Wang, Chang Liu, Eduardus Tjitrahardja +22
May 15, 2026cs.LG

Towards Family-Grouped Hierarchical Federated Learning on Sub-5KB Models: A Feasibility Study of Privacy-Preserving ECG Monitoring for Ultra-Resource-Constrained Wearables

Cardiovascular disease remains the leading cause of death worldwide, and early detection of arrhythmias through continuous ECG monitoring on wearable devices can prevent life-threatening events. Federated Learning (FL) enables privacy-preserving collaborative training by keeping raw ECG data on device, yet standard FL incurs prohibitive communication overhead and standard deep learning models cannot fit on ultra-low-power microcontrollers. We propose Family-Grouped Hierarchical Federated Learning (Family-FL), a three-tier architecture that uses the family as a natural privacy boundary for intra-family aggregation before global synchronization. We further design a hardware-constrained Tiny CNN-LSTM architecture with only 669 parameters, INT8-quantized to occupy merely 4.65KB Flash and 2.95KB RAM, meeting the constraints of STC32G12K128-class microcontrollers. Experiments on the MIT-BIH Arrhythmia Database (mean of 5 independent runs with different seeds) demonstrate that Family-FL reduces communication volume by 76.7% compared to FedAvg while maintaining comparable accuracy. Family-FL-Tiny achieves 91.9 +/- 1.2% accuracy with macro-F1 of 0.483 +/- 0.031, reducing total communication to 0.31% of FedAvg. The model achieves reliable ventricular arrhythmia detection (per-class F1 = 0.80), the most clinically critical abnormality for home-based preliminary screening. These results demonstrate the technical feasibility of privacy-preserving federated learning on ultra-resource-constrained microcontrollers through simulation-based evaluation. We honestly discuss limitations: no hardware deployment, single-dataset validation (MIT-BIH, 47 subjects), reduced rare-class sensitivity, and absence of formal differential privacy guarantees.
Hangyu Wu
May 14, 2026cs.HC

A Formative Study of Brief Affective Text as a Complement to Wearable Sensing for Longitudinal Student Health Monitoring

Wearable devices capture physiological and behavioral data with increasing fidelity, but the psychological context shaping these outcomes is difficult to recover from sensor data alone, limiting passive sensing utility for digital health. We examined whether ultra-brief naturalistic concern text could serve as a scalable complement to passive sensing. In a year-long study of 458 university students (3,610 person-waves) tracked with Oura rings, participants responded bimonthly to an open-ended prompt about what concerned them most; responses had a median length of three words. We compared dictionary-based, general pretrained, and domain-adapted NLP approaches using within-person mixed-effects models across nine sleep and physical activity outcomes. Weeks dominated by academic concern framing were associated with lower physical activity; weeks characterized by emotional exhaustion language were associated with poorer sleep quality and lower heart rate variability. General pretrained embeddings outperformed domain-adapted models for most outcomes, with domain adaptation showing relative advantage for autonomic outcomes. Zero-shot classification of concern topics produced no significant associations, while affective dimensions across all three methods were consistently associated with outcomes, indicating emotional register rather than topical content carries the signal. These findings offer design guidance: ultra-brief affective prompts enrich the psychological interpretability of passive physiological data at minimal burden.
Tamunotonye Harry, Johanna Hidalgo, Matthew Price +7
May 13, 2026cs.LG

Uncertainty-Driven Anomaly Detection for Psychotic Relapse Using Smartwatches: Forecasting and Multi-Task Learning Fusion

Digital phenotyping enables continuous passive monitoring of behavior and physiology, offering a promising paradigm for early detection of psychotic relapse. In this work, we develop and systematically study two smartwatch-based frameworks for daily relapse detection. The first forecasts cardiac dynamics and flags deviations between predicted and observed features as indicators of abnormality. The second adopts a multi-task formulation that fuses sleep with motion and cardiac-derived signals, learning time-aware embeddings and predicting measurement timing. Both pipelines use Transformer encoders and output a daily anomaly score, derived from predictive uncertainty estimated via an ensemble of multilayer perceptrons to improve robustness to real-world wearable variability. While each framework independently demonstrates strong predictive power, we show that they capture complementary physiological signatures. Consequently, we propose a late-fusion strategy that synergistically combines the anomaly signals from both architectures into a unified decision score. We benchmark our methodology on the 2nd e-Prevention Grand Challenge dataset, where our fused model achieves a 8% relative improvement over the competition-winning baseline. Our results, supported by extensive ablation studies, suggest that the integration of diverse digital phenotypes, cardiac, motion, and sleep, is essential for the high-fidelity detection of psychotic relapse in real-world settings.
Nikolaos Tsalkitzis, Panagiotis P. Filntisis, Petros Maragos +1
May 13, 2026cs.LG

Efficient Sensor Fusion for Gesture Recognition on Resource-Constrained Devices

Gesture recognition is a cornerstone of Human-Computer Interaction (HCI) for smart eyewear, enabling natural and device-free control in augmented reality environments. Traditional vision-based approaches face significant challenges regarding power consumption, computational latency, and user privacy. This paper proposes a lightweight, privacy-preserving gesture recognition system based on the fusion of low-resolution Time-of-Flight (ToF) and Infrared (IR) thermal sensors. We used an 8 times 8 multizone ToF sensor (VL53L8CH) and an 8 times 8 IR array (AMG8833) to capture complementary depth and thermal cues. A compact Convolutional Neural Network (CNN) with a specialized grouped-convolution architecture is designed to fuse these modalities efficiently on a microcontroller (MCU). Experimental results on a custom dataset of 7 static gestures, validated via k-fold cross-validation, demonstrate that the proposed fusion strategy significantly outperforms single-sensor baselines with an accuracy of 92.3% and a macro F1-score of 0.93. Finally, on-device benchmarks on STM32F4 and STM32H7 MCUs confirm the system's suitability for resource-constrained wearables, requiring only 6,343 parameters and achieving millisecond-level inference latency with a total system power of 50 mW.
Pietro Bartoli, Christian Veronesi, Tommaso Bondini +2
May 12, 2026cs.LG

