Gradient Surgery

Recent momentum

emerging

0 papers in the last 28 days · 0.0% of indexed attention

Twelve weeks of publication activity for this topic as it is defined today.

Weekly history

Recent digests

What was published in this field, kept on the site without email delivery.

Period ending 2026-09-21

4 new papers

A weekly snapshot of new work published in Gradient Surgery.

Period ending 2026-09-14

5 new papers

A weekly snapshot of new work published in Gradient Surgery.

Period ending 2026-09-07

3 new papers

A weekly snapshot of new work published in Gradient Surgery.

Inside this field

Focused directions

183 papers

Latest in Gradient Surgery

Jun 3, 2026cs.CV

What neurosurgeons need to see: synthetic intra-operative MRI from ultrasound for brain-shift compensation in brain tumour surgery

Maximal safe resection is the primary objective in glioma surgery. Neuronavigation guidance is progressively degraded by brain shift after dural opening. Intraoperative MRI can compensate but needs dedicated infrastructure and is rarely available, whereas intraoperative ultrasound (ioUS) is inexpensive, repeatable, and compatible with routine workflows. Navigation systems combining ioUS with preoperative MRI usually rely on rigid registration; even deformable multimodal registration is limited by ultrasound speckle contrast, a narrow field of view, and the inability to represent structures absent from the preoperative scan, most critically the resection cavity and residual tumor. We propose an end-to-end pipeline that generates a new whole-brain MRI volume in the preoperative imaging space by merging the preoperative MRI, a synthetic MRI generated from the ioUS, and a deformable registration anchored on that synthetic image. It integrates a 2.5D residual-transformer synthesis backbone (ResViT-2.5D) and a two-stage registration coupling NiftyReg with a synthesis-anchored SynthMorph stage, operating directly on raw scanner inputs. On a post-resection ReMIND cohort, ResViT-2.5D produced synthetic images closely matching the intraoperative T2 across structural, intensity, and perceptual metrics. In 14 subjects with 215 expert landmarks, the synthesis-anchored registration reduced the mean target registration error from 6.27 to 5.86 mm, matching a strong classical NiftyReg baseline (5.85 mm) while yielding a diffeomorphic deformation field in every subject. The contribution is not a gain in registration accuracy but the integrated volume itself, which inside the ultrasound field of view it reflects the intraoperative post-resection state. This provides the surgeon with an MRI-like update of the operative field with potential for integration into surgical-navigation workflows.
Santiago Cepeda, Olga Esteban-Sinovas, Ignacio Arrese +1
Jun 1, 2026eess.IV

Predicting the risk of colorectal anastomotic leak based on preoperative mapping of the blood supply of the bowel

Anastomotic leak remains one of the most serious complications following colorectal cancer surgery, substantially affecting patient outcomes, recovery trajectories, and healthcare costs. Despite advances in imaging technology, current preoperative assessment relies only on clinical assessment, a process that is subjective, error-prone, and highly dependent on individual expertise. To date, no validated CT-based method exists to predict anastomotic leak risk prior to surgery. This protocol paper outlines a comprehensive framework for developing and validating an AI-driven system for preoperative risk assessment using pre- and post-contrast CT imaging. The study describes the stages of data collection, ethical handling, and preprocessing of patient data in accordance with GDPR, image preprocessing, and the exploration of deep learning architectures designed to generate clinically interpretable outputs. Two integrated tools constitute the main deliverables of this workflow: 1) a risk assessment module, which quantifies the likelihood of leakage by analyzing vascular and tissue features in CT scans, and 2) a Content-Based Medical Image Retrieval (CBMIR) module, which identifies and displays similar historical cases to support evidence-based surgical decision making. The protocol paper requires close collaboration between hospitals and universities; this protocol demonstrates that such a system is technically feasible and clinically implementable within existing healthcare infrastructures. By following the proposed methodological stages and regulatory principles, other institutions can reproduce this workflow to develop analogous decision-support tools. Ultimately, this interdisciplinary framework aims to enhance surgical planning, reduce leak incidence, and contribute to a broader paradigm shift toward explainable, data-driven precision surgery.
Zahra Tabatabaei, Jon Sporring, Mark Bremholm Ellebæk +1
May 29, 2026cs.RO

Shaft-integrated Force Sensing with Transformer-based Dynamics Compensation for Telesurgery

Robot-Assisted Minimally Invasive Surgery (RAMIS) enhances surgeon dexterity, with newer platforms leveraging haptic feedback to further improve performance. Such force information has broader potential to inform performance assessment, tactile localization, and surgical autonomy. This motivates the need for accessible approaches to integrating force sensing into RAMIS tools. This work presents a method for integrating a six-axis commercial force sensor into the distal end of a standard cable-driven surgical instrument, enabling end-effector force measurement while preserving the original mechanical functionality of the device. The proposed design emphasizes reproducibility and accessibility for research applications, requiring no specialized manufacturing tools. A transformer neural network integrates force sensor measurements with robot state information to aid estimation of applied forces at the end-effector, compensating for internal cable forces arising from actuation. Our proposed approach achieved normalized errors below 6%, and generalized to unseen conditions better than purely proximal data-driven sensing approaches. High internal cable forces caused sensor saturation and reduced axial force observability, which can degrade performance along the tool's major axis and under higher load conditions. Given current levels of performance, the balance of system integrability and performance enables applications and research into timely topics of haptic feedback, skill assessment, and force-informed autonomy in RAMIS. Videos and code are available at https://enhanced-telerobotics.github.io/shaft_force_sensing/.
Shuyuan Yang, Grant Boone, Timo Markert +4
May 28, 2026cs.CV

DefSynUS: Real-time Patient-specific Intrahepatic Vessel Identification via Deformation-Aware CT-US Domain Adaptation

Purpose: Laparoscopic ultrasound (LUS) enhances the safety of liver surgery by visualizing intrahepatic vessels in real-time. Still, vessel identification remains difficult due to probe constraints, complex vascular structure, and tissue deformation. This work aims to enable real-time, patient-specific vessel identification that remains robust under deformation through deformable ultrasound augmentation. Methods: Preoperative CT vessel annotations are used to generate synthetic ultrasound data via optimized physics-based rendering, coupled with domain adaptation to intraoperative ultrasound. The rendering is trained end-to-end for vessel identification and patient-specificity, eliminating the need for preoperative ultrasound. A deformation-aware augmentation simulates realistic intraoperative motion and tissue deformation within the rendering pipeline. Results: In abdominal phantom and limited clinical feasibility experiments (single-case clinical evaluation), the framework achieved real-time intrahepatic vessel-branch identification, maintaining performance under new patient poses. Conclusion: The framework enables real-time vessel identification without preoperative ultrasound and supports technical feasibility, but multi-patient validation is still needed for generalizability and clinical feasibility.
Karl-Philippe Beaudet, Yordanka Velikova, Sidaty El Hadramy +4
May 27, 2026cs.RO

Imitation Learning for Robot Assistance in Open Surgery: A Multi-Policy Evaluation on Suture Following

This study presents the first evaluation of general-purpose imitation learning for surgeon-robot collaborative assistance in open surgery, targeting suture following: the grab-pull-release motion an assistant performs at every stitch. We collect 160 teleoperated demonstrations (32,374 frames) on an open-source robot arm, benchmark four architecturally diverse imitation learning policies (ACT, Diffusion Policy, SmolVLA, π0π_0) across 28 trained models evaluated in 32 configurations along three clinically motivated dimensions: dataset size, camera viewpoint, and background variation. Our results demonstrate that under ideal conditions, the four policies achieve 5050-75%75\% task success, with depth error as the dominant failure mode across all architectures. Among all policies, π0π_0 achieves the strongest results with a pretrained vision-language backbone, demonstrating superior data efficiency, greater robustness to background variation, and smoother trajectories compatible with surgical workflow. When deployed in a surgeon-robot suturing trial, π0π_0 yields a 92%92\% stitch completion rate. These findings establish collaborative robotic assistance in open surgery as a feasible target for imitation learning and highlight depth perception and end-effector design as key priorities for clinical translation.
Xucheng Wang, Zhizhou Yang, Xiaoman Zhang +3
May 27, 2026cs.CV

VDSB-GWSyn: Diffusion Schrödinger Bridge for Controllable and Anatomically Feasible Guidewire Synthesis in Coronary Angiography

Coronary guidewire endpoint localization is a fundamental capability for computer-assisted PCI, and its importance increases as robot-assisted PCI is progressively adopted to reduce operator radiation exposure. However, the scarcity of annotated CAG images with guidewires and the limited adaptability of existing guidewire synthesis models remain key bottlenecks for guidewire endpoint localization. To address this issue, we propose VDSB-GWSyn, a Diffusion Schrödinger Bridge (DSB) model-based framework, enabling synthesis of controllable, high-fidelity guidewire samples under complex anatomical backgrounds. VDSB-GWSyn first uses our shape prior algorithm to learn the basic guidewire geometry. It then generates guidewire masks under constraints imposed by the vessel segmentation masks and outputs the corresponding endpoint coordinates. Finally, it synthesizes realistic guidewire samples on real CAG images using DSB conditioned with SPADE. Experimental results show that the guidewire samples synthesized by VDSB-GWSyn achieve favorable ROI-FID and ROI-KID, as well as high IPR scores. In addition, incorporating our synthesized data for synthetic pre-training followed by real fine-tuning substantially improves downstream guidewire endpoint localization, reducing MPE from 16.01px to 7.71px and increasing PCK at 3~px from 52.63% to 86.27%, leading to more clinically reliable deployment of robot-assisted guidewire delivery systems. Moreover, the core design philosophy of controllable device synthesis with strict background preservation and anatomical feasibility constraints has the potential to transfer to other interventional device perception tasks where annotated data are scarce.
Haoyuan Tang, Zhuo Zhang, Jialin Li +2
May 26, 2026cs.CV

Attenuation-Resilient Alternating Optimization for Laparoscopic Liver Landmark Detection

Liver surface landmark detection is a fundamental prerequisite for anatomical guidance in laparoscopic liver surgery. However, it remains unreliable in practice due to two pervasive challenges: illumination attenuation in underexposed regions and the structural mismatch between pixel-wise localization and continuous curvilinear geometry. To address these limitations, we propose A2ONet, an attenuation-resilient alternating optimization network for robust liver landmark detection. To mitigate illumination attenuation, A2ONet embraces an illumination field compensation (IFC) block that adaptively enhances dark regions while preserving structural consistency. Meanwhile, we introduce a lightweight frequency-orientation selective filter (FOSF) to suppress repetitive texture interference and preserve salient curvilinear cues. Building upon these resilient representations, we design an alternating seg-curve optimization (ASCO) decoder that iteratively couples dense segmentation with explicit curve modeling, enabling mutual guidance to optimize both structural continuity and endpoint localization. Extensive evaluations on L3D-2K, L3D, and P2ILF demonstrate consistent improvements over competitive methods, establishing a more reliable foundation for intraoperative anatomy guidance. Our code will be available at https://github.com/hyperiondk115/A2ONet.
Lanqing Liu, Ruize Cui, Jialun Pei +4
May 25, 2026cs.CV