On What We Can Learn from Low-Resolution Data

Artificial intelligence systems typically rely on large, centrally collected datasets, a premise that does not hold in many real-world domains such as healthcare and public institutions. In these settings, data sharing is often constrained by storage, privacy, or resource limitations. For example, small wearable devices may lack the bandwidth or energy capacity needed to store and transmit high-resolution data, leading to aggregation during data collection and thus a loss of information. As a result, datasets collected from different sources may consist of a mixture of high- and low-resolution samples. Despite the prevalence of this setting, it remains unclear how informative low-resolution data is when models are ultimately evaluated on high-resolution inputs. We provide a theoretical analysis based on the Kullback-Leibler divergence that characterises how the influence of a datapoint changes with resolution, and derive bounds that relate the relative contribution of high- and low-resolution observations to the information lost under downsampling. To support this analysis, we empirically demonstrate, using both a vision transformer and a convolutional neural network, that adding low-resolution data to the training set consistently improves performance when high-resolution data is scarce.
Theresa Dahl Frehr, Niels Henrik Pontoppidan, Hiba Nassar +1
May 11, 2026cs.CV

Personal Visual Context Learning in Large Multimodal Models

As wearable devices like smart glasses integrate Large Multimodal Models (LMMs) into the continuous first-person visual streams of individual users, the evolution of these models into true personal assistants hinges on visual personalization: the ability to reason over visual information unique to the wearer. We formalize this capability as Personal Visual Context Learning (Personal VCL), the prompt-time capability of using user-specific visual context to resolve personalized queries. To systematically evaluate this, we present Personal-VCL-Bench, a comprehensive benchmark capturing the personal visual world across persons, objects, and behaviors. Our analysis of frontier LMMs identifies a profound context utilization gap, revealing that the mechanisms for leveraging visual evidence, as well as aggregating multiple visual observations, remain critically understudied. Motivated by these findings, we propose the Agentic Context Bank, a strong inference-time baseline that structures a user's visual context into a self-refining memory bank and employs query-adaptive evidence selection. Our baseline approach consistently improves over standard context prompting regimes across tasks and evaluated backbones, demonstrating a practical path towards future personalized LMMs.
Zihui Xue, Ami Baid, Sangho Kim +2
May 9, 2026cs.LG

WavesFM: Hierarchical Representation Learning for Longitudinal Wearable Sensor Waveforms

Wearable sensors enable the continuous acquisition of high-resolution physiological waveforms, such as photoplethysmography and accelerometry, under free-living conditions. However, inferring health-related phenotypes from these signals presents significant challenges due to high sampling frequencies, multimodal dependencies, and extreme sequence lengths (e.g., weeks of recordings), compounded by a scarcity of ground-truth labels. To address these challenges, existing self-supervised learning (SSL) methodologies typically follow two paradigms: (1) learning rich morphological representations from short waveform segments while collapsing longitudinal dynamics through simple aggregation, or (2) modeling behavioral patterns from coarse, hand-crafted features (e.g. heart rate, step counts) spanning longer horizons but foregoing subtle, predictive signatures in raw waveforms. To bridge this gap, we propose WavesFM, a foundation model utilizing a two-stage SSL framework for longitudinal physiological data. Specifically, we decompose the learning problem into two stages: first, a segment-level encoder is pretrained to extract local embeddings from short waveforms; subsequently, a temporal encoder is trained to model the sequence of these embeddings across a multi-day horizon. This hierarchical approach overcomes the computational complexity of high-resolution, long-sequence data, allowing the overall model to capture both local signal semantics and the complex circadian and inter-day variations governing physiological dynamics. Pretrained on over 6.8M hours (N=324k individuals) of recordings for the first stage and 5.3M hours (N=10k) for the second stage, WavesFM demonstrates superior performance across 58 diverse tasks spanning demographics, lifestyle, health conditions, and medications.
Peng Cao, Zhijian Yang, Tennison Liu +17
May 8, 2026cs.LG

SGC-RML: A reliable and interpretable longitudinal assessment for PD in real-world DNS

Real-world digital Parkinson's disease assessment faces challenges such as heterogeneous modalities, cross-device bias, and incomplete labeling. Existing methods often focus on average predictive performance, lacking the reliability mechanisms needed for retrospective reliability-aware assessment - namely, determining when the model is reliable, when to reject an assessment, when to retest, and from which symptom dimensions the predictions are based. This paper proposes SGC-RML, which maps speech, gait, wearable motion, mobility tasks, and clinical variables to a shared 8-dimensional symptom node space (7 clinical symptom nodes and 1 reliability_state auxiliary node), unifying motor and non-motor representations through a symptom atlas. By jointly introducing uncertainty estimation, conformal calibration, and selective decision routing, the model can not only predict symptoms and severity but also reject assessments or suggest retests when evidence is insufficient. We validate this framework on five real-world PD datasets, covering classification, regression, event detection, and longitudinal severity prediction. Experiments show that SGC-RML achieves an MAE of 4.579 / R^2 of 0.772 on PPMI, an AUC of 0.953 on mPower, and an AUC of 0.825 on PADS. Under leak-free temporal anchoring, as few as 5 subject-specific anchors transform UCI from an essentially non-predictive subject-independent setting (motor MAE 8.38, CCC 0.02) into a calibrated longitudinal assessment (motor MAE 3.24, CCC 0.756) with split-conformal coverage held at the 0.80 target. Under the Daphnet LOSO protocol, it achieves an F1 of 0.803 / AUC of 0.872. These results demonstrate that SGC-RML provides a unified paradigm for accurate, calibrated, auditable, and symptom-interpretable retrospective longitudinal assessment of PD under incomplete multimodal conditions.
Wenbin Wei, Ruixiang Gao, Suyuan Yao +3
May 7, 2026cs.CV

iPhoneBlur: A Difficulty-Stratified Benchmark for Consumer Device Motion Deblurring