SurfSurg6D: Geometry Consistent Dense Correspondence for Textureless Surgical Instrument Pose Estimation

Surgical instrument pose estimation provides crucial information for promising applications, including autonomous robotic surgery, skill assessment, and standardization of surgical workflow. However, this task remains highly challenging due to high precision requirements, frequent occlusions, textureless instruments, scarcity of depth information and very limited annotated data. These constraints often lead to unsatisfactory performance when employing general object pose estimation approaches to surgical scenarios. To address these issues, we first construct a new dataset SynSurg6D, to alleviate the data shortage in this task. We further propose SurfSurg6D, a dense-correspondence framework tailored for surgical instrument pose estimation. Experimental results on the SurgRIPE, EndoVis2018 and SurgPose datasets demonstrate that the introduction of our generated dataset SynSurg6D is able to diversify the pose distributions, thus enhancing the performance of existing approaches. Furthermore, SurfSurg6D outperforms existing methods, providing a robust solution for precise and efficient RGB-only pose estimation.
Daiyun Shen, Shuojue Yang, Chang Han Low +4
May 25, 2026cs.CL

A Multi-Agent LLM Framework for Rating the Quality of Surgical Feedback

Verbal feedback delivered by attending surgeons in the operating room plays a critical formative role in resident trainee skill acquisition. Yet, assessing the quality of trainer feedback and its effectiveness in influencing trainee behavior during live surgery remains a challenge. Prior studies assessed feedback content relying on extensive manual annotation by expert human raters and focused on developing broad taxonomies that overlook the qualitative aspects of feedback delivery such as clarity or urgency. Limited existing automated methods, including keyword analysis and topic modeling, also fail to capture these nuanced aspects. We introduce a two-stage LLM-based framework that discovers interpretable feedback quality criteria grounded in the context of surgical training. Our method uses multi-agent prompting and surgical domain knowledge injection to discover a small set of human interpretable scoring criteria (e.g., Encouraging, Urgent, Clear). These criteria are then used to automatically score live surgical feedback via an LLM-as-a-judge approach. Evaluation on 4.2k trainer feedback instances demonstrates that our AI-discovered criteria outperform prior content-based frameworks in predicting feedback effectiveness, including observed trainee behavioral adjustments and trainer approval. This work advances scalable, human-aligned assessment of communication quality in the operating room and provides a foundation for improving surgical teaching practices.
Rafal Kocielnik, J. Everett Knudsen, Steven Y. Cen +7
May 24, 2026cs.RO

Stiffness Optimization for Concentrated Bending in Magnetically Actuated Catheters: Maintaining Steerability under Gradient Stiffness

Achieving both efficient pushability (propulsion transmission) and proximally concentrated bending for steerability is challenging for magnetically actuated soft catheters: higher axial/bending stiffness improves force transmission but reduces steerability, whereas lower stiffness enables large, proximally concentrated bending yet increases kinking/buckling risk under compressive push loads. To address this trade-off, we propose a stiffness-optimized multi-segment magnetically actuated catheter (SO-MAC) that integrates a decoupled steering-advancement mechanism with a gradient-stiffness architecture. The SO-MAC concentrates bending about a stable proximal pivot during advancement while the distal section passively self-straightens to transmit propulsion, aided by the optimized stiffness distribution and elastic recovery of the spring backbone against friction-induced kinking/buckling. Over 01800{-}180^{\circ} combined steering and advancement, the pivot remained stable and the distal tip advanced near-straight toward the target direction. A 1.5 mm-diameter SO-MAC achieved up to 180180^{\circ} steering with a 3 mm bending radius at its 10 mm tip, with an average shape error of 1.39±0.561.39 \pm 0.56 mm and a steering-pivot error of 0.35±0.100.35 \pm 0.10 mm. Visual feedback control in a bronchial phantom further confirmed robust navigation through highly curved, bifurcating paths.
Jiewen Tan, Junnan Xue, Shing Shin Cheng +3
May 23, 2026cs.RO

Geometric Workspace Analysis and Transmission-Aware Dynamics of a Serial Spherical Tool for Microsurgery

We present a kinematic and transmission-aware design framework for a serial spherical mechanism with an additional translational degree of freedom for microsurgery. The first contribution is an analytical workspace formulation that provides geometric insight into reachable motion and enables rapid selection of rotation axis orientations without numerical optimization. The second contribution is a dynamics-informed methodology for mechanisms driven by self-locking transmissions, supporting evaluation of torque requirements for a prescribed workspace geometry. The framework is accompanied by an open-source software package for friction identification and inverse dynamics analysis. Experiments on a purpose-built robotic tool for vitreoretinal surgery validate the predictive capability of the models and demonstrate their practical utility for engineering design.
Anestis Mablekos-Alexiou, Lyndon da Cruz, Christos Bergeles
May 22, 2026cs.CV

ExpOS: Explainable Open-Surgery Skills Assessment Using 3D Hand Reconstruction

Timely and transparent feedback is essential for effective surgical training, yet current assessment remains dependent on expert observation, limiting scalability and opportunities for autonomous practice. We present ExpOS, an explainable framework for data-driven assessment of open-surgery skills designed to enable automatic, feedback-oriented evaluation. Rather than relying on expert-defined metrics, ExpOS learns discriminative temporal patterns directly from motion data and identifies the segments and behaviors most predictive of skill level. We trained and evaluated the method on 221 videos of medical students performing three open-surgery tasks. Hand poses and tool detections were extracted from each frame to derive kinematic descriptors and global motion statistics. Spatiotemporal hand-tool dynamics were modeled using a temporal convolutional backbone with attention-based pooling to generate frame-level importance maps. These representations were fused with global motion statistics to predict skill level and to provide interpretable feedback. ExpOS provides multi-level explainability by identifying when informative events occur through attention weights and which motion characteristics most influence predictions through global feature analysis. Across tasks, the framework achieved strong correlation with expert ratings, with best performance on fascial closure (r = 0.778, R2 = 0.74). These results demonstrate that combining weakly-supervised temporal importance learning with interpretable motion statistics enables scalable and actionable surgical skill assessment.
Roi Papo, Idan Smoller, Shlomi Laufer
May 21, 2026cs.CV

RoboSurg-VQA: A Multimodal Benchmark for Surgical Segmentation-Aware Visual Question Answering

Reliable visual understanding in robot-assisted and minimally invasive surgery (RMIS/MIS) demands more than accurate masks: in clinical practice, clinicians pose language-like questions about procedural context, visibility, artefacts, and the presence of anatomical structures and surgical instruments, often under degraded views caused by occlusion, smoke, bleeding, and specular highlights. We present \textbf{RoboSurg-VQA}, a segmentation-aware visual question answering (VQA) benchmark built by repurposing public surgical segmentation datasets under a shared schema. Each frame is paired with a fixed set of clinically motivated questions spanning procedure context, anatomy (including region), imaging modality/view, surgical artefacts, image quality, and basic visibility and spatial attributes, with closed answer sets to enable consistent evaluation. To scale annotation, we generate candidate answers via constrained prompting with automatic validity and consistency checks, followed by human auditing to improve plausibility and label consistency. We report benchmark statistics, sanity baselines, and common evaluation challenges under challenging surgical conditions. The code will be available on https://github.com/ziyangwang007/Robosurg-VQA.
Chengyi Zhang, Zi Ye, Ziyang Wang
May 21, 2026cs.RO

How can reasoning capability empower the AI copilot robot in endoscopic surgery

Reasoning capability has significantly advanced complex logical inference and robotic decision-making in general domains. However, its potential in the Artificial Intelligence (AI) copilot robot-particularly implemented based on the Vision-Language-Action (VLA) model-remains unexplored in endoscopic surgery. Effective reasoning should enable AI copilot robots to integrate multimodal cues, interpret surgical intent, and infer hidden tissue dynamics, thereby alleviating intraoperative uncertainty and cognitive burden on surgeons. Properly implemented, reasoning-driven autonomy can transform AI copilot robots from reactive executors into cognitive collaborators, enhancing precision, safety, and sustainability in clinical practice.
Guankun Wang, Long Bai, Hongliang Ren
May 21, 2026cs.RO

Remote Teleoperation of Endovascular Intervention Robots: A Systematic Review

Remote robotic-assisted endovascular intervention offers a promising approach to reduce clinician radiation exposure and physical strain, while extending specialized vascular care to geographically distant regions. Despite advancements, teleoperated endovascular intervention remains underexplored, especially for time-sensitive interventions like mechanical thrombectomy for acute stroke. The aim of the current review was to determine the evidence regarding teleoperated endovascular robotic systems, covering technical feasibility, communication infrastructure, and clinical outcomes. The review further identified research gaps and future directions. Following PRISMA guidelines, 16 studies were included that met the inclusion criteria out of 2501 initial search results. We found that teleoperated catheters and guidewires, driven by mechanical or electromagnetic systems, can be navigated across distances up to 7000 km. With robust communication infrastructure, network latency remained within clinically acceptable limits (30-163 ms). Although initial outcomes highlighted 100% procedural success in small-scale human trials, most evidence stemmed from animal or phantom models. Overall, the findings suggest that teleoperated endovascular intervention can reduce occupational hazards, expand patient access to urgent procedures, and optimize resource allocation. Future research should be conducted in low and middle income countries to demonstrate broader geographical access. Ultimately, multi-center clinical trials are required to validate the safety, efficacy, and generalization in diverse clinical settings.
Xingyu Chen, Yinchao Yang, Nikola Fischer +5
May 21, 2026cs.CV

OSS: Open Suturing Skills Vision-Based Assessment Challenge 2024-2025

Achieving high levels of surgical skill through effective training is essential for optimal patient outcomes. Automated, data-driven skill assessment holds significant potential to improve surgical training. While machine learning-based methods are increasingly popular for assessing skills in minimally invasive surgery, their application to open surgery remains limited. We present the results of a dedicated MICCAI challenge designed to benchmark and advance vision-based skill assessment in open surgery. The challenge dataset comprises videos of an open suturing training task recorded with a static GoPro camera in a dry-lab setting, with instrument trajectories available in addition to the primary video modality. The OSS Challenge was hosted over two consecutive years, comprising two and three independent tasks, respectively: (1) classifying skill level into four classes, (2) predicting the full Objective Structured Assessment of Technical Skills across eight categories, and (3) tracking hands and surgical tools. Participants submitted diverse solutions including deep learning-based video models, tracking-driven methods, and hybrid approaches. General-purpose spatiotemporal video models consistently achieved the strongest performance, though conceptually diverse approaches reached competitive levels when well-executed. Predicting fine-grained OSATS scores remains challenging but benefits substantially from increased training data. Keypoint tracking proves difficult given frequent occlusions and out-of-frame instances, limiting current applicability for motion-based skill analysis. This work benchmarks innovative and diverse solutions for surgical skill assessment, highlighting both the promise and current limitations of video-based evaluation in open surgery and identifying critical directions for advancing automated skill assessment toward clinical impact.
Hanna Hoffmann, Setareh Bady, Claas de Boer +54
May 20, 2026cs.CV

SurgOnAir: Hierarchy-Aware Real-Time Surgical Video Commentary

Understanding surgical workflow in real time is fundamental for intelligent surgical embodiment, where AI systems continuously perceive and respond as surgery proceeds. In the operating room, critical decisions depend on subtle, moment-to-moment changes, such as fine instrument movements and evolving tissue states, where even slight perceptual delays can limit assistance or compromise safety. Yet existing methods remain offline or operate at coarse temporal scales, generating descriptions only after processing clips, preventing immediate reaction. We address this by proposing SurgOnAir, a streaming vision-language model that processes frames sequentially without future access and progressively generates narration tokens as visual input arrives. SurgOnAir achieves fine-grained frame-to-token generation, enabling instant responsiveness to evolving surgical dynamics. Built upon our curated hierarchical dataset SurgOnAir-11k spanning action-, step-, and phase-level supervision, the model is trained to produce multi-level textual responses that reflect the inherent hierarchy of surgical procedures. Furthermore, special transition tokens are generated to explicitly mark state changes, allowing SurgOnAir to capture and signal key workflow transitions as they occur. Experiments show that SurgOnAir enables real-time understanding through a single vision-language model that unifies streaming across multiple hierarchies of the surgical workflow, generating superior and hierarchy-aware narrations. Code and dataset will be public.
Jingyi He, Yue Zhou, Long Bai +3
May 18, 2026cs.RO

Learning-Based Adaptive Control for Surgical Robotic Exposure Task on Deformable Tissues

In various surgical procedures, regions of interest (ROIs) such as organs or lesions are often occluded by overlying tissues, requiring surgeons to achieve adequate exposure for precise intervention. However, the irregular geometry, nonlinear biomechanical properties of overlying tissues, and limited intraoperative visibility of the ROI pose significant challenges to the autonomous execution of tissue retraction. To address this, we formulate a realistic model of the tissue retraction task and propose a learning-based adaptive control framework for achieving ROI exposure. The method optimizes control inputs online by monitoring changes in the visual boundary of the tissue, while leveraging a deep deformation estimation model trained on simulation data to identify the optimal grasping point and ensure the convergence and safety of the adaptive controller. Through simulations and real-world experiments on different deformable materials, it has been demonstrated that this framework exhibits zero-shot adaptation to similar tasks and can complete the autonomous retraction process, from initial grasp selection to full ROI exposure. Therefore, it has the potential to be applied in actual surgical assistance scenarios.
Jiayi Liu, Kaiqi Wei, Yiwei Wang +2
May 18, 2026cs.CV

SurgLQA: Scalable Long-Horizon Surgical Video Question Answering

Surgical Video Question Answering (VideoQA) provides a promising paradigm for dynamic intraoperative interpretation, enabling real-time decision support and context-aware retrieval in clinical environments. Nevertheless, existing approaches are predominantly restricted to images or short clips, limiting their ability to model long-range procedural dynamics and causal dependencies across extended surgical workflows. To address this challenge, we propose SurgLQA, a unified long-horizon VideoQA framework for scalable surgical reasoning. This framework incorporates Faithful Temporal Consolidation (FTC), which leverages intrinsic temporal cues to construct compact long-range representations while preserving fine-grained temporal fidelity. Further, we develop Temporally-Grounded Multi-Policy Scaling (TMS), an adaptive test-time inference paradigm that strategically adjusts policy-level reasoning capacity within temporally grounded contexts. To facilitate systematic evaluation, we restructured a long-duration colonoscopy VideoQA benchmark, Colon-LQA, and conducted extensive experiments on Colon-LQA and REAL-Colon-VQA. Experimental results demonstrate that our approach achieves consistent performance gains in long-range reasoning with temporally grounded inference. Code link: https://github.com/RascalGdd/SurgLQA.
Diandian Guo, Xikai Yang, Ruiyang Li +2
May 16, 2026cs.RO

SSTL: Self-Sensing Tendon Loop for Hysteresis Modeling and Compensation in Tendon-Sheath Mechanisms

Flexible endoscopic robots enable minimally invasive access through natural orifices, but their control accuracy is limited by configuration-dependent hysteresis in the tendon-sheath mechanisms (TSMs). Tendon-sheath friction and tendon elasticity induce a systematic discrepancy between the proximal actuation input and distal output, and this discrepancy varies with the insertion tube configuration. To address this challenge, this paper proposes the Self-Sensing Tendon Loop (SSTL), a double-pass tendon loop routed through the insertion tube and wrapped around a distal pulley, and returned to the proximal end. The loop structure allows both the input and output tensions of the SSTL to be measured proximally, thereby providing an input-output tension profile without requiring distal force or fiber-optic sensors. Because the SSTL shares the same routing path as the actuation TSM, the two TSMs exhibit strongly correlated hysteresis behaviors. From the SSTL tension profile, a learning-based mapping estimates the configuration-dependent hysteresis parameters of the actuation TSM, which are then used by a feedforward controller to compensate for actuation hysteresis. We validate the proposed method by tracking actuation tendon tension under three different insertion tube configurations. Across sinusoidal and random trajectories, the proposed method reduces average RMSE by 88.1% compared with the uncompensated baseline, achieving 97.8% of the performance of direct identification, which requires direct measurement of the input and output tension profile of the actuation TSM.
Myeongbo Park, Junhyun Park, Ihsan Ullah +2
May 15, 2026cs.CV

DepthPolyp: Pseudo-Depth Guided Lightweight Segmentation for Real-Time Colonoscopy

Accurate polyp segmentation in colonoscopy is essential for early colorectal cancer detection, yet real-world clinical environments pose persistent challenges such as motion blur, specular reflections, and illumination instability. Most existing methods are optimized on clean benchmark images and suffer noticeable performance degradation when deployed in authentic surgical scenarios. We propose DepthPolyp, a lightweight and robust segmentation framework based on pseudo-depth-guided multi-task learning and efficient feature modulation. The architecture combines hierarchical Ghost factorization for compact feature generation, Interleaved Shuffle Fusion for low-cost cross-scale interaction, and Dynamic Group Gating for adaptive group-wise feature weighting. Extensive experiments demonstrate that DepthPolyp achieves strong cross-dataset generalization when trained on degraded data and evaluated on both clean and noisy target domains, consistently outperforming lightweight baselines and remaining competitive with substantially larger models. In real surgical video evaluation on PolypGen, DepthPolyp achieves better segmentation performance than models up to 20×20\times larger while preserving real-time inference speed. With only 3.57M parameters and 0.86 GMACs, the proposed method runs at over 180 FPS on mobile devices, making it well suited for real-time deployment in resource-constrained clinical environments. Code and pretrained weights are available at: https://github.com/ReaganWu/DepthPolyp/
Zhuoyu Wu, Wenhui Ou, Lexi Zhang +5
May 15, 2026cs.CV

EndoGSim: Physics-Aware 4D Dynamic Endoscopic Scene Simulations via MLLM-Guided Gaussian Splatting

In robot-assisted minimally invasive surgery, high-fidelity dynamic endoscopic scene reconstruction and simulation are crucial to enhancing downstream tasks and advancing surgical outcomes. However, existing methods primarily focus on visual reconstruction, lacking physics-based descriptions of the scene required for realistic simulation. We propose a unified framework that achieves physics-aware reconstruction and physical simulation of endoscopic scenes through Multi-modal Large Language Models (MLLMs)-guided Gaussian Splatting. Our approach utilizes 4D Gaussian Splatting (4DGS) integrated with pre-trained segmentation and depth estimation to represent deformable tissues and tools. To achieve automatic inference of physical properties, we introduce an object-wise material field that initializes material parameters via MLLM and refines them through a differentiable Material Point Method (MPM) under joint supervision from rendered images and optical flow. Validated on both open-source and in-house datasets, our framework achieves superior simulation fidelity and physical accuracy compared to state-of-the-art methods, underscoring its potential to advance robot-assisted surgical applications.
Changjing Liu, Yiming Huang, Long Bai +2
May 14, 2026cs.CV

SurgicalMamba: Dual-Path SSD with State Regramming for Online Surgical Phase Recognition

Online surgical phase recognition (SPR) underpins context-aware operating-room systems and requires committing to a prediction at every frame from past context alone. Surgical video poses three demands that natural-video recognizers do not jointly address: procedures span tens of thousands of frames, time flows non-uniformly as long routine stretches are punctuated by brief phase-defining transitions, and the visual domain is narrow so backbone features are strongly correlated across channels. Existing recognizers either let per-frame cost grow with elapsed length, or hold cost bounded but advance state at a uniform rate with channel-independent dynamics, leaving the latter two demands unaddressed. We present SurgicalMamba, a causal SPR model built on Mamba2's structured state-space duality (SSD) that holds per-frame cost at O(d). It introduces three SSD-compatible components that jointly address these demands: a dual-path SSD block that separates long- and short-term regimes at the level of recurrent state; intensity-modulated stepping, a continuous-time time-warp that adapts the slow path's effective rate to phase-relevant information; and state regramming, a per-chunk Cayley rotation that opens cross-channel mixing in the otherwise axis-aligned SSM recurrence. The learned rotation planes inherit a phase-aligned structure without any direct supervision, offering an interpretable internal signature of surgical workflow. Across seven public SPR benchmarks, SurgicalMamba reaches state-of-the-art accuracy and phase-level Jaccard under strict online evaluation: 94.6%/82.7% on Cholec80 (+0.7 pp/+2.2 pp over the strongest prior) and 89.5%/68.9% on AutoLaparo (+1.7 pp/+2.0 pp), at 238.74 fps on a single GPU. Ablations isolate the contribution of each component. The code is publicly available at https://github.com/sukjuoh/Surgical-Mamba.
Sukju Oh, Sukkyu Sun
May 14, 2026cs.CV

Towards Real-Time Autonomous Navigation: Transformer-Based Catheter Tip Tracking in Fluoroscopy