Motion blur restoration on consumer mobile devices is typically evaluated using aggregate metrics that obscure performance variation across blur difficulty, masking model behavior under real deployment conditions. This work introduces iPhoneBlur, a difficulty-stratified benchmark of 7,400 image pairs synthesized from high-framerate iPhone 17 Pro videos captured in diverse real-world scenarios. Samples are partitioned into Easy, Medium, and Hard categories through PSNR-guided adaptive temporal windowing, with stratification validated by monotonic 2.2x increase in optical flow magnitude across tiers. Each sample includes comprehensive metadata enabling investigation of ISP-aware and difficulty-adaptive restoration strategies. Spectral analysis confirms synthesized blur exhibits high-frequency suppression patterns consistent with authentic motion degradation. Evaluation of six architectures reveals consistent 7-9 dB performance degradation from Easy to Hard subsets, a substantial gap entirely hidden by aggregate reporting. The benchmark further exposes a domain gap between professional and consumer cameras which targeted fine-tuning substantially recovers. By coupling difficulty stratification with deployment-critical metadata, iPhoneBlur enables systematic assessment of model reliability and failure modes for resource-constrained edge systems.
Abdullah Al Shafi, Kazi Saeed Alam
May 5, 2026eess.SP

Domain-Adaptive Arrhythmia Classification Using a Hybrid Transformer on Wearable Heart Signals

Cardiovascular disease remains the leading cause of death globally, underscoring the need for effective, accessible monitoring solutions, particularly through wearable devices that enable continuous, real-time tracking of heart rhythms in home settings. However, deploying deep learning models trained on clinical electrocardiogram (ECG) datasets to wearable devices remains challenging, as differences in recording equipment, signal quality, and patient populations introduce domain shifts that degrade model performance. We propose a hybrid transformer model that processes continuous ECG signals alongside seven heart rate variability (HRV) features, where the raw signal path captures beat-level morphological patterns and the HRV path encodes rhythm regularity statistics, allowing the model to jointly leverage complementary information from both representations. To enhance the model's ability to generalize across domains, we employ representation learning techniques, including Maximum Mean Discrepancy (MMD), a non-parametric kernel-based metric that quantifies the distance between feature distributions of different domains, to align feature distributions between source and target domains, addressing the challenge of domain shifts between public datasets and wearable device data. By leveraging five public ECG datasets for training, the model learns robust, generalized representations that mitigate domain-specific biases. When tested on wearable device data with an unseen domain, the model achieved an F1-macro 95% and balanced accuracy of 96.15%. These results demonstrate minimal performance degradation, with only a 2% drop in F1-macro compared to seen-domain evaluation, highlighting the model's generalization capabilities and its potential for reliable, real-time heart monitoring applications in home and ambulatory settings.
Maedeh H. Toosi, Siamak Mohammadi
May 4, 2026eess.SP

Memory-Efficient EDA Denoising via Knowledge Distillation for Wearable IoT Under Severe Motion Artifacts and Underwater Conditions

Electrodermal activity (EDA) is widely used in wearable Internet of Medical Things (IoMT) systems for continuous health monitoring, including autonomic assessment. However, EDA signals are highly vulnerable to motion artifacts and environmental noise, limiting reliable deployment in harsh operating conditions such as underwater. This study proposes a robust, deployable EDA denoising framework that generalizes across multiple measurement locations and harsh environments. The framework integrates a hybrid CNN-Transformer teacher model with a lightweight depth-wise separable CNN student model via a knowledge distillation (KD) strategy. To further improve robustness, a realistic data augmentation scheme is introduced to simulate diverse motion artifacts and environmental distortions. The KD-based student model significantly reduces model size (7.87 MB to 0.51 MB) and computational cost (105.1M to 11.61M FLOPs) while maintaining denoising performance (MAE: 0.144, SNR improvement: 12.08 dB) using the public dataset validation. In real-world underwater conditions (UMAC dataset) testing, the proposed method substantially improves skin conductance response reconstruction, reducing mean absolute error from 2.809 to 0.215. Furthermore, on independent testing using the CNS-OT dataset, the denoised signals enhanced downstream CNS-OT prediction performance, achieving the highest AUROC (0.806) compared to prior denoising methods. The proposed method also improved the early prediction rate (sensitivity) from 0.550 to 0.767, enabling CNS-OT prediction up to a median of 6.9 minutes before symptom onset. These results demonstrate that the proposed framework not only improves EDA signal quality but also enhances clinically relevant prediction performance while remaining suitable for deployment in resource-constrained wearable Internet of Things systems operating in harsh environments.
Yongbin Lee, Andrew Peitzsch, Youngsun Kong +4
May 4, 2026cs.LG

HARMES: A Multi-Modal Dataset for Wearable Human Activity Recognition with Motion, Environmental Sensing and Sound

With each sensing modality exhibiting inherent strengths and limitations, multi-modal approaches for wearable Human Activity Recognition (HAR) are becoming increasingly relevant -- particularly for recognizing Activities of Daily Living (ADLs), where individual modalities often produce ambiguous signals for similar or complex activities. This work introduces HARMES, a multi-modal wearable dataset combining three wrist-recorded modalities: motion sensing via an Inertial Measurement Unit (IMU), atmospheric environmental sensors (humidity, temperature, and pressure), and audio. Collected from 20 participants performing household activities in their own homes, HARMES totals over 80 hours of recorded data, with approximately three hours of labeled activity data per participant across 15 ADL classes. To the best of our knowledge, HARMES is the first dataset to combine this particular sensor trio, and it is nearly six times larger than the previously largest wrist-inertial-acoustic HAR dataset. In an extensive benchmark, we evaluate cross-subject generalization and conduct an ablation study revealing that modality contributions are activity-dependent and can provide complementary value, particularly for activities that are ambiguous from motion data alone. HARMES is freely available at Zenodo, alongside example code for loading the dataset and training models on GitHub.
Robin Burchard, Pascal-André Brückner, Marius Bock +2
Apr 30, 2026cs.LG

Introducing WARM-VR: Benchmark Dataset for Multimodal Wearable Affect Recognition in Virtual Reality