Purpose: Mechanical thrombectomy (MT) improves stroke outcomes, but is limited by a lack of local treatment access. Widespread distribution of reinforcement learning (RL)-based robotic systems can be used to alleviate this challenge through autonomous navigation, but current RL methods require live device tip coordinate tracking to function. This paper aims to develop and evaluate a real-time catheter tip tracking pipeline under fluoroscopy, addressing challenges such as low contrast, noise, and device occlusion. Methods: A multi-threaded pipeline was designed, incorporating frame reading, preprocessing, inference, and post-processing. Deep learning segmentation models, including U-Net, U-Net+Transformer, and SegFormer, were trained and benchmarked using two-class and three-class formulations. Post-processing involved two-step component filtering, one-pixel medial skeletonization, and greedy arc-length path following with contour fall-back. Results: On manually-labeled moderate complexity fluoroscopic video data, the two-class SegFormer achieved a mean absolute error of 4.44 mm, outperforming U-Net (4.60 mm), U-Net+Transformer (6.20 mm) and all three-class models (5.19-7.74 mm). On segmentation benchmarks, the system exceeded state-of-the-art CathAction results with improvements of up to +5% in Dice scores for three-segmentation. Conclusion: The results demonstrate that the proposed multi-threaded tracking framework maintains stable performance under challenging imaging conditions, outperforming prior benchmarks, while providing a reliable and efficient foundation for RL-based autonomous MT navigation.
Harry Robertshaw, Yanghe Hao, Weiyuan Deng +6
May 13, 2026cs.CV

Towards Unified Surgical Scene Understanding:Bridging Reasoning and Grounding via MLLMs

Surgical scene understanding is a cornerstone of computer-assisted intervention. While recent advances, particularly in surgical image segmentation, have driven progress, real-world clinical applications require a more holistic understanding that jointly captures procedural context, semantic reasoning, and precise visual grounding. However, existing approaches typically address these components in isolation, leading to fragmented representations and limited semantic consistency. To address this limitation, we propose SurgMLLM, a unified surgical scene understanding framework that bridges high-level reasoning and low-level visual grounding within a single model. Given surgical videos, SurgMLLM fine-tunes a multimodal large language model (MLLM) to support structured interpretability reasoning, which is used to jointly model phases, instrument-verb-target (IVT) triplets, and triplet-entity segmentation tokens. These tokens are then temporally aggregated and serve as prompts for a segmentation network, enabling accurate pixel-wise grounding of triplet instruments and targets. The entire framework is trained end-to-end with a unified objective that couples language-based reasoning supervision with visual grounding losses, promoting coherent cross-task learning and clinically consistent scene representations. To facilitate unified evaluation, we introduce CholecT45-Scene, extending CholecT45 dataset with 64,299 frames of pixel-level mask annotations for instruments and targets, aligned with existing triplet labels. Extensive experiments show that SurgMLLM significantly advances surgical scene understanding, improving the primary triplet recognition metric AP_IVT from 40.7% to 46.0% and consistently outperforming prior methods in phase recognition and segmentation. These results highlight the effectiveness of unified reasoning-and-grounding for reliable, context-aware surgical assistance.
Jincai Huang, Shihao Zou, Yuchen Guo +5
May 12, 2026cs.LG

Low-Rank Adapters Initialization via Gradient Surgery for Continual Learning

LoRA is widely adopted for continual fine-tuning of Large Language Models due to its parameter efficiency, modularity across tasks, and compatibility with replay strategies. However, LoRA-based continual learning remains vulnerable to catastrophic forgetting, whose severity depends on how successive task gradients interact: when consecutive task gradients conflict, standard adapter initializations channel updates into subspaces that overwrite previously learned directions. We propose SLICE, a gradient-surgery-based initialization for LoRA adapters in continual learning. SLICE accumulates gradients from both the current task and a replay buffer of prior tasks, reconciles them through a projection operator, and decomposes the result via truncated SVD to initialize the adapter weights. We evaluate SLICE on the TRACE benchmark and sequences of Super-NI tasks, including a set of adversarial Super-NI sequences that we construct by mining task pairs with maximally opposing gradients. Compared to vanilla LoRA, LoRA-GA, and LoRAM, SLICE consistently achieves a better stability-plasticity trade-off, improving Average Performance, Final Performance and Forgetting metrics while preserving General Performance and In Context Performance across both standard and adversarial continual learning sequences.
Joana Pasquali, Ramiro N. Barros, Arthur S. Bianchessi +7
May 11, 2026cs.CV

Hi-GaTA: Hierarchical Gated Temporal Aggregation Adapter for Surgical Video Report Generation

Automated, clinician-grade assessment reports for surgical procedures could reduce documentation burden and provide objective feedback, yet remain challenging due to the difficulty of aligning dense spatio-temporal video representations with language-based reasoning and the scarcity of high-quality, privacy-preserving datasets. To address this gap, we establish a benchmark comprising 214 high-quality simulated surgical videos paired with surgeon-authored evaluation reports. Building on this resource, we propose a Perception-Alignment-Reasoning framework for surgical video report generation, featuring Hi-GaTA, a novel lightweight temporal adapter that efficiently compresses long video sequences into compact, LLM-compatible visual prefix tokens through short-to-long-range temporal aggregation. For robust visual perception, we pretrain Sur40k, a surgical-specific ViViT-style video encoder on 40,000 minutes of public surgical videos to capture fine-grained spatio-temporal procedural priors. Hi-GaTA employs a temporal pyramid with text-conditioned dual cross-attention, and improves multi-scale consistency through cross-level gated fusion and an increasing-depth strategy. Finally, we fine-tune the LLM backbone using LoRA to enable coherent and stylistically consistent surgical report generation under limited supervision. Experiments show our approach achieves the best overall performance, with consistent gains over strong Multimodal Large Language Model (MLLM) baselines. Ablation studies further validate the effectiveness of each proposed component.
Kedi Sun, Chaohui Dang, Yue Feng +3
May 9, 2026eess.IV

VISTA: A Benchmark for Real-Time Video Streaming under Network Impairments in Surgical Teleoperation

Real-time video streaming is crucial in surgical teleoperation, yet reproducible evaluation under realistic network impairments remains limited. This paper presents VISTA, a benchmark designed to study how impairments along the forward video path affect received video quality, temporal continuity, and human task performance. VISTA employs Linux Traffic Control with NetEm and a Gilbert-Elliott loss model to emulate five network conditions: Hospital LAN, 5G Urban, 4G Rural, LEO Satellite, and GEO Satellite. The benchmark integrates a standardised peg transfer task with synchronized measurements of network quality of service (QoS), objective video quality (PSNR, SSIM, and VMAF), and temporal continuity through freeze rate, while maintaining a stable reverse control channel. Across 375 experimental trials, network degradation substantially reduced teleoperation performance: success rate decreased from 97% in Hospital LAN to 79% in 5G Urban, 35% in 4G Rural, 71% in LEO Satellite, and 12% in GEO Satellite, while mean task completion time for successful trials increased from 80 s in Hospital LAN to 117 s in 5G Urban, 211 s in 4G Rural, 152 s in LEO Satellite, and 255 s in GEO Satellite. These findings show that network impairments have a direct impact on task completion and success in surgical teleoperation, and provide a reproducible basis for evaluating teleoperation video under realistic network constraints. Source code available at https://github.com/Dzxx623/VISTA.
Zexin Deng, Zhenhui Yuan, Tian Lu +3
May 9, 2026cs.CV

From Articulated Kinematics to Routed Visual Control for Action-Conditioned Surgical Video Generation

Action-conditioned surgical video generation is a critical yet highly challenging problem for robotic surgery. The core difficulty is that low-dimensional control vectors must precisely govern complex image-space evolution. In this work, we propose a kinematic-to-visual lifting paradigm that converts articulated kinematics into a unified set of five image-aligned control modalities. Building on this representation, we introduce a hierarchically routed visual control framework that selectively activates the most relevant control modalities and motion scales. Instead of uniformly applying all control signals, our model performs hierarchical routing to dynamically allocate conditioning capacity. We further design kinematic-prior-guided routing loss functions to ensure physically meaningful, temporally stable, and efficient expert utilization. To improve efficiency, we propose a budgeted training and inference scheme that leverages routing-induced sparsity. By selectively discarding low-significance control pathways during training and execution, our approach enables adaptive computation that is complementary to standard distillation. We additionally construct a new benchmark with curated articulated annotations, obtained through human-in-the-loop semantic labeling and differentiable pose tracking, providing realistic supervision for action-conditioned surgical video generation. Extensive experiments demonstrate that our method consistently improves action faithfulness, visual fidelity, and cross-domain generalization over diverse baselines. Moreover, our efficient variant achieves substantial reductions in latency while maintaining strong control accuracy.
Bohan Li, Shuojue Yang, Baorui Peng +10
May 8, 2026cs.CV

OphEdit: Training-Free Text-Guided Editing of Ophthalmic Surgical Videos

High-fidelity surgical video generation can greatly improve medical training and the development of AI, adapting these generative models for precise video editing remains a formidable challenge. Modifying surgical attributes, such as instrument tissue interactions or procedural phases is challenging due to the strict anatomical and temporal constraints. In this paper, we propose OphEdit, a novel training-free framework for the text-guided editing of ophthalmic surgical videos. Our approach leverages a deterministic second-order ODE inversion pipeline to capture Attention Value (V) tensors from the original video. By selectively injecting these stored tensors into the conditional Classifier-Free Guidance (CFG) branch during the denoising phase, OphEdit rigorously preserves the intricate anatomical geometry of the eye while seamlessly mapping text-driven semantic modifications onto the video stream. Clinical evaluations demonstrates that OphEdit effectively handles complex surgical transformations, such as instrument swaps and procedural variations, with superior structural fidelity and temporal consistency compared to natural-domain video editors. Our work represents the first application of training-free video editing in the ophthalmic surgical domain, offering a scalable solution for generating diverse, annotated medical datasets without the need for exhaustive manual recording or costly model fine-tuning. The code and prompts can be accessed at https://github.com/ophedit/OphEdit
Ritul Jangir, Arkya Jyoti Bagchi, Aiman Farooq +3
May 6, 2026cs.RO

Autonomous Laparoscope Control through Unified Mechanics-Based Representation of Multimodal Intraoperative Information