With the growing integration of human-computer interaction into everyday life, advances in machine learning have enabled systems to better perceive and respond to users' emotional states. Most existing affect recognition datasets focus on static environments, limiting their applicability to immersive multimedia contexts such as Virtual Reality (VR). In this paper, we introduce WARM-VR, a novel publicly available multimodal dataset designed to support affect recognition in immersive, multisensory environments using wearable sensing instrumentation. Data were collected from 31 participants aged 19-37 using wearable sensors: a wristband measuring Blood Volume Pulse (BVP), EDA, skin Temperature, three-axis Acceleration, and a chest strap recording ECG signals. Participants engaged in immersive VR experiences designed to elicit relaxation through a calming beach environment following stress induction via an arithmetic task. These sessions incorporated synchronized multimedia stimuli: visual, auditory, and olfactory. Affective states were assessed subjectively through validated self-report questionnaires and objectively through the analysis of physiological measurements. Statistical analysis of the questionnaires confirmed that VR relaxation significantly reduced negative affect, particularly with olfactory enhancement. Furthermore, we established a benchmark on the dataset using widely recognized machine learning algorithms. The best performance for binary classification from BVP data of valence, was obtained with a CNN and a CNN-Bi-GRU model, both achieving an average F1-score of 0.63 and an AUC of 0.69. For arousal, a lightweight Transformer architecture provided the most balanced results (F1-0 0.54 and F1-1 0.63), outperforming recurrent hybrids. In the relaxation task, a CNN-Bi-GRU model reached the highest overall performance (average F1-score 0.64, AUC 0.69).
Karim Alghoul, Faisal Mohd, Fedwa Laamarti +2
Apr 29, 2026cs.CV

Leveraging Imperfect Medical Data: A Manifold-Consistent Spatio-Temporal Network for Sensor-based Human Activity Recognition

Sensor-based Human Activity Recognition (HAR) has attracted increasing attention in medical and healthcare monitoring, particularly with the growth of Internet of Medical Things (IoMT). However, in real-world wearable sensing scenarios, IoMT signals are often corrupted by missing measurements, sensor failures, and environmental noise, which significantly degrade the performance of conventional deep learning models that assume clean and complete inputs. To address this challenge, we propose a Manifold-Consistent Spatio-Temporal Network (MCSTN) for robust HAR under imperfect sensing conditions. The proposed framework introduces a dual-level corruption modeling mechanism that simulates realistic sensor imperfections through both physical-level corruption and diffusion-driven continuous corruption. By enforcing representation consistency across multiple corrupted views, the model learns stable and corruption-invariant semantic representations. Furthermore, we design a dual-stream spatio-temporal architecture that explicitly decouples temporal dynamics modeling and spatial correlation learning. The temporal stream captures long-term activity dynamics, while the spatial stream models inter-sensor relationships, enabling more effective spatio-temporal representation learning. Extensive experiments on three widely used HAR benchmark datasets, PAMAP2, Opportunity, and WISDM, demonstrate that the proposed MCSTN achieves competitive performance compared with existing state-of-the-art methods, particularly under imperfect sensing conditions. These results validate the effectiveness and robustness of the proposed framework for real-world wearable IoMT sensing applications.
Jiangtao Fan, Anish Jindal, Amir Atapour-Abarghouei
Apr 28, 2026cs.AR

At the Edge of the Heart: ULP FPGA-Based CNN for On-Device Cardiac Feature Extraction in Smart Health Sensors for Astronauts

The convergence of accelerating human spaceflight ambitions and critical terrestrial health monitoring demands is driving unprecedented requirements for reliable, real-time feature extraction on extremely resource-constrained wearable health sensors. We present an ultra-low-power (ULP) Field-Programmable Gate Array (FPGA) based solution for real-time Seismocardiography (SCG) feature classification using Convolutional Neural Networks (CNNs). Our approach combines quantization-aware training with a systolic-array accelerator to enable efficient integer-only inference on the Lattice iCE40UP5K FPGA, which offers an ideal platform for battery-powered deployments -- particularly in space environments -- thanks to its power efficiency and radiation resilience. The implementation achieves a validation accuracy of 98% while consuming only 8.55 mW, completing inference in 95.5 ms with minimal hardware resources (2,861 LUTs and 7 DSP blocks). These results demonstrate that fully on-device SCG-based cardiac feature extraction is feasible on resource-constrained hardware, enabling energy-efficient, autonomous health monitoring for astronauts in long-duration space missions.
Kazi Mohammad Abidur Rahman, Davis Rakhshan, Philipp Lütke +2
Apr 28, 2026cs.AI

PI-TTA: Physics-Informed Source-Free Test-Time Adaptation for Robust Human Activity Recognition on Mobile Devices

Source-free test-time adaptation (TTA) is appealing for mobile and wearable sensing because it enables on-device personalization from unlabeled test streams without centralizing private data. However, sensor-based human activity recognition (HAR) poses challenges that are less pronounced in standard vision benchmarks: behavioral inertial streams are temporally correlated and often exhibit within-session shifts caused by sensor rotation, placement change, and sampling-rate drift. Under this streaming non-i.i.d. setting, widely used vision-style TTA objectives can become unstable, leading to overconfident errors, representation collapse, and catastrophic forgetting. We propose PI-TTA, a lightweight source-free adaptation framework that stabilizes online updates through three physics-consistent constraints: gravity consistency, short-horizon temporal continuity, and spectral stability. PI-TTA updates the same small parameter subset as strong source-free baselines and incurs only modest overhead, making it suitable for on-device deployment. Experiments on USCHAD, PAMAP2, and mHealth under long-sequence stress tests and factorized shift protocols show that PI-TTA mitigates the severe degradation observed in confidence-driven baselines and preserves stable adaptation under sustained streaming conditions. It improves long-sequence accuracy by up to 9.13% and reduces physical-violation rates by 27.5%, 24.1%, and 45.4% on USCHAD, PAMAP2, and mHealth, respectively. These results demonstrate that physics-informed adaptation can improve accuracy, stability, and deployment reliability for real-world mobile sensing systems.
Changyu Li, Lu Wang, Ming Lei +4
Apr 27, 2026cs.CV

Selective Correlation Based Knowledge Distillation for Ground Reaction Force Estimation

Wearable sensor-based human gait analysis holds great promise in healthcare, rehabilitation, clinical diagnosis and monitoring, and sports activities. Specifically, ground reaction force (GRF) provides essential insights into the body's interaction with the ground during movement and is typically measured using instrumented treadmills equipped with force plates. However, such equipment is expensive and restricted to laboratory environments. To enable a more portable solution, wearable insole sensors have been used to measure GRF. These sensors, however, are prone to noise and external interference, which reduces measurement accuracy. Deep learning methodologies could be adopted to address these issues, but they often require significant computing resources to achieve high accuracy, limiting their applicability for real-time analysis on portable devices. To overcome these limitations, we propose Selective Correlation Based Knowledge Distillation (SCKD) for estimating GRF from data collected by insole sensors. Our proposed method utilizes selected features considering temporal characteristics in the process of extracting correlation maps for knowledge transfer, enhancing interpretability and mitigating issues in high dimensional data processing. We demonstrate the effectiveness of the compact models generated by our distillation framework through comparison with existing methods. Various configurations of teacher-student architectures and training approaches are examined based on multiple evaluation criteria, utilizing data collected at different walking speeds and with different window sizes. Experimental results confirm that our approach outperforms existing methods in estimating GRF from wearable insole sensor data. Therefore, our approach offers a reliable and resource-efficient solution for human gait analysis.
Eun Som Jeon, Jisoo Lee, Huisu Lim +3
Apr 27, 2026cs.CV

An Affordable, Wearable Stereo-Eye-Tracking Platform

Research on video-based eye-tracking has long explored stereo and glint-based methods, yet existing wearable eye trackers - both commercial and open-source - offer limited flexibility for algorithm development and comparative evaluation. We present an affordable, wearable stereo eye-tracking platform built from off-the-shelf and 3D-printable components that explicitly targets this gap. The system combines four infrared eye cameras, infrared illumination, an optional scene camera, and software support for calibration and synchronized data acquisition. By design, the platform supports multiple eye-tracking paradigms, including stereo, glint-based, and binocular approaches, within a single hardware configuration. Rather than optimizing for end-user robustness, the platform prioritizes modularity and extensibility for research use. This paper focuses on the hardware architecture and calibration pipeline and demonstrates the feasibility of the approach using a prototype implementation. All hardware designs and documentation are made openly available.
Alexander Zimmer, Yasmeen Abdrabou, Enkelejda Kasneci
Apr 26, 2026cs.RO

LiDAR for Rehabilitation: A Comprehensive Survey of Applications, AI Techniques, and Future Directions

Rehabilitation aims to help patients with limited mobility regain their physical abilities through targeted movements, exercises, stimulation, and other therapeutic methods. Recent advances in technology have introduced sensor-based systems into rehabilitation and clinical practices, enabling real-time monitoring and providing accurate feedback on movement accuracy. Among these sensors, LiDAR has demonstrated strong potential, offering key advantages over conventional techniques such as camera-based systems, which raise privacy concerns, and wearable sensors, which can be uncomfortable and prone to errors. In this work, we review the applications of LiDAR in rehabilitation, post-injury care, and hospital environments, focusing on studies published between 2019 and 2025. Studies across several areas have been explored: 3D body scanning and gait analysis with standalone LiDAR, LiDAR mounted on robotic systems for rehabilitation, real-time monitoring and environment scanning for safe navigation, and activity and position recognition. We also analyze processing techniques, particularly learning-based approaches, and support the discussion with statistical analysis, highlighting trends, gaps, and future research opportunities. To the best of our knowledge, this is the first comprehensive survey dedicated to LiDAR for rehabilitation applications, providing an overview of current methods, AI-based processing techniques, and open challenges.
Soumia Siyoucef, Najmeddine Dhieb, Hakim Ghazzai +3
Apr 24, 2026eess.SP

An Algorithm for On-Sensor Agnostic Detection of Changes in Human Activity for Ultra-Low-Power Applications

Wearable devices running Human Activity Recognition(HAR) on Inertial Measurement Units~(IMUs) waste energy by performing continuous classification for each window, even during long periods of unchanged activity. We address this with a lightweight change-detection gate: a non-parametric algorithm based on dynamic template matching that runs continuously at only approximately 16kFLOPs per step, requires no offline training, and does not need prior definition of target activity classes. The gate invokes the full HAR network only when it detects an activity change, reducing the computational load by over 67% in realistic monitoring settings. The algorithm is evaluated on smart glasses, smartwatch, and smartphone data, requiring only a brief device-specific calibration phase. The gate achieves 98% sensitivity on UCA-EHAR, ensuring no genuine activity transition is missed, while 75% specificity keeps unnecessary HAR invocations low. Results on WISDM are 97% sensitivity and 76% specificity, demonstrating robustness and flexibility to various settings.
Sara Rimoldi, Arianna De Vecchi, Hazem Hesham Yousef Shalby +1
Apr 23, 2026cs.CV

Seeing Without Eyes: 4D Human-Scene Understanding from Wearable IMUs

Understanding human activities and their surrounding environments typically relies on visual perception, yet cameras pose persistent challenges in privacy, safety, energy efficiency, and scalability. We explore an alternative: 4D perception without vision. Its goal is to reconstruct human motion and 3D scene layouts purely from everyday wearable sensors. For this we introduce IMU-to-4D, a framework that repurposes large language models for non-visual spatiotemporal understanding of human-scene dynamics. IMU-to-4D uses data from a few inertial sensors from earbuds, watches, or smartphones and predicts detailed 4D human motion together with coarse scene structure. Experiments across diverse human-scene datasets show that IMU-to-4D yields more coherent and temporally stable results than SoTA cascaded pipelines, suggesting wearable motion sensors alone can support rich 4D understanding.
Hao-Yu Hsu, Tianhang Cheng, Jing Wen +2
Apr 21, 2026cs.AI

Enhancing Construction Worker Safety in Extreme Heat: A Machine Learning Approach Utilizing Wearable Technology for Predictive Health Analytics