Laparoscope-holding robots can provide surgeons with a stable laparoscopic field of view (FOV) and reduce the burden on human assistants. To maintain an ideal intraoperative FOV, the robot must continuously adjust the laparoscope pose according to intraoperative information. However, intraoperative multimodal signals, such as position, force/torque, and images, differ markedly in physical meaning and units, making it difficult to build a unified representation and to generate control commands that can be used directly for laparoscope control. To address this issue, we propose a laparoscope-holding robot control method based on unified mechanics modeling of multimodal information. First, we design mapping strategies for multiple intraoperative sources, including position, force/torque, and images, and unify them into an equivalent-wrench representation in the operational space. Then, using a task-priority scheme, we inject the wrenches into the task space and the null space, respectively, and synthesize laparoscope control commands via task-priority projection, thereby achieving consistent representation and coordinated fusion of multimodal information within a single framework. Finally, taking the intraoperative remote center of motion (RCM) position, force/torque sensor readings, and laparoscopic images as examples, we construct an RCM-constraint wrench to enforce the RCM geometric constraint and reduce the contact force at the trocar site, a laparoscope-manipulation wrench to enable compliant dragging, and an instrument-tracking wrench to achieve autonomous visual tracking of the instruments. Experiments on a surgical phantom and in vivo porcine trials demonstrate that the proposed method supports multi-task operation, including compliant laparoscope manipulation and autonomous instrument tracking, while maintaining the RCM constraint and reducing sustained trocar-site loading.
Xiaojian Li, Jin Fang, Yudong Shi +6
May 5, 2026cs.AI

Actionable Real-Time Modeling of Surgical Team Dynamics via Time-Expanded Interaction Graphs

Surgical team performance arises from complex interactions between technical execution and non-technical skills, including communication and coordination dynamics. However, current surgical AI systems predominantly model visual workflow signals, lacking structured representations of intraoperative team interactions over time. We propose a real-time actionable approach for modeling surgical team dynamics using time-expanded interaction graphs, where team members are modeled as time-indexed nodes and communication exchanges define directed edges. This spatio-temporal expansion enables dynamic interaction modeling, while allowing efficient inference with a static graph neural network. The model predicts procedural efficiency as the deviation from the expected duration and supports real-time deployment. Beyond prediction, we perform a counterfactual analysis to identify minimal changes in communication structure and interpretable behavioral variables associated with improved predicted outcomes. Experiments on recorded surgical procedures show that structured modeling of team interactions improves early identification of prolonged interventions and provides coherent, actionable explanations. This work advances surgical AI toward real-time, team-aware, and actionable decision support in the operating room.
Vincenzo Marco De Luca, Antonio Longa, Giovanna Varni +1
May 3, 2026cs.CV

SurgCheck: Do Vision-Language Models Really Look at Images in Surgical VQA?

Purpose: Vision-language models (VLMs) have shown promising performance in surgical visual question answering (VQA). However, existing surgical VQA datasets often contain linguistic shortcuts, where question phrasing implicitly constrains the answer space. It remains unclear whether reported performance reflects visual understanding or reliance on such linguistic shortcuts. Methods: We introduce SurgCheck, a diagnostic benchmark for quantifying linguistic shortcut reliance in surgical VQA. SurgCheck employs a paired-question design in which each surgical frame is associated with an original question containing entity names and a less-biased counterpart that removes these names while preserving identical visual content and ground-truth answers. The resulting performance gap provides a diagnostic signal of shortcut reliance. To ensure that the less-biased question remains well-defined even without entity names, four grounding cues are incorporated: bounding box, arrow, spatial position, and periphrasis. We evaluate both general-purpose and surgical-specific VLMs under zero-shot and fine-tuned settings on SurgCheck. To evaluate open-ended zero-shot responses, we introduce an LLM-as-a-judge evaluation protocol. Results: Using SurgCheck, we observe consistent performance degradation on less-biased questions across five VLMs, despite identical visual inputs. Text-only ablation reveals minimal performance drops for action and target prediction, indicating that action and target prediction is largely driven by linguistic shortcuts rather than visual reasoning. Conclusion: SurgCheck provides a controlled diagnostic framework that exposes failure modes masked by linguistic bias in existing surgical VQA benchmarks. Our findings demonstrate that strong benchmark performance does not necessarily imply faithful visual understanding, underscoring the need for bias-aware evaluation in surgical VQA.
Jongmin Shin, Ka Young Kim, Eunki Cho +2
Apr 30, 2026cs.RO

An Experimental Modular Instrument With a Haptic Feedback Framework for Robotic Surgery Training

Robotic-assisted surgery offers significant clinical advantages but largely eliminates direct haptic feedback, increasing the risk of excessive tool-tissue interaction forces. Although recent commercial systems have begun to introduce force feedback, their high cost limits accessibility, particularly for surgical training. This paper presents a modular experimental robotic laparoscopic instrument integrated with a real-time haptic feedback framework. The proposed instrument employs a wrist-mounted force/torque (F/T) sensor to estimate tool-tissue interaction forces while avoiding the durability and integration challenges of tip-mounted sensors. A haptic feedback framework is developed to extract the external contact forces, render them to the haptic device, and generate stable and perceptually meaningful feedback. The instrument is integrated into the robotic surgery training system (RoboScope) and evaluated through a controlled user study involving a force regulation task. Experimental results demonstrate that haptic feedback significantly improves task success rate, force regulation accuracy, and task efficiency compared to visual-only feedback. The proposed instrument enables stable, high-fidelity haptic interaction, supporting effective robotic surgery training.
Walid Shaker, Mustafa Suphi Erden
Apr 30, 2026eess.IV

A Real-time Scale-robust Network for Glottis Segmentation in Nasal Transnasal Intubation

Nasotracheal intubation (NTI) is a critical clinical procedure for establishing and maintaining patient airway patency. Machine-assisted NTI has emerged as a pivotal approach for optimizing procedural efficiency and minimizing manual intervention. However, visual detection algorithms employed for NTI navigation encounter significant challenges, including complex anatomical environments and suboptimal illumination conditions surrounding the glottis. Additionally, the glottis presents considerable scale variability throughout the procedure, initially appearing as a small, difficult-to-capture structure before expanding to occupy nearly the entire field of view. Moreover, traditional visual detection methods often have high computational costs, making real-time, high-precision detection on portable devices challenging. To enhance NTI efficacy and address these challenges, this paper proposes a novel glottis segmentation framework optimized for vision-assisted NTI applications. First, we designed a lightweight, multi-receptive field feature extraction module to reduce intra-class differences, achieving robustness to scale variations of the glottis. This module was then stacked to form the backbone and neck of our network. Subsequently, we developed an advanced label assignment method and redefined the number of samples to further reduce intra-class differences and enhance accuracy in the complex NTI environment. Experiments on three distinct datasets demonstrate that our network surpasses state-of-the-art algorithms, achieving a segmentation mDice of 92.9% with a compact model size of 19 MB and an inference speed exceeding 170 frames per second. % Our code and datasets will be open-sourced on GitHub after the manuscript is accepted. Our code and datasets are available at https://github.com/HBUT-CV/GlottisNet.
Yang Zhou, Chaoyong Zhang, Ruoyi Hao +3
Apr 29, 2026cs.CV

Two-View Accumulation as the Primary Training Lever for Hybrid-Capture Gaussian Splatting: A Variance-Decomposition View of When Gradient Surgery Helps

Hybrid-capture novel view synthesis combines images at substantially different camera distances (e.g., aerial drone and ground-level views). Standard 3D Gaussian Splatting (3DGS), trained for 30K iterations with one rendered view per optimizer step, under-fits the minority regime by 1-3 dB on five hybrid-capture benchmarks. We isolate the lever that closes this gap. Among compute-matched alternatives -- vanilla 60K iterations, magnitude corrections (GradNorm), direction-aware near/far gradient surgery, projective preconditioning, confidence-gated sample-level surgery, and a random two-view-per-step control -- the simplest structural change wins: rendering two views per optimizer step. The pairing rule (geometry-defined near/far, random, or active loss-disparity) does not change PSNR beyond seed variance on any of the five scenes; the structural change of having two views per step does. We propose a variance-decomposition framework that predicts and explains this finding: under bimodal camera regimes, between-regime gradient variance turns out to be small relative to within-regime variance in 3DGS, so structured and random pairings are variance-equivalent in expectation, and the variance halving from two-view accumulation itself is the dominant effect. We verify the framework on five scenes whose camera-altitude bimodality coefficients span [0.55, 1.00], and we report the negative result that direction-aware projection, magnitude correction, confidence gating, and an active loss-disparity pairing all fall within seed variance of random two-view pairing. The two-view structural lever transfers cleanly to the Scaffold-GS and Pixel-GS backbones. We position this work as an honest characterization of which training-side axes do and do not move PSNR for hybrid-capture 3DGS, together with the framework that explains why.
Sungjun Cho
Apr 29, 2026cs.CV

Virtual-reality based patient-specific simulation of spine surgical procedures: A fast, highly automated and high-fidelity system for surgical education and planning

Surgical training involves didactic teaching, mentor-led learning, surgical skills laboratories, and direct exposure to surgery; however, increasing clinical pressures have limited operating room (OR) exposure. This work leverages virtual reality (VR) to provide a safe and immersive training environment. Existing VR training is often based on standardized scenarios not tailored to individual clinical cases. This study addresses this limitation using artificial intelligence (AI) based computer vision methods to generate patient-specific simulations from computed tomography (CT) and magnetic resonance imaging (MRI). This study focuses on patient-specific spinal decompression simulation for spinal stenosis in a virtual operating room. The objectives were (1) automatic creation of 3D anatomical models and (2) VR simulation of spinal decompression procedures including laminectomy, disc resection, and foraminotomy. Model construction required multimodal fusion (registration) of CT and MRI and segmentation of relevant structures. Segmentation was evaluated using the Dice Similarity Coefficient (DSC), and registration accuracy using Target Registration Error (TRE). Qualitative feedback was obtained from surgeons and trainees. High-fidelity patient-specific 3D models were generated efficiently (approximately 2.5 minutes per case, N = 15). Segmentation accuracy was high, with a DSC of 0.95 (+/- 0.03) for vertebral bone and 0.895 (+/- 0.02) for soft tissue structures. Registration accuracy showed a mean TRE of 1.73 (+/- 0.42) mm. Semi-structured interviews indicated improved spatial understanding, increased procedural confidence, and strong perceived educational value. This platform significantly reduced the time and costs of patient-specific modelling, thereby facilitating pre-operative planning, post-procedural assessments, and comprehensive surgical simulation.
Raj Kumar Ranabhat, Tayler D Ross, Tony Jiao +3
Apr 28, 2026cs.RO

SlicerRoboTMS: An Open-Source 3D Slicer Extension for Robot-Assisted Transcranial Magnetic Stimulation

Robot-assisted Transcranial Magnetic Stimulation (Robo-TMS) is an image-guided robotic intervention that enhances the accuracy and reproducibility of conventional Transcranial Magnetic Stimulation (TMS), a widely used non-invasive brain stimulation procedure in clinical treatment and neuroscience research. Despite its potential, the development of Robo-TMS remains challenging due to the need for multidisciplinary expertise spanning medical imaging, computer vision, and robotics. This paper presents SlicerRoboTMS, an open-source 3D Slicer extension that provides a unified interaction infrastructure for Robo-TMS research. By leveraging 3D Slicer's medical image computing and visualisation capabilities, the extension supports Magnetic Resonance Imaging (MRI)-based neuronavigation and interfaces with robotic systems through standardised communication protocols and configurable system descriptions. An example integration is presented to demonstrate how SlicerRoboTMS can be incorporated into a representative Robo-TMS workflow. Designed to support diverse hardware configurations and rapid prototyping, SlicerRoboTMS lowers the barrier to entry and facilitates reproducible and extensible research in Robo-TMS. The extension is available at https://github.com/OpenRoboTMS/SlicerRoboTMS.
Wenzhi Bai, Yituo Guo, Bhaskar Basu +2
Apr 28, 2026cs.CV