Construction workers are highly vulnerable to heat stress, yet tools that translate real-time physiological data into actionable safety intelligence remain scarce. This study addresses this gap by developing and evaluating deep learning models, specifically a baseline Long Short-Term Memory (LSTM) network and an attention-based LSTM, to predict heat stress among 19 workers in Saudi Arabia. Using Garmin Vivosmart 5 smartwatches to monitor metrics such as heart rate, HRV, and oxygen saturation, the attention-based model outperformed the baseline, achieving 95.40% testing accuracy and significantly reducing false positives and negatives. With precision, recall, and F1 scores of 0.982, this approach not only improves predictive performance but also offers interpretable results suitable for integration into IoT-enabled safety systems and BIM dashboards, advancing proactive, informatics-driven safety management in the construction industry.
Syed Sajid Ullah, Amir Khan
Apr 21, 2026eess.SP

A Hybrid Windkessel-Neural Approach for Improved Noninvasive Blood Pressure Monitoring

Owing to the recent advancements in wearable devices for health care, the importance of BP estimation without cuffs increases. Cuff technologies are inappropriate for continuous BP measurement due to their inconvenient usage, invasive character, necessity of calibration, large size, and inability to perform long-term monitoring. Normally, the algorithm used for cuffless BP prediction employs machine learning models that operate according to the data-driven approach. However, although they show high numerical accuracy, ML models do not provide any interpretability, resulting in poor physiological validity and clinical applicability. We propose a combination of Windkessel and ML models that incorporates the physical aspects into the latter one. It is performed by reformulating Windkessel into a form that will allow employing ML models. The result is a system of ODEs which can be used in the neural network. Thus, the inclusion of physical constraints improves the data-driven approach by making models consistent with physics, understandable, and robust. For illustration, we apply the described technique using a publicly available MIMIC-II database that we obtain from the UCI Machine Learning Repository.
Vaibhav Gollapalli, Aniruth Ananthanarayanan
Apr 20, 2026cs.RO

Will People Enjoy a Robot Trainer? A Case Study with Snoopie the Pacerbot

The physicality of exercise makes the role of athletic trainers unique. Their physical presence allows them to guide a student through a motion, demonstrate an exercise, and give intuitive feedback. Robot quadrupeds are also embodied agents with robust agility and athleticism. In our work, we investigate whether a robot quadruped can serve as an effective and enjoyable personal trainer device. We focus on a case study of interval training for runners: a repetitive, long-horizon task where precision and consistency are important. To meet this challenge, we propose SNOOPIE, an autonomous robot quadruped pacer capable of running interval training exercises tailored to challenge a user's personal abilities. We conduct a set of user experiments that compare the robot trainer to a wearable trainer device--the Apple Watch--to investigate the benefits of a physical embodiment in exercise-based interactions. We demonstrate 60.6% better adherence to a pace schedule and were 45.9% more consistent across their running speeds with the quadruped trainer. Subjective results also showed that participants strongly preferred training with the robot over wearable devices across many qualitative axes, including its ease of use (+56.7%), enjoyability of the interaction (+60.6%), and helpfulness (+39.1%). Additional videos and visualizations can be found on our website: https://sites.google.com/view/snoopie
Maximilian Du, Jennifer Grannen, Shuran Song +1
Apr 20, 2026cs.LG

Towards Real-Time ECG and EMG Modeling on μμNPUs

The miniaturisation of neural processing units (NPUs) and other low-power accelerators has enabled their integration into microcontroller-scale wearable hardware, supporting near-real-time, offline, and privacy-preserving inference. Yet physiological signal analysis has remained infeasible on such hardware; recent Transformer-based models show state-of-the-art performance but are prohibitively large for resource- and power-constrained hardware and incompatible with μμNPUs due to their dynamic attention operations. We introduce PhysioLite, a lightweight, NPU-compatible model architecture and training framework for ECG/EMG signal analysis. Using learnable wavelet filter banks, CPU-offloaded positional encoding, and hardware-aware layer design, PhysioLite reaches performance comparable to state-of-the-art Transformer-based foundation models on ECG and EMG benchmarks, while being <10% of the size (∼\sim370KB with 8-bit quantization). We also profile its component-wise latency and resource consumption on both the MAX78000 and HX6538 WE2 μμNPUs, demonstrating its viability for signal analysis on constrained, battery-powered hardware. We release our model(s) and training framework at: https://github.com/j0shmillar/physiolite.
Josh Millar, Ashok Samraj Thangarajan, Soumyajit Chatterjee +1
Apr 20, 2026cs.LG

Sonata: A Hybrid World Model for Inertial Kinematics under Clinical Data Scarcity

We introduce Sonata, a compact latent world model for six-axis trunk IMU representation learning under clinical data scarcity. Clinical cohorts typically comprise tens to hundreds of patients, making web-scale masked-reconstruction objectives poorly matched to the problem. Sonata is a 3.77 M-parameter hybrid model, pre-trained on a harmonised corpus of nine public datasets (739 subjects, 190k windows) with a latent world-model objective that predicts future state rather than reconstructing raw sensor traces. In a controlled comparison against a matched autoregressive forecasting baseline (MAE) on the same backbone, Sonata yields consistently stronger frozen-probe clinical discrimination, prospective fall-risk prediction, and cross-cohort transfer across a 14-arm evaluation suite, while producing higher-rank, more structured latent representations. At 3.77 M parameters the model is compatible with on-device wearable inference, offering a step toward general kinematic world models for neurological assessment.
Blaise Delaney, Salil Patel, Yuji Xing +3
Apr 17, 2026cs.LG

Continuous ageing trajectory representations for knee-aware lifetime prediction of lithium-ion batteries across heterogeneous dataset

Accurate assessment of lithium-ion battery ageing is challenged by cell-to-cell variability, heterogeneous cycling protocols, and limited transferability of data-driven models across datasets. In particular, robust identification of degradation transitions, such as the knee point, and reliable early-life prediction of remaining useful life (RUL) remain open problems. This study proposes a unified framework for battery ageing analysis based on continuous representations of voltage-capacity and capacity-cycle trajectories learned from heterogeneous public datasets (NASA, CALCE, ISU-ILCC). The continuous formulation enables consistent extraction of degradation descriptors, including curvature, plateau length and knee-related metrics, while reducing sensitivity to dataset-specific discretisation. Across more than 250 cells, statistically significant correlations between knee onset and end-of-life (Pearson 0.75-0.84) are observed. Additional early-life analysis confirms that knee-related features retain predictive value when estimated from partial trajectories. Early-life models provide increasingly stable RUL predictions as the number of observed cycles increases, with meaningful predictive performance emerging within the first 5-20 cycles and remain robust under cross-dataset domain shift. The framework integrates continuous modelling, feature extraction and uncertainty-aware prediction, providing an interpretable and dataset-consistent approach demonstrating robustness across heterogeneous dataset types. Compared with conventional discrete or feature-based methods, the proposed representation reduces sensitivity to sampling resolution and improves cross-dataset consistency. The study is limited to laboratory-scale datasets and capacity-based end-of-life definitions.
Agnieszka Pregowska, Stefan Marynowicz
Apr 16, 2026cs.NI

A Q-learning-based QoS-aware multipath routing protocol in IoMT-based wireless body area network

The Internet of Medical Things (IoMT) enables intelligent healthcare services but faces challenges such as dynamic topology, energy constraints, and diverse QoS requirements. This paper proposes QQMR, a Q-learning-based QoS-aware multipath routing method for WBANs. QQMR classifies data into three priority levels and employs adaptive multi-level queuing and fuzzy C-means clustering to optimize routing decisions. It maintains separate learning policies for each data type and selects primary and backup paths accordingly. Experimental results demonstrate improved packet delivery ratio and significant reductions in delay, routing overhead, and energy consumption compared to existing methods.
Mehdi Hosseinzadeh, Roohallah Alizadehsani, Amin Beheshti +7
Apr 16, 2026cs.AI

Personalized and Context-Aware Transformer Models for Predicting Post-Intervention Physiological Responses from Wearable Sensor Data

Consumer wearables enable continuous measurement of physiological data related to stress and recovery, but turning these streams into actionable, personalized stress-management recommendations remains a challenge. In practice, users often do not know how a given intervention, defined as an activity intended to reduce stress, will affect heart rate (HR), heart rate variability (HRV), or inter-beat intervals (BBI) over the next 15 to 120 minutes. We present a framework that predicts post-intervention trajectories and the direction of change for these physiological indicators across time windows. Our methodology combines a Transformer model for multi-horizon trajectories of percent change relative to a pre-intervention baseline, direction-of-change calls (positive, negative, or neutral) at each horizon, and an empirical study using wearable sensor data overlaid with user-tagged events and interventions. This proof of concept shows that personalized post-intervention prediction is feasible. We encourage future integration into stress-management tools for personalized intervention recommendations tailored to each person's day following further validation in larger studies and, where applicable, appropriate regulatory review.
Esther Brown, Victoria Dean, Finale Doshi-Velez
Apr 16, 2026cs.AI

An AI Co-Data-Scientist for Prioritizing Candidate Biomarkers from Wearable Sensor Data

Wearable devices generate continuous physiological and behavioral data, but converting these signals into clinically reviewable biomarker hypotheses remains labor-intensive. We introduce CoDaS, an AI co-data-scientist that integrates multi-agent hypothesis generation, deterministic statistical analysis, adversarial validation and literature-grounded interpretation under human oversight. Across three wearable cohorts comprising 9,279 participant-observations, CoDaS prioritized candidate associations for mental-health and metabolic endpoints after internal checks for replication, stability, robustness and leakage. The system identified related circadian-instability signals associated with depression, including sleep-duration variability in DWB (ρρ = 0.252, pp < 0.001) and sleep-onset variability in GLOBEM (ρρ = 0.126, pp < 0.001), and derived a wearable cardiovascular-fitness index associated with insulin resistance (steps/resting heart rate; ρρ = -0.374, pp < 0.001). Adding these features to demographic models produced modest gains (ΔR2ΔR^2 = 0.040 for depression, 0.021 for insulin resistance). In a 12-clinician review totaling approximately 25 active hours, clinician validity judgments aligned with CoDaS confidence tiers (ρρ = 0.67, pp = 0.005), whereas added clinical value and confidence to act were rated lower. CoDaS supports traceable, hypothesis-generating prioritization of wearable candidate biomarkers.
Yubin Kim, Salman Rahman, Samuel Schmidgall +33
Apr 7, 2026eess.AS

Active noise cancellation on open-ear smart glasses

Active noise cancellation (ANC) is widely deployed on consumer headphones and earbuds to suppress environmental noise. However, existing ANC systems require an error microphone at the user's ear canal to measure residual sound, preventing deployment on emerging open-ear wearable devices such as smart glasses and VR headsets, which leave the ear unoccluded. Here we present an ANC system for open-ear wearables that suppresses environmental noise using only microphones and miniaturized open-ear speakers embedded within the frame of the wearables, removing the need for an in-ear error microphone. Our low-latency computational pipeline uses a neural network to estimate the noise at the ear from an array of eight microphones distributed around the wearable's frame and generates an anti-noise signal in real-time. This mapping generalizes to unseen users and acoustic environments without prior acoustic measurement. We develop a custom glasses prototype and evaluate across eleven unseen users and eight unseen environments under mobility in the 100 to 1000 Hz frequency range, where environmental noise is concentrated. We achieve a mean noise reduction of 9.6 dB without any calibration, and 11.2 dB with a brief user-specific calibration. Further, we demonstrate that our approach extends to the broader class of open-ear wearables including VR headsets and headbands.
Kuang Yuan, Freddy Yifei Liu, Tong Xiao +5
Jan 7, 2026cs.LG

Lightweight Test-Time Adaptation for EMG-Based Gesture Recognition

Reliable long-term decoding of gestures from surface electromyography (EMG) is hindered by signal drift caused by electrode displacement, muscle fatigue, and/or posture changes. Although modern models achieve high intra-session accuracy, their performance often degrades substantially across recording sessions. Existing approaches to mitigate this problem typically rely on large training datasets or computationally intensive pipelines that are unsuitable for energy-efficient wearable devices. We propose a lightweight test-time adaptation framework for EMG decoding. The framework includes three complementary adaptation strategies: (i) causal adaptive batch normalization for online statistical alignment, (ii) Gaussian Mixture Model alignment with experience replay to mitigate forgetting, and (iii) meta-learning for rapid few-shot calibration. We evaluate these methods on the multi-session NinaPro DB6 dataset. All approaches substantially improve inter-session robustness relative to a non-adaptive baseline while maintaining low computational overhead. Replay-regularized statistical alignment provides the most stable adaptation under limited data, while meta-learning achieves the highest accuracy when sparse calibration labels are available. Overall, our self-supervised test-time adaptation methods reach up to 82% inter-session accuracy, significantly improving upon prior approaches while maintaining resource-efficient operation. These results demonstrate that lightweight test-time adaptation can enable robust, long-term EMG decoding for wearable or prosthetic applications.
Nia Touko, Matthew O A Ellis, Cristiano Capone +3
Aug 6, 2025eess.SP