SAMe: A Semantic Anatomy Mapping Engine for Robotic Ultrasound

Robotic ultrasound has advanced local image-driven control, contact regulation, and view optimization, yet current systems lack the anatomical understanding needed to determine what to scan, where to begin, and how to adapt to individual patient anatomy. These gaps make systems still reliant on expert intervention to initiate scanning. Here we present SAMe, a semantic anatomy mapping engine that provides robotic ultrasound with an explicit anatomical prior layer. SAMe addresses scan initiation as a target-to-anatomy-to-action process: it grounds under-specified clinical complaints into structured target organs, instantiates a patient-specific anatomical representation for the grounded targets from a single external body image, and translates this representation into control-facing 6-DoF probe initialization states without any additional registration using preoperative CT or MRI. The anatomical representation maintained by SAMe is explicit, lightweight (single-organ inference in 0.08s), and compatible with downstream control by design. Across semantic grounding, anatomical instantiation, and real-robot evaluation, SAMe shows strong performance across the full initialization pipeline. In real-robot experiments, centroid-based SAMe initialization outperformed the body-keypoint-based heuristic baseline under a budget-matched single-target setting for both liver (86.7% versus 46.7%) and kidney (80.0% versus 73.3%) initialization. Furthermore, The trial-level organ-hit rate reached 97.3% for liver and 83.3% for kidney when multiple candidate targets were available. These results establish an explicit anatomical prior layer that addresses scan initialization and is designed to support broader downstream autonomous scanning pipelines, providing the anatomical foundation for complaint-driven, anatomically informed robotic ultrasonography.
Jing Zhang, Duojie Chen, Wentao Jiang +7
Apr 27, 2026cs.CV

Touchless Intraoperative Image Access System Based on Vision-Based Hand Tracking

Touchless interaction with medical images is becoming increasingly important in the surgical field, where sterility and continuity of the operational workflow are essential requirements. This work presents a vision-based system for intraoperative navigation of medical images through hand gestures acquired using a single RGB camera. Unlike many existing solutions, the system does not require additional hardware or user-specific training. Hand tracking is performed in real time using MediaPipe Hands, which provides a 2.5D estimation of hand landmarks. Simple and intuitive gestures are then mapped into translation, rotation, and zoom commands, enabling continuous and natural interaction with the image viewer. The system architecture is independent from the visualization software and, for implementation simplicity, in this study it was integrated with PyVista. Performance was evaluated through frame-level logging and quantitative analysis of latency, stability, and interaction robustness metrics. Experimental results highlight real-time behavior, with reduced latencies and stable control, in line with the requirements of fluid interaction. The system demonstrates the feasibility of a low-cost touchless solution for intraoperative access to medical images, laying the groundwork for future clinical evaluations.
Yin Lin, Domenico Aquino, Alberto Redaelli +3
Apr 26, 2026cs.RO

Real-Time Non-Contact Force Compensation for Wrist-Mounted Force/Torque Sensors in Haptic-Enabled Robotic Surgery Training

Haptic feedback has been a long-missed feature in robotic-assisted surgery, one that would allow surgeons to perceive tissue properties and apply controlled forces during delicate procedures. Although commercial robotic systems have begun to integrate haptic technologies, their high costs limit accessibility for training and research purposes. To address this gap, we extend our previously developed low-cost robotic surgery training setup, RoboScope, by incorporating a wrist-mounted force/torque (F/T) sensor for haptic feedback training. Wrist-mounted sensing avoids many challenges associated with tip-mounted sensors but introduces additional non-contact forces, such as gravity, sensor bias, installation offsets, and associated torques, which compromise measurement accuracy. In this paper, we propose a robust real-time compensation method based on recursive least squares (RLS). This method eliminates the need for dataset collection and frequent recalibration while adapting to changing operating conditions. Experimental validation demonstrates that the proposed approach achieves over 95% error reduction in non-contact force compensation and more than 91% in non-contact torque compensation, significantly outperforming existing methods. These results highlight the potential of our approach for providing reliable haptic feedback in robotic surgery training and research.
Walid Shaker, Mustafa Suphi Erden
Apr 24, 2026cs.LG

Sum-of-Checks: Structured Reasoning for Surgical Safety with Large Vision-Language Models

Purpose: Accurate assessment of the Critical View of Safety (CVS) during laparoscopic cholecystectomy is essential to prevent bile duct injury, a complication associated with significant morbidity and mortality. While large vision-language models (LVLMs) offer flexible reasoning, their predictions remain difficult to audit and unreliable on safety-critical surgical tasks. Methods: We introduce Sum-of-Checks, a framework that decomposes each CVS criterion into expert-defined reasoning checks reflecting clinically relevant visual evidence. Given a laparoscopic frame, an LVLM evaluates each check, producing a binary judgment and justification. Criterion-level scores are computed via fixed, weighted aggregation of check outcomes. We evaluate on the Endoscapes2023 benchmark using three frontier LVLMs, comparing against direct prompting, chain-of-thought, and sub-question decomposition, each with and without few-shot examples. Results: Sum-of-Checks improves average frame-level mean average precision by 12--14% relative to the best baseline across all three models and criteria. Analysis of individual checks reveals that LVLMs are reliable on observational checks (e.g., visibility, tool obstruction) but show substantial variability on decision-critical anatomical evidence. Conclusion: Structuring surgical reasoning into expert-aligned verification checks improves both accuracy and transparency of LVLM-based CVS assessment, demonstrating that explicitly separating evidence elicitation from decision-making is critical for reliable and auditable surgical AI systems. Code is available at https://github.com/BrachioLab/SumOfChecks.
Weiqiu You, Cassandra Goldberg, Amin Madani +2
Apr 22, 2026cs.RO

Open-H-Embodiment: A Large-Scale Dataset for Enabling Foundation Models in Medical Robotics

Autonomous medical robots hold promise to improve patient outcomes, reduce provider workload, democratize access to care, and enable superhuman precision. However, autonomous medical robotics has been limited by a fundamental data problem: existing medical robotic datasets are small, single-embodiment, and rarely shared openly, restricting the development of foundation models that the field needs to advance. We introduce Open-H-Embodiment, the largest open dataset of medical robotic video with synchronized kinematics to date, spanning more than 50 institutions and multiple robotic platforms including the CMR Versius, Intuitive Surgical's da Vinci, da Vinci Research Kit (dVRK), Rob Surgical BiTrack, Virtual Incision's MIRA, Moon Surgical Maestro, and a variety of custom systems, spanning surgical manipulation, robotic ultrasound, and endoscopy procedures. We demonstrate the research enabled by this dataset through two foundation models. GR00T-H is the first open foundation vision-language-action model for medical robotics, which is the only evaluated model to achieve full end-to-end task completion on a structured suturing benchmark (25% of trials vs. 0% for all others) and achieves 64% average success across a 29-step ex vivo suturing sequence. We also train Cosmos-H-Surgical-Simulator, the first action-conditioned world model to enable multi-embodiment surgical simulation from a single checkpoint, spanning nine robotic platforms and supporting in silico policy evaluation and synthetic data generation for the medical domain. These results suggest that open, large-scale medical robot data collection can serve as critical infrastructure for the research community, enabling advances in robot learning, world modeling, and beyond.
Open-H-Embodiment Consortium, :, Nigel Nelson +213
Apr 22, 2026cs.RO

A Vision-Language-Action Model for Adaptive Ultrasound-Guided Needle Insertion and Needle Tracking

Ultrasound (US)-guided needle insertion is a critical yet challenging procedure due to dynamic imaging conditions and difficulties in needle visualization. Many methods have been proposed for automated needle insertion, but they often rely on hand-crafted pipelines with modular controllers, whose performance degrades in challenging cases. In this paper, a Vision-Language-Action (VLA) model is proposed for adaptive and automated US-guided needle insertion and tracking on a robotic ultrasound (RUS) system. This framework provides a unified approach to needle tracking and needle insertion control, enabling real-time, dynamically adaptive adjustment of insertion based on the obtained needle position and environment awareness. To achieve real-time and end-to-end tracking, a Cross-Depth Fusion (CDF) tracking head is proposed, integrating shallow positional and deep semantic features from the large-scale vision backbone. To adapt the pretrained vision backbone for tracking tasks, a Tracking-Conditioning (TraCon) register is introduced for parameter-efficient feature conditioning. After needle tracking, an uncertainty-aware control policy and an asynchronous VLA pipeline are presented for adaptive needle insertion control, ensuring timely decision-making for improved safety and outcomes. Extensive experiments on both needle tracking and insertion show that our method consistently outperforms state-of-the-art trackers and manual operation, achieving higher tracking accuracy, improved insertion success rates, and reduced procedure time, highlighting promising directions for RUS-based intelligent intervention.
Yuelin Zhang, Qingpeng Ding, Longxiang Tang +2
Apr 22, 2026cs.CV

SurgCoT: Advancing Spatiotemporal Reasoning in Surgical Videos through a Chain-of-Thought Benchmark

Fine-grained spatiotemporal reasoning on surgical videos is critical, yet the capabilities of Multi-modal Large Language Models (MLLMs) in this domain remain largely unexplored. To bridge this gap, we introduce SurgCoT, a unified benchmark for evaluating chain-of-thought (CoT) reasoning in MLLMs across 7 surgical specialties and 35 diverse procedures. SurgCoT assesses five core reasoning dimensions: Causal Action Ordering, Cue-Action Alignment, Affordance Mapping, Micro-Transition Localization, and Anomaly Onset Tracking, through a structured CoT framework with an intensive annotation protocol (Question-Option-Knowledge-Clue-Answer), where the Knowledge field provides essential background context and Clue provides definitive spatiotemporal evidence. Evaluation of 10 leading MLLMs shows: 1) commercial models outperform open-source and medical-specialized variants; 2) significant gaps exist in surgical CoT reasoning; 3) SurgCoT enables effective evaluation and enhances progressive spatiotemporal reasoning. SurgCoT provides a reproducible testbed to narrow the gap between MLLM capabilities and clinical reasoning demands. Code: https://github.com/CVI-SZU/SurgCoT.
Gui Wang, YongSong Zhou, Kaijun Deng +4
Apr 22, 2026cs.RO

Toward Safe Autonomous Robotic Endovascular Interventions using World Models

Autonomous mechanical thrombectomy (MT) presents substantial challenges due to highly variable vascular geometries and the requirements for accurate, real-time control. While reinforcement learning (RL) has emerged as a promising paradigm for the automation of endovascular navigation, existing approaches often show limited robustness when faced with diverse patient anatomies or extended navigation horizons. In this work, we investigate a world-model-based framework for autonomous endovascular navigation built on TD-MPC2, a model-based RL method that integrates planning and learned dynamics. We evaluate a TD-MPC2 agent trained on multiple navigation tasks across hold out patient-specific vasculatures and benchmark its performance against the state-of-the-art Soft Actor-Critic (SAC) algorithm agent. Both approaches are further validated in vitro using patient-specific vascular phantoms under fluoroscopic guidance. In simulation, TD-MPC2 demonstrates a significantly higher mean success rate than SAC (58% vs. 36%, p < 0.001), and mean tip contact forces of 0.15 N, well below the proposed 1.5 N vessel rupture threshold. Mean success rates for TD-MPC2 (68%) were comparable to SAC (60%) in vitro, but TD-MPC2 achieved superior path ratios (p = 0.017) at the cost of longer procedure times (p < 0.001). Together, these results provide the first demonstration of autonomous MT navigation validated across both hold out in silico data and fluoroscopy-guided in vitro experiments, highlighting the promise of world models for safe and generalizable AI-assisted endovascular interventions.
Harry Robertshaw, Nikola Fischer, Han-Ru Wu +6
Apr 20, 2026cs.CV

Trustworthy Endoscopic Super-Resolution

Super-resolution (SR) models are attracting growing interest for enhancing minimally invasive surgery and diagnostic videos under hardware constraints. However, valid concerns remain regarding the introduction of hallucinated structures and amplified noise, limiting their reliability in safety-critical settings. We propose a direct and practical framework to make SR systems more trustworthy by identifying where reconstructions are likely to fail. Our approach integrates a lightweight error-prediction network that operates on intermediate representations to estimate pixel-wise reconstruction error. The module is computationally efficient and low-latency, making it suitable for real-time deployment. We convert these predictions into operational failure decisions by constructing Conformal Failure Masks (CFM), which localize regions where the SR output should not be trusted. Built on conformal risk control principles, our method provides theoretical guarantees for controlling both the tolerated error limit and the miscoverage in detected failures. We evaluate our approach on image and video SR, demonstrating its effectiveness in detecting unreliable reconstructions in endoscopic and robotic surgery settings. To our knowledge, this is the first study to provide a model-agnostic, theoretically grounded approach to improving the safety of real-time endoscopic image SR.
Julio Silva-Rodríguez, Ender Konukoglu
Apr 20, 2026cs.AI

SPREG: Structured Plan Repair with Entropy-Guided Test-Time Intervention for Large Language Model Reasoning

Large Language Models (LLMs) are prone to logical hallucinations and stochastic drifts during long-chain reasoning. While Classifier-Free Guidance (CFG) can improve instruction adherence, standard static implementations often cause semantic dilution and linguistic degradation. We propose SPREG (Structured Plan-guided Real-time Entropy Gating), a lightweight inference-time framework for surgical error rectification. SPREG employs an adaptive dual-threshold mechanism to monitor real-time entropy, identifying sudden ``entropy spikes'' as reliable indicators of logical failure. Upon detection, it triggers a dynamic repair by replacing uninformative null-priors with reference distributions synthesized from historical high-confidence states. By modulating guidance intensity according to structured reasoning stages (e.g., Action, Observation), SPREG steers the model back to a stable manifold without compromising fluency. Our experiments demonstrate significant gains, notably a 20.0% absolute accuracy improvement on AIME25, while effectively suppressing uncontrolled entropy drift in complex tasks.
Xuan Wang, Yu Ming, Xinhao Zhong +4
Apr 17, 2026cs.CR

Surgical Repair of Insecure Code Generation in LLMs

Large language models write production code, and yet they routinely introduce well-known vulnerabilities. We show that this is not a knowledge deficit: the same models that generate insecure code, correctly identify and explain the vulnerability when asked directly, this is a gap we call the Format-Reliability Gap. Mechanistic analysis reveals the cause: security representations are encoded from the earliest layers but remain computationally inert until the final layer, where format-compliance demands compete with them. Because the failure is localized to a single layer, per-vulnerability steering vectors reduce insecure generation by up to 74% with negligible overhead. The mechanism and the fix generalize across five models, three architecture families, and six vulnerability types, suggesting insecure code generation is an interpretability problem, not a training artifact.
Gustavo Sandoval, Brendan Dolan-Gavitt, Siddharth Garg
Apr 1, 2026cs.CV

An Approach to Enriching Surgical Video Datasets for Fine-Grained Spatial-Temporal Understanding of Vision-Language Models

Surgical video understanding is a crucial prerequisite for advancing Computer-Assisted Surgery. While vision-language models (VLMs) have recently been applied to the surgical domain, existing surgical vision-language datasets lack in capturing and evaluating complex, interleaved spatial-temporal dynamics. Creating large scale datasets that accurately represent fine-grained spatial-temporal relationships in surgical videos is challenging due to costly manual annotations or error-prone generation using large language models. To address this gap, we introduce the SurgSTU-Pipeline, a deterministic generation pipeline featuring temporal and spatial continuity filtering to reliably create surgical datasets for fine-grained spatial-temporal multimodal understanding. Applying this pipeline to publicly available surgical datasets, we create the SurgSTU dataset, comprising 6711 video clips densely extended with 150k fine-grained spatial-temporal question-answer samples. Our comprehensive evaluation shows that while state-of-the-art generalist VLMs struggle in zero-shot settings, their spatial-temporal capabilities can be improved through in-context learning. A fine-tuned VLM on the SurgSTU training dataset achieves highest performance among all spatial-temporal tasks, validating the dataset's efficacy to improve spatial-temporal understanding of VLMs in surgical videos. The project is available here: https://lennart-maack.github.io/SurgSTU-project
Lennart Maack, Alexander Schlaefer
Mar 31, 2026cs.CV

SurgTEMP: Temporal-Aware Surgical Video Question Answering with Text-guided Visual Memory for Laparoscopic Cholecystectomy

Surgical procedures are inherently complex and risky, requiring extensive expertise and constant focus to navigate evolving intraoperative scenes. Computer-assisted systems such as surgical visual question answering (VQA) offer promises for education and intraoperative support. Current surgical VQA research largely focuses on static frame analysis, overlooking rich temporal semantics. Surgical video question answering is further challenged by low visual contrast, its highly knowledge-driven nature, diverse analytical needs spanning scattered temporal windows, and the hierarchy from basic perception to high-level intraoperative assessment. To address these challenges, we propose SurgTEMP, a multimodal LLM framework featuring (i) a query-guided token selection module that builds hierarchical visual memory (spatial and temporal memory banks) and (ii) a Surgical Competency Progression (SCP) training scheme. Together, they enable effective modeling of variable-length surgical videos while preserving procedure-relevant cues and temporal coherence, and better support diverse downstream assessment tasks. To support model development, we introduce CholeVidQA-32K, a surgical video question answering dataset comprising 32K open-ended QA pairs and 3,855 video segments (approximately 128 h total) from laparoscopic cholecystectomy. The dataset is organized into a three-level hierarchy -- Perception, Assessment, and Reasoning -- spanning 11 tasks from instrument/action/anatomy perception to Critical View of Safety (CVS), intraoperative difficulty, skill proficiency, and adverse event assessment. In comprehensive evaluations against state-of-the-art open-source multimodal and video LLMs (fine-tuned and zero-shot), SurgTEMP achieves substantial performance improvements, advancing the state of video-based surgical VQA. The project page is available at: https://camma-public.github.io/SurgTEMP/
Shi Li, Vinkle Srivastav, Shih-Min Yin +7
Mar 28, 2026cs.AI

A Comparative Study in Surgical AI: Potential and Limitations of Data, Compute, and Scaling

Recent Artificial Intelligence (AI) models have matched or exceeded human experts in several benchmarks of biomedical task performance, but surgical benchmarks in particular are often missing from prominent medical benchmark suites. Since surgery requires integrating disparate tasks, generally-capable AI models could be particularly attractive as a collaborative tool if performance could be improved. On the one hand, the canonical approach of scaling architecture size and training data is attractive, especially since there are millions of hours of surgical video data generated per year. On the other hand, preparing surgical data for AI training requires significantly higher levels of professional expertise, and training on that data requires expensive computational resources. These trade-offs paint an uncertain picture of whether and to-what-extent modern AI could aid surgical practice. In this paper, we explore this question through a case study of surgical tool detection using state-of-the-art AI methods available in 2026. We demonstrate that even with multi-billion parameter models and extensive training, current Vision Language Models fall short in the seemingly simple task of tool detection in neurosurgery. Additionally, we show scaling experiments indicating that increasing model size and training time only leads to diminishing improvements in relevant performance metrics. Thus, our experiments suggest that current models could still face significant obstacles in surgical use cases. Moreover, some obstacles cannot be simply ``scaled away'' with additional compute and persist across diverse model architectures, raising the question of whether data and label availability are the only limiting factors. We discuss the main contributors to these constraints and advance potential solutions.
Kirill Skobelev, Eric Fithian, Yegor Baranovski +9
Mar 26, 2026eess.IV

Colon-Bench: An Agentic Workflow for Scalable Dense Lesion Annotation in Full-Procedure Colonoscopy Videos

Early screening via colonoscopy is critical for colon cancer prevention, yet developing robust AI systems for this domain is hindered by the lack of densely annotated, long-sequence video datasets. Existing datasets predominantly focus on single-class polyp detection and lack the rich spatial, temporal, and linguistic annotations required to evaluate modern Multimodal Large Language Models (MLLMs). To address this critical gap, we introduce Colon-Bench, generated via a novel multi-stage agentic workflow. Our pipeline seamlessly integrates temporal proposals, bounding-box tracking, AI-driven visual confirmation, and human-in-the-loop review to scalably annotate full-procedure videos. The resulting verified benchmark is unprecedented in scope, encompassing 528 videos, 14 distinct lesion categories (including polyps, ulcers, and bleeding), over 300,000 bounding boxes, 213,000 segmentation masks, and 133,000 words of clinical descriptions. We utilize Colon-Bench to rigorously evaluate state-of-the-art MLLMs across lesion classification, Open-Vocabulary Video Object Segmentation (OV-VOS), and video Visual Question Answering (VQA). The MLLM results demonstrate surprisingly high localization performance in medical domains compared to SAM-3. Finally, we analyze common VQA errors from MLLMs to introduce a novel "colon-skill" prompting strategy, improving zero-shot MLLM performance by up to 9.7% across most MLLMs. The dataset and the code are available at https://abdullahamdi.com/colon-bench .
Abdullah Hamdi, Changchun Yang, Xin Gao
Mar 12, 2026cs.RO