Energy-Efficient Real-Time 4-Stage Sleep Classification at 10-Second Resolution

Sleep stage classification is critical for diagnosing and managing disorders like sleep apnea and insomnia. However, conventional methods like polysomnography are costly and impractical for long-term, home-based monitoring. This study presents an energy-efficient approach for detecting four sleep stages (wake, rapid eye movement (REM), light sleep, deep sleep) using a single-lead electrocardiogram (ECG) signal. We evaluate various machine learning and deep learning models, introducing two windowing strategies: (1) a 5-minute window with 30-second steps for machine learning and (2) a 30-second window with 10-second steps for deep learning, enabling 10-second temporal resolution for real-time predictions. While deep learning models like MobileNet-v1 achieve high accuracy (92%) and F1-score (91%), their energy demands make them unsuitable for wearables. To address this, we design SleepLiteCNN, optimized for ECG-based sleep staging, achieving 89% accuracy and 89% F1-score while minimizing energy use. Applying 8-bit quantization further reduces energy consumption to 5.48 microJ per inference, with 90% accuracy and F1-score. Additionally, field-programmable gate array (FPGA) deployment shows significant reductions in resource usage. This approach provides a practical, energy-efficient solution for continuous ECG-based sleep monitoring in resource-constrained wearable devices.
Zahra Mohammadi, Parnian Fazel, Siamak Mohammadi
Feb 3, 2025cs.LG

A Wearable Device Dataset for Mental Health Assessment Using Laser Doppler Flowmetry and Fluorescence Spectroscopy Sensors

Mental health problems such as stress, anxiety, and depression affect millions of people worldwide. These conditions are usually assessed using questionnaires, which rely on how people describe their own feelings. In this study, we explore whether a wearable device can help measure mental health using physical signals from the body. The device records small changes in blood flow and tissue activity from the fingertip. We collected data from 132 adults across 19 countries and compared these signals with mental health questionnaire results. We found that patterns in blood flow and tissue activity are linked to stress-related symptoms. This approach may help develop new tools for simple, non-invasive mental health monitoring in everyday life. Code and datasets are publicly available: https://github.com/leduckhai/Wearable_LDF-FS
Minh Ngoc Nguyen, Khai Le-Duc, Tan-Hanh Pham +7
Jun 11, 2024cs.HC

Wearable Device-Based Real-Time Monitoring of Physiological Signals: Evaluating Cognitive Load Across Different Tasks

This study employs cutting-edge wearable monitoring technology to conduct high-precision, high-temporal-resolution (1-second interval) cognitive load assessment on electroencephalogram (EEG) data from the FP1 channel and heart rate variability (HRV) data of secondary vocational students. By jointly analyzing these two critical physiological indicators, the research delves into their application value in assessing cognitive load among secondary vocational students and their utility across various tasks. The study designed two experiments to validate the efficacy of the proposed approach: Initially, a random forest classification model, developed using the N-BACK task, enabled the precise decoding of physiological signal characteristics in secondary vocational students under different levels of cognitive load, achieving a classification accuracy of 97%. Subsequently, this classification model was applied in a cross-task experiment involving the National Computer Rank Examination (Level-1), demonstrating the method's significant applicability and cross-task transferability in diverse learning contexts. Conducted with high portability, this research holds substantial theoretical and practical significance for optimizing teaching resource allocation in secondary vocational education, as well as for cognitive load assessment methods and monitoring. Currently, the research findings are undergoing trial implementation in the school.
Ling He, Yanxin Chen, Wenqi Wang +2
Date pendingcs.CV

Ambient @ EgoProactive 2026 : Proactive Egocentric Assistance with Visually Grounded Supervision

We present our submission to the EgoProactive track of the ECCV 2026 Wearable AI Challenge, which ranked first in the large-model division and second in the <=2B division. The task requires a wearable assistant to decide after each eight-second segment of egocentric video whether to intervene or remain silent. Our approach has two main components. First, we reformulate intervention timing as single-token classification. Rather than generating either interruptinterrupt<utterance> or silentsilent, the model predicts yes or no, and we derive the decision from the renormalised probabilities of these two tokens. This formulation improved macro-F1 by 0.249 and G-mean by 0.30 over free-form generation. Second, because labelled data were limited to the released validation set, we generated additional supervision using a tool-calling video agent that inspects each clip and assigns intervention timestamps. A narration-only alternative was four times larger and ten times cheaper, but transferred worse than supervision from an unrelated real corpus, suggesting that visual grounding is more important than annotation volume for this task.
Logesh Kumar Umapathi
Date pendingcs.CV

Ambient @ EgoLongQA 2026: Distilling Long-Video perception into a Sub-2B Model

We describe our entry to the EgoLongQA track of the Wearable-AI Challenge in ECCV 2026, which placed first in the <=2B parameter division with 0.8279 on the held-out test set. Our system is a single 2B vision-language model that answers multiple-choice questions about ten-minute egocentric videos in one greedy forward pass; It is obtained by distilling the junior perception module of a tool-using agentic pipeline, not the agent itself into a small student, using teacher traces filtered to those that answered correctly. it reaches 89% of the accuracy of the large agentic pipeline using 1.1% of its parameters. This raises a 27.1% base model to 81.4% on our held-out questions. The 2B backbone has 2.2132B parameters and therefore over the divisional limit, to make the entry admissable we prune the multilingual embedding table from 248,320 to 143,469 rows, reaching 1.9985B with provably identical logits on retained rows.
Logesh Kumar Umapathi