Real-time Rendering-based Surgical Instrument Tracking via Evolutionary Optimization

Accurate and efficient tracking of surgical instruments is fundamental for Robot-Assisted Minimally Invasive Surgery. Although vision-based robot pose estimation has enabled markerless calibration without tedious physical setups, reliable tool tracking for surgical robots still remains challenging due to partial visibility and specialized articulation design of surgical instruments. Previous works in the field are usually prone to unreliable feature detections under degraded visual quality and data scarcity, whereas rendering-based methods often struggle with computational costs and suboptimal convergence. In this work, we incorporate CMA-ES, an evolutionary optimization strategy, into a versatile tracking pipeline that jointly estimates surgical instrument pose and joint configurations. Using batch rendering to efficiently evaluate multiple pose candidates in parallel, the method significantly reduces inference time and improves convergence robustness. The proposed framework further generalizes to joint angle-free and bi-manual tracking settings, making it suitable for both vision feedback control and online surgery video calibration. Extensive experiments on synthetic and real-world datasets demonstrate that the proposed method significantly outperforms prior approaches in both accuracy and runtime. Source code and data are available at https://github.com/hanyang-hu/online_dvrk_tracking.
Hanyang Hu, Zekai Liang, Florian Richter +1
Mar 10, 2026cs.RO

Receptogenesis in a Vascularized Robotic Embodiment

Equipping robotic systems with the capacity to generate ex novo\textit{ex novo} hardware during operation extends physical adaptability. Unlike modular systems that rely on discrete component integration pre- or post-deployment, we envision physical adaptation through continuous in-body development via hardware synthesis. Drawing inspiration from circulatory systems that redistribute mass and function in biological organisms, we utilize fluidics to restructure the material interface, a capability currently unmatched in robotics. Here, we realize this proof-of-concept hardware generation through a vascularized robotic composite designed for programmable material synthesis, demonstrated via receptogenesis - the on-demand construction of sensors. By coordinating the fluidic transport of precursors with external localized UV irradiation, we drove an in situ\textit{in situ} photopolymerization that chemically reconstructed the vasculature from the inside out. This reaction converted precursors with photolatent initiator into a solid dispersion of UV-sensitive polypyrrole in PETG, establishing a sensing modality validated by a characteristic decrease in electrical impedance. The newly synthesized sensor closed a local control loop in real time to regulate wing flapping in a moth-inspired robotic demonstrator. Our work is a proof-of-concept materials basis for ex novo\textit{ex novo} hardware generation in a vascularized composite - a step towards situated robots adapting to environmental cues.
Kadri-Ann Pankratov, Leonid Zinatullin, Hans Priks +6
Feb 9, 2026eess.IV

Data-Driven Registration and Modeling of Brain Deformation for Image-Guided Neurosurgery: A Systematic Review

Accurate compensation of brain deformation is critical for reliable image-guided neurosurgery. Surgical manipulation and tumor resection induce tissue motion, causing preoperative planning images to become misaligned with the intraoperative anatomy. In this systematic review, we examine data-driven methods developed between 2020 and 2025 for brain deformation registration and modeling, with a particular focus on learning-based approaches. A comprehensive literature search was conducted in PubMed, IEEE Xplore, Scopus, and Web of Science using predefined inclusion and exclusion criteria for computational methods addressing brain deformation in neurosurgical imaging, resulting in 46 eligible studies. We provide a unified analysis of methodological strategies, including deep learning-based image registration, direct deformation field regression, synthesis-driven multimodal alignment, resection-aware architectures for handling missing correspondences, and hybrid models integrating biomechanical priors. We also examine dataset utilization, evaluation metrics, validation protocols, and the assessment of uncertainty and generalization across studies. While learning-based methods demonstrate promising accuracy and computational efficiency, current approaches remain limited by out-of-distribution robustness, standardized benchmarking, interpretability, and readiness for clinical deployment. Our review highlights these gaps and outlines future directions toward more robust, generalizable, and clinically translatable solutions for neurosurgical guidance. By organizing recent advances and critically assessing evaluation practices, this work provides a comprehensive reference for researchers and clinicians working on data-driven registration and modeling of brain deformation.
Tiago Assis, Colin P. Galvin, Joshua P. Castillo +12
Feb 5, 2026cs.CV

SurgMotion: A Video-Native Foundation Model for Universal Understanding of Surgical Videos

While foundation models have advanced surgical video analysis, current approaches rely predominantly on pixel-level reconstruction objectives that waste model capacity on low-level visual details, such as smoke, specular reflections, and fluid motion, rather than semantic structures essential for surgical understanding. We present SurgMotion, a video-native foundation model that shifts the learning paradigm from pixel-level reconstruction to latent motion prediction. Built on the Video Joint Embedding Predictive Architecture (V-JEPA), SurgMotion introduces three key technical innovations tailored to surgical videos: (1) motion-guided latent masked prediction to prioritize semantically meaningful regions, (2) spatiotemporal affinity self-distillation to enforce relational consistency, and (3) spatiotemporal feature diversity regularization (SFDR) to prevent representation collapse in texture-sparse surgical scenes. To enable large-scale pretraining, we curate SurgMotion-15M, the largest surgical video dataset to date, comprising 3,658 hours of video from 50 sources across 13 anatomical regions. Extensive experiments across 17 benchmarks demonstrate that SurgMotion significantly outperforms state-of-the-art methods on surgical workflow recognition, achieving 14.6 percent improvement in F1 score on EgoSurgery and 10.3 percent on PitVis; on action triplet recognition with 39.54 percent mAP-IVT on CholecT50; as well as on skill assessment, polyp segmentation, and depth estimation. These results establish SurgMotion as a new standard for universal, motion-oriented surgical video understanding.
Jinlin Wu, Felix Holm, Chuxi Chen +18
Nov 18, 2025cs.CV

NeuralBoneReg: An Instance-Specific Label-Free Point Cloud-Based Method for Multi-Modal Bone Surface Registration

In computer- and robot-assisted orthopedic surgery (CAOS), patient-specific surgical plans derived from preoperative imaging define target locations and implant trajectories. During surgery, these plans must be accurately transferred, relying on precise cross-registration between preoperative and intraoperative data. However, substantial modality heterogeneity across imaging modalities makes this registration challenging and error-prone. Robust, automatic, and modality-agnostic bone surface registration is therefore clinically important. We propose NeuralBoneReg, a self-supervised, surface-based framework that registers bone surfaces using 3D point clouds as a modality-agnostic representation. NeuralBoneReg includes two modules: an implicit neural unsigned distance field (UDF) that learns the preoperative bone model, and an MLP-based registration module that performs global initialization and local refinement by generating transformation hypotheses to align the intraoperative point cloud with the neural UDF. Unlike SOTA supervised methods, NeuralBoneReg operates in a self-supervised manner, without requiring inter-subject training data. We evaluated NeuralBoneReg against baseline methods on two publicly available multi-modal datasets: a CT-ultrasound dataset of the fibula and tibia (UltraBones100k) and a CT-RGB-D dataset of spinal vertebrae (SpineDepth). The evaluation also includes a newly introduced CT-ultrasound dataset of cadaveric subjects containing femur and pelvis (UltraBones-Hip), which will be made publicly available. NeuralBoneReg matches or surpasses existing methods across all datasets, achieving mean RRE/RTE of 1.83°/2.02 mm on UltraBones100k, 1.90°/1.56 mm on UltraBones-Hip, and 3.78°/2.80 mm on SpineDepth. These results demonstrate strong generalizability across anatomies and modalities, providing robust and accurate cross-modal alignment for CAOS.
Luohong Wu, Matthias Seibold, Nicola A. Cavalcanti +5
Oct 14, 2025cs.CV

State-Change Learning for Prediction of Future Events in Endoscopic Videos

Surgical future prediction, driven by real-time AI analysis of surgical video, is critical for operating room safety and efficiency. It provides actionable insights into upcoming events, their timing, and risks-enabling better resource allocation, timely instrument readiness, and early warnings for complications (e.g., bleeding, bile duct injury). Despite this need, current surgical AI research focuses on understanding what is happening rather than predicting future events. Existing methods target specific tasks in isolation, lacking unified approaches that span both short-term (action triplets, events) and long-term horizons (remaining surgery duration, phase transitions). These methods rely on coarse-grained supervision while fine-grained surgical action triplets and steps remain underexplored. Furthermore, methods based only on future feature prediction struggle to generalize across different surgical contexts and procedures. We address these limits by reframing surgical future prediction as state-change learning. Rather than forecasting raw observations, our approach classifies state transitions between current and future timesteps. We introduce SurgFUTR, implementing this through a teacher-student architecture. Video clips are compressed into state representations via Sinkhorn-Knopp clustering; the teacher network learns from both current and future clips, while the student network predicts future states from current videos alone, guided by our Action Dynamics (ActDyn) module. We establish SFPBench with five prediction tasks spanning short-term (triplets, events) and long-term (remaining surgery duration, phase and step transitions) horizons. Experiments across four datasets and three procedures show consistent improvements. Cross-procedure transfer validates generalizability.
Saurav Sharma, Chinedu Innocent Nwoye, Didier Mutter +1
Oct 6, 2025cs.CV

Federated Learning for Surgical Vision in Appendicitis Classification: Results of the FedSurg EndoVis 2024 Challenge

Developing generalizable surgical AI requires multi-institutional data, yet privacy constraints preclude direct data sharing, making Federated Learning (FL) a natural candidate. Its application to complex, spatiotemporal surgical video remains largely unbenchmarked. We present the FedSurg Challenge, the first international initiative dedicated to FL in surgical vision, as a proof-of-concept evaluation using a multi-center dataset of laparoscopic appendectomies (subset of Appendix300). Three participant submissions were evaluated on generalization to an unseen clinical center and center-specific local adaptation, alongside centralized, Swarm Learning, parameter-efficient fine-tuning baselines, and reference classifiers. Our analysis identifies temporal modeling as the architectural factor most consistently associated with generalization to the unseen center, although effects vary across metrics. Classifier collapse arises from both the global model's failure to transfer under domain shift and unconstrained fine-tuning on small, imbalanced local datasets, motivating structured personalized FL for center-specific adaptation. Absolute performance remains far from clinical viability: even with all data pooled centrally, the task reached a 26.31% F1-score on the unseen center. Paired permutation tests resolve only large differences, and no adaptation comparison reaches significance at this sample size. By characterizing these limitations, this work establishes a methodological reference point for privacy-preserving surgical video AI.
Max Kirchner, Hanna Hoffmann, Alexander C. Jenke +